Fully Integrated 18” MasterCool
F 2411 Vi
F 2461 Vi / F 2471 Vi
8mieleusa.comSpecification Sheets TRS 05202019 Please note: This information is subject to change
Shown: F 2471 Vi merged with K 2801 Vi
![Page 2: Fully Integrated 18” MasterCool · If the adjoining cabinets are taller than the height of machine (HOM) - the front panel may be extended accordingly. Simply maintain the toekick](https://reader033.fdocuments.us/reader033/viewer/2022041516/5e2b77037b361325ee1e237d/html5/thumbnails/2.jpg)
Fully Integrated 18” MasterCool
Please note the following:• This specification sheet is for a single built-in unit.• When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specification sheet. *If design calls for a partition less than 6 5/16” (160 mm) the left unit’s cutout will require an additional 1/8” (3 mm) to the width to allow installation of the Heating Mat/Merge Kit.
SPECIFICATIONS
Overall Unit Dimensions 173/4” (451 mm) W x 833/4”- 853/16” (2127 - 2164 mm) H x 24” (610 mm) D [Depth does not include door panel]
Niche
Minimum Cabinet Niche Opening 18” (458 mm) W* x 84” - 853/16” (2134 - 2164 mm) H x 243/4” (629 mm) D
Electrical F 24x1 Vi
Electrical Requirements110V / 120V, 60Hz, 15 Amps
In the case of side-by-side installations, a separate outlet must be used for each appliance.
Power Cord NEMA 5-15 plug, 5 ft (1.52 m)
Plumbing F 24x1 Vi
Water Supply Requirements
Connect to a cold water supply only. Do not connect to a low-mineral or a reverse osmosis system. Must be connected to a shut-off valve. The water shut-off valve must be accessible after installation. The water pressure must be between 29 psi (2 bar) and 116 psi (8 bar). If the pressure is higher than 120 psi (8.3 bar), a pressure reducing valve must be installed.
Water Connection Line Standard 1/4” O.D flexible water line. The maximum outer diameter of the water pipe (without fittings): 3/8” (10 mm). Water line is not included.
Shipping F 2411 Vi F 2461 Vi / F 2471 Vi
Shipping Weight 306 lbs (139 kg) 328 lbs (149 kg)
Shipping Dimensions 211/16” (535 mm) W x 841/4” (1,240 mm) H x 297/8” (759 mm) D
Support
Call Miele (800) 999-1360
Miele Website 8www.mieleusa.com
20/20 Link 82020technologies.com
F 2411 Vi (Left Hinged)Item 37241101USA
Page 2 of 9
F 2461 Vi (Right Hinged)Item 37246101USA
F 2471 Vi (Left Hinged)Item 37247101USA
![Page 3: Fully Integrated 18” MasterCool · If the adjoining cabinets are taller than the height of machine (HOM) - the front panel may be extended accordingly. Simply maintain the toekick](https://reader033.fdocuments.us/reader033/viewer/2022041516/5e2b77037b361325ee1e237d/html5/thumbnails/3.jpg)
CUTOUT DIMENSIONS
• Niche depth assumes a 3/4” (19 mm) panel, please adjust according to custom panel thickness
Fully Integrated 18” MasterCool
CUTOUT DETAILS
• The electrical connection must not be positioned higher than 9” (228.6 mm) above the floor.
• The 1/4” (6.4 mm) plumbed water connection should not be positioned higher than 2” (50.8 mm) above the floor.
Notes:In case of an emergency the electrical outlet must be easily accessible and must not be concealed behind the appliance.
Page 3 of 9
![Page 4: Fully Integrated 18” MasterCool · If the adjoining cabinets are taller than the height of machine (HOM) - the front panel may be extended accordingly. Simply maintain the toekick](https://reader033.fdocuments.us/reader033/viewer/2022041516/5e2b77037b361325ee1e237d/html5/thumbnails/4.jpg)
POWER SUPPLY AND WATER CONNECTION
Fully Integrated 18” MasterCool
Water connection is located in front of unit.1/4” compression fitting is needed.
