Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion...
Transcript of Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion...
![Page 1: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/1.jpg)
Fundamental Guide to Industrial Networking
Jeff KordikCTO
Applied Motion Products
![Page 2: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/2.jpg)
A Connected World
• Buy a phone or tablet you expect connectivity
• Your phone can connect to a cell tower, the internet, GPS satellites, the audio system in your car, and your TV set
• If your car isn’t on the internet, your next one will be. Already devices within are on CAN bus
• By 2020 it is expected that 50 billion devices will be interconnected. My phone can talk to the thermostat in my home right now.
![Page 3: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/3.jpg)
Connectivity in Automation
Devices in the automation world also need to talk
• To gather information from sensors
• And send control signal to actuators
Communication standards are essential
• Hardware & software defined protocols
• Get the data there
• Be sure it got there
• Know what it means to both ends
![Page 4: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/4.jpg)
Connectivity in Automation
There are dozens of industrial networking standards
• If you’re starting an application, how do you choose?
• If you are planning to build products, which networks will bring the most success?
• Let’s compare and contrast the most popular industrial networks
• And hopefully learn enough to make an informed choice of which to use
![Page 5: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/5.jpg)
Serial versus Ethernet
Most popular industrial networks started out on serial bus
• 1970’s and 1980’s
• RS-485 or CAN were available at the time to serve as the physical layer: the wires, connectors and IC’s the network is built on
![Page 6: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/6.jpg)
Serial versus Ethernet
Rapid growth of Ethernet in office nets
• Drove Ethernet costs down, speed up• Serial bits rates: 9.6k to 12Mbits/sec
• Ethernet: 100 – 1000 Mbits/sec
• 32 bit IP addressing allows practically unlimited number of nodes
• 16 bit ports allow multiple protocols to “share the wire”
• Most fieldbus standards were adapted to Ethernet in early 2000’s
![Page 7: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/7.jpg)
Serial versus Ethernet
Many popular serial protocols have been updated to run on Ethernet
• Modbus/RTU Modbus/TCP
• DeviceNet EtherNet/IP
• CANopen EtherCAT COE
• Profibus Profinet
• CC-Link CC-Link IE
![Page 8: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/8.jpg)
Serial versus Ethernet
Why migrate to Ethernet?
• More speed
• More nodes
• Mixed protocols on same net
Host
Slave Device
IP 192.168.0.10
UDPTCP port
502
Modbus Application
Slave Device
IP 192.168.0.20
UDP port 2222
TCP port
EtherNet/IP Application
![Page 9: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/9.jpg)
Serial versus Ethernet
• The Industrial Ethernet market is growing by 22% annually
• Serial is growing just 4%
HMS Industrial Networks
48%
46%
6%
Worldwide Industrial Network Usage
Serial
Ethernet
Wireless
![Page 10: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/10.jpg)
Serial Based Networks
HMS Industrial Networks
29%
14%
12%
8%
10%
27%
Relative Popularity of Serial Protocols
Profibus
Modbus RTU
CC-link
DeviceNet
CANopen
Other
![Page 11: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/11.jpg)
Ethernet Based Networks
HMS Industrial Networks
24%
24%
15%
9%
28%
Relative Popularity of Ethernet Protocols
EtherNet/IP
Profinet
EtherCAT
Modbus TCP
Other
![Page 12: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/12.jpg)
Geography
• North America• Rockwell: DeviceNet, EtherNet/IP• Galil, Trio, National Instruments, CTC: EtherCAT
• Europe • Siemens: Profibus, Profinet• Beckhoff: EtherCAT
• Asia• Mitsubishi: CC Link
• Modbus is used everywhere
There is much fragmentation: Choose wisely or choose all
![Page 13: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/13.jpg)
Typical Ethernet Model
• 5 Layers:
UDP TCP
Application
Transport layer
Internet Protocol
Ethernet
Ethernet
Network layer
Data link layer
Physical layer
Application layer
![Page 14: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/14.jpg)
Modbus RTU
• Introduced by Modicon, a PLC maker, in 1979.
