FU Tiller - Raytheon Anschütz · FU Tiller Type 105-105 NG020, NG021, NG022 1 Description 2...
Transcript of FU Tiller - Raytheon Anschütz · FU Tiller Type 105-105 NG020, NG021, NG022 1 Description 2...
Raytheon Anschütz GmbHPostfach 1166D -- 24100 KielGermanyTel +49--4 31--30 19--0Fax +49--4 31--30 19--501Email [email protected]
3699/105-105.DOC010002 Edition: August 12, 2003Revision: March 25, 2004Revision: Dec. 05, 2007
FU Tiller
Type 105-105 NG020, NG021, NG022
1 Description2 Technical Data3 First Putting into Operation
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung undMitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrücklichzugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz.
Copying of this document, and giving it to others and the use orcommunication of the contents thereof, are forbidden without expressauthority. Offenders are liable to the payment of damages.
Toute communication ou reproduction de ce document, touteexploitation ou communication de son contenu sont interdites, saufautorisation expresse. Tout manquement à cette règle est illicite etexpose son auteur au versement de dommages et intérêts.
Sin nuestra expresa autorización, queda terminantemente prohibida lareproducción total o parcial de este documento, así como su usoindebido y/o su exhibición o comunicación a terceros. De los infractoresse exigirá el correspondiente resarcimiento de daños y perjuicios.
FU TILLER
TechnicalDocumentation
IEdition: Dec. 05, 2007 3699/105--105.DOC010002
CONTENTS Page
1 Description 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Technical Data 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Override switch 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 First Putting into Operation 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Annex:
Spare parts cataloguesDimensional Drawing 105--105.HP005Circuit diagram 105--105.HP037Circuit diagram 105--105.HP039 (sheets 1 and 2)Wiring diagram 105--105.HP044
This equipment includes electromechanical devicessuch as relays, switches or potentiometers.Electromechanical devices are subject to wear andtear depending on operation cycles and environmentalconditions.
Caution!Use only original RAYTHEON Anschütz spare parts
FU TILLER
II Edition: March 25, 20043699/105--105.DOC010002
Intentionally left blank
FU TILLER TechnicalDocumentation
1 3699/105--105.DOC010002Edition: March 25, 2004
1 Description
The tiller -- set into control desks or stearing stands -- serves as follow--up steering ele-
ment on bridges (FOLLOW UP).The standard scale division is ±35°, the deflection angle of the knob is ±60°. In the me-chanical zero position the knob is slightly engaged. The scale is illuminated; the bright-ness is regulated automatically.When the follow--up (FU) steering control is selected via the steering mode selectorswitch, the illumination of the scale is switched on.Depending on the application, single--, twin-- or fourfold potentiometers are used.Optionally, a handle can be attached to the knob for use as a lever.For a rudder angle change to starboard (STBD) the knob must be turned clockwise; if alever is used, this must be turned toward STDB.The steering control effect corresponds to that of a handwheel.There is an override switch integrated in this tiller, it is switched by turning the tiller morethan 1°. By this the autopilot mode is interrupted and the steering control is performedvia this tiller.
Option
FU TILLER
23699/105--105.DOC010002 Edition: March 25, 2004
2 Technical Data
Recess and drilling scheme
Dimensions:
M4 (4x)
L* : Type A: L = 80 (3.15)Type B and C: L = 120 (4.75)
A NG 020B NG 021C NG 022
Typ
overrideswitch
Weight: approx. 1 kgScale range, standard: ±35°
other scales: ±45°, ±60°, ±90°Supply voltage: 24 VDCSteering potentiometer: 20 kΩNumber of potentiometers, Type A: 1
Type B: 2Type C: 4
max. wire cross section: 1.5 mm2
Type of enclosure: IP 23 EN 60529 after installationAmbient temperature (operation): --25 °C to +55 °C
Zero adjustment, setting of the slope and the symmetry via subordinate trim potentiome-ter.
