Fundaments of Electro Hidraulics

download Fundaments of Electro Hidraulics

of 34

Transcript of Fundaments of Electro Hidraulics

  • 8/11/2019 Fundaments of Electro Hidraulics

    1/34

    095051 GB

    Fundamentals of

    Electrohydraulics

    Collection of

    Transparencies

    T A P B

    T A P B

    A

    a b

    B

    P T

    a

    a

    b

    b

  • 8/11/2019 Fundaments of Electro Hidraulics

    2/34

    Order no.: 095051

    Designation: E.-HYDR-FOLIEN.

    Description: D:OT-TP601-GB

    Edition: 07/2001

    Author: Dieter Scholz

    Graphics: Doris Schwarzenberger

    Layout: 18.07.2001, Beatrice Huber

    Festo Didactic GmbH & Co., D-73770 Denkendorf, 2001

    Internet: www.festo.com/didactic

    e-mail: [email protected]

    The copying, distribution and utilization of this document as well as the

    communication of its contents to others without expressed authorization is

    prohibited. Offenders will be held liable for the payment of damages. All rights

    reserved, in particular the right to carry out patent, utility model or ornamentaldesign registration.

  • 8/11/2019 Fundaments of Electro Hidraulics

    3/34

    Foreword

    Festo Didactic GmbH & Co. Electrohydraulics

    This set of overhead transparencies has been designed for use with the basic levelof the technology package TP600 Electrohydraulics. The set of overhead

    transparencies and the technology package form part of the Learning System for

    Automation from Festo Didactic GmbH & Co.

    The 30 transparencies in this set have been optimised from the didactic and

    methodological points of view. Each transparency is accompanied by a short text

    which provides the trainer with a quick overview of the training contents of the

    transparency concerned.

    Basic principles of electrohydraulics

    Function and use of electrohydraulic components

    Basic principles of electrical engineering

    Production and interpretation of standard hydraulic and electrical circuit

    diagrams

    The text sheet includes a complete illustration of the transparency, in certain cases

    with additional explanations and legends which the trainer can enter on the

    transparency in the course of a training session.

    The advantages of this concept are:

    The trainer can add to the transparencies step by step in the course of a trainingsession.

    The trainer is thus able to create a lively and interesting atmosphere.

    The provision of accompanying text means less preparation work for the trainer.

    The enclosed CD-ROM contains the entire overhead transparencies and

    accompanying text of this edition in an electronically presentable form in the files

    Electrohydraulics _transparencies.pdf and Electrohydraulics _text.pdf. In

    addition to the screen presentation, which can be made in any order, the contents

    can be printed out and text and graphics can be used for your own training

    preparations, insofar as the functionality of the required Adobe

    Acrobat

    Reader

    permits this. This freely distributable software is available on the CD-ROM in the

    currently valid English version for Windows 95/98/NT for installation in the directory

    Acrobat_Reader. Please start the file rs405eng.exe and follow the subsequent

    dialogue.

    Training contents

    New!

    Electronic presentation

  • 8/11/2019 Fundaments of Electro Hidraulics

    4/34

    Contents

    Festo Didactic GmbH & Co. Electrohydraulics

    Electrohydraulic press _______________________________________ Transparency 1Schematic layout of an electrohydraulic installation ______________ Transparency 2

