FUA (60Hz) - Clean Air Co

13
www.plymovent.com product data sheet APPLICATIONS The FUA fans are intended to be used for the following applications: • MIG-MAG/GMAW welding • TIG welding • FCAW welding • stick/MMAW welding • vehicle exhaust extraction systems SPECIFICATIONS Physical dimensions and properties Material: • fan • housing • aluminium • sheet metal Color of housing grey (RAL 7035) Motor design NEMA Fan type centrifugal Impeller backward inclined Design conditions 68°F (20°C) at sea level Max. airflow temperature 176°F (80°C) continuously Performance Max. starts/stops per hour 30 Ambient conditions Operating temperature: • min. • nom. • max. • -4°F (-20°C) • 68°F (20°C) • 104°F (40°C) Max. relative humidity 80% Storage conditions • -4 to 104°F (-20 to 40°C) • relative humidity max. 80% Options and accessories Universal mounting bracket for freestanding, wall, or ceiling mounting • MB-FUA/S1 • FUA-1800/2100/2700 • MB-FUA/S2 • FUA-3000/4700 Mounting bracket to mount the fan on a FlexMax extension crane, UK extractor crane or FEB boom arm • MB-FUA/C1 • FUA-1800/2100/2700 • MB-FUA/C2 • FUA-3000/4700 Outlet transition from rectangular to round • OL-250/FUA-3000 • FUA-3000 • OL-250/FUA-4700 • FUA-4700 • OL-315/FUA-4700 • FUA-4700 Soft connection • SC-160 • FUA-1800/2100/2700 • SC-250 • FUA-3000/4700 (+OL-250) Scope of supply Extraction fan Shipping data Harmonized Tariff Code 8414.5940.90 Number/package 1 APPROVALS/CERTIFICATES FUA-1800/2100/2700: compliance with CE directives FUA-3000/4700: compliance with CE directives as part of an installation Directive 2011/65/EC (RoHS2) valid as of 8 June 2011 Plymovent certifies that the products shown herein are licensed to bear the AMCA Seal. The ratings shown comply with the requirements of the AMCA Certified Ratings Program. Certified motor Certified motor FUA-1800/2100/2700/3000/4700 The FUA is an extraction fan that is specially designed to remove exhaust gases, as well as welding and other fumes, dust and oil mist. The fan is intended and designed for mounting to extraction arms, filter units and vehicle exhaust extraction systems or can be used as a central fan. FUA (60Hz) Page 1/9

Transcript of FUA (60Hz) - Clean Air Co

www.plymovent.com

pro

du

ct d

ata

shee

t

APPLICATIONS

The FUA fans are intended to be used for the following applications: • MIG-MAG/GMAW welding• TIG welding• FCAW welding• stick/MMAW welding• vehicle exhaust extraction systems

SPECIFICATIONS

� Physical dimensions and propertiesMaterial:• fan• housing

• aluminium• sheet metal

Color of housing grey (RAL 7035)Motor design NEMAFan type centrifugalImpeller backward inclinedDesign conditions 68°F (20°C) at sea levelMax. airflow temperature 176°F (80°C) continuously

� PerformanceMax. starts/stops per hour

30

� Ambient conditionsOperating temperature:• min.• nom.• max.

• -4°F (-20°C)• 68°F (20°C)• 104°F (40°C)

Max. relative humidity 80%Storage conditions • -4 to 104°F (-20 to 40°C)

• relative humidity max. 80% � Options and accessories

Universal mounting bracket for freestanding, wall, or ceiling mounting• MB-FUA/S1 • FUA-1800/2100/2700• MB-FUA/S2 • FUA-3000/4700Mounting bracket to mount the fan on a FlexMax extension crane, UK extractor crane or FEB boom arm• MB-FUA/C1 • FUA-1800/2100/2700• MB-FUA/C2 • FUA-3000/4700

Outlet transition from rectangular to round• OL-250/FUA-3000 • FUA-3000• OL-250/FUA-4700 • FUA-4700• OL-315/FUA-4700 • FUA-4700Soft connection• SC-160 • FUA-1800/2100/2700• SC-250 • FUA-3000/4700 (+OL-250)

� Scope of supplyExtraction fan

� Shipping dataHarmonized Tariff Code 8414.5940.90Number/package 1

APPROVALS/CERTIFICATESFUA-1800/2100/2700:compliance with CE directivesFUA-3000/4700:compliance with CE directives as part of an installationDirective 2011/65/EC (RoHS2) valid as of 8 June 2011

Plymovent certifies that the products shown herein are licensed to bear the AMCA Seal. The ratings shown comply with the requirements of the AMCA Certified Ratings Program.

