FSC Cert- Basement & Ground floor

1
B C D E F H I J K L M P 35 m² Electrical Plant Room 36 m² Boiler Room 32 m² Solar Plant Room 45 m² Water Plant Room 24 m² Hall 5 m² Service Riser 114 FD30 115 FD30 125 FD30 138 139 FD30 140 FD30 141 FD60 142 FD30 CarPark Exit CarPark Entrance 28 m² Stair 4 18 m² Building Contol Centre 7 m² Bed Lift 5 m² Lift 37 m² Lobby FD 31 FD30 37.5m (T D ) 26.1m (TD) 69.000° 9.9m (OD) 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 13 A B C D E F H I J K L M P 5300 6 FD30 8 FD30 9 FD30 10 FD30 11 FD30 12 FD30 13 FD30 14 FD30 15 FD30 17 FD30 18 FD30 34 FD30 36 FD30 37 FD30 38 FD30 39 FD30 42 FD30 43 FD30 44 FD30 45 FD30 46 FD30 47 FD30 48 FD30 49 FD30 50 FD30 109 FD30 110 FD30 111 FD30 16 m² Book TR Room 24 m² Speech Therapy 20 m² Stair 3 27 m² Speech Therapy 14 m² Book TR Room 16 m² Medical Store 4 m² WC & Shower 4 m² Staff WC 6 m² Hall 9 m² Womens Toilets 4 m² Womens WC 8 m² Mens Toilets 5 m² Mens WC 18 m² Wound Clinic 11 m² Medical Store 18 m² Wound Clinic 15 m² Bookable Room 28 m² Family Rm/Care Doc 34 m² Reception 30 m² Waiting Area 20 m² Community Welfare 15 m² Bookable Room 18 m² Room 17 m² Child Health 17 m² Sound Proof Room 14 m² Stairs 32 m² HSE Circulation 359 m² Pharmacy 120 m² Medical Services Rm1 116 m² Medical Services/Storage 19 m² HSE Store 11 m² HSE Hall 34 m² HSE Dr Room 51 m² HSE Reception & Treatment Rm 16 m² HSE Office 127 FD60 128 FD60 69 FD60 81 FD30 80 FD30 79 FD30 78 FD30 129 FD30 15 m² Stairs 1 29 m² Stair 4 112 m² Restaurant /Caffe 80 m² Medical Services 67 m² OT GA Room 72 FD60 77 FD30 71 FD30 76 FD30 70 FD30 73 FD60 74 FD60 75 FD60 82 FD60 9 m² WC F 5 m² Hall 9 m² WC M 14 m² Storage 7 m² Hall 4 m² WC 107 106 FD60 108 136 FD60 135 FD60 133 FD60 91 m² Room 4664 2703 5190 14.2m (OD) 27.1m (TD) 9.3m (TD) 15.6m (TD) 18.4m ( TD ) 6.9m (OD) 5.6m (TD) www.autodesk.com/revit Scale LECTURER Drawn by Date Project number Institute of Technology Carlow BSc. in Architectural Technology Year 3 2015-2016 1 : 200 19/04/2016 18:16:59 Fire Certificate Plans Project Number 3 Carlow Primary Health Care Centre 22/04/2016 Xhevdet Haliti Dan O Sullivan, Noel Dunne, Mark Duffy A129 1 : 200 Fire Basement floor plan 1 1 : 200 Fire Ground floor plan 2 LEGEND : Travel Distances: - One Direction: OD - Two Direction: TD 30 min protected corridor in accordance with section 1.2.5.1. and table A1 TGD B 2006 60 min protected stair wall in accordance with table A2 TGD,Part B 2006. i.e. top storey served not more than 5m above Ground level 90 min protected stair well in accordance with table A2 TGD, Part B 2006. Top storey served not more than 20m above Ground Level 90 min compartment wall/floor in accordance with section 3.2, table A2 and appendix C, TGD B 2006 30 min fire resistant door set in accordance with BS476 Part 22, fitted with Intumescent strips and smoke seals. Doorset to be fitted with automatic self-closing device which shall be capable of closing the for from any angle and against any latch fitted Disabled refuge area (1400x900mm). Two way communication to the internal refuge area only Emergency escape lighting to comply with table 1.8 TGD B- to be designed , installed and certified in accordance with IS 3217:20013. Fire detection system type L1 to be designed, certified in accordance with IS 3218:2009(2013) The use, inspection and maintenance of fire extinguishers to be designed , installed and certified in accordance with IS 291:2002 Steel columns, beams and portal frames used to support load bearing, fire resisting elements of structure to be protected and to give 90min fire rating 60 min fire resistant door set in accordance with BS476 Part 22, fitted with Intumescent strips and smoke seals. Doorset to be fitted with automatic self-closing device which shall be capable of closing the for from any angle and against any latch fitted NOTES: (1) Refers to area of room or storey, as appropriate, with area calculated in accordance with Section 1.0.10(a) of TGD-B 2006. (2) Occupancy load factors as per Table 1.1 of TGD-B 2006. (3) Such areas will generally be unoccupied or alternatively will be occupied by the same persons within the remainder of the premises and therefore double counting of both areas are avoided. (4) Number of persons to such rooms taken as two (i.e. a patient and a consultant)