Electrical - 5 foot (1.52 m) - 120 Volt - 15 Amp - NEMA 5-15 molded plugWater line - 1/4” flexible water line - not included
Rear View Front View
Electrical Connection
Side View
Page 4 of 9
![Page 5: Fully Integrated 18” MasterCool · If the adjoining cabinets are taller than the height of machine (HOM) - the front panel may be extended accordingly. Simply maintain the toekick](https://reader033.fdocuments.us/reader033/viewer/2022041516/5e2b77037b361325ee1e237d/html5/thumbnails/5.jpg)
CUSTOM PANEL INSTALLATIONS
Width: 29 3/4" in all cases
Thickness: Minimum 3/4" outside frame
Height: Determined using the following calculation:
Panel Height = HOC - TKH
HOC = Total height of cabinet or side panelTKH = Toe-kick height
Note: Finish back side of panels to insure appearancePanel may extend above unit. This is notconsidered in height calculation
Maximum panel weight: 105.8 Pounds
MieleFully Integrated
Freezer
TKH
HO
C
Pane
l Hei
ght
These units do not come equipped with a front panel. They are designed to accept a custom door panel supplied bythe cabinet maker. Miele has a unique panel integration system which allows the panels to align with the surroundingcabinets.
Panel size is determined in the following manner:
Panel NotesIf the adjoining cabinets are taller than the height of machine (HOM) - the front panel may be extended accordingly.Simply maintain the toekick height and extend the panel the needed distance.
Adjoining cabinet
Machine
Extended Panel
123 Pounds
Minimum 17 3/4” (451 mm)
Minimum 3/4” (19 mm) outside frame
Fully Integrated 18” MasterCool | F 2411 Vi
Page 5 of 9
![Page 6: Fully Integrated 18” MasterCool · If the adjoining cabinets are taller than the height of machine (HOM) - the front panel may be extended accordingly. Simply maintain the toekick](https://reader033.fdocuments.us/reader033/viewer/2022041516/5e2b77037b361325ee1e237d/html5/thumbnails/6.jpg)
Fully Integrated 18” MasterCool | F 2411 Vi
DOOR PANEL DIMENSIONSKFP1804 - Door Panel
Available as an accessoryfor the following models:• F 2411 Vi
Page 6 of 9
![Page 7: Fully Integrated 18” MasterCool · If the adjoining cabinets are taller than the height of machine (HOM) - the front panel may be extended accordingly. Simply maintain the toekick](https://reader033.fdocuments.us/reader033/viewer/2022041516/5e2b77037b361325ee1e237d/html5/thumbnails/7.jpg)
CUSTOM PANEL INSTALLATIONS
Fully Integrated 18” MasterCool | F 2461 Vi / F 2471 Vi
Page 7 of 9
CUSTOM PANEL INSTALLATIONS
Width: 17 3/4" in all cases
Thickness: Minimum 3/4" outside frame
Height: Determined using the following calculation:
Panel Height = HOC - TKH
HOC = Total height of cabinet or side panelTKH = Toe-kick height
Note: Finish back side of panels to insure appearancePanel may extend above unit. This is notconsidered in height calculation
Maximum panel weight: 143.3 Pounds
MieleFully Integrated
Freezer
TKH
HO
C
Pane
l Hei
ght
These units do not come equipped with a front panel. They are designed to accept a custom door panel supplied bythe cabinet maker. Miele has a unique panel integration system which allows the panels to align with the surroundingcabinets.
Panel size is determined in the following manner:
Panel NotesIf the adjoining cabinets are taller than the height of machine (HOM) - the front panel may be extended accordingly.Simply maintain the toekick height and extend the panel the needed distance.
Adjoining cabinet
Machine
Extended Panel
143 Pounds
17 3/4” (451 mm) in all cases
Minimum 3/4” (19 mm) outside frame
Pan
el "
B"
Hei
ght
Width: 29 3/4" in all casesThickness: Minumum 3/4" outside frame
Standard Upper Panel Height: 53 5/16"
Note: Finish back side of panels to insure appearancePanel may extend above unit. This is notconsidered in height calculation
Upper Maximum panel weight : 103.6 Pounds
Lower Panel Height: Use the following calculation:
Panel Height = HOM - 53 9/16 - TKH
HOM = Total height of machine. Can be adjusted tomatch adjoining cabinets - typically 84"HOM is adjustable between 83 1/2" - 85 3/8"
TKH = Toe-kick height (2" - 8 3/8")
Lower Maximum panel weight: 22 Pounds
Upper Panel
TKH
HO
M
Pan
el H
eigh
t
These units do not come equipped with a front panel. They are designed to accept a custom door panel supplied bythe cabinet maker. Miele has a unique panel integration system which allows the panels to align with the surroundingcabinets.