Certified motor

Certified motor

FUA-1800/2100/2700/3000/4700The FUA is an extraction fan that is specially designed to remove exhaust gases, as well as welding and other fumes, dust and oil mist.

The fan is intended and designed for mounting to extraction arms, filter units and vehicle exhaust extraction systems or can be used as a central fan.

FUA (60Hz)

Page 1/9

ARTICLE NUMBERS, WEIGHTS AND PACKING DIMENSIONS

Fan type Connection voltage Article numberWeight

Packing dimensionsNet Gross*)

FUA-1800 115/208-230V/1ph/60Hz 0000102912 66.1 lbs 72.8 lbs 22.4 x 22.0 x 16.5 in.208-230/460V/3ph/60Hz 0000102913 51.8 lbs 56.2 lbs 18.5 x 18.5 x 20.9 in.575V/3ph/60Hz 0000102914 51.8 lbs 56.2 lbs 18.5 x 18.5 x 20.9 in.

FUA-2100 115/208-230V/1ph/60Hz 0000102916 67.7 lbs 68.3 lbs 22.4 x 22.0 x 16.5 in.208-230/460V/3ph/60Hz 0000102917 54.0 lbs 58.4 lbs 18.5 x 18.5 x 20.9 in.575V/3ph/60Hz 0000102918 54.0 lbs 58.4 lbs 18.5 x 18.5 x 20.9 in.

FUA-2700 115/208-230V/1ph/60Hz 0000102919 68.3 lbs 76.1 lbs 22.4 x 22.0 x 16.5 in.208-230/460V/3ph/60Hz 0000102920 60.6 lbs 65.0 lbs 18.5 x 18.5 x 20.9 in.575V/3ph/60Hz 0000102921 60.6 lbs 65.0 lbs 18.5 x 18.5 x 20.9 in.

FUA-3000 115/208-230V/1ph/60Hz 0000102922 87.1 lbs 93.7 lbs 23.2 x 23.6 x 23.6 in.208-230/460V/3ph/60Hz 0000102923 72.8 lbs 80.5 lbs 23.6 x 23.6 x 19.3 in.575V/3ph/60Hz 0000103156 72.8 lbs 80.5 lbs 23.6 x 23.6 x 19.3 in.

FUA-4700 115/208-230V/1ph/60Hz 0000102924 90.4 lbs 99.2 lbs 31.1 x 23.2 x 25.6 in.208-230/460V/3ph/60Hz 0000102925 90.4 lbs 99.2 lbs 31.1 x 23.2 x 25.6 in.

575V/3ph/60Hz 0000102926 90.4 lbs 99.2 lbs 31.1 x 23.2 x 25.6 in.

*) Gross weight = including packaging

Remaining specifications: refer to next pages.

Product type FUA (60Hz)

Article no. refer to tables

Product category extraction fans

Version 061119/F

Always check the latest version on www.plymovent.comPage 2/9

Application restrictionsDo not use the product for the following applications or in the following circumstances: aluminium laser cutting | extraction of aggressive fumes and gases (e.g. from acids, alkaline or soldering paste containing lithium) | extraction of hot gases (more than 176°F (80°C) continuously) | grinding aluminium and magnesium | flame spraying | extraction of cement, saw dust, wood dust, etc. | explosive environments or explosive substances/gases

