Ftx-g Technical Data

9
Indoor Units • R-410A • FTX-GV1B 1 1 Split Sky Air • Indoor Units 1 1 Features I n d o o r U n i t S p l i t S k y A F T X - G V 1 B R - 4 1 0 A Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Lightweight and compact Consumes up to 30% less energy than non-inverter units Dual air discharge flow for better air distribution ECONO mode decreases power consumption so that other appliances that need large power supply can be used Indoor unit On/Off switch Indoor unit silent operation Titanium apatite photocatalytic air purification filter Anticorrosion treatment of outdoor heat exchanger fin Powerful mode can be selected for rapid cooling or heating Energy saving during stand by mode: reduction of energy from 10W to 2W optional 5 steps standard

Transcript of Ftx-g Technical Data

Page 1: Ftx-g Technical Data

• Indoor Units • R-410A • FTX-GV1B

11

1

1 Features

oor Unit it Sky A -GV1B 10A

Ind Spl FTX R-4 • Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean.

• Lightweight and compact

• Consumes up to 30% less energy than non-inverter units

• Dual air discharge flow for better air distribution

• ECONO mode decreases power consumption so that other appliances that need large power supply can be used

• Indoor unit On/Off switch

• Indoor unit silent operation

• Titanium apatite photocatalytic air purification filter

• Anticorrosion treatment of outdoor heat exchanger fin

• Powerful mode can be selected for rapid cooling or heating

• Energy saving during stand by mode: reduction of energy from 10W to 2W

optional

5 steps standard

• Split Sky Air • Indoor Units

Page 2: Ftx-g Technical Data

3

12

• Indoor Units • R-410A • FTX-GV1B

2 Specifications

2-1 FOR INDOOR UNITS ONLY FTX20GV1B FTX25GV1B FTX35GV1B

Nominal input (Indoor only)

Cooling kW 0.04 0.04 0.04Heating kW 0.04 0.04 0.04

2-2 TECHNICAL SPECIFICATIONS FTX20GV1B FTX25GV1B FTX35GV1B

Casing Colour WhiteDimensions Packing Height mm 344 344 344

Width mm 840 840 840Depth mm 263 263 263

Unit Height mm 283 283 283Width mm 770 770 770Depth mm 198 198 198

Weight Unit kg 7 7 7Packed Unit kg 11 11 11

Heat Exchanger

Dimensions Length mm 610 610 610Nr of Rows 2 2 2Fin Pitch mm 1.4 1.4 1.4Nr of Stages 14 14 14

Tube type Hi-XA (7)Fin Type ML fin (Multi louvre)

Fan Type Cross flow fanQuantity 1 1 1

Air Flow Rate Cooling High m³/min 9.1 9.2 9.3Medium m³/min 7.4 7.6 7.7Low m³/min 5.9 6.0 6.1Silent Operation

m³/min 4.7 4.8 4.9

Heating High m³/min 9.4 9.7 10.1Medium m³/min 7.8 8.0 8.4Low m³/min 6.3 6.3 6.7Silent Operation

m³/min 5.5 5.5 5.7

Cooling High cfm 321 325 328Medium cfm 261 268 272Low cfm 208 212 215Silent Operation

cfm 166 169 173

Heating High cfm 331 342 356Medium cfm 276 283 295Low cfm 222 222 235Silent Operation

cfm 194 194 201

Fan Motor Quantity 1 1 1Model MM6C02J2VNumber of steps 5 steps, quiet, auto

Motor Speed (cooling)

High rpm 1,210 1,250 1,300Medium rpm 990 1,030 1,070Low rpm 780 820 850Silent Operation

rpm 630 630 680

Speed (heating)

High rpm 1,260 1,300 1,340Medium rpm 1,090 1,110 1,150Low rpm 920 920 960Silent Operation

rpm 820 820 850

Fan Motor Output (high)