    Electrical power supply unit __________________________________ Transparency 3

    Electrical circuit ____________________________________________ Transparency 4

    Measuring circuits __________________________________________ Transparency 5

    Ohms law _________________________________________________ Transparency 6

    Rectifiers __________________________________________________ Transparency 7

    Analogue, digital and binary __________________________________ Transparency 8

    Momentary and sustained contact switches _____________________ Transparency 9

    N/O, N/C and changeover contacts ___________________________ Transparency 10

    Limit switches_____________________________________________ Transparency 11

    Proximity switches _________________________________________ Transparency 12

    Solenoid (electromagnet) ___________________________________ Transparency 13

    Electrohydraulic converters (solenoid valves)___________________ Transparency 14

    Dry solenoidswet solenoids________________________________ Transparency 15

    Solenoid valve connections__________________________________ Transparency 16

    Relays and contactors ______________________________________ Transparency 17

    Direct activationindirect activation __________________________ Transparency 18

    Signal inversion ___________________________________________ Transparency 19

    Latching__________________________________________________ Transparency 20

    Circuit diagram ____________________________________________ Transparency 21

    Hydraulic power pack_______________________________________ Transparency 22Hydraulic circuit ___________________________________________ Transparency 23

    Electrical powerhydraulic power ____________________________ Transparency 24

    Power losses______________________________________________ Transparency 25

    Pressure switches__________________________________________ Transparency 26

    4/3-way solenoid valve _____________________________________ Transparency 27

    4/3-way solenoid valve, piloted ______________________________ Transparency 28

    Electrical safety____________________________________________ Transparency 29

    Hydraulic safety ___________________________________________ Transparency 30

  • 8/11/2019 Fundaments of Electro Hidraulics

    5/34

    1

    Festo Didactic GmbH & Co. Electrohydraulics

    Electrohydraulic press

    Motor with hydraulic pump

    Control panel

    Valve manifold

    Cylinder

    The hydraulic press is controlled via the electrical control panel.

    Electrical signals are used to activate the valves in the hydraulic installation.

    The electrohydraulic press is used to form rectangular troughs.

    Control pane

    Motor withhydraulic pump

    Valve manifold

    Actuator(cylinder)

    Function units

  • 8/11/2019 Fundaments of Electro Hidraulics

    6/34

    2

    Festo Didactic GmbH & Co. Electrohydraulics

    Schematic layout of an electrohydraulic installation

    Division of installation into signal control section and hydraulic power section.

    Input and processing of electrical signals.

    Solenoid valves form the interface between the electrical signal control section and

    the hydraulic power section.

    Controls the flow of hydraulic fluid by means of solenoid valves. Actuators convert

    hydraulic energy into motions.

    Signal control section

    Signalinput

    Hydrauliccylinder

    Solenoidvalve

    Hydraulicpowersupply(conversion)

    Powersupply

    Signalprocessing

    Power section

    Signal control section

    Hydraulic power section

  • 8/11/2019 Fundaments of Electro Hidraulics

    7/34

    3

    Festo Didactic GmbH & Co. Electrohydraulics

    Electrical power supply unit

    Connection to mains supply.

    Supplies signal control section with specified or maximum voltage and current

    values.

    Voltage transformation

    Rectification

    Smoothing

    Stabilisation

    Fuse protection

    In mobile hydraulic systems, rechargeable battery systems or generators are used

    as a power supply for the signal control section.

    230VAC

    24VDC

    TR

    50 C

    G C T T

    Transformer Rectifier Smoothing Stabilisation Fuse

    Functions in

    power supply unit

  • 8/11/2019 Fundaments of Electro Hidraulics

    8/34

    4

    Festo Didactic GmbH & Co. Electrohydraulics

    Electrical circuit

    A circuit consists of at least a power source, a load device and connecting lines.

    Electrical current will flow only in a closed circuit.

    Electrical current flows from the positive terminal of the power supply to the

    negative terminal.

    Closed circuit without power supply.

    Introduction of a power supply to complete the circuit.

    A B

    +

    Technical direction

    of current flow

    Figure A

    Figure B

  • 8/11/2019 Fundaments of Electro Hidraulics

    9/34

    5

    Festo Didactic GmbH & Co. Electrohydraulics

    Measuring circuits

    The voltage drop across a load device is measured in parallel with the device.

    Electrical current is measured in series.

    ++

    Voltage measurement Current measurement

    Voltage measurement

    Current measurement

  • 8/11/2019 Fundaments of Electro Hidraulics

    10/34

    6

    Festo Didactic GmbH & Co. Electrohydraulics

    Ohms law

    Describes the relationship between current (I), voltage (V) and resistance (R).