DIMENSIONS

FUA-1800/2100/2700 FUA-3000/4700

B

C

H

G

G

I

F

E

DD

F

H

I

E

B

A

G

C

FUA-1800 FUA-2100 FUA-2700 FUA-3000 FUA-4700

mm inch mm inch mm inch mm inch mm inch

A - - - - - - 275 10.8 348 13.7

B Ø 159 Ø 6.3 Ø 159 Ø 6.3 Ø 159 Ø 6.3 205 8.1 205 8.1

C 125 4.9 125 4.9 125 4.9 145 5.7 145 5.7

D 1~ motor 403 15.9 430 16.9 430 16.9 489 19.3 508 20.0

3~ motor 375 14.8 375 14.8 400 15.8 459 18.1 478 18.8

E 455 17.9 455 17.9 455 17.9 512 20.2 591 23.3

F 244 9.6 244 9.6 244 9.6 228 9.0 258 10.2

G Ø 160 Ø 6.3 Ø 160 Ø 6.3 Ø 160 Ø 6.3 Ø 250 Ø 9.8 Ø 245 Ø 9.6

H 433 17.1 433 17.1 433 17.1 583 23.0 733 28.9

I 201 7.9 201 7.9 201 7.9 247 9.7 297 11.7

POSSIBLE OUTLET POSITIONS

FUA-1300/1800/ 2100/2700/3000 FUA-4700

S6

S6

60° or multiple 90° 45° or multiplePage 3/9

PRESSURE DROP FUA-1800 | FUA-2100

FUA-1800

FUA-2100

Page 4/9

PRESSURE DROP FUA-2700 | FUA-3000

FUA-2700

FUA-3000

Page 5/9

PRESSURE DROP FUA-4700

FUA-4700

Page 6/9

Sub table A: Sound power levels (Lw) in dB

Sound power is a measure of sound energy per time unit. For a sound source, unlike sound pressure, sound power is neither room dependent nor distance dependent. Sound power is a theoretical value that is not measurable. It is calculated and expressed in watts and as sound power level LW in decibels.

The table below shows the sound power levels in dB calculated according to AMCA Standard 301.

Static pressure (in. WG)

Airflow (CFM)

Octave band number & center frequency number (Hz)1 2 3 4 5 6 7 8

63 125 250 500 1000 2000 4000 8000

FUA

-18

00 0 836 109 100 91 91 87 86 82 76

2.4 715 105 98 89 88 83 83 78 714.8 530 100 99 87 86 81 80 74 687.15 331 104 97 81 82 79 76 70 65

FUA

-21

00 0 1115 97 98 91 93 88 88 83 80

2.5 890 90 95 91 93 86 84 79 755 660 95 96 89 90 84 81 75 71

7.62 447 88 94 89 89 83 79 72 70

FUA

-27

00 0 1107 78 88 90 89 86 84 83 80

2.95 900 79 87 89 87 85 81 79 745.35 700 83 84 88 84 83 79 76 717.75 500 80 82 88 87 85 79 74 70

FUA

-30

00 0 1818 89 91 97 99 94 90 84 81

2.2 1570 95 91 98 100 91 87 81 784.4 1320 88 90 98 96 88 84 78 756.66 977 89 91 95 94 86 82 75 72

FUA

-47

00 0 2614 99 93 92 93 92 91 87 86

2.4 2343 98 95 94 93 92 90 85 835 2040 98 95 93 92 89 87 82 80

8.05 1528 95 92 96 91 86 85 80 77

Sub table B: Conversion of sound power level (Lw) to sound pressure level (Lp)

A sound source produces sound power, which generates a sound pressure fluctuation in the air. Sound power is the distance- independent cause of this, whereas sound pressure is the distance-dependent effect.

The table below shows the dB value to be deduced from the values of sub table A to the achieve the sound pressure level at a certain distance.

Sound pressure levelAt a distance of: 1 m (3.3 ft) 2 m (6.5 ft) 3 m (9.8 ft) 4 m (13.1 ft)Ref.: sound power levels (Lw) in sub table A ‒11 dB ‒17 dB ‒21 dB ‒23 dB

Sub table C: A-weighting of sound pressure level

The most common weighting that is used in noise measurement is A-weighting. Like the human ear, this effectively cuts off the lower and higher frequencies that the average person cannot hear.

The table below shows the A-weighting related to the different frequencies.

Octave band number 1 2 3 4 5 6 7 8Frequency (Hz) 63 125 250 500 1000 2000 4000 8000A-weighing ‒0.8 ‒0.2 0 0 0 ‒0.2 ‒0.8 ‒3.0

Note: dB(A) levels are not licensed by AMCA International.