W 16 16 16

• Split Sky Air • Indoor Units 2

Page 3: Ftx-g Technical Data

• Indoor Units • R-410A • FTX-GV1B

12

3

2 Specifications

Cooling Sound Power High dBA 55 56 57Sound Pressure

High dBA 39 40 41Medium dBA 33 33 34Low dBA 25 26 27Silent Operation

dBA 22 22 23

Heating Sound Power High dBA 55 56 57Sound Pressure

High dBA 39 40 41Medium dBA 34 34 35Low dBA 28 28 29Silent Operation

dBA 25 25 26

Refrigerant Type R-410APiping connections

Liquid (OD) Diameter (OD)

mm 6.35 6.35 6.35

Gas Diameter (OD)

mm 9.52 9.52 9.52

Drain Diameter (OD)

mm 18 18 18

Heat Insulation Both liquid and gas pipesAir Filter Removable/washable/Mildew proofAir direction control Right, Left, Horizontal, DownwardTemperature control Microcomputer controlStandard Accessories

Item Installation manualQuantity 1 1 1Item Operation manualQuantity 1 1 1Item Wireless remote controlQuantity 1 1 1Item BatteriesQuantity 2 2 2Item Remote control holderQuantity 1 1 1Item Mounting plateQuantity 1 1 1Item Fixing screw for indoor unitQuantity 2 2 2Item Titanium apatite photocatalytic air purification filterQuantity 2 2 2

2-3 ELECTRICAL SPECIFICATIONS FTX20GV1B FTX25GV1B FTX35GV1B

Power Supply Name V1Phase 1~Frequency Hz 50 50 50Voltage V 220-230-240

Current Nominal running current (RLA)

Cooling A 0.18 0.18 0.18Heating A 0.18 0.18 0.18

Wiring connections

For Power Supply

Quantity 3 3 3

2-2 TECHNICAL SPECIFICATIONS FTX20GV1B FTX25GV1B FTX35GV1B

• Split Sky Air • Indoor Units

Page 4: Ftx-g Technical Data

3

13

• Indoor Units • R-410A • FTX-GV1B

3 Dimensional drawing & centre of gravity

3 - 1 Dimensional drawingFTX20-35GV

3D058481

The mark (→) shows piping direction

Front panel fixing screws ( Inside)

Signal receiverOperation lampTimer lampIndoor unit ON/OFF switchRoom temp. thermistor (Inside)

Rear

Air flow (Indoor)

(Spa

ce fo

r perf

orman

ce)

Terminal block with earth terminal (Inside)

General rating name plate

Model name plate

Bottom

Signal transmitter

Right

Flaps

Up/down (Automatic)

Fan

Heating Dry

Right/left (Manual)

50Min.(Space for maintenance)

50Min.(Space for maintenance)

30Mi

n.

Including mounting plate

Gas pipe Ø 9,5 Cut(The length of pipe outside the unit: About 400)

Liquid pipe Ø 6,4 Cut(The length of pipe outside the unit: About 400)

Drain hose( Connecting part I.D. Ø 14O.D. Ø 16The hose length of ouside the unit is about 450)

Wall hole for embedded pipingØ 65 Hole Wall hole

Ø 65 Hole

Left

STANDARD LOCATIONS OF WALL HOLESINFRARED REMOTE CONTROL

(ARC433A89)

BLADE ANGLE

REQUIRED SPACE

Cooling

• Split Sky Air • Indoor Units 4

Page 5: Ftx-g Technical Data

• Indoor Units • R-410A • FTX-GV1B

13

5

3 Dimensional drawing & centre of gravity

3 - 2 Centre of gravity

FTX20-35GV

4D059099

• Split Sky Air • Indoor Units

Page 6: Ftx-g Technical Data

3

14

• Indoor Units • R-410A • FTX-GV1B

4 Piping diagram

FTX20-35GV

4D058926

Refrigerant flow

Heat exchanger

Fan motor

Cross flow fan

Thermistor on heat exch.