    With ohmic resistances, the current rises in linear proportion to the voltage.

    The value pairs for a constant resistance lie on a straight line. The current I is

    proportional to the voltage V.

    Mathematical formula for Ohms law: V = R I

    I = V : R

    +

    R

    A

    2.0

    1.5

    1.0

    0.5

    0100 20

    V

    I

    30 40V

    10 V

    0.5 A

    0.33 A

    Voltage V

    20 V

    1.0 A

    0.66 A

    30 V

    1.5 A

    1.0 A

    40 V

    2.0 A

    1.33 A

    A

    V

    V = R I

    I =RV

    Resistance R

    Relay

    Solenoid coil

    Ohms law

    Graph

  • 8/11/2019 Fundaments of Electro Hidraulics

    11/34

    7

    Festo Didactic GmbH & Co. Electrohydraulics

    Rectifiers

    Rectifiers convert AC to DC.

    Diodes are conductive in only one direction.

    The polarity of the negative half-wave of the alternating voltage is reversed.

    The pulsating voltage is smoothed using a capacitor and filters (reactance coil,

    resistor).

    ~

    =

    VV

    t

    V

    tt

    C R

    L

    Diodes

    Voltage

    retification

    Voltage

    smoothing

  • 8/11/2019 Fundaments of Electro Hidraulics

    12/34

    8

    Festo Didactic GmbH & Co. Electrohydraulics

    Analogue, digital and binary

    Analogue values describe continuous functions, such as the continuous filling of a

    bucket of water.

    Digital values describe integer parts of a maximum value. A dice, for example, shows

    one of six possible numbers.

    Binary values are a special form of digital values. They can assume only two values,

    such as in the case of a switch, which can only be on or off.

    On 1

    Value

    +

    1

    6

    5

    4

    3

    2

    0VolumeV

    Filling time t Experiments with dice

    Light

    Time tSwitchingtime point

    Off 0

    full

    half-full

    empty

    Analogue values

    Digital values

    Binary values

  • 8/11/2019 Fundaments of Electro Hidraulics

    13/34

    9

    Festo Didactic GmbH & Co. Electrohydraulics

    Momentary and sustained contact switches

    Actuation of contacts.

    A momentary contact switch has a rest positionand an actuated position.

    A sustained contact switch has two detents. It thus has two rest positions.

    Momentary and sustained switches can close or open current paths or switch from

    one current path to another.

    3 3

    4 4

    Momentary contact switch

    Sustained contact switch

  • 8/11/2019 Fundaments of Electro Hidraulics

    14/34

    10

    Festo Didactic GmbH & Co. Electrohydraulics

    N/O, N/C and changeover contacts

    Contact normally open in rest position.

    Example: Momentary-contact switch

    N/O and N/C contacts in a single housing; one contact is open while the other is

    closed.

    The designations of the switch contacts are governed by the European standard

    EN 50012.

    Connection(N/C contact)

    42

    1

    3 1

    4 2

    Connection(N/O contact)

    Switch elements

    N/O

    N/C

    Changeover contact

  • 8/11/2019 Fundaments of Electro Hidraulics

    15/34

    11

    Festo Didactic GmbH & Co. Electrohydraulics

    Limit switches

    Determining the position of a positioning slide.

    Electrical contacts are actuated when a defined intermediate or end position is

    reached.

    Limit switches can be connected up as N/O, N/C or changeover contacts.

    Switch leverStem (insulated)

    Contact

    Snap-actionmechanism

  • 8/11/2019 Fundaments of Electro Hidraulics

    16/34

    12

    Festo Didactic GmbH & Co. Electrohydraulics

    Proximity switches

    Signal is generated by the presence of any material with good conductivity in an

    oscillating magnetic field.

    Signal is also generated by all insulators with high dielectric constants in an

    electrical field.

