FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES
-
Upload
riseagrant -
Category
Business
-
view
1.122 -
download
3
Transcript of FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES
![Page 1: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/1.jpg)
FUNDAMENTAL ACOUSTICSAND
WIND TURBINE NOISE ISSUES
Prof. Gopu R. Potty, Ph.D.Department of Ocean Engineering
University of Rhode IslandNarragansett, RI 02882
![Page 2: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/2.jpg)
Develop general guidelines on allowable sound level thresholds and appropriate setbacks
Major Task
![Page 3: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/3.jpg)
Outline
• Acoustic fundamentals
• Wind turbine as a noise source
• Review of noise regulations
![Page 4: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/4.jpg)
Sound Waves
Sound is a pressure wave
Sounds have different frequenciesHuman hearing: 20 Hz to 20 kHzLess than 20 Hz - infrasound
Intensity is the average amountof sound power transmitted through a unit area in a specified direction. The unit of intensity is watts per square meter.
![Page 5: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/5.jpg)
Decibel
•The decibel (dB) is a logarithmic comparison of intensities.•Named for Alexander Graham Bell
212 W/m101intensity acoustic Reference −= x⎭⎬⎫
⎩⎨⎧
Intensity ReferenceIntensity Acousticlog10Level =
![Page 6: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/6.jpg)
Decibel level of some sounds
http://www.redferret.net/?p=9346
![Page 7: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/7.jpg)
Adding decibels• Let’s say we had 3 sources of sound at 70, 80 and 90 dB each, what is the total level?
• We need to convert the individual levels into raw intensities and add them
• The sum thus calculated (expressed in dB) in this case is 90.5 dB
Two turbines produce 3 dB more than one turbine
![Page 8: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/8.jpg)
SPL= 20 log Pressure of an acoustic signalreference pressure
The units of L are dB relative to the reference pressure.
The reference pressure is20 micropascals based onhearing tests of 16 million menin WW2.
This corresponds to an Intensity of 1x10-12 W/m2.
Sound Pressure Level (SPL)
![Page 9: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/9.jpg)
Source Level SL
SL is defined to be
20 log Pressure of source at 1 mreference pressure
The units of SL are dB relative to Reference pressure of 20 micropascals at 1 meter.
SL referenced at 1 meter
Quantifies the strength of the source !!!!
(Rogers et al., 2006)
![Page 10: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/10.jpg)
Acoustics at a distance
• We can predict the sound pressure level of an acoustic signal at a distance.
L = SL - TL
L = Sound Pressure LevelSL = Source LevelTL = Transmission Loss
Nascar fans in the front row are exposed to more intense soundthan the fans in back row due to transmission loss.
![Page 11: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/11.jpg)
Transmission Loss• Transmission Loss TL (aka propagation loss) describes the weakening of sound between a point 1 meter from the source and a point at a distance r meters.
• It is the ratio of intensity at any range ‘r’ to intensity at 1 m
TL = -10 log Intensity at r meters
Intensity at 1 meter
(Rogers et al., 2006)
![Page 12: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/12.jpg)
• Geometrical spreading• Absorption• Scattering
– Volumetric scattering, turbulence– Groundcover, trees, structures
• Total loss = Geometrical Spreading +Absorption +Scattering
Transmission Loss Components
Absorption coefft. expressed in dB/km or dB/m
Absorption a function of• Temperature• Humidity• Frequency
![Page 13: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/13.jpg)
Geometrical Spreading: Spherical
Weakening of the acoustic intensity due to spreading
Related to the surface areas of spheres (or hemi-spheres) at two ranges.
Doubling the distance to the turbine reduces the SPL by 6dB
![Page 14: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/14.jpg)
Closer is Usually Louder
Nascar car with a sourcelevel of 130 dB
at 10 meters, the level would be 110 dB
at 100 meters, the level would be 90 dB
![Page 15: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/15.jpg)
The Hearing Threshold CurveFrom: Yost
Listeners can detect sounds as low as 0 dB SPL at 3 kHz, but require 40 dB SPL at 60 hertz (an amplitude increase of 100)
The range of human hearing is generally considered to be 20 Hz to 20 kHz, but it is far more sensitive to sounds between 1 kHz and 4 kHz.
![Page 16: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/16.jpg)
A and C Weightings
• A weighting filters out the low frequencies and slightly emphasizes the upper middle frequencies around 2‐3 kHz. By comparison C weighting is almost unweighted, or no filtering at all.
• As a general rule, C weighting is used for protection against very intense sounds while A weighting is used for less intense sounds and predicts annoyance fairly well.
http://www.e-a-r.com/pdf/hearingcons/FAQdba.pdf
![Page 17: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/17.jpg)
Wind NoiseWind turbines differ in several respects from other sources of community noises
Modern wind turbines mainly emit noise from turbulence at the trailing edge of the rotor blades.