Page 7/9

NOISE LEVEL

MOTOR SPECIFICATIONS FUA-1800 | FUA-2100 | FUA-2700

FUA-1800 FUA-2100 FUA-2700

Power 0.75 Hp0.55 kW

1 Hp0.75 kW

1 Hp0.75 kW

1.5 Hp1.1 kW

Energy efficiency (NEMA)

standard standard premium premium

Rated voltage 115/208-230V

208-230/ 460V

575V 115/208-230V

208-230/ 460V

575V 115/208-230V

208-230/ 460V

575V

No. of phases 1ph 3ph 3ph 1ph 3ph 3ph 1ph 3ph 3ph

Frequency 60Hz 60Hz 60Hz 60Hz 60Hz 60Hz 60Hz 60Hz 60Hz

Frame 56C 56C 56C 56C 56C 56C 56C 56C 56C

Poles 2 2 2 2 2 2 2 2 2

Rated speed 3450 rpm 3450 rpm 3475 rpm 3450 rpm 3480 rpm 3480 rpm 3450 rpm 3490 rpm 3460 rpm

Slip Unlisted Unlisted 3.47% Not Listed Not Listed 3.47% Unlisted Unlisted 3.89%

Rated current 10/5.2-5 A 2.5-2.4/1.2 A 0.904 A 12.0/6.2-6.0 A 5.2-4.8/2.4 A 1.15 A 17/8.7-8.5 A 4.4-4.2/2 A 1.62 A

L. R. Amperes 30 A 7.3A @460 V 6.33 A 64.40 A 26.00 A @460 V

13.1 A 133/66.8 A 34.0/17.0 A 13.6 A

ll/ln Unlisted Unlisted Unlisted Not Listed Not Listed Not Listed Unlisted Unlisted Unlisted

No load current 2.93 A @230 V

0.75 A @460 V

0.440 A 4.5 A @ 230 V 0.95 A @460 V

0.829 A 4.67 A @230 V

1.00 A @ 460 V

0.652 A

Rated torque 18.00 ft-lbs (24-40 Nm)

18.00 ft-lbs (24-40 Nm)

1.12 ft-lbs (1.51 Nm)

3.00 ft-lbs (4.07 Nm)

3.02 ft-lbs (4.09 Nm)

1.49 ft-lbs (2.02 Nm)

2.25 ft-lbs (3.05 Nm)

2.25 ft-lb (3.05 Nm)

2.25 ft-lb (3.05 Nm)

Locked rotor torque

356% 256% 250% 250% 360% 229% 240% 378% 240%

Breakdown torque 267% 361% 290% 260% 433% 380% 270% 498% 270%

Design N B N L A B B

Insulation class N B F B F F L F F

Temperature rise 57 @100% load

80 K 90 @100% load

46 @100% load

80 @100% Load

46.0 @100%

80 K

Locked rotor time Unlisted 22 s (hot) 23 s (hot) 90.0 F @FL 17 s (hot) 11 s (hot) Unlisted Unlisted 21 s (hot)

Service factor 1.15 1.15 1.15 1.15 1.15 1.15 1 1.15 1.15

Duty cycle Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous

Ambient temperature

-20°C to +40°C (-4°F to 104°F)

-20°C to +40°C (-4°F to 104°F)

-20°C to +40°C (-4°F to 104°F)

-4°F to 104°F (-20°C to +40°C)

-4°F to 104°F (-20°C to +40°C)

-4°F to 104°F (-20°C to +40°C)

-20°C to +40°C (-4°F to 104°F)

-20°C to +40°C (-4°F to 104°F)

-20°C to +40°C (-4°F to 104°F)

Altitude 1000 m (3280 ft) above sea level

1000 m (3280 ft) above sea level

1000 m (3280 ft) above sea level

1000 m (3280 ft) above sea level

1000 m (3280 ft) above sea level

1000 m (3280 ft) above sea level

1000 m (3280 ft) above sea level

1000 m (3280 ft) above sea level

1000 m (3280 ft) above sea level

Enclosure IP43 (TEFC) IP54 (TEFC) IP55 (TEFC)

IP43 (TEFC) IP43 (TEFC) IP55 (TEFC) IP43 (TEFC) IP43 (TEFC) IP55 (TEFC)

Mounting Rigid/R1 Rigid/R1 Rigid/R1 Rigid/F1 Rigid/F1 Rigid/F1 Rigid/R1 Rigid/R1 B34T

Rotation both both both both both both both both both

Preferred preset rotation direction

CCW, seen from drive end side

CCW, seen from drive end side

CCW, seen from drive end side

Approx. weight 29 lbs (13.15 kg)