    Signal is generated when light barriers are interrupted or when light is reflected

    back to an optical sensor.

    Signal is generated by magnets whose fields close the built-in contacts in the switch.

    Magnet

    Metal

    MetalorInsulator

    reflectivecompo-nent

    inductive

    capacitive

    optical magnetic

    Reed switch

    Inductive

    Capacitive

    Optical

    Reed switches

  • 8/11/2019 Fundaments of Electro Hidraulics

    17/34

    13

    Festo Didactic GmbH & Co. Electrohydraulics

    Solenoid (electromagnet)

    A magnetic field with concentric field lines is created around a conductor carrying an

    electrical current.

    A coil carrying an electrical current develops a uniform magnetic field in its axial

    direction due to the overlapping of field lines.

    By appropriate alignment of elementary magnets, an iron core can be made into a

    switchable electromagnet.

    +

    Field around

    a conductor

    Coil

    Coil

    Iron core

  • 8/11/2019 Fundaments of Electro Hidraulics

    18/34

    14

    Festo Didactic GmbH & Co. Electrohydraulics

    Electrohydraulic converters (solenoid valves)

    Convert electrical signals into hydraulic switching operations.

    The switching armature is drawn into the coil, which acts as a magnet.

    This produces a displacement of the actuating piston in the hydraulic 4/2-way valve.

    A B

    P T

    Switching armature

    4/2-way solenoid valve

    BT A P L

  • 8/11/2019 Fundaments of Electro Hidraulics

    19/34

    15

    Festo Didactic GmbH & Co. Electrohydraulics

    Dry solenoidswet solenoids

    The solenoid is separated from the hydraulic fluid; a seal is required on the stem.

    Simple construction

    The armature chamber of the solenoid is filled with hydraulic fluid, the solenoid

    operates in oil.

    Low friction

    Little abrasion

    Good heat dissipation

    Long service life

    seal

    Dry solenoid Wet solenoid

    Dry solenoid

    Advantage

    Wet solenoid

    Advantages

  • 8/11/2019 Fundaments of Electro Hidraulics

    20/34

    16

    Festo Didactic GmbH & Co. Electrohydraulics

    Solenoid valve connections

    Solenoid with plug base

    Cable with connector socket

    Electrical signals are transmitted via standard connectors.

    Reliable alignment of connections

    Connections can be attached and detached quickly

    Protected against dust and water

    2

    1

    3

    Protective earth connection

    Plug base

    Electricalconnections

    Connector components

    Advantages

  • 8/11/2019 Fundaments of Electro Hidraulics

    21/34

    17

    Festo Didactic GmbH & Co. Electrohydraulics

    Relays and contactors

    Switches which are actuated and held in their actuated positions

    electromagnetically.

    Used to separate control and power circuits.

    Hinged-armature design

    Single-break contacts

    Used for logic gating of signals

    (generally) changeover contacts

    Each main contact is of double-break type (contacts used as main contacts),

    suitable for

    all power ratings from small to very large

    only N/O and N/C contacts

    +

    +

    Contacts

    Return spring

    Return spring

    Contacts Coil

    Coil

    Iron core

    Armature

    Hinged-armature solenoid Plunger-armature solenoid

    Definition

    Special feature

    of relays

    Special feature

    of contactors

  • 8/11/2019 Fundaments of Electro Hidraulics

    22/34

    18

    Festo Didactic GmbH & Co. Electrohydraulics

    Direct activationindirect activation

    Connection of a solenoid valve via a switch (Fig. A).

    Connection of a solenoid valve via a relay (Fig. B).

    Separation of control and power circuits

    The current passing through switch S1 (Fig. B) is lower, and the service life of the

    switch is significantly greater.