The turbine sound power level varies with the wind speed at hub height.
The sound is amplitude modulated with the rotation rate of the rotor blades, due to the variation in wind speed with height and the reduction in wind speed near the tower.
Amplitude-modulated sound is more easily perceived than is constant-level sound and has been found to be more annoying
Sound that occurs unpredictably and uncontrollably is more annoying than other sounds
![Page 18: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/18.jpg)
Wind Noise
Wind turbines are tall and highly visible, often being placed in open, rural areas with low levels of background sound.
Consequently, wind turbines are sometimes regarded as visible and audible intruders in otherwise unspoiled environments.
Furthermore, the moving rotor blades draw attention, possibly enhancing the perception of sound in a multi-modal effect
![Page 19: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/19.jpg)
The sources of noise emitted from operating wind turbines can be divided into two categories:• mechanical and • aerodynamic.
The primary sources of mechanical noise are the gearbox and the generator.
The highest contributor to the total sound power from a turbine is the aerodynamic noise, which is produced by the flow of air over the blades.
Wind Turbine Noise Sources
![Page 20: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/20.jpg)
Portsmouth Wind Turbine(July/Aug 2009)
Measured at a distance of 65 meters. Units are dB re 20 μPa2 in a 1/3-octave band
![Page 21: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/21.jpg)
Portsmouth Wind Turbine
Trial 1 Trial 2: Trial 3: Trial 4: Trial 5: Trial 6:
59.27 59.30 59.40 59.12 59.36 59.41
Science Fair Project (Chitanya Gopu- SK High)
0 100 200 300 400 500 600 700 800 900 100020
30
40
50
60
70
80
90
100
SPL
dBA
distance from tower (m)
Simple hemispherical propagation model
11/30
6:50 AM
11/30
10:31
AM
11/30
3:30
PM
11/30
8:30
PM
12/01
5:30
AM
56.7 54.4 54.7 51.3 49.2
At 0.5 km (Heather Rhodes)
sound of the traffic from Rt. 24 was dominant !!!!
A
B
![Page 22: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/22.jpg)
Vestas V‐52 850 kW Wind Turbine; 10 m/s wind speed; 80 m from the turbine (Leventhal)
Frequency (Hz)
Leve
l (dB
) tonals
![Page 23: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/23.jpg)
Low Frequency Noise• Low frequency noise (20‐100 Hz)
and infrasound (less than 20 Hz) are issues that are frequently raised as concerns associated with wind farm developments
• Usually G‐weighted• Perceived a mixture of tactile and
auditory sensations• Threshold of hearing at 10 Hz very
high (~100 dB G)• Low frequency noise generation is
generally confined to turbines whose rotors operate downwind of the support tower – a downwind machine.
Sources for low-frequency noise are either of a natural origin, such as air turbulence wind, thunder, ocean waves, volcanic eruptions, and earthquakes or of human origin such as heating, ventilation, air-conditioning systems, machinery, cars, trucks, airplanes, and loudspeaker systems
![Page 24: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/24.jpg)
Infrasound Measurements
From: Jorgen Jakobsen, journal of Low Frequency Noise, Vibration and Active Control, 24(3), 2005
Note the high background noise level below 5 Hz
10 dB
![Page 25: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/25.jpg)
Low frequency sound (10‐160 Hz)
![Page 26: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/26.jpg)
‘Swish’ Noise• Swish‐swish sound is amplitude modulation at blade passing frequencies of higher frequency blade tip turbulence
• Does not contain low frequencies
• Diminishes with distance• Blurs with multiple turbines
Time
![Page 27: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/27.jpg)
Noise Varies with Wind Speed
Downwind at 34.5 meters
Note the higher noise levels at low wind speeds
![Page 28: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/28.jpg)
Wind Noise Regulations
Most international and various states in USA set a base noise level for low wind speeds.
Many regulations specify a night time level of 35 dBA in a rural location.
To prevent the adverse impacts from the increased noise of wind turbine generators at high wind conditions, the increased noise levels must also be compared to the corresponding background noise at any location of interest.
For example some codes specify that the wind farm noise doesn’t exceed the background noise by more than 5 dBA at higher wind speeds.
![Page 29: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/29.jpg)
Typical Guidelines for Pure Tones
A pure tone is defined to exist if the 1/3rd octave band sound pressure level in the band, including the tone, exceeds the arithmetic average of the two contiguous 1/3 octave bands by
•5 dBA for center frequencies of 500 Hz and above•8 dBA for center frequencies between 160 Hz and 400 Hz•15 dBA for center frequencies less than or equal to 125 Hz
Most of the codes penalize tonals. For example, Huron County, MI, specifies that when steady pure tone is present, the standard for audible noise shall be reduced by 5 dBA.
