Fundamentals of
Pipe & Cable Locating
May 7, 2019
Eric Six
Heath Consultants Incorporated
![Page 2: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/2.jpg)
Pipe and Cable Locator
A device that is usually made up of two
components, a transmitter and a receiver,
that is used to transmit an electro magnetic
signal onto an intended target (conductor).
![Page 3: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/3.jpg)
LOCATING INSTRUMENTS
![Page 4: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/4.jpg)
How does a Pipe or Cable
Locator work?
The transmitter generates a signal on a
specific frequency to energize the target.
The receiver is tuned to the same frequency
as the transmitter.
The target (conductor) is “energized” by the
signal from the transmitter.
![Page 5: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/5.jpg)
TYPES OF CONDUCTORS
Cable TV –This in most cases will be the easiest because of the shallow depth at which it is buried and the fact that it is a natural conductor of signal.
Telephone – Good conductor; is bonded. But in most cases it is buried deeper, thus giving a weaker signal.
Electric Cable –A good conductor because it is coated and all grounds are bonded.
Tracer Wire/Tracer Tape-Another good conductor, but notas good as electric cable because itcarries a smaller signal on its 12 gauge wire, however, usuallyburied about the same depth.
![Page 6: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/6.jpg)
TYPES OF CONDUCTORS (cont’d)
Copper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in itself, makes it easier to locate than other types of pipe.
Wrapped steel –Not the best conductor, but far from the worst. Because it is welded and wrapped, it will carry a fair signal.
Bare steel –It is getting near the bottom of the barrel when it comes to conductors.
Cast / Ductile iron –It is locatable, but not easy, due to the fact that cast iron is not a good conductor. It also has bell joints which act as insulators.
![Page 7: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/7.jpg)
THEORY
![Page 8: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/8.jpg)
THEORY
Pipe locator consist of two
parts:
Receiver and Transmitter
Transmitter:
Functions as a stationary
device
Broadcast an electromagnetic
signal onto a conductor
![Page 9: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/9.jpg)
TRANSMITTER
A pipe is an electrical conductor (metal). When it is
energized with current from a transmitter a magnetic
field is produced in the shape of concentric circles
which spreads along the pipe.
![Page 10: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/10.jpg)
RECEIVER
Portable component that detects and
Interprets the transmitters signal.
Receiver is tuned into the
Frequency of the signal
![Page 11: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/11.jpg)
Transmitter Frequencies
Low Frequency 800Hz to 20Khz
– Advantages: Distance & Adherence
– Disadvantage: Poor Penetration
High Frequency 250Khz to 480Khz
– Advantages: Good Penetration
– Disadvantages: Distance & Adherence
Medium Frequency:20Khz to 250Khz
– Best frequency for general locating
![Page 12: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/12.jpg)
THEORY - FREQUENCY
A frequency results
from the summation of
several oscillations
produced by electronic
components called
crystals.
![Page 13: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/13.jpg)
FREQUENCIES
Broken down into three groups:
– High radio frequency (250-480Khz)
– Medium radio frequency (60-200Khz)
– Low Audio frequency (500hz–33Khz)
Red: Lowest frequency
Green: Medium frequency
Blue: Highest frequency
![Page 14: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/14.jpg)
Modes of Operation
Conductive (direct hook up)
– Often hard to find contact point, better accuracy
Inductive (indirect)
– Easy to setup, least accurate way to locate
Inductive Clamp
– Better accuracy than inductive
Passive
– Detects 60Hz AC “ripple” on conductor
![Page 15: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/15.jpg)
CONDUCTIVE MODE: or Direct Connection to the
pipe/cable
Black wire Red wire
Transmitter
Metal-to-metal On pipe
![Page 16: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/16.jpg)
Conductive
• Preferred Method that will send
the strongest signal to your
receiver.
• Results in better accuracy
• Less likely to “bleed” over to
other conductors.
• This method allows for the use of a
greater range of frequency and power
outputs.