    A B

    24 V

    0 V

    1 224 V

    0 V

    S1 S1 K1

    Y1 K1 Y1

    1

    3 3 3

    4 4 4

    Direct activation

    Indirect activation

    Advantage of

    indirect activation

  • 8/11/2019 Fundaments of Electro Hidraulics

    23/34

    19

    Festo Didactic GmbH & Co. Electrohydraulics

    Signal inversion

    The output signal is inversely proportional to the input signal.

    Signal inversion at relay K1.

    Signal inversion at switch S1.

    The switching elements are shown under zero-voltage conditions.

    24 V

    0 V

    1 2

    S1 K1

    0

    10

    1

    Y1

    0

    1

    B

    S1 K1

    K1 Y1

    31

    42

    24 V

    0 V

    1 2

    S1 K1

    1

    00

    1

    Y1

    0

    1

    A

    S1 K1

    K1 Y1

    3 1

    4 2

    Figure A

    Figure B

  • 8/11/2019 Fundaments of Electro Hidraulics

    24/34

    20

    Festo Didactic GmbH & Co. Electrohydraulics

    Latching

    Latching only with indirect activation.

    Actuation of switch S1: Relay K1 reverses holding the current path of K1 closed.

    The actuation of switch S2 interrupts the latched current path.

    K1 K13 3

    4 4

    24 V

    0 V

    1 2 3

    S1

    K1 Y1

    3

    4

    S21

    2

    S1 S2

    0 0

    K1 & Y1

    0

    1

    0

    1

    0 0

    1 1

    1

    dominant on

    1

  • 8/11/2019 Fundaments of Electro Hidraulics

    25/34

    21

    Festo Didactic GmbH & Co. Electrohydraulics

    Circuit diagram

    Lines of potential with constant voltage are drawn horizontally.

    Current paths are drawn vertically and numbered consecutively.

    Circuit symbols are shown in the direction of current flow.

    Switching elements are generally shown under zero-voltage conditions.

    Latching to guard against sticking of relay contacts in current paths 6 and 7.

    K23

    4

    S2

    K2

    3

    4

    A2

    A1

    K13

    4

    S1

    S0

    K1 Y1 Y2

    3

    3

    4

    4

    K2 K11 1

    2 2

    A2

    A1

    K1 K23 3

    4 4

    24 V

    0 V

    1

    2 3 4 5 6 7

  • 8/11/2019 Fundaments of Electro Hidraulics

    26/34

    22

    Festo Didactic GmbH & Co. Electrohydraulics

    Hydraulic power pack

    Hydraulic power pack for use in stationary hydraulic systems.

    Power is delivered via the pressure medium using a pump and drive motor.

    The pack incorporates devices to remove air, water and solid particles from the

    hydraulic fluid.

    Baffle plate

    Pressure relief valve(safety valve)

    Hydraulic pump

    Suction pipe

    Suction filter

    Return line

    Air filter

    Filler filter

    Fluid level indicator

    Cleaning aperture

    Drain screw

    Pressure line

    Electric motor n = 1500 rpm

  • 8/11/2019 Fundaments of Electro Hidraulics

    27/34

    23

    Festo Didactic GmbH & Co. Electrohydraulics

    Hydraulic circuit

    Hydraulic systems consist of open or closed circuits.

    Hydraulic fluid is used as an energy carrier.

    This energy is output via cylinders and motors.

    Relieved hydraulic fluid is returned to the tank or hydraulic pump.

    Hydraulicmotor

    Motor

    Filter

    Motor

    Hydraulic cylinder

    Electrohydraulicpower valve

    Safetyvalve

    Safetyvalve

    Hydraulicpump

    Return

    line

    Safety valve

    Feed pump(top-up forleakage losses)

    Hydraulic pump

    open closed

  • 8/11/2019 Fundaments of Electro Hidraulics

    28/34

    24

    Festo Didactic GmbH & Co. Electrohydraulics

    Electrical powerhydraulic power

    Driven by electric current on the basis of a potential difference.

    Electrical power is the product of voltage and current

    Pelectr.= V I (unit: watts).

    Driven via fluid flow on the basis of a pressure difference.