• First popular industrial network.
• Ubiquitous, easy to use, cheap.
• Reliable but not fast: 9.6k to 115k bits/sec.
• Tames RS-485 which is otherwise a less than reliable medium
• Good communication standard but not specialized for applications
• Standard organization: The Modbus Organization
![Page 15: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/15.jpg)
• RS-232 is point to point so only one slave device can connect
Modbus RTU Typical Network
Host
TX
RX
Slave Device
![Page 16: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/16.jpg)
• RS-485 allows multiple devices to share the network.
• All devices share a parallel, two wire bidirectional bus
• Up to 247 devices, depending on manufacturer
• Most RS-485 transceivers limit the number of nodes to 32
Modbus RTU Typical Network
Host
Slave Device
TX/RX+
TX/RX-
Slave Device Slave Device Slave Device
![Page 17: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/17.jpg)
• RS-485 can also be implemented as a four wire network.
• Modbus is inherently half duplex so using four wires does not increase network bandwidth
• Modbus masters always wait for a response (or a time out) before sending another message
Modbus RTU Typical Network
Host
Slave Device
TX-RX+
Slave Device Slave Device Slave Device
RX-
TX+
![Page 18: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/18.jpg)
• Simple and low cost
• Most DSP and MCU have built-in UARTs, making Modbus designs incredibly simple and affordable
CPU
Modbus RTU Physical Layer
UART Transceiver network
![Page 19: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/19.jpg)
Modbus TCP
• Introduced in 1999 by Schneider Electric
• Runs on standard Ethernet TCP/IP
• more speed (1000x), more devices on the wire
• Can share the network with other protocols and standard TCP/IP traffic
![Page 20: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/20.jpg)
• IPv4 allows nearly unlimited addressing (232 devices)
• A typical subnet would be limited to 28 or 216 devices
Typical Modbus TCP Network
Host
Slave Device Slave Device Slave Device Slave Device
Ethernet Switch
![Page 21: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/21.jpg)
• IPv4 allows nearly unlimited addressing (232 devices)
• A typical subnet would be limited to 28 or 216 devices
Modbus TCP Dual Port Network
Host
Slave Device
CAT5 or CAT6 cabling
Slave Device Slave Device Slave Device
![Page 22: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/22.jpg)
Modbus TCP Physical Layer
• MAC/PHY can be built into CPU – very common in ARM processors –simple, low cost
• Magjack includes transformers and RJ-45 jack
• For harsh environments, M12 connectors can be used with separate magnetics
CPU MAC Magjack networkPHY
![Page 23: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/23.jpg)
Modbus TCP Physical Layer (Dual Port)
• Dual port Ethernet provides a “daisy chain” network
• Eliminates Ethernet switches
• Useful where a star topology is inconvenient
CPU MAC3 portswitch
from previous nodePHY Magjack
to next nodePHY Magjack
![Page 24: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/24.jpg)
CANopen
• Introduced in 1995
• Standards body: CAN in Automation (CiA)
• Many things defined by standards• CIA301 – communication
• CIA402 – motion
• Standards improve but do not guarantee interoperability.• Example: CIA402 object 606C is motor actual velocity
• But scaling is not defined. Could be RPM, steps/sec, etc.
![Page 25: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/25.jpg)
• All devices share a parallel, two wire bidirectional bus
• Up to 127 devices
CANopen Typical Network
Host
Slave Device
CAN H
CAN L
Slave Device Slave Device Slave Device
![Page 26: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/26.jpg)
CANopen Physical Layer
• Simple and low cost
• Many DSP and MCU have built-in CAN controllers, making CANopen hardware designs inexpensive
CPU CAN controller Transceiver network
![Page 27: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/27.jpg)
EtherCAT COE
• Introduced in 2003 by Beckhoff
• Same issue as CANopen but very real time, intelligent.