Black wire
Conduction of signal
Red wire
Transmitter
Metal-to-metal
hook-up
![Page 17: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/17.jpg)
INDUCTIVE LOCATING
![Page 18: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/18.jpg)
INDUCTIVE MODE: or not connecting to any pipe/cable
Is least preferred
Poor isolation of signal
Least accurate
Transmitter
Smaller metal mass
conductor
Larger metal
Mass conductor
Induction of signal
![Page 19: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/19.jpg)
INDUCTIVE BASIC FACTS
Easiest and Quickest
Disadvantage – most inaccurate
Internal antenna of the transmitter energizes the conductor through the process of induction. Signal returns more easily through the ground.
Transmitter should be placed over a known point to work effectively.
Bleed off to other conductors is more likely, then the conductive mode. Best to use in areas with no other conductors, if possible.
![Page 20: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/20.jpg)
Choosing the Right Tool
Simple Split Box vs. Electronic Locator
– Split Box Locator should be used for short
incidental locates, C&M crew, leak repair, etc.
– Single Frequency Computerized Locator is
recommended for more accurate locates where
depth measurements are needed.
– Multi-Frequency Computerized Locators are
recommended for Damage Prevention and
trouble shooting Cathodic Protection Systems.
![Page 21: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/21.jpg)
FEATURES - PEAK VS NULL
Null response
Peak response
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
Ground level
![Page 22: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/22.jpg)
Other Types of Locators
Valve Box Locator
– Treasure finder type instrument
Ferromagnetic Locator
– Locates iron based objects only
Ground Penetrating Radar
– Must interpret readings
![Page 23: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/23.jpg)
Keys to Accurate Locating
Always read instruction manual provided
with instrument.
Request on-site training by qualified person.
Become familiar with operation of
instrument on “known” locates.
Research conductor to be located:
– Maps, Service Records, Inspection Reports
![Page 24: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/24.jpg)
Keys to Accurate Locating
Read the Street before locating:
– Look for visual indicators, valves, hydrants,
pedestals, test stations, etc.
For best accuracy, always use the
Conductive Mode
When grounding the transmitter, try to run
ground cable at a 90o angle to the
conductor.
![Page 25: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/25.jpg)
T
Always Ground at a 90o Angle
![Page 26: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/26.jpg)
Keys to Accurate Locating
Always connect cable assembly from
transmitter to “clean shiny metal”.
Never run ground wire over or near other
conductors.
When locating in the inductive mode, make
sure transmitter is aligned properly with the
intended conductor.
Always check for “air lock”.
![Page 27: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/27.jpg)
Keys to Accurate Locating
Depth measurements using a “split box”
type locator are most inaccurate.
Depth measurements using an Electronic
Locator are only accurate when used in
Conductive Mode.
Depth measurements are for your
information only.
Depth measurements are to the CENTER of
the pipe
![Page 28: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/28.jpg)
Keys to Accurate Locating
If in doubt, hand dig to confirm location of
conductor.
If still in doubt, don’t mark it out.
A guess is the shortest distance between an
accurate locate and a reportable incident.
![Page 29: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/29.jpg)
Review
Mode of use:
Inductive – Least Preferred. Weak signal and will energize other conductors
Conductive – Preferred method. Gives the highest signal strength, longest distance , and better accuracy. Use low frequency.
Remember:
The majority of locating problems stem from the
improper use or positioning of the
transmitter/ground. The transmitter is the “dumb”
end – use it intelligently.
![Page 30: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/30.jpg)
TEMPORARY SURVEY MARKINGS
ELECTRIC
GAS-OIL-STEAM
COMMUNICATIONCATV
POTABLE WATER
IRRIGATION, RECLAIMED WATER, SLURRY LINES
SEWER
PROPOSED EXCAVATION
UTILITY COLOR CODES
![Page 31: Fundamentals of Pipe & Cable Locatingaucsc.com/downloads/F_Pipeline Locating_2019.pdfCopper Pipe –Not as good as coated cable or wire line, but copper, being a good conductor in](https://reader033.fdocuments.us/reader033/viewer/2022052614/6073e6957444e83b0873ee46/html5/thumbnails/31.jpg)
The End