FU TILLER TechnicalDocumentation
3 3699/105--105.DOC010002Edition: March 25, 2004
3 Override switchfor location see below mentioned drawing,for connection see below mentioned drawing and connection diagram 105--105.HP044.
OverrideSwitch
TerminalBoardOverrideSwitch
FU TILLER
43699/105--105.DOC010002 Edition: August 12th, 2003
4 First Putting into Operation
1 2 3 4 5 6 7 8
+24V
DC
0V U+
M U--
1 2 3 4 5 6 7 8
+24V
DC
0VU+
M U--
9 10 11 12 13 14 15 16 17 18 19 20
U+
M U--
U+
M U--
U+
M U--
Connection for Type A:
Connection forType B or Type C:
L1
L1
Adjustment:Brightness of background:Adjust brightness of background with potentiometer R2; be sure to adjust during nightoperation (when the bridge is dark)!
Offset / Zero:Set tiller to 0°; move zero--potentiometer until 0° is shown on the rudder position indi-cator as well.
Gain:Set tiller to 20° (PORT or STBD); move gain--potentiometer until 20° (PORT or STBD)is also shown on the rudder position indicator.Symmetry:Adjust tiller to max PORT (for example: 35°) and after that to max. STBD.If there is a difference between both rudder position indicators, then adlust the diffe-rence with the potentiometer “SYM”.Check ZERO and GAIN adjustments again.If necessary repeat the a.m. procedure in total.
FU TILLER TechnicalDocumentation
5 3699/105--105.DOC010002Edition: March 25, 2004
see appended drawings: 105--105 HP037 (for type A)105 --105 HP039, sheets 1 and 2 (for type B or C)105--105 HP044 (for connecting override swtch)
FU TILLER
63699/105--105.DOC010002 Edition: August 12th, 2003
Position of the potentiometers on the PCB:
Autodimm.
ZERO
GAIN R27
R23
Autodimm.
ZEROGAIN R27
R23
R37
R33
R47
R43
R57
R53
ZEROGAIN
ZEROGAIN
ZERO
GAIN
for Type A:
for Type B and C:
R28
SYM
R28
R38
R48
R58
SYM
SYM
SYM
SYM
R2
R2
DARKLIGHT
DARKLIGHT
Tiller FUType 105--105.NG020 E00, NG021 E00, NG022 E00
All depicted items w hich are not mentioned in the tex t are not applicable for this uni t. Since further dev elopment may necessitate making modifications to ex istingequipment, its conformity with the relev ant illustrations and draw ings is not alw ays ensured. Raytheon Anschütz w ill be under no liability whatever that may arisefrom any such differences.
14.664 RAN/ST--SU 0709 EDITION 01 1 of 1
ErsatzteilkatalogSPARE PART SCATALOGUEANSCHÜTZ
4
2 3
1
5
Stck. inQty. in
Pos. Lager--Nr.Stock--No.
Benennung Designation Zeichnungs--Nr.Part--No.
NG020E00
NG021E00
NG022E00
Herst.--CodeMFRC
Versorgungs--Nr.NSN
Tiller FU Tiller FU 105--105.NG020 E00
Tiller FU Tiller FU 105--105.NG021 E0011
Tiller FU Tiller FU 105--105.NG022 E00
2 1720728 Mikroschalter Microswitch NB14--230.00--039 1 1 1 D2865 5930--00--687--0251
1770547 Drehwiderstand Potentiometer FCP 22 E(20kOhm Lin=1% 1W)
1 D2865
1770546 Drehwiderstand Potentiometer FCP 22 EG(2x20kOhm Lin=0,5% 1W)
1 D28653
1770544 Drehwiderstand Potentiometer FCP 22 EG(4x20kOhm Lin=0,5% 1W)
1 D2865
3604100 Tiller FU--PCB Tiller FU--PCB 105--105.12 E02 1 D2865
43604101 Tiller FU--PCB Tiller FU--PCB 105--105.13 E02 1 1 D2865
5 1710006 Lampe Lamp 28 V 0,06AT 1 ¾ MGG7876
1 1 1 D2696
1 Entwicklungsstand E00 komplett nicht mehr lieferbar; Development status E00 complete no longer available
Tiller FUType 105--105.NG020 E01, NG021 E01, NG022 E01
All depicted items w hich are not mentioned in the tex t are not applicable for this uni t. Since further dev elopment may necessitate making modifications to ex istingequipment, its conformity with the relev ant illustrations and draw ings is not alw ays ensured. Raytheon Anschütz w ill be under no liability whatever that may arisefrom any such differences.