    Hydraulic power is the product of pressure and flow rate

    Phydr.= p Q (unit: watts).

    Electric motor

    +

    P = Ielectr. P = p qhydr.

    Current I

    Vol

    tage

    V

    Pres

    sure

    p

    Flowrate q

    Gear motor

    Electric motor

    Hydraulic motor

  • 8/11/2019 Fundaments of Electro Hidraulics

    29/34

    25

    Festo Didactic GmbH & Co. Electrohydraulics

    Power losses

    Frictional losses

    Magnetic losses

    Frictional losses

    Volumetric losses

    Pressure losses dp

    Power losses expressed by P = dp Q

    Frictional losses

    Volumetric losses

    P = p qhydr. loss

    Frictional andvolumetric losses

    Frictional andpressure losses

    Frictional,volumetric andmagnetic losses

    Powerlo

    sses

    Efficiency of electric motors

    Efficiency of hydraulic pump

    Valves, piping, tubing

    Hydraulic motors

    and cylinders

  • 8/11/2019 Fundaments of Electro Hidraulics

    30/34

    26

    Festo Didactic GmbH & Co. Electrohydraulics

    Pressure switches

    Actuation of electrical contacts when a defined minimum pressure is reached.

    The minimum pressure (switching point) can be varied by means of an adjustable

    spring.

    Example shows switching at approx. 4 bar with rising or falling pressure.

    Generally connected up in practice as a changeover contact.

    Hysteresis

    2

    3

    1

    1

    2 3

    4 bar

    pp

    a

    a/c

    b

    c

    b

    Switching point with rising pressure

    Switching point with falling pressure

    Symbolic representationin electrical circuit diagram

    Symbolic representationin hydraulic circuit diagram

    Pressurep

    Time t

  • 8/11/2019 Fundaments of Electro Hidraulics

    31/34

    27

    Festo Didactic GmbH & Co. Electrohydraulics

    4/3-way solenoid valve

    Valve spool is directly actuated by solenoids.

    The piston spool is displaced to the right and creates the connections PA

    and BT.

    Rest position produced by spring centring of piston spool. All inputs of the 4/3-way

    valve are closed in this position.

    T A P B

    T A P B

    A

    a b

    B

    P T

    a

    a

    b

    b

    Actuation on left

    Rest position

  • 8/11/2019 Fundaments of Electro Hidraulics

    32/34

    28

    Festo Didactic GmbH & Co. Electrohydraulics

    4/3-way solenoid valve, piloted

    Direct activation of pilot spool via solenoids.

    The pilot piston spool is displaced to the right, and hydraulic fluid is directed to the

    right-hand side of the main control spool, creating the connections PA and BT.

    Rest position produced by spring centring of pilot and main piston spools. All ports

    of the 4/3-way valve are closed at the main valve.

    Simplified symbol

    P T

    A

    A

    B

    B

    P T

    PB AT

    Detailed symbol

    Actuation on left

    Rest position

  • 8/11/2019 Fundaments of Electro Hidraulics

    33/34

    29

    Festo Didactic GmbH & Co. Electrohydraulics

    Electrical safety

    EMERGENCY STOP button placed in an easily accessible position

    Protection against voltages

    Protection by means of insulation

    Protection by means of earthed conductive housings

    Safety isolation by means of transformers

    L1

    24 VPE

    N

    1) Switch off2) Check3) Carry out work

    EMERGENCY

    STOP

    Basic insulation

    Additionalinsulation

    220 V AC

    Safety insulation Protective earth Safety isolation

  • 8/11/2019 Fundaments of Electro Hidraulics

    34/34

    30

    Hydraulic safety

    Safety regulations must be observed.

    Switch off motor/pump

    Depressurise accumulator

    Lower load

    Check pressure

    Work can now be carried out by authorised trained personnel.

    m

    1) Switch offmotor/pump

    2) Depressurise accumulator

    4) Check pressure

    3) Lower load