4
PDH14-K “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS *Exceeding recommended mounting height may compromise performance. U L C US R Connection Diagram (30" - 48" Widths) Recommended Mounting Height Electrical/Mechanical Specifications For Blower Units Model Volts Amps* Hz RPM CFM [email protected]" Equivalent CFM CFM [email protected]" CFM [email protected]" CFM [email protected]" Minimum Round Duct Size Sones # K250 (Top Vent) 115 3.2 60 1550 250 375 223 220 190 7" (38 in. 2 ) 7.4 * Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48"). • Because the Magic Lung ® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung ® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung ® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0310A (Front View) (Top View) PDH14-K OPTIONAL DUCT COVER 7" Round

Transcript of Full Specification Set - Small Business

PDH14-K “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes.

EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS

*Exceeding recommended mounting height may

compromise performance.

ULC USR

Connection Diagram (30" - 48" Widths) RecommendedMounting Height

Electrical/Mechanical Specifications For Blower Units

Model Volts Amps* Hz RPM [email protected]" Equivalent CFM• CFM

[email protected]"CFM

[email protected]"CFM

[email protected]"Minimum Round

Duct Size Sones#

K250 (Top Vent) 115 3.2 60 1550 250 375 223 220 190 7" (38 in.2) 7.4* Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48").• BecausetheMagicLung®blowerusescentrifugalfiltrationratherthanconventionalbaffleormeshfilters,theMagicLung®blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmoreefficientlythanotherthanotherfiltrationsystems.WhencomparingtheMagicLung®withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.

# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0310A

(Front View)

(Top View)

PDH14-K

OPTIONAL DUCT

COVER

7" Round

PD14/PDH14/SLD14/SLDH14 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes.

Connection Diagram (36”- 48” Widths)

EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS

30” model is limited to B100 single blower only

*Exceeding recommended mounting height may

compromise performance.

CenterlineOf Hood

Electrical

6" Outlet

Wall Side

VentHole

1 7⁄8”1 ¾”

5 ¼”

Electrical

1 ¾”

Centerlineof Hood

8” Outlet

VentHoles

5 ¼”5 ½”Wall Side

BlowerExhaustOutlet

5"

14"

6" Round

14"

BlowerExhaustOutlet

5"8" Round

ULC USR

OPTIONAL DUCT

COVER

PD14/PDH14 SLD14/SLDH14

Connection Diagram (30" - 48" Widths) RecommendedMounting Height

(Front View)300 CFM B100 Single Blower(Top View)

(Front View)600 CFM B200 Dual Blower(Top View)

OPTIONAL DUCT

COVER

Electrical/Mechanical Specifications For Blower Units

Model Volts Amps* Hz RPM [email protected]" Equivalent CFM• CFM

[email protected]"CFM

[email protected]"CFM

[email protected]"Minimum Round

Duct Size Sones#

B100 Single 115 1.5 60 1550 300 450 273 245 225 6" (28 in.2) 5.4B200 Dual 115 2.9 60 1550 600 900 531 480 430 8" (50 in.2) 6.5

* Add0.5ampforeachhalogenlight.Hoodisavailablewithasinglefluorescentlightorwithhalogenlights(2lights:30"-41",3lights:42"-48").• BecausetheMagicLung®blowerusescentrifugalfiltrationratherthanconventionalbaffleormeshfilters,theMagicLung®blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmoreefficientlythanotherthanotherfiltrationsystems.WhencomparingtheMagicLung®withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.

# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0210A

EP(X)18/EP(X)H18/NEP(X)18/NEP(X)H18/SEP(X)18/SEP(X)H18 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes.

EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS

(X) in part number indicates 27” depth

600 CFM B200 Dual Blower(Top View)

(Front View)

*Exceeding recommended mounting height may

compromise performance.

Electrical

1 ¾”

Centerlineof Hood

8” Outlet

VentHoles

5 ¼”5 ½”Wall Side

18"

Blower ExhaustOutlet

9"8" Round

ULC USR

NEP(X)18/NEP(X)H18EP(X)18/EP(X)H18 SEP(X)18/SEP(X)H18

Connection Diagram (36" - 48" Widths) RecommendedMounting Height*

Electrical/Mechanical Specifications For Blower Units

Model Volts Amps* Hz RPM [email protected]" Equivalent CFM• CFM

[email protected]"CFM

[email protected]"CFM

[email protected]"Minimum Round

Duct Size Sones#

B200 Dual 115 2.9 60 1550 600 900 531 480 430 8" (50 in.2) 6.5* Add0.5ampforeachhalogenlight.Hoodisavailablewithasinglefluorescentlightorwithhalogenlights(2lights:30"-41",3lights:42"-48").• BecausetheMagicLung®blowerusescentrifugalfiltrationratherthanconventionalbaffleormeshfilters,theMagicLung®blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmoreefficientlythanotherthanotherfiltrationsystems.WhencomparingtheMagicLung®withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.

# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1210A

OPTIONAL DUCT

COVER

OPTIONAL DUCT

COVER

OPTIONAL DUCT

COVER

EP(X)T18/EP(X)TH18/NEP(X)T18/NEP(X)TH18/SEP(X)T18/SEP(X)TH18 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover sold separately). Optional duct covers available in standard and custom sizes.

Connection Diagram (54” - 66” Widths)

EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS

*Exceeding recommended mounting height may

compromise performance.

CenterlineOf Hood

Wall Side

Electrical (2)

10" OutletCentered On

Hood Top

12 �⁄�” 9 �⁄�”

1 ¾”

Wall Side

7"Electrical (2)

CenterlineOf Hood

12" OutletCentered OnTop Of Hood

1 ¾”

16 ½” 5 ½”1 ¾”

18"

10"

8 ½”

18"

12"

7 ½"

ULC USR

(X) in part number indicates 27” depth

NEP(X)T18/NEP(X)TH18EP(X)T18/EP(X)TH18 SEP(X)T18/SEP(X)TH18

The transition shown (VP562 & VP563) is installed in the hood

at the factory as a standard item. It will be located in the

exact center of the duct cover (left to right & front to rear).

Duct Cover(Top of Hood)

10" Dia. or 12" Dia.Transition Location

"Centered"

Connection Diagram (42" - 66" Widths) RecommendedMounting Height

900 CFM B200 Dual & B100 Single Blower(Top View)

VP562 Standard TransitionInstalled (Front View)

1200 CFM Double B200 Dual Blowers(Top View)

VP563 Standard TransitionInstalled (Front View)

Electrical/Mechanical Specifications For Blower Units

Model Volts Amps* Hz RPM [email protected]" Equivalent CFM• CFM

[email protected]"CFM

[email protected]"CFM

[email protected]"Minimum Round

Duct Size Sones#

B200 Dual & B100 Single 115 4.4 60 1550 900 1350 804 725 655 10" (79 in.2) 6.3Two B200 Duals 115 5.8 60 1550 1200 1800 1062 960 860 12" (113 in.2) 6.6

* Add0.5ampforeachhalogenlight.Hoodisavailablewithfluorescentlights(oneforeachsingleordualblower)orwithhalogenlights(3lights:42"-53",4lights:54"-66").• BecausetheMagicLung®blowerusescentrifugalfiltrationratherthanconventionalbaffleormeshfilters,theMagicLung®blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmoreefficientlythanotherthanotherfiltrationsystems.WhencomparingtheMagicLung®withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.

# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1210A

OPTIONAL DUCT