Product Specification
Time and Temperature Parameters
Programmable by user
Records Stored on secure customer website
Formats The archive can be viewed in a variety of
chart, map, and spreadsheet formats; with zoom capability.
Access Secure, password-protected access
1-40-1000-001 Client Site Access – Data Collection, Alerts, Reports
All data from FreshLoc monitoring is stored in the FreshLoc Cloud and continuously monitor for compliance. When temperatures move out of a pre-set range, FreshLoc Alerts are sent via pager, text message, or email. The parameters for these alerts are customizable to client needs. User-defined time and temperature set points determine when an alert is sent, the number of alerts sent, and how the urgency of the issue is escalated. Monitoring is automatic and continuous for all sensors in the system. Measurements are taken twice a minute, and data is backed up at the customer site on each sensor and stored indefinitely in the FreshLoc Cloud. Time and temperature reports from each sensor are emailed on a defined schedule or displayed on an as- needed basis on a workstation or mobile device.
Features Easy to Manage—The user interface for configuration of alerting and monitoring is clear and easy to understand.
Reliable 24/7 Coverage—Alerts from FreshLoc give users peace of mind—at work, at home, and on the road.
Audit Reports—Continuous monitoring creates an archive of regularly scheduled reports—hourly, daily, weekly, or on any other schedule the user requires. Corrective Actions are easy to log from mobile devices or desktop browser.
Data Fits Standard Applications—Reports can be printed in several formats, or downloaded and used in standard spreadsheet applications. There are more than 30 reports styles.
Digital Alerts Monitoring and Recording
Format Available in digital format to
cell phones, pagers, email and screen pop-up.
Timing User configurable
Escalation If unanswered, alerts escalate to other devices and/or users.
Specifications subject to change at the discretion of FreshLoc Technologies.
FreshLoc Technologies – 15443 Knoll Trail # 200 – Dallas, Texas 75248 972-759-0111 www.freshloc.com
Product Specification
Functional Description
Transmit the environmental measurements from FreshLoc Sensors/Loggers to the FreshLoc
Cloud. Power
Requirements 12 Volts DC, 110 VAC
Physical Dimensions 3.75” x 2.75” x 1.00” (9.53 x 6.9 x 2.5 cm)
Weight 8 oz (227 g)
Protocol Proprietary 900MHz Wi-Fi IEEE 802.11n
Ethernet IEEE 802.3 10/100 Base-T
1-30-6000-001 FreshNet Reader
FreshNetTM Readers are multi-mode devices unique in that they have three levels of functionality: Ethernet Gateway Reader, Wi-Fi Reader, or an Auto-Extender Mesh Reader. They self-configure as either a gateway or extender. Readers aggregate data from the 900 MHz environmental sensor network and pass it to secure servers in the FreshLoc Cloud via the client’s network infrastructure. FreshNetTM Readers extend the range of Ethernet Gateway connections by using an ultra-secure meshing scheme that interconnects all Readers within range. They are self-forming and self healing as they extend blanket-like coverage. The entire system is designed for reliability and meets hospital standards for security and consistent operation.
Features Easy Installation—FreshNetTM Readers are plug-and-play and have a self-forming, self-healing mesh that requires no configuration. In a FreshNet network, multiple gateways coupled with Auto Extender Readers provide remarkable redundancy and fault tolerance.
Compliant—The Readers are compliant with FCC/IC/CE and hospital standards. FreshLoc communications from its