FT400 SEAMETRICS

download FT400 SEAMETRICS

of 4

Transcript of FT400 SEAMETRICS

  • 8/10/2019 FT400 SEAMETRICS

    1/4

    GENERAL INFORMATION

    The FT400-Series ow computers are microcontroller-based

    indicator/transmitters that display ow rate and total and

    provide output signals. The FT415 is battery-powered and

    provides a scalable pulse output. The FT420 is powered by

    external DC voltage and has both pulse and 4-20 mA analog

    outputs. When the FT420 is being used in the 4-20 mA mode,

    it is a two-wire or loop-powered device, meaning that the

    4-20 mA output signal doubles as its power supply.

    The addition of a dual-relay output board (FT420 only) allows

    for certain applications requiring contact output isolation (e.g.,

    certain metering pumps and water treatment controls). Dual

    solid state relays provide exactly the same pulse output as the

    standard unit, and each can signal one external device. A non-

    resettable total is also available. The FT420 can be ordered in

    a plastic enclosure with a 115 Vac power supply for use with

    mechanical meters, or with a built-in 115 Vac/12-24 Vdc dual

    power supply for magmeters.

    Both the FT415 and the FT420 can be factory-mounted on the

    meter or remotely wall mounted with the brackets provided. The

    FT420 is also available as a panel mount with an open back fo

    easy installation in the users own electrical enclosure. Most

    FT400s can be converted from wall-to-meter or meter-to-wal

    mount congurations after installation if needed.

    Housings for the wall and meter-mounted models are rugged

    cast aluminum, potted and gasketed for maximum environ

    mental protection. A membrane keypad allows settings to be

    changed without removing the cover. (Password protection, a

    standard feature on the FT420, can be used to prevent settings

    from being changed.)

    FEATURES

    Simple SetupBattery (FT415) or Loop Powered (FT420)

    Remote or Flow Sensor Mounted Indicator

    Rugged Metallic Housing

    Non-volatile Memory

    APPLICATIONS

    Water Treatment

    Water Utility

    Industrial Chemical Handling

    FT400-SERIES

    Rate/Total Indicator

    FT420

    FT415

    I I

    9 0 0 1 : 2 0 0 8CERTIFIED COMPANYISO

  • 8/10/2019 FT400 SEAMETRICS

    2/4

    Lower Housing

    Setup Keys**

    Cover Screws

    Electronics Module

    Wall-Mount Brackets

    Strain Relief

    Display

    FEATURES

    FT400-SERIES

    Rate/Total Indicator

    SPECIFICATIONS*

    Lithium "C", 3.6 Vdc, replaceable. Estimated life is3-5 years depending on usage.

    6-digit autorange, 1/2" character height

    8-digit, 5/16" character height

    Scaled Pulse output (0.1 sec duration 6.1 Hz max) (or High Alarm output or Low Alarm output)

    Sensor pass-through Pulse output (unscaled)

    None

    0.1 - 9999999.9 units/pulse

    Micropower GMR Sensor (square wave)

    1.0 - 150 pulses/second

    .001 - 99999.999

    .01 - 999999.99

    -30 to 65 C (-22 to 148 F)

    NEMA 4X, IP66

    Power

    Display Rate

    Total

    Outputs Current Sinking Pulse

    Analog

    Pulse Output Range

    Input

    Input Range

    K-Factor Range

    Flow Alarm Output Range

    Operating Temperature

    Environmental

    FT415 FT420

    *Specications subject to change Please consult our website for current data (www.seametrics.com).

    12-30 Vdc, 4mA (4-20 mA when loop-powered)

    6-digit autorange, 1/2" character height

    8-digit, 5/16" character height

    4-20 mA loop; 24-30 Vdc

    0.1 - 9999999.9 units/pulse

    5V pulse or contact closure

    1.0 - 1,500 pulses/second

    .001 - 99999.999

    .01 - 999999.99

    -30 to 65 C (-22 to 148 F)

    NEMA 4X, IP66

    **The FT420 includes password protection for tamper preventionwhen needed

    FT420 with -27 or -65 Option

  • 8/10/2019 FT400 SEAMETRICS

    3/4

    SET

    Electronic

    Metering Pump

    12-32 VdcLoop Power Supply4-20 mA Device

    Analog Output

    Scaled Pulse Output

    Pulse Pass-Through

    Remote Display

    or PLC

    1 2 3 4

    Flow Sensor

    Flow Sensor Input

    4-20 mA Output

    SE

    Panel Cutout

    R .38 Max, Typ.

    3.85 Typ

    3.620

    +.03/-.00Typ

    .70 x .18 Clamp

    Area, Typ2.97"

    SET

    3.93"

    4.60"

    3.93"

    2.06"2341678.9

    10.5

    FT415/FT420with Wall Mount Brackets

    DIMENSIONS

    FT400-SERIES

    Rate/Total Indicator

    FT415/FT420Sensor Mount

    FT420PanelMount

    POSSIBLE APPLICATIONS

    3.00"

    .20 Max.

    Panel Thickness

    1.50

    .36

    FT420 ONLY

  • 8/10/2019 FT400 SEAMETRICS

    4/4

    Seametrics Incorporated 19026 72nd Avenue South Kent, Washington 98032 USA

    (P) 253.872.0284 (F) 253.872.0285 1.800.975.8153 www.seametrics.comLT-65650010-080514

    8/5/2014

    HOW TO ORDER

    MODEL MOUNTING OPTIONS

    Wall mount = W

    Panel mount = P

    Meter mount = See appropriate

    meter specifcation to order meter

    mounted units.

    ACCESSORIES

    Built-in 115 Vac/12-24 Vdc dual power supply(FT420W only, use with magmeters) = -27

    Tamper-evident = -32

    Non-resettable total = -64

    Built-in 115 Vac power supply(FT420W only, use with mechanical meters) = -65

    Dual relay output (FT420 only) = -98

    Battery-powered indicator = FT415

    Loop-powered indicator/transmitter = FT420

    Data logger (wall mount) = DL76W

    Power converter, plug-in, 115 Vac, 24 Vdc = PC3

    Dual power supply, plug-in, 115 Vac, 12/24 Vdc = PC42

    Protective cover, hinged = 101949

    Mounting kit, wall-to-meter conversion = 102632

    Mounting kit, meter-to-wall conversion = 102633

    LMI pump power cable = 100013

    LMI pulse out cable = 100039

    FT400-SERIES

    Rate/Total Indicator

    CONTACT YOUR SUPPLIER