Fritz ASN CT Physics 2017 - American Society of Neuroimaging Annual Meeting/Fritz ASN CT... ·...
Transcript of Fritz ASN CT Physics 2017 - American Society of Neuroimaging Annual Meeting/Fritz ASN CT... ·...
12/21/2016
1
Joseph V. Fritz, PhDNandor Pintor, MDDent Neurologic InstituteASN 2017Friday, January 20, 2017
� Siemens Medical Systems
� Research Agreement
� Philips Healthcare
� Research Agreement
� AAN and ASN Committees
MRI� Internal source (protons)
encode soft tissue character
� Tomographic Acquisition any Plane
� 3 Tesla, 80 mT/m, 200 T/m/s,min TR, min TE
� 4 W/kg, Magnetic force
CT� External source (x-ray)
encode tissue density
� Tomographic Acquisition Axial Plan, MPR any Plane
� 320 slice @ 0.5mm, 250ms rotation, dose reduction
� 3 milliSieverts nature50 mSv annual limit
� CT
� Keep Dose Similar to Background
� Reformating
� Dynamic / Functional Imaging
� Tissue Characterization
Single Rotation for Full Volume (16cm)
Multi-Spectral
� MRI
� Speed
� Artifact Reduction
� Functional and Metabolic Imaging
Field Strength (SNR, Speed, Resolution)
Parallel Receive and Transmit
MRI� Contrast or Non-Contrast
� 0.5 x 0.5 x 1 mm3
� Flow and Metal Artifacts
� Minutes
� Advances in fast dynamics, functional, artifact reduction
CT� Contrast (+pre if subtraction)
� 0.5 x 0.5 x 0.5 mm3
� Stent/Ca artifacts
� Seconds
� Advances in bone removal, dynamics
12/21/2016
2
Radio/TV
Visible
Microwaves
Xray
http://www.hardhack.org.au/xraydtt
Harder beam,More penetration
J. Nucl. Med. Technol. March 1, 2005 vol 33 no. 1 3-18
Photoelectric Dominates Soft
Tissue Attenuation
Compton Dominates Dense
Material Attenuation (Bone, Iodine)
� Stretch the Slinky
� Faster, less dose
� Blurred slices
12/21/2016
3
FoV / Matrix (eg 0.5mm in Brain)
Detector
Dimension
4 cm 8 cm 16 cm
Single Rotation
64 detector row CT coverage
Single Rotation
160 detector row CT coverage
Single Rotation
320 detector row CT coverage
12/21/2016
4
ReviewTissue HU
Air -1000
Lung -500
Fat -100 to -50
Water 0
CSF +15
Blood +30 to + 45
Muscle +1- to +40
Grey Matter +37 to +45
White Matter +20 to +30
Soft Tissue, Contrast +100 to +300
Bone +700 (Cancerous) to +3000 (dense bone)
125 mAs 200 mAs
� CT Dose Index: Radiation from the Tube (CTDI, in mGy)
� Increases with Current (mA), time (s, mA*s), Voltage (kV)
� Need less if Detector more sensitive, less overlap, etc
� Dose-Length Product (DLP, in mGy*cm)
� Total Amount of Radiation The Body
� Multiply Dose times Coverage in cm
� Effective Dose on a Person in milliSieverts (mSv)
� Amount of Radiation Absorbed (IT IS CUMULATIVE)
� Multiply DLP/1000 by “k-factor” (2.2 in head, 5 in neck, 15 in body)
� eg Background < 3 mSv; Professionals < 50 mSv / Year
Peds: 2-5x more
Exam Effective Body Dose
(mSv)
Absorbed Organ Dose
(mGy)
Annual Background* 2.4 2.4
Chest x-ray 0.02 0.01 – 0.15
Head CT 1 – 2 56
Screening Mammo 0.4 3
Abdomen CT 8 14
Chest CT 5 – 7 13
CT Colonography 6 – 11
Chest-Ab-Pelv CT 9.9 12
Cardiac CT 9 – 12 400– 100
Barium enema 15 15
Neonatal Abdominal CT 20 20
*99% less than 7 mSv per year
12/21/2016
5
Innovations in Reconstruction
Detector
Material
1995 2000 2005 2010 2015
Filtering
4 slice
Tube Modulation
Filtering
16 Slice
New Recon Methods
64 Slice
ECG Modulation
256 Slice
Iterative Reconstruction
320 Slice,
Active Collimation,
Recon
Do
se
Dynamic
Scan Mode
Collimation Pitch kVp mARotation
TimeScan
RangeCTDImGy
DLPmGy.cm
Effective Dose
K
Volume 0.5mm x 240 NA 135 250 0.75s 120mm 44.7 571.9 1.2 mSv 0.0021
With Iterative ReconWithout
CTDImGy
DLPmGy.cm
Effective Dose
K
44.7 571.9 1.2 mSv 0.0021
CTDImGy
DLPmGy.cm
Effective Dose
K
70.0 1119.7 2.35 mSv 0.0021
(31% ↓ dose compared to helical acquisition)
Courtesy of Dr. Greenberg,
Arkansas Children’s Hospital
Accessory Occipital Suture
12/21/2016
6
� In direction of greatest attenuation
12/21/2016
7
Temporal uniformity,
no table movement
No temporal uniformity,
rapid table movement
12/21/2016
8
Scan Mode
Collimation Pitch kVp mARotation
TimeScan
RangeCTDImGy
DLPmGy.cm
Effective Dose
K
Dynamic 0.5mm x 320 * 80 mA boost 0.5 160mm 138 2206.3 4.6 mSv 0.0021
rCBV rCBF MTT
CBF = CBVMTT
Courtesy Erin Angel, Toshiba
CBV = Autoregulation
CBF = Low Flow
MTT = vasodilation
TTP, Delay = Stenosis, Colateralization
� Tissue at risk: relative MTT
� optimal threshold of 145%
� Infarct core: absolute CBV
� optimal threshold 2.0 ml/100g
Wintermark, Stroke. 2006; 37: 979-985
12/21/2016
9
� Differentiate Bone,
Contrast� CTA without bone
removal
� Eliminate Calcification Artifact
� Metal Artifact
Reduction� Plaque
Characterization
Ratio of
Detected HUs
*AN Primak, et al, AJR:195, Nov 2010
(RITRadiology.com)
� Isotropic Voxels (Image in Any Plane)
� Wide detector array � 320 x 0.5mm (640 x 0.25mm)
� Dose Reduction Methods
� Faster Imaging� Fast Gantry Rotation (0.25 s)
� Multiple X-ray Tubes
� Dynamic Imaging. Functional Assessment. Angio/Perfusion
� Artifact Reduction� Multi-Energy