22.00 lbs (9.98 kg)

20.90 lbs (9.48 kg)

45 lb (20,41 kg)

35 lb (15,88 kg)

32.3 lb (14,65 kg)

37 lbs (16.78 kg)

32 lbs (14.52 kg)

27.10 lbs (12.29 kg)

Moment of inertia 0.0020 kgm² 0.0014 kgm² 0.0014 kgm²

Not Listed Not Listed 0.0963 sq.ft.lb (0.0133 kgm²)

0.0023 kgm² 0.0020 kgm²

0.0020 kgm²

Sound pressure level (global)

Unlisted Unlisted 68.0 dB(A) Not Listed Not Listed 68.0 dB(A) Unlisted Unlisted 68.0 dB(A)

Foundation loads:• max. traction• max. compression

Unlisted Unlisted Unlisted Unlisted Unlisted Unlisted Unlisted Unlisted250 N431 N

Load: 100%• Power factor• Efficiency

76.3%64%

75.6%78.4 %

85%72%

87.0%73%

87.1%88.4%

90.0%80.0%

80%72%

82.2%84.6%

90%77%

Load: 75%• Power factor• Efficiency

73%58.6%

70.6%73.5%

79%68%

81.7%72.9%

86.7 %82.1%

86%78.5%

73.5%70.5%

76.3%82.2%

0.8284.0%

Load: 50%• Power factor• Efficiency

65.4%50.3%

58.9%68.3%

70%62%

71.8%71%

85.5%72.2%

76%75.5%

66.1%62.7%

64.7%79.1%

76%72%

Page 8/9

MOTOR SPECIFICATIONS FUA-3000 | FUA-4700

FUA-3000 FUA-4700

Power 2 Hp1.5 kW

3 Hp2.2 kW

Energy efficiency (NEMA)

standard premium

Rated voltage 115/208-230V

208-230/ 460V

575V 208-230V 208-230/ 460V

575V

No. of phases 1ph 3ph 3ph 1ph 3ph 3ph

Frequency 60Hz 60Hz 60Hz 60Hz 60Hz 60Hz

Frame 56C 56C 56C 145T 56C 56C

Poles 2 2 2 2 2 2

Rated speed 3450 rpm 3490 rpm 3600 rpm 3450 rpm 3490 rpm 3480 rpm

Slip Unlisted Unlisted 3.06% 2.78% 3.89% 3.33%

Rated current 20/11.4-10 A

5.2-4.8/2.4 A

3.10 A 14.38-13 A 8.8-8/4 A 3.01 A

L. R. Amperes 64.40 A 34.0/17.0 A 16.1 A 100 A @230V

41 A @460V

25.6 A

ll/ln 9.4Code M

8.9Code L

8.9Code L

7.0Code J

8.1Code J

8.1Code J

No load current 8.00/4.00 A 1.50/0.750 A

0.600 A 5.30/2.65 A 3.08/1.54 A 1.12 A

Rated torque 3.02 Nm 3.06 Nm 3.06 Nm 6.10 Nm 6.17 Nm 6.17 Nm

Locked rotor torque

250% 350% 350% 210% 330% 330%

Breakdown torque 310% 380% 380% 230% 360% 360%

Design L B B B B

Insulation class F F F F F F

Temperature rise 80 K 80 K 80 K 80 K

Locked rotor time 8 s (hot) 21 s (hot) 21 s (hot) 8 s (hot) 14 s (hot) 14 s (hot)

Service factor 1.15 1.15 1.25 1.15 1.25 1.25

Duty cycle S1 S1 S1 S1 S1 S1

Ambient temperature

-20°C to +40°C (-4°F to 104°F)

-20°C to +40°C (-4°F to 104°F)

-20°C to +40°C (-4°F to 104°F)

-20°C to +40°C (-4°F to 104°F)

-20°C to +40°C (-4°F to 104°F)

-20°C to +40°C (-4°F to 104°F)

Altitude 1000 m (3280 ft) above sea level

1000 m (3280 ft) above sea level

1000 m (3280 ft) above sea level

1000 m (3280 ft) above sea level

1000 m (3280 ft) above sea level

1000 m (3280 ft) above sea level

Enclosure IP55 (TEFC) IP55 (TEFC) IP55 (TEFC) IP55 (TEFC) IP55 (TEFC) IP55 (TEFC)