9.5 Cut

INDOOR UNIT

Field piping(9.5Cut)

Field piping(6.4Cut)

7.0 Cut

7.0 Cut

7.0

Cut

7.0 Cut

4.8 Cut

Cooling

Heating

• Split Sky Air • Indoor Units 6

Page 7: Ftx-g Technical Data

• Indoor Units • R-410A • FTX-GV1B

15

7

5 Wiring diagram

5 - 1 Wiring diagram

FTX20-35GV

3D058454

OPTION

: Frame ground: Fuse: Harness: Pilot lamp: Fan motor: Swing motor: Printed circuit board: Thermistor: Connector: Operation switch: Terminal strip: Protective earth

CAUTIONNote that operation will restart automatically if the main power supply is turned off and then back on again.

OUTDOOR

FIELD WIRING

INDOOR

TRANSMISSION CIRCUIT

RECTIFIER

SIGNAL RECEIVER

INFRAREDREMOTE

CONTROL

NOTE1 1. PCB3 is shows the case of option

connection.

• Split Sky Air • Indoor Units

Page 8: Ftx-g Technical Data

3

16

• Indoor Units • R-410A • FTX-GV1B

6 Sound data

6 - 1 Sound pressure spectrum

3D058955

NOTES1 Operating conditons:

230V 50Hz: 50 Hz 230V (H): 50 Hz 230V (L)

Cooling2 Measure in anechoic room3 Location of microphone

4 Operation noise differs with operation and ambient conditions.

Octav

e ban

d sou

nd pr

essu

re lev

el d

B(0d

B=0.0

002μ

bar)

Approximate threshold hearing for continuous noise

FTX20GV COOLING

1m

0.8m

Octave band center frequency (Hz) 3D058955

NOTES1 Operating conditons:

230V 50Hz: 50 Hz 230V (H): 50 Hz 230V (L)

Heating2 Measure in anechoic room3 Location of microphone

4 Operation noise differs with operation and ambient conditions.

Octav

e ban

d sou

nd pr

essu

re lev

el d

B(0d

B=0.0

002μ

bar)

Approximate threshold hearing for continuous noise

FTX20GV HEATING

1m0.8

m

Octave band center frequency (Hz)

3D058956

NOTES1 Operating conditons:

230V 50Hz: 50 Hz 230V (H): 50 Hz 230V (L)

Cooling2 Measure in anechoic room3 Location of microphone

4 Operation noise differs with operation and ambient conditions.

Octav

e ban

d sou

nd pr

essu

re lev

el d

B(0d

B=0.0

002μ

bar)

Approximate threshold hearing for continuous noise

FTX25GV COOLING

1m

0.8m

Octave band center frequency (Hz)3D058956

NOTES

1 Operating conditons:230V 50Hz

: 50 Hz 230V (H): 50 Hz 230V (L)

Heating2 Measure in anechoic room3 Location of microphone

4 Operation noise differs with operation and ambient conditions.

Octav

e ban

d sou

nd pr

essu

re lev

el d

B(0d

B=0.0

002μ

bar)

Approximate threshold hearing for continuous noise

FTX25GV HEATING

1m

0.8m

Octave band center frequency (Hz)

• Split Sky Air • Indoor Units 8

Page 9: Ftx-g Technical Data

• Indoor Units • R-410A • FTX-GV1B

16

9

6 Sound data

6 - 1 Sound pressure spectrum

3D058957

NOTES1 Operating conditons:

230V 50Hz: 50 Hz 230V (H): 50 Hz 230V (L)

Cooling2 Measure in anechoic room3 Location of microphone

4 Operation noise differs with operation and ambient conditions.

Octav

e ban

d sou

nd pr

essu

re lev

el d

B(0d

B=0.0

002μ

bar)

Approximate threshold hearing for continuous noise

FTX35GV COOLING

1m

0.8m

Octave band center frequency (Hz) 3D058957

NOTES1 Operating conditons:

230V 50Hz: 50 Hz 230V (H): 50 Hz 230V (L)

Heating2 Measure in anechoic room3 Location of microphone

4 Operation noise differs with operation and ambient conditions.

Octav

e ban

d sou

nd pr

essu

re lev

el d

B(0d

B=0.0

002μ

bar)

Approximate threshold hearing for continuous noise

FTX35GV HEATING

1m0.8

m

Octave band center frequency (Hz)

• Split Sky Air • Indoor Units