Transcript of FSC Cert- Basement & Ground floor

Page 1: FSC Cert- Basement & Ground floor

B

CD

E

F

H

I

J

K

L

M

P

35 m²Electrical Plant Room

36 m²Boiler Room

32 m²Solar Plant Room

45 m²Water Plant Room

24 m²Hall

5 m²Service Riser

114FD30

115FD30

125FD30

138139FD30

140FD30

141FD60

142FD30

CarPark Exit

CarPark Entrance

28 m²Stair 4

18 m²Building Contol Centre

7 m²Bed Lift

5 m²Lift

37 m²Lobby

FD 31FD30

37.5m (TD)

26.1m (TD

)

69.000°

9.9m (OD)

12

3

45

67

89

10

11

12

14

15

16

17

18

19

20

21

22

23

24

13

A

B

CD

EF

H

I

J

K

L

M

P

5300

6FD30

8FD30

9FD30

10FD3011

FD3012FD3013

FD3014FD30

15FD30

17FD30

18FD30

34FD30

36FD30

37FD30

38FD30

39FD30

42FD30

43FD30

44FD30

45FD30

46FD30

47FD30

48FD30

49FD30

50FD30

109FD30

110FD30

111FD30

16 m²Book TR Room

24 m²Speech Therapy

20 m²Stair 3

27 m²Speech Therapy

14 m²Book TR Room 16 m²

Medical Store

4 m²WC & Shower

4 m²Staff WC

6 m²Hall

9 m²Womens Toilets

4 m²Womens WC

8 m²Mens Toilets

5 m²Mens WC

18 m²Wound Clinic

11 m²Medical Store 18 m²

Wound Clinic

15 m²Bookable Room

28 m²Family Rm/Care Doc

34 m²Reception

30 m²Waiting Area

20 m²Community Welfare

15 m²Bookable Room

18 m²Room

17 m²Child Health

17 m²Sound Proof Room

14 m²Stairs

32 m²HSE Circulation

359 m²Pharmacy

120 m²Medical Services Rm1

116 m²Medical Services/Storage

19 m²HSE Store

11 m²HSE Hall

34 m²HSE Dr Room

51 m²HSE Reception & Treatment Rm

16 m²HSE Office

127FD60

128FD60 69

FD60 81 FD30

80 FD30

79FD30

78FD30

129

FD30

15 m²Stairs 1

29 m²Stair 4

112 m²Restaurant /Caffe

80 m²Medical Services 67 m²

OT GA Room

72FD60

77 FD30

71 FD30

76FD30

70 FD30

73FD60

74FD60

75 FD60

82 FD60

9 m²WC F

5 m²Hall

9 m²WC M 14 m²

Storage 7 m²Hall

4 m²WC

107 106FD60

108

136FD60

135

FD60

133

FD60

91 m²Room

4664

2703

5190

14.2m (O

D)

27.1m (TD)9.3m (TD)

15.6m (TD)

18.4m (TD)

6.9m

(OD)

5.6m (TD

)

www.autodesk.com/revit

Scale

LECTURER

Drawn by

Date

Project number

Institute of Technology CarlowBSc. in Architectural Technology

Year 3 2015-2016

1 : 200

19/0

4/20

16 1

8:16

:59

Fire Certificate Plans

Project Number 3

Carlow Primary Health Care Centre

22/04/2016

Xhevdet Haliti

Dan O Sullivan, Noel Dunne,Mark Duffy

A129

1 : 200Fire Basement floor plan1

1 : 200Fire Ground floor plan2

LEGEND:Travel Distances:

- One Direction: OD- Two Direction: TD

30 min protected corridor in accordancewith section 1.2.5.1.and table A1 TGD B 2006

60 min protected stair wall in accordancewith table A2 TGD,Part B 2006. i.e. topstorey served not more than 5m aboveGround level

90 min protected stair well in accordancewith table A2 TGD, Part B 2006. Top storeyserved not more than 20m above Ground Level

90 min compartment wall/floor in accordancewith section 3.2, table A2 and appendix C,TGD B 2006

30 min fire resistant door set in accordancewith BS476 Part 22, fitted with Intumescentstrips and smoke seals. Doorset to be fittedwith automatic self-closing device which shallbe capable of closing the for from any angleand against any latch fitted

Disabled refuge area (1400x900mm). Two waycommunication to the internal refuge area only

Emergency escape lighting to comply with table 1.8 TGD B-to be designed , installed and certified in accordance withIS 3217:20013.

Fire detection system type L1 to be designed, certified inaccordance with IS 3218:2009(2013)

The use, inspection and maintenance of fire extinguishersto be designed , installed and certified in accordance withIS 291:2002

Steel columns, beams and portal frames used to supportload bearing, fire resisting elements of structure to beprotected and to give 90min fire rating

60 min fire resistant door set in accordancewith BS476 Part 22, fitted with Intumescentstrips and smoke seals. Doorset to be fittedwith automatic self-closing device which shallbe capable of closing the for from any angleand against any latch fitted

NOTES:(1) Refers to area of room or storey, as appropriate, with area calculated in accordance with Section 1.0.10(a) of TGD-B 2006.(2) Occupancy load factors as per Table 1.1 of TGD-B 2006.(3) Such areas will generally be unoccupied or alternatively will be occupied by the same persons within the remainder of the

premises and therefore double counting of both areas are avoided.(4) Number of persons to such rooms taken as two (i.e. a patient and a consultant)