• To make up for loose standards definition, devices get “baked in”. Partnering, pay to play
• EtherCAT is opening up. • Not long ago, the only solution was strapping a Beckhoff ASIC to a
processor.
• Now you can get alternate EtherCAT slave controllers
• Or ARM processors with built-in EtherCAT hardware
![Page 28: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/28.jpg)
• Up to 65,535 nodes
Typical EtherCAT Network
Host
Slave Device
CAT5e or CAT6 cabling
Slave Device Slave Device Slave Device
![Page 29: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/29.jpg)
EtherCAT Physical Layer
• Always dual port, no external switches
• Slave node: large footprint design, relatively expensive
CPU
Magjack Incoming trafficPHY
Magjack Outgoing traffic
EtherCAT ASICParallel bus
PHYMII
MII
![Page 30: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/30.jpg)
DeviceNet
• Developed by Allen-Bradley (now Rockwell)
• Introduced in 1994
• Uses CIP protocol on CAN physical and data link layers
• Low cost to implement• Many DSP’s and MCU’s have built-in CAN controllers
• Can transceivers are widely available and inexpensive
![Page 31: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/31.jpg)
• All devices share a parallel, two wire bidirectional bus
• Up to 127 devices
DeviceNet Typical Network
Host
Slave Device
CAN H
CAN L
Slave Device Slave Device Slave Device
![Page 32: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/32.jpg)
DeviceNet Model
CIP Protocol
Transport layerDeviceNet Transport
CAN
DeviceNet Physical
Network layer
Data link layer
Physical layer
Slave Device Application
Application layer
![Page 33: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/33.jpg)
DeviceNet Physical Layer
• Simple and low cost
• Many DSP and MCU have built-in CAN controllers, making DeviceNethardware designs inexpensive
CPU CAN controller Transceiver network
![Page 34: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/34.jpg)
EtherNet/IP
• Developed by Allen-Bradley (now Rockwell)
• Introduced in 2001
• Standards organization: ODVA
• Runs on standard Ethernet
• Uses Common Industrial Protocol (CIP)
• Uses TCP transport for explicit messages
• UDP for fast, cyclical implicit messaging
![Page 35: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/35.jpg)
• IPv4 allows nearly unlimited addressing (232 devices)
• A typical subnet would be limited to 28 or 216 devices
Typical EtherNet/IP Network
Host
Slave Device Slave Device Slave Device Slave Device
Ethernet Switch
Dual port solutions are also popular
![Page 36: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/36.jpg)
EtherNet/IP Network Model
UDP/TCP
CIP Protocol
Transport layer
Internet Protocol
Ethernet
Ethernet
Network layer
Data link layer
Physical layer
EtherNet/IP
Slave Device Application
Application layer
![Page 37: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/37.jpg)
EtherNet/IP Physical Layer
• MAC/PHY can be built into CPU – very common in ARM processors –simple, low cost
• Magjack includes transformers and RJ-45 jack
• For harsh environments, M12 connectors can be used with separate magnetics
CPU MAC Magjack networkPHY
Dual port solutions are also popular
![Page 38: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/38.jpg)
Profibus DP
• Devised in Germany in 1987
• Primary controller: Siemens
• Popular in Europe
• Enhanced RS-485 physical layer
• Speeds to 12 Mbits
• Requires ASIC for data link layer
![Page 39: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/39.jpg)
• Enhanced RS-485 allows multiple devices to share the network at high speeds
• All devices share a parallel, two wire bidirectional bus
• Up to 32 devices per segment
Profibus DP Typical Network
Host
Slave Device
TX/RX+
TX/RX-
Slave Device Slave Device Slave Device
![Page 40: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/40.jpg)
Profibus DP Network Model
DPVx Protocol
FDL
Enhanced RS-485
Data link layer
Physical layer
Slave Device Application
Application layer
![Page 41: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/41.jpg)
