FRISO KRAMER DIRECT CLASS 1/II IMPORTANT SPECIFICATIONS€¦ · 40°C 0,22 FRISO KRAMER DIRECT...

5
m 2 65 3-5m 60-76 mm IEC 598 80 20 IP.. Ta temp O mm 0,22 40°C FRISO KRAMER DIRECT CLASS 1/II Lightsource: LED Voltage: 230 V AC 50 Hz Power factor: > 0,90 Pole diameter: 60 mm Driver: Philips Xitanium Required tools 660 mm 458 mm 475 mm Ø 60 mm Friso Kramer Direct IMPORTANT 1. Follow the instructions of this manual 2. Use IEC tools 3. Replace defective parts 4. Point the hexbolt towards the street 5. The hexbolts have to be tightened with a torque of 4-5 Nm 6. Cable: 1,5 mm 2 or 1,0 mm 2 with rated voltage and current: 250V / > 1A 7. Terminal block in the pole is not included 8. Installation requires advice from a qualified technician 9. Lightwell B.V. retains final explanation rights 10. The external cable of this luminaire can not be replaced. If the cable is damaged, the luminaire should be removed 11. The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person SPECIFICATIONS 1. LED power is set in the factory 2. Light color standard 3000K/4000K 3. CLO, Dimprofile is set in the factory PARTS 1. Luminaire with asymmetric optics 2. TOP LID: 8718843016868 (RAL7040) 3. TOP SCREW: 8718843016936 (RAL7040) 4. LED module: article number on cord and on LED module 5. DRIVER 9 kg IP65 IK09 Ø19 LW-FKLD TOOL 8718843020858 16 Nm Torque 8718843017353 - LW-FKLD manual C1-C2 EN 1.3

Transcript of FRISO KRAMER DIRECT CLASS 1/II IMPORTANT SPECIFICATIONS€¦ · 40°C 0,22 FRISO KRAMER DIRECT...

Page 1: FRISO KRAMER DIRECT CLASS 1/II IMPORTANT SPECIFICATIONS€¦ · 40°C 0,22 FRISO KRAMER DIRECT CLASS 1/II Lightsource: LED Voltage: 230 V AC 50 Hz Power factor: > 0,90 Pole diameter:

m2

65 3-5m 60-76mm IEC 598 80 20

IP..Tatemp

O mm

0,2240°C

FRISO KRAMER DIRECT CLASS 1/IILightsource: LEDVoltage: 230 V AC 50 HzPower factor: > 0,90Pole diameter: 60 mmDriver : Philips Xitanium

Required tools660 mm

458

mm

475

mm

Ø 60 mmFriso Kramer Direct

IMPORTANT1. Follow the instructions of this manual2. Use IEC tools3. Replace defective parts4. Point the hexbolt towards the street5. The hexbolts have to be tightened with a torque of 4-5 Nm6. Cable: 1,5 mm2 or 1,0 mm2

with rated voltage and current: 250V / > 1A 7. Terminal block in the pole is not included8. Installation requires advice from a qualified technician9. Lightwell B.V. retains final explanation rights10. The external cable of this luminaire can not be replaced. If the cable is damaged, the luminaire should be removed11. The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person

SPECIFICATIONS1. LED power is set in the factory 2. Light color standard 3000K/4000K3. CLO, Dimprofile is set in the factory

PARTS1. Luminaire with asymmetric optics2. TOP LID: 8718843016868 (RAL7040) 3. TOP SCREW: 8718843016936 (RAL7040) 4. LED module: article number oncord and on LED module5. DRIVER

9 kg

IP65IK09

Ø19

LW-FKLD TOOL871884302085816 Nm Torque

8718843017353 - LW-FKLD manual C1-C2 EN 1.3

Page 2: FRISO KRAMER DIRECT CLASS 1/II IMPORTANT SPECIFICATIONS€¦ · 40°C 0,22 FRISO KRAMER DIRECT CLASS 1/II Lightsource: LED Voltage: 230 V AC 50 Hz Power factor: > 0,90 Pole diameter:

INSTALLATION1

2

21 Hexbolt facing street*

1 2BROWN - L1

BLUE - NYELLOW-GREEN - G

ROADpoint road sticker towards street

3A

1 2BROWN - L1

BLUE - N

3B

INFORMATION TERMINAL BLOCK:1. 3 or 4 pins screw terminal2. Rated voltage and current: 250V / > 1A3. Complying with standard EN 60998-2-1 or EN 60998-2-2

8718843017353 - LW-FKLD manual C1-C2 EN 1.3

Page 3: FRISO KRAMER DIRECT CLASS 1/II IMPORTANT SPECIFICATIONS€¦ · 40°C 0,22 FRISO KRAMER DIRECT CLASS 1/II Lightsource: LED Voltage: 230 V AC 50 Hz Power factor: > 0,90 Pole diameter:

OPEN COVER1

Ø19

2

use cloth

8718843017353 - LW-FKLD manual C1-C2 EN 1.3

Page 4: FRISO KRAMER DIRECT CLASS 1/II IMPORTANT SPECIFICATIONS€¦ · 40°C 0,22 FRISO KRAMER DIRECT CLASS 1/II Lightsource: LED Voltage: 230 V AC 50 Hz Power factor: > 0,90 Pole diameter:

Chemicals that can outgas hydrocarbons (e.g., toluene, benzene, xylene)

Methyl acetate or ethyl acetate (e.g., nail polish remover)

Cyanoacrylates (e.g., “Superglue”)

Glycol ethers and dipropylene glycol monomethyl ether (e.g., electronics cleaners)

Formaldehyde or butadiene (e.g., PLIOBOND® adhesive)

Chlorine, including bleach-containing cleaners and sprays

Table 1: Common chemicals with known LED compatibility issues

Base Material TypeOK In XLamp

Designs*Outgas Tested

Issues Found

Issues Suspected

Acetic acid Acid Yes

Acrylic rubber Rubber/plastic seal Yes

Acetone Manufacturing material Yes

Ammonia Alkaline Yes

Benzene Solvent Yes

Butadiene rubber Rubber/plastic seal Yes

Butyl rubber Rubber/plastic seal Yes

Chlorinated polyethylene Rubber/plastic seal Yes

Chlorobutyl Rubber/plastic seal Yes

Chlorosulphonated rubber Rubber/plastic seal Yes

Cyanoacrylate Sealant & adhesive Yes Yes

Dichloromethane Solvent Yes

Epichlorhydrin Rubber/plastic seal Yes

Gasoline Solvent Yes

Halogenated hydrocarbons (containing F, Cl, Br elements)/miscellaneous Yes Yes

Hydrochloric acid Acid Yes

MEK (methyl ethyl ketone) Solvent Yes

MIBK (methyl isobutyl ketone) Solvent Yes

Mineral spirits Solvent Yes

Nitric acid Acid Yes

Petroleum Oil/lubricant Yes

Potassium hydroxide Alkaline Yes

Silicone oil Oil/lubricant Yes

Sodium hydroxide Alkaline Yes

Sulfuric acid Acid Yes

Tetracholoromethane Solvent Yes

Tetradecylamine Yes

Toluene Solvent Yes

Trimethylhexamethylene diamine Yes

Xylene Solvent Yes

Table 5: Base material compatibility

CLEANING THE LUMINAIREThe detergents in the table below are discouraged. Use of these detergents may cause damage to the LEDs over time.

8718843017353 - LW-FKLD manual C1-C2 EN 1.3

Page 5: FRISO KRAMER DIRECT CLASS 1/II IMPORTANT SPECIFICATIONS€¦ · 40°C 0,22 FRISO KRAMER DIRECT CLASS 1/II Lightsource: LED Voltage: 230 V AC 50 Hz Power factor: > 0,90 Pole diameter:

CLOSE COVER1

use cloth

!! close with 16 Nm !!

16 Nm Torque

8718843017353 - LW-FKLD manual C1-C2 EN 1.3