Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1...

8
Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1 Panorama Nova RP

Transcript of Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1...

Page 1: Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1 Panorama Nova RP.

Full Face Masks w/Plug-In Connector

Instructions for Use

March 26 2009 O2 TNG, MRT Trainee - POM1

Panorama Nova RP

Page 2: Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1 Panorama Nova RP.

What’s What1. Face piece

Connector2. Clip3. Inner Mask4. Visor5. Clamping Frame6. Front Strap7. Head Straps8. Soft body9. Face blank10. ButtonMarch 26 2009 O2 TNG, MRT Trainee - POM2

Page 3: Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1 Panorama Nova RP.

UseFor masks with visor

wiper: Soak the wiper with the de-misting agent. It must not be actuated when dry.

Hold the full face mask ready: Undo the straps as far as possible.

Put on the PSS BG 4 Closed-Circuit Breathing Apparatus, and press the plug-in connector until it engages

March 26 2009 O2 TNG, MRT Trainee - POM3

Page 4: Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1 Panorama Nova RP.

Use Put on the mask: Unbutton the strap and

place chin in recess. Fit straps round the

head and pull them back until the front strap rests smoothly on the face.

Position the Mask

1. Tighten the neck straps uniformly

2. Tighten the temple straps uniformly

3. Tighten the front strap if head is fairly small.

March 26 2009 O2 TNG, MRT Trainee - POM4

Page 5: Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1 Panorama Nova RP.

Check for LeaksTightly compress both

breathing hoses and breathe in until vacuum is produced.

Briefly hold your breath: the vacuum must be maintained.

If it is not, the straps must be tightened further.

The leak test must be repeated twice.

The mask may only be used if perfectly tight!

March 26 2009 O2 TNG, MRT Trainee - POM5

Page 6: Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1 Panorama Nova RP.

WiperIf the visor mists over, it can be cleared by

wiping. The wiper is activated via a lever on the outside of the visor.

The wiper must then be returned to its basic position in the middle of the visor.

March 26 2009 O2 TNG, MRT Trainee - POM6

Page 7: Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1 Panorama Nova RP.

After use Disconnect the PSS BG

4 closed circuit breathing apparatus: press the button and simultaneously draw the plug-in connector out of the face piece connector

Remove mask: Slide your index finger under the ends of the neck straps, press the clamps forwards with your thumbs and evenly pull the mask over your head and off your face.

March 26 2009 O2 TNG, MRT Trainee - POM7

Page 8: Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1 Panorama Nova RP.

Cleaning and DisinfectingCleaning: The mask must be cleaned whenever it

has been used. Position the wiper in the middle of the visor.

The mask must be thoroughly rinsed in lukewarm water containing a little all-purpose Sekusept Cleaner and a cloth.

Rinse under running water.Disinfection: The mask must be disinfected

whenever it has been used. Only use approved disinfectants.

Rinse under running water.Drying: Leave mask to dry in drying cabinet or in air.

March 26 2009 O2 TNG, MRT Trainee - POM8