Furnace Solutions

download Furnace Solutions

of 2

Transcript of Furnace Solutions

  • 7/29/2019 Furnace Solutions

    1/2

    ProductSpecificati

    ons

    Graphite Furnace Atomic Absorption

    Spectrometry (GFAAS) is an established

    analytical technique for measuring a large

    number of elements at parts per billion

    levels. Sample consumption is incredibly

    low, with only a few microlitres of sample

    injected directly into a graphite cuvette.

    Controlled electrical heating of the cuvette

    dries the sample and removes the matrix

    prior to atomization. Hollow cathode lamps

    provide specific elemental light output,

    which is directed through the centre of thecuvette to allow measurement during

    atomization. High performance optics and

    precise monochromator operation ensure

    the light path is always perfectly aligned for

    analysis.

    Dedicated furnace solutions from the

    Thermo Scientific iCE 3000 Series Atomic

    Absorption Spectrometers are developed to

    make the user experience as simple as

    possible, without compromising

    performance or functionality. The Wizard

    driven Thermo Scientific SOLAAR software

    guides even the novice user through

    optimization, method development and

    analysis, while the integrated furnace

    autosampler allows fully automated and

    unattended operation. A suite of reportingand post-processing options are available to

    interrogate results, create customized

    reports and export data to external systems.

    Dedicated Furnace Solutions from the Thermo ScientificiCE 3000 Series Atomic Absorption SpectrometersBackground corrected, fully automated, ultra-trace analysis

    The Thermo Scientific iCE 3000

    Series Atomic Absorption

    Spectrometers provide the

    complete trace elemental analysis

    package, offering stunning

    simplicity, innovative design and

    superior analytical performance.

    Part of Thermo Fisher Scientific

    e l e m e n t a l a n a l y s i s

  • 7/29/2019 Furnace Solutions

    2/2

    Dedicated Furnace AtomicAbsorption Spectrometers

    Dedicated furnace systems provide an ideal

    solution for laboratories requiring parts per

    billion detection limits and automated

    sample analysis. Furnace systems can be

    left to run unattended, while a wide variety

    of quality and performance checks can be

    programmed into the software to monitor

    performance and ensure accuracy of results

    over prolonged analysis periods.

    The iCE 3000 Series AA Spectrometers

    includes two dedicated graphite furnace

    atomic absorption systems, for those users

    who do not require flame capabilities.

    1. The Thermo Scientific iCE 3300GF AAspectrometer is a compact system withDeuterium background correction and anEbert optical system.

    2. The Thermo Scientific iCE 3400 AAspectrometer offers both Zeeman andDeuterium background correction with asophisticated Echelle optical system.

    Features and Accessories

    GFTV provides real time internal vision ofthe graphite cuvette, enabling observationof sample deposition and drying behavior.GFTV is provided as standard to aidmethod development, ensuring repeatableanalysis, time after time.

    The integrated furnace autosampler notonly deposits samples with accuracy andprecision, it also prepares multiplestandards from a single master standard,intelligently dilutes over-range samplesand adds matrix modifiers to complex

    samples. A dedicated Furnace Validator Package

    available, providing InstallationQualification (IQ) and fully automatedOperational Qualification (OQ) for thesystem. (Optional).

    Thermo Scientific SOLAARsecurity, is anaddition to the SOLAAR software,enabling permission controls tofunctionality and application of electronicsignatures. This is essential for regulatedlaboratories and those requiring 21 CFRPart 11 compliance. (Optional).

    Product Specifications

    PS43075_E 03/11C

    Thermo Electron Manufacturing Ltd(Cambridge) is ISO Certified.

    Africa-Other +27 11 570 1840Australia +61 3 9757 4300

    Austria +43 1 333 50 34 0Belgium +32 53 73 42 41Canada +1 800 530 8447China +86 10 8419 3588Denmark +45 70 23 62 60

    Europe-Other +43 1 333 50 34 0Finland/Norway/Sweden

    +46 8 556 468 00France +33 1 60 92 48 00Germany +49 6103 408 1014India +91 22 6742 9434Italy +39 02 950 591

    Japan +81 45 453 9100Latin America +1 561 688 8700

    Middle East +43 1 333 50 34 0Netherlands +31 76 579 55 55New Zealand +64 9 980 6700Russia/CIS +43 1 333 50 34 0South Africa +27 11 570 1840

    Spain +34 914 845 965Switzerland +41 61 716 77 00

    UK +44 1442 233555USA +1 800 532 4752

    www.thermoscientific.com

    2011 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, termsand pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.

    iCE 3300GF iCE 3400

    General

    Number of sample compartments 1 1

    PC Control Yes Yes

    Software Included as standard Included as standard

    Lamp carousel Auto aligning Auto aligning

    Lamp capacity 6 6

    Lamp type coded and uncoded coded and uncodedsingle and multi element single and multi element

    Optics

    Monochromator Ebert Echelle

    Spectral bandwidths 0.2, 0.5 and 1.0 nm 0.1 (below 400 nm),

    0.2, 0.5 and 1.0 nm

    Reciprocal linear dispersion 2.0 nm/mm at 200 nm 0.5 nm/mm at 200 nm

    Grating 1800 lines/mm 2D Spectrum

    Optical set up Automatic Automatic

    Wavelength range 180-900 nm 180-900 nm

    Drift correction Double beam Self referencing

    Furnace Features

    Furnace model GFS33 GFS35Z

    Furnace vision system (GFTV) As Standard As Standard

    Furnace background correction Deuterium Deuterium and Zeeman

    Furnace autosampler Included as standard Included as standard

    Cuvettes Normal, Coated, Normal, Coated,Extended life (ELC), Platform Extended life (ELC), Platform

    Options Available

    Vapor upgrade Yes Yes

    Validator packages Yes Yes

    Security software Yes Yes

    Table 1: Summary of the dedicated furnace solutions from theiCE 3000 Series Atomic Absorption Spectrometers

    The full range of iCE 3000 Series Atomic Absorption Spectrometers includes dedicated flame,dedicated furnace and dual atomizer options. Discover them all at www.thermoscientific.com/ice