• At least one ARM CPU is available with a built-in Profibussubsystem,
• eliminates need for ASIC
• eliminates potential need for parallel bus
Profibus DP Physical Layer
ProfibusASIC
Enhanced RS-485Transceiver
network
Parallel or SPI bus
CPU
![Page 42: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/42.jpg)
Profinet IO
• Introduced in 2003 by PI working group
• PI North America is standards organization
• Built on standard Ethernet
• Uses UDP and TCP transport
• Can “share the wire” with other protocols
![Page 43: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/43.jpg)
Profinet IO Typical Network
• Thousands of nodes are possible
Host
Slave Device Slave Device Slave Device Slave Device
Ethernet Switch
![Page 44: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/44.jpg)
Profinet IO Network Model
TCPUDP Transport layer
Internet Protocol
Ethernet
Ethernet
Network layer
Data link layer
Physical layer
Profinet IO
Slave Device Application
Application layer
![Page 45: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/45.jpg)
Profinet IO Physical Layer
CPU MAC Magjack networkPHY
![Page 46: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/46.jpg)
Summary
serial bus Ethernet
Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP EtherNet/IP ProfiNet IO EtherCAT COE
year introduced 1979 1994 1987 1995 1999 2001 2003 2003
max physical layer speed (Mbits/sec) 0.1 0.5 12 1 1000 1000 1000 100
max nodes32 typ
254 max 6432/segment, 126
max 127
share wire?
cyclic
motion specific option ProfiDrive CIA402CIPsync,
CIPmotion CIA402
standards body Modbus Org ODVA PNO, PI CiA Modbus Org ODVA PI ETG
controllers many many many mainly Rockwell Beckhoff, SiemensBeckhoff, Trio, Galil, National
Instruments, others
Relative cost of slave node 1 3 7 3 5 7 6 10
![Page 47: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/47.jpg)
Implementation Options
How do I go about designing a fieldbus node?
• If the device already has a fieldbus option, consider using an external gateway to convert the protocol
• Use HMS Anybus module to device can be adapted to many popular protocols
• Buy a commercial software stack (RTA)• Design your own physical layer
![Page 48: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/48.jpg)
Implementation Options
Pay to Play
• Some standards require you to pay an annual fee• For access to written standards
• For test tool subscriptions
• For a vendor ID
• Additional fees apply for• Conformance testing
• Plug fests
![Page 49: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/49.jpg)
Other Considerations
Distributed Intelligence
• A stored program in each node can reduce needed bandwidth for non-tightly coordinated axes
• Individual nodes can read I/O, make decisions, execute motion
• Can be cost effective because stored programming in an already needed CPU costs little (beyond software development)
• Still has benefit of real time connectivity, streaming set up, feedback, data logging
![Page 50: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/50.jpg)
Other Considerations
Step & Direction
• Controller sends step pulses and a direction signal to each motion node
Advantages
• Motion can be tightly coordinated
• Very low slave cost
Slave Device
Controller
Step,dir,fault
Slave Device Slave Device Slave Device
![Page 51: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/51.jpg)
Other Considerations
Step & Direction
Disadvantages
• No certainty if signals reached the node
• Only feedback is fault signal.
• No status monitoring or data logging
Slave Device
Controller
Step,dir,fault
Slave Device Slave Device Slave Device
![Page 52: Fundamental Guide to Industrial Networking Industrial Networking Jeff Kordik CTO Applied Motion Products. A Connected World ... Modbus RTU DeviceNet Profibus DP CANopen Modbus TCP](https://reader030.fdocuments.us/reader030/viewer/2022040121/5ed7166a2da71b386924009d/html5/thumbnails/52.jpg)
Contact
Jeff Kordik
CTO
Applied Motion Products
Watsonville, CA 95076
USA
(800) 525-1609