14.654 RAN/ST--SU 0708 EDITION 01 1 of 1
ErsatzteilkatalogSPARE PARTSCATALOGUEANSCHÜTZ
4
2 3
1
5
Stck. inQty. in
Pos. Lager--Nr.Stock--No.
Benennung Designation Zeichnungs--Nr.Part--No.
NG020E01
NG021E01
NG022E01
Herst.--CodeMFRC
Versorgungs--Nr.NSN
4002015 Tiller FU,basaltgrau
Tiller FU,basalt grey
105--105.NG020 E01 D2865
Tiller FU Tiller FU 105--105.NG021 E01211
4002017 Tiller FU,basaltgrau
Tiller FUBasalt grey
105--105.NG022 E01 D2865
2 1720728 Mikroschalter Microswitch NB14--230.00--039 1 1 1 D2865 5930--00--687--0251
1770547 Drehwiderstand Potentiometer FCP 22 E(20kOhm Lin=1% 1W)
1 D2865
1770546 Drehwiderstand Potentiometer FCP 22 EG(2x20kOhm Lin=0,5% 1W)
1 D28653
1770544 Drehwiderstand Potentiometer FCP 22 EG(4x20kOhm Lin=0,5% 1W)
1 D2865
3604100 Tiller FU--PCB Tiller FU--PCB 105--105.12 E02 1 D2865
43604101 Tiller FU--PCB Tiller FU--PCB 105--105.13 E02 1 1 D2865
5 1710006 Lampe Lamp 28 V 0,06AT 1 ¾ MGG7876
1 1 1 D2696
1 andere Farben auf Anfrage; other colors on request
2 nicht mehr lieferbar; no longer available
Tiller FUType 105--105.NG021 E02, NG022 E02
All depicted items w hich are not mentioned in the tex t are not applicable for this uni t. Since further dev elopment may necessitate making modifications to ex istingequipment, its conformity with the relev ant illustrations and draw ings is not alw ays ensured. Raytheon Anschütz w ill be under no liability whatever that may arisefrom any such differences.
14.655 RAN/ST--SU 0708 EDITION 01 1 of 1
ErsatzteilkatalogSPARE PARTSCATALOGUEANSCHÜTZ
4
2 3
1
5
Stck. inQty. in
Pos. Lager--Nr.Stock--No.
Benennung Designation Zeichnungs--Nr.Part--No.
NG021E02
NG022E02
Herst.--CodeMFRC
Versorgungs--Nr.NSN
4002472 Tiller FU,basaltgrau
Tiller FU,basalt grey
105--105.NG021 E02 D2865
114002474 Tiller FU,
basaltgrauTiller FU,basalt grey
105--105.NG022 E02 D2865
2 1720728 Mikroschalter Microswitch NB14--230.00--039 1 1 D2865 5930--00--687--0251
1770546 Drehwiderstand Potentiometer FCP 22 EG(2x20kOhm Lin=0,5% 1W)
1 D2865
31770544 Drehwiderstand Potentiometer FCP 22 EG
(4x20kOhm Lin=0,5% 1W)1 D2865
43609838 Tiller FU--PCB Tiller FU--PCB 105--105.15 1 1 D2865
5 1710006 Lampe Lamp 28 V 0,06AT 1 ¾ MGG7876
1 1 D2696
1 andere Farben auf Anfrage; other colors on request
NG021
NG022
NG022