Fundamental Power Couplers for Crab Cavities
description
Transcript of Fundamental Power Couplers for Crab Cavities
Fundamental Power Couplers for Crab Cavities
Possible designs
4 rods
CERN, BE-RF-PM, Eric Montesinos Crab Cavities Power Couplers 17 January 2013 2
Outer line = 62 mm
Inner Line = 27 mm
End shape of the antenna : R 13.5 mm or shape to be
provided
Penetration length from cavity flange : P mm to be given
Cavity port : Stainless Steel 316 LN flange Perpendicular to beam tube Preferably on top of cavity
R13.5
P mm
27
62
Double Ridge Outer line = 62 mm
Inner Line = 27 mm
End shape of the antenna : R 13.5 mm or shape to be
provided
Penetration length from cavity flange : P mm to be given
Cavity port : Stainless Steel 316 LN flange Perpendicular to beam tube Preferably on top of cavity
CERN, BE-RF-PM, Eric Montesinos Crab Cavities Power Couplers 17 January 2013 3
P mm
2762
Quarter Wave Outer line = 62 mm
Inner Line = 27 mm
End shape of the antenna : Special hook with no outer
contact, shape to be given
Penetration length from cavity flange : P mm to be given
Cavity port : Stainless Steel 316 LN flange Perpendicular to beam tube Preferably on top of cavity
CERN, BE-RF-PM, Eric Montesinos Crab Cavities Power Couplers 17 January 2013 4
P mm
2762
Double walled Tube CERN will provide a
common Outer line to connect coupler to cavity : Cavity flange DN63 Cryomodule flange to be
defined Length to be defined
Cavity flange DN63 : Inner diameter = 62 mm Outer Diameter = 114 mm
CERN will also provide specific copper gasket with RF & Vacuum function
CERN, BE-RF-PM, Eric Montesinos Crab Cavities Power Couplers 17 January 2013 5
62 mm
114 mm
tbd
tbd
Windows CERN will provide
windows, bodies and Antennae Length defined regarding
cavity input port
These will be fully equipped with : Vacuum gauge port e- monitor Glass window (arc
detection) Cooling of inner line with
inner caneCERN, BE-RF-PM, Eric Montesinos Crab Cavities Power Couplers 17 January 2013 6
Test Box
CERN will build 2 prototype windows per cavity design
CERN will also build : 3 Test boxes (in order
to keep all couplers clean after RF processing)
6 Double walled Tubes
CERN, BE-RF-PM, Eric Montesinos Crab Cavities Power Couplers 17 January 2013 7
Crab Cavities Power Couplers 17 January 2013 8
Cavity vacuum
As a first step, Windows + DT must be assembled in clean room to the cavity
This closes beam vacuum
It must be an ultra clean processCERN, BE-RF-PM, Eric Montesinos
Cavity and its helium vessel
Coupler to cavity
CERN, BE-RF-PM, Eric Montesinos Crab Cavities Power Couplers 17 January 2013 9
At a later stage, outside clean room, remaining items will be mounted
Cavity vessel will have to be robust enough to stand all these items : Total Weight without air
line : approximately 15 kg
Total Weight with air line (coaxial + WG) : approximately 35 kg
Cryomodule
Bellow between coupler and cryomudule
Cavity and its helium vessel
Schedule 3D drawings for approval : February
2013
2D drawings (EDMS): March 2013
Prototypes ready for tests: March 2014
Couplers ready for cavity assembly : December 2014
CERN, BE-RF-PM, Eric Montesinos Crab Cavities Power Couplers 17 January 2013 10