Friction and syneresis in agar plates - ESPCI Paris...Friction and syneresis in agar plates Bosi MAO...
Transcript of Friction and syneresis in agar plates - ESPCI Paris...Friction and syneresis in agar plates Bosi MAO...
![Page 1: Friction and syneresis in agar plates - ESPCI Paris...Friction and syneresis in agar plates Bosi MAO (毛 博思) Centre de Recherche Paul Pascal, 115 av. Dr. Schweitzer 33600 Pessac](https://reader031.fdocuments.us/reader031/viewer/2022040105/5e3ee998af172b00e04315fd/html5/thumbnails/1.jpg)
Friction and syneresis in agar plates Bosi MAO (毛 博思)
Centre de Recherche Paul Pascal,
115 av. Dr. Schweitzer 33600 Pessac
Thesis Advisors: Patrick Snabre & Thibaut Divoux 1
Workshop on adhesion/friction of soft materials. ESPCI – September 29th 2014
![Page 2: Friction and syneresis in agar plates - ESPCI Paris...Friction and syneresis in agar plates Bosi MAO (毛 博思) Centre de Recherche Paul Pascal, 115 av. Dr. Schweitzer 33600 Pessac](https://reader031.fdocuments.us/reader031/viewer/2022040105/5e3ee998af172b00e04315fd/html5/thumbnails/2.jpg)
Agar plates & Syneresis
… are subject to Syneresis
2
Mainly composed of water (>95%!)
+ 1 to 4 % agarose & agaropectin (polysaccharides)
+ small amount of amino-acid, surfactants, etc.
Agar plate…
“spontaneous or stress-induced shrinkage of the gel matrix and expulsion of solvent”
→ delayed detachment of the gel
Water evaporation
Gel shrinkage
t=0 h
t=15 h
Matsuhashi, Agar in Food Gel, P. Harris Ed. (1990)
Commercial Plate
![Page 3: Friction and syneresis in agar plates - ESPCI Paris...Friction and syneresis in agar plates Bosi MAO (毛 博思) Centre de Recherche Paul Pascal, 115 av. Dr. Schweitzer 33600 Pessac](https://reader031.fdocuments.us/reader031/viewer/2022040105/5e3ee998af172b00e04315fd/html5/thumbnails/3.jpg)
“Delayed detachment” of the gel from the Petri dish
Main goals of the project:
rationalize the delayed detachment
monitor the shrinkage dynamics for different boundary conditions
impact of the gel’s microstructure on the dynamics
3
![Page 4: Friction and syneresis in agar plates - ESPCI Paris...Friction and syneresis in agar plates Bosi MAO (毛 博思) Centre de Recherche Paul Pascal, 115 av. Dr. Schweitzer 33600 Pessac](https://reader031.fdocuments.us/reader031/viewer/2022040105/5e3ee998af172b00e04315fd/html5/thumbnails/4.jpg)
3. Diffusing-Wave Spectroscopy (DWS)
1. Rheology
time Spatio-temporal diagram 2. Interferometry
4
Techniques overview
Adhesion related issue
![Page 5: Friction and syneresis in agar plates - ESPCI Paris...Friction and syneresis in agar plates Bosi MAO (毛 博思) Centre de Recherche Paul Pascal, 115 av. Dr. Schweitzer 33600 Pessac](https://reader031.fdocuments.us/reader031/viewer/2022040105/5e3ee998af172b00e04315fd/html5/thumbnails/5.jpg)
5
How to monitor the gel formation?
Agar (Sigma Aldrich® or
BioMérieux®)
Agar solution (1.5% wt)
100°C 80°C
Gel preparation
Plate-Plate geometry (Ø 40mm)
Gap 500mm
Agarose (0.25 wt%) – 1°C/min
CP50mm g=0.5%, w=10rad.s-1
Mohammed et al., Carbohyd. Polym. 36, 15 (1998)
Formation of an interconnected network made of double helices
Rees et al., Angew. Chem. Int. Edit 15, 214 (1977) San Biagio et al., Food Hydrocolloid 10, 91 (1996)
![Page 6: Friction and syneresis in agar plates - ESPCI Paris...Friction and syneresis in agar plates Bosi MAO (毛 博思) Centre de Recherche Paul Pascal, 115 av. Dr. Schweitzer 33600 Pessac](https://reader031.fdocuments.us/reader031/viewer/2022040105/5e3ee998af172b00e04315fd/html5/thumbnails/6.jpg)
-1°C/min
g=0,01% - w=1Hz
The gel is losing contact with the plate during its formation
Gap increases as the
temperature decreases
6
An unexpected adhesion issue!