Mounting B34T B34T B34T B34T B34T B34T

Rotation both both both both both both

Preferred preset rotation direction

CCW, seen from drive end side

CCW, seen from drive end side

Approx. weight 26.0 kg (57.3 lbs)

18.5 kg(40.8 lbs)

18.5 kg(40.8 lbs)

27.9 kg (61.5 lbs)

23.5 kg (51.8 lbs)

23.5 kg (51.8 lbs)

Moment of inertia 0.0023 kgm²

0.0020 kgm²

0.0020 kgm²

0.0028 kgm²

0.0026 kgm²

0.0026 kgm²

Sound pressure level (global)

68.0 dB(A) 68.0 dB(A) 68.0 dB(A) 68.0 dB(A)

Foundation loads:• max. traction• max.

compression

250 N431 N

250 N431 N

274 N548 N

55 kgf78 kgf

536 N766 N

Load: 100%• Power factor• Efficiency

0.8876.4%

0.8685.5%

0.8684.0%

0.9079.0%

0.8686.5%

0.8686.5%

Load: 75%• Power factor• Efficiency

0.8675.5%

0.8284.0%

0.8284.0%

0.8778.5%

0.8186.5%

0.8186.5%

Load: 50%• Power factor• Efficiency

0.8374.3%

0.7281.5%

0.7281.5%

0.7975.0%

0.7085.5%

0.7085.5%

Page 9/9

www.plymovent.com

ApplicAtions

The TEV is intended to be used for the followingapplications:•MIG-MAG/GMAW welding•TIG welding•FCAW welding•stick/MMAW welding•vehicle exhaust extraction systemsDo not use the TEV for the following applicationsor in the following circumstances:•aluminium laser cutting•extraction of aggressive fumes and gases (e.g.

from acids, alkaline, or soldering paste containing lithium)

•extraction of hot gases (more than 80°C/176°F continuously)

•grinding aluminium and magnesium•flamespraying•extraction of cement, saw dust, wood dust, etc.•explosive environments or explosive substances/gases

specificAtions

� physical dimensions and propertiesMaterial:•fan•housing

aluminiumsheet metal

Colour:•motor•housing

black (RAL 9005)grey (RAL 7035)

Motor design IEC 60072Discharge position rotatable 90°Fan type radialDesign conditions 20°C (68°F) at sea levelMax.airflowtemperature 80°C (176°F)

� performance

Speed 2800 rpm � electrical data

Max. start/stops per hour 30Insulation class FProtection class IP 55

� Ambient conditionsOperating temperature:•min.•nom.•max.

5°C (41°F)20°C (68°F)40°C (104°F)

Max. relative humidity 80%Outdoor use allowed yes - protection against

precipitation is recommended and obligatory in costal areas

Storage conditions 5-40°C (41-104°F)relative humidity max. 80%

� product combinationsVehicle exhaust extraction systems

all systems

Filter units all systemsFume extraction systems all systemsControl equipment all systems

� scope of supplyExtraction fan

� order informationNumber/package 1

� shipping dataHarmonized Tariff Code 8414.5940.90Country of origin the Netherlands

See table 1: for dimensions.Seetable2: forremainingspecifications,options and accessories.See page 4: for fan curves.

ApprovAls/certificAtes

Directive 2011/65/EC (RoHS) valid as of 8 June 2011

tev-385/585/765/985TEV (the energy saving ventilator) is an extraction fan that is designed to remove welding fumes and other harmful fumes such as dust, oil mist and vehicle exhaust gases.

The TEV fan is intended and designed for mounting to a central extraction system.

tev rAnge

Page 1/4

pro

du

ct d

ata

shee

t

E

F

G

H I

JK

A

B

D

C

E

F

G

H I

JK

A

B

D

C

Page 2/4

Product type tev range

Article no. see order information

Product category extraction fan

Version 290113/D

Always check the latest version on www.plymovent.com.