![Page 30: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/30.jpg)
ISO 1996-1971 guidelines
A temperature increase (an “inversion”) with altitude often occurs at night and this causes sound to be refracted downward
On an expedition to Venezuela in 1899, Baron von Humboldt observed much better sound transmission from a waterfall on the Orinoco River at night than during the day !!.
Gabrielson, Acoustic Today, 2006
Lower night time limits !!!
![Page 31: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/31.jpg)
* LAeq
WHO guidelines
![Page 32: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/32.jpg)
U.K, France, South Australia and Canada
Canada
![Page 33: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/33.jpg)
Denmark
Lp= Sound Pressure level
![Page 34: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/34.jpg)
Massachusetts Dept. Env. Protection Criteria
A noise source will be considered in violation if the source results in:
• An increase in the broadband sound pressure level of more than 10 dBA above ambient or
• Pure tone condition: when any octave band level exceeds two adjacent band levels by 3 dB
![Page 35: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/35.jpg)
Study Plan
• Make repeated sound level measurements using sound level meter (during day and night) near existing turbines in RI.
• Compare this to sound level models • Make ambient sound measurements at locations of
interest.• Develop a weight to reflect noise considerations which
can be incorporated into TDI calculations• Develop general guidelines on allowable sound level
thresholds
![Page 36: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/36.jpg)
Need to account for perception !!!
Annoyance towards wind turbine sound is enhanced by the •high visibility of the noise source, •swishing quality of the sound,•its unpredictable occurrence, •continuation of the sound at night.
Dutch and Swedish studies (Pedersen et al., J. Acoust. Soc. Am., Vol. 126, No. 2, August 2009
LDEN dB(A)
Dose-Response Relationship Studies
![Page 37: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/37.jpg)
Questions
Audio: winds 20-30 mph, 50 ft tower, 50 ft from tower, wind slows down then speeds up
![Page 38: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/38.jpg)
Extra slides
![Page 39: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/39.jpg)
Perception of Sound from Wind Turbines
Annoyance towards wind turbine sound is enhanced by the •high visibility of the noise source, •swishing quality of the sound,•its unpredictable occurrence, •continuation of the sound at night.
![Page 40: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/40.jpg)
Perception of Sound from Wind Turbines
Annoyance was highest in what was classified as built-up area (mostly small towns and villages)Could be interpreted as an effect of place attachment In this view, new technical devices being deemed not beneficial for the living environment induce a negative reaction .This theory cannot, however, be confirmed from the present data set.
![Page 41: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/41.jpg)
Perception of Sound from Wind Turbines
Annoyance was found to be significantly higher in the Dutch study in the 35–40-dBA interval.The perceived difference could be due to the larger wind turbines included in the Dutch study.
![Page 42: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/42.jpg)
Perception of Sound from Wind Turbines
Noise from wind turbines was found to be more annoying than other sources.Percentage of people annoyed lies between noise from aircraft and from shunting yards.Like aircraft, wind turbines are elevated sound sources visible from afar and hence intrude both visually and aurally into private spaceWind turbine noise (like shunting yard noise) ceases at night
![Page 43: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/43.jpg)
Background Wind Noise
•Masks wind turbine noise•Increases with wind speed•Typical levels 30-45 dBA
wind speed (m/s)
![Page 44: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/44.jpg)
Sound Pressure Levels
![Page 45: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/45.jpg)
Directivity(Wei Jun Zhu)
Single turbine at the centerReceiver positions range from 60 to 200 m
Wind direction
![Page 46: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/46.jpg)
Summary of Infrasound Measurements
From: Jorgen Jakobsen, journal of Low Frequency Noise, Vibration and Active Control, 24(3), 2005
![Page 47: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/47.jpg)
Harris, Handbook of Acoustical Measurements and Noise Control, 1998.
Air Absorption of Sound
Absorption a function of• Temperature• Humidity• Frequency
Absorption coefft. expressed in dB/km
![Page 48: FUNDAMENTAL ACOUSTICS AND WIND TURBINE NOISE ISSUES](https://reader034.fdocuments.us/reader034/viewer/2022052523/55620f7bd8b42af2128b4cb9/html5/thumbnails/48.jpg)
Auditory Perception
• A 1 dB change in SPL is below the level of human perception
• For a sound to double in loudness, an increase of 10 dB is required
• A 3 dB change in SPL level is minimum level of human perception (it is just barely noticeable)
• An SPL of 140 dB is the threshold of pain
From: Acoustic Analysis Dartmouth DPW Wind Project (Atlantic Design Engineers, LLC)