Panel size is determined in the following manner:
Lower Panel
Upper Panel NotesIf the adjoining cabinets are taller than the height of machine (HOM) - the upper panel may be extended accordingly.Find the difference between height of the adjoining cabinets and the height of machine (HOM) and add to 53 5/16"
Adjoining cabinet
Machine
Extended Panel Example:Ajoining cabinet height: 87"Height of machine: 84"Difference: 3"
Extended panel height: 56 5/16"
Width: 17 3/4" in all cases
Thickness: Minimum 3/4" outside frame
Height: Determined using the following calculation:
Panel Height = HOC - TKH
HOC = Total height of cabinet or side panelTKH = Toe-kick height
Note: Finish back side of panels to insure appearancePanel may extend above unit. This is notconsidered in height calculation
Maximum panel weight: 143.3 Pounds
MieleFully Integrated
Freezer
TKH
HO
C
Pane
l Hei
ght
These units do not come equipped with a front panel. They are designed to accept a custom door panel supplied bythe cabinet maker. Miele has a unique panel integration system which allows the panels to align with the surroundingcabinets.
Panel size is determined in the following manner:
Panel NotesIf the adjoining cabinets are taller than the height of machine (HOM) - the front panel may be extended accordingly.Simply maintain the toekick height and extend the panel the needed distance.
Adjoining cabinet
Machine
Extended Panel
![Page 8: Fully Integrated 18” MasterCool · If the adjoining cabinets are taller than the height of machine (HOM) - the front panel may be extended accordingly. Simply maintain the toekick](https://reader033.fdocuments.us/reader033/viewer/2022041516/5e2b77037b361325ee1e237d/html5/thumbnails/8.jpg)
Fully Integrated 18” MasterCool | F 2461 Vi / F 2471 Vi
DOOR PANEL DIMENSIONS & DISPENSER CUTOUTKFP 1844 - Door Panel
Available as an accessoryfor the following models:• F 2461 Vi• F 2471 Vi
Page 8 of 9
![Page 9: Fully Integrated 18” MasterCool · If the adjoining cabinets are taller than the height of machine (HOM) - the front panel may be extended accordingly. Simply maintain the toekick](https://reader033.fdocuments.us/reader033/viewer/2022041516/5e2b77037b361325ee1e237d/html5/thumbnails/9.jpg)
0-1/8"
Front Panel
1"1-1/4"
1-1/2"
0-3/4"
0-3/4"
1-1/4"1-1/2"1-3/4"2" 1"
Cabinet Front
0-3/4"
1"1-1/4"1-1/2"
0-1/8"
FrontPanel
0-3/4"
1-1/4"1-1/2"1-3/4" 1"
Cabinet Front
rooD °511rooD °09
snoitpo ssenkcihTsnoitpo ssenkcihT
Door Swing
NOTE: Additional space needed depending onthickness of front panels and handle used
38 11
/16"
7/16"
Door Swing
16 7/8"MAX
NOTE: Additional space needed depending onthickness of front panels and handle used
HINGING DETAILS 115° OPENING
3”(76.2mm)
1-3/4”(44.5mm)
1-3/8”(35mm
)1-1/6” (29.6m
m)
1/4”(6.4mm
)17/24” (18m
m)
2-1/24”(52mm)2-1/3” (59mm)2-5/8” (67mm)
3”(76.2mm)
1-3/4”(44.5mm)
1-3/8”(35mm
)1-1/6” (29.6m
m)
1/4”(6.4mm
)17/24” (18m
m)
2-1/24”(52mm)2-1/3” (59mm)2-5/8” (67mm)
0-3/4” (19 mm
)1” (25 m
m)
1-1/4” (32 mm
)1-1/2” (38 m
m)
1-3/4” (44 mm
)
1-1/2” (38 mm)
1-1/4” (32 mm)
1” (25 mm)
0-3/4” (19 mm)
0-1/8” (3 mm)
Fully Integrated 18” MasterCool
Available for the following models:• F 24x1 Vi
Page 9 of 9
0-1/8"
Front Panel
1"1-1/4"
1-1/2"
0-3/4"
0-3/4"
1-1/4"1-1/2"1-3/4"2" 1"
Cabinet Front0-3/4"
1"1-1/4"1-1/2"
0-1/8"
FrontPanel
0-3/4"
1-1/4"1-1/2"1-3/4" 1"
Cabinet Front
rooD °511rooD °09
snoitpo ssenkcihTsnoitpo ssenkcihT
Door Swing
NOTE: Additional space needed depending onthickness of front panels and handle used
38 1
1/16
"
7/16"
Door Swing
16 7/8"MAX
NOTE: Additional space needed depending onthickness of front panels and handle used
DOOR SWING AT 115° OPENING 11 3/4”(298 mm)
Max