Table 1: Dimensions

tev-385 tev-585 tev-765 tev-985

mm inch mm inch mm inch mm inch

A 640 25.2 783 30.8 980 38.6 1100 43.3

B 285 11.2 339 13.4 377 14.8 479 18.9

C 640 25.2 783 30.8 980 38.6 1100 43.3

D 267 10.5 310 12.2 402 15.8 447 17.6

E 446 17.6 532 20.9 606 23.9 673 26.5

F 230 9.1 270 10.6 290 11.4 320 12.6

G 312 12.3 380 15.0 460 18.1 508 20.0

H Ø 162 Ø 6.4 Ø 200 Ø 7.9 Ø 252 Ø 9.9 Ø 317 Ø 12.5

I 477 18.8 602 23.7 741 29.2 829 32.6

J 160 6.3 200 7.9 220 8.7 250 9.8

K 204 8.1 244 9.6 264 10.4 294 11.6

Fan wheel (not shown) - diameter - width

Ø 31585

Ø 12.43.4

Ø 40085

Ø 15.83.4

Ø 50065

Ø 19.72.6

Ø 56085

Ø 22.13.4

Page 3/4

Table2:Remainingspecifications,optionsandaccessoriesfeatures tev-385 tev-585 tev-765 tev-985

Article number 0000100324 0000100325 0000100326 0000100327

� Weight

Net weight 32 kg (71 lbs) 51 kg (112 lbs) 71 kg (157 lbs) 81 kg (179 lbs)

� electrical data

Connection voltage 230-400V/3~/50Hz 230-400V/3~/50Hz 230-400V/3~/50Hz 400-690V/3~/50Hz

Power 0,75 kW (1 HP) 2,2 kW (3 HP) 4 kW (5 HP) 7,5 kW (10 HP)

Nominal current - 230V - 400V - 690V

3,02 A1,7 A-

7,98 A4,61 A-

13,32 A7,69 A-

-14,1 A8,2 A

� performance

Noise level dB(A) 80 86 87 96

� options and accessories

Fan on/off manually (wall)Motor starter: - motor protection switch 230V/3~/50Hz

- motor protection switch 400V/3~/50Hz

- motor protection switch 400-690V/3~/50Hz

MPS-2.5-4.0 A

MPS-1.6-2.5 A

-

MPS-6.3-10.0 A

MPS-4.0-6.3 A

-

MPS-10.0-16.0 A

MPS-6.3-10.0 A

-

-

MPS-10.0-16.0 A

MPS-6.3-10.0 A

Fan on/off manually (hood of extraction arm) - starter for fan and working light - thermal relay 230V/3~/50Hz - thermal relay 400V/3~/50Hz

SA-24-75MS-2.3/3.2MS-1.4/2.0

SA-24-75MS-7.2/10MS-4.5/6.3

SA-24-75-MS-7.2/10

-

Fan on/off automatically (inductive sensor) - starter for fan and working light - thermal relay 230V/3~/50Hz - thermal relay 400V/3~/50Hz

ES-90-005MS-2.3/3.2MS-1.4/2.0

ES-90-005MS-7.2/10MS-4.5/6.3

ES-90-005-MS-7.2/10

-

Fan on/off automatically(light sensor) - starter for fan and working light - light sensor - thermal relay 230V/3~/50Hz - thermal relay 400V/3~/50Hz

ES-90-005 LS-12MS-2.3/3.2MS-1.4/2.0

ES-90-005LS-12MS-7.2/10MS-4.5/6.3

ES-90-005LS-12 -MS-7.2/10

-

Outlet transition from rectangular to round

TOL-250 TOL-315 TOL-400 TOL-500

Soft connection for noise and vibration free connection to duct - inlet - outlet

SC-160SC-250

SC-200SC-315

SC-250SC-400

SC-315SC-500

Vibration dampers to isolate noise and vibration in sensitive environments.

TEV-AV/35 TEV-AV/35 TEV-AV/79 TEV-AV/79

� shipping data

Gross weight 41 kg (90 lbs) 60 kg (132 lbs) 95 kg (209 lbs) 105 kg (231 lbs)

Packing dimensions 860 x 750 x 630 mm(34 x 30 x 25 in.)

860 x 750 x 825 mm(34 x 30 x 33 in.)

1200 x 800 x 1150 mm(47 x 32 x 45 in.)

1200 x 800 x 1150 mm(47 x 32 x 45 in.)

Page 4/4

fAn curves

0

500

1000

1500

2000

2500

3000

3500

4000

4500

0 2000 4000 6000 8000 10000 12000 14000

TEV-385

A

B

TEV-985TEV-765TEV-585