+ Isothermal regime Temperature ramp 70°C->20°C Protocol :
![Page 7: Friction and syneresis in agar plates - ESPCI Paris...Friction and syneresis in agar plates Bosi MAO (毛 博思) Centre de Recherche Paul Pascal, 115 av. Dr. Schweitzer 33600 Pessac](https://reader031.fdocuments.us/reader031/viewer/2022040105/5e3ee998af172b00e04315fd/html5/thumbnails/7.jpg)
-1°C/min
g=0,01% - w=1Hz
7
An unexpected adhesion issue!
Temperature compensation is not enough – no steady state regime
Temperature compensation + .
+ Isothermal regime Temperature ramp 70°C->20°C Protocol :
![Page 8: Friction and syneresis in agar plates - ESPCI Paris...Friction and syneresis in agar plates Bosi MAO (毛 博思) Centre de Recherche Paul Pascal, 115 av. Dr. Schweitzer 33600 Pessac](https://reader031.fdocuments.us/reader031/viewer/2022040105/5e3ee998af172b00e04315fd/html5/thumbnails/8.jpg)
8
A proper protocol to monitor the gel formation
-1°C/min
g=0,01% - w=1Hz
Outlooks: study the influence of several other parameters:
Temperature drop, cooling rate, agar concentration, etc.
+ Isothermal regime Temperature ramp 70°C->20°C Protocol :
Temperature compensation + .
Constant axial force + .
![Page 9: Friction and syneresis in agar plates - ESPCI Paris...Friction and syneresis in agar plates Bosi MAO (毛 博思) Centre de Recherche Paul Pascal, 115 av. Dr. Schweitzer 33600 Pessac](https://reader031.fdocuments.us/reader031/viewer/2022040105/5e3ee998af172b00e04315fd/html5/thumbnails/9.jpg)
-1°C/min
g=0,01% - w=1Hz
9
The protocol needs to be adapted to the gel…
The strain amplitude should be adapted to the agar concentration!
Stress-induced syneresis
Normand et al., Biomacromolecules 1, 730 (2000)
+ Isothermal regime Temperature ramp 70°C->20°C Protocol :
Temperature compensation + .
Constant axial force + .
![Page 10: Friction and syneresis in agar plates - ESPCI Paris...Friction and syneresis in agar plates Bosi MAO (毛 博思) Centre de Recherche Paul Pascal, 115 av. Dr. Schweitzer 33600 Pessac](https://reader031.fdocuments.us/reader031/viewer/2022040105/5e3ee998af172b00e04315fd/html5/thumbnails/10.jpg)
10
The adhesion between the gel and the plate is a serious issue
Measuring G’ & G” requires temperature compensation & normal force control
Our work urges to revisit some results from the literature…
Take home messages & outlooks
Grillet et al., Rheology, Vicente(Ed.), 59 (2012)
Norman et al., Carbohydrate Polymers 54, 83 (2003)
Labropoulos et al., Carbohydrate Polymers 50, 407 (2002)
Plate-Plate geometry,
Gap 25mm,
g=0,01% - w=1Hz
Double concentric
cylinders, gap 3mm,
g=0,2%
s=5Pa - w=1Hz
![Page 11: Friction and syneresis in agar plates - ESPCI Paris...Friction and syneresis in agar plates Bosi MAO (毛 博思) Centre de Recherche Paul Pascal, 115 av. Dr. Schweitzer 33600 Pessac](https://reader031.fdocuments.us/reader031/viewer/2022040105/5e3ee998af172b00e04315fd/html5/thumbnails/11.jpg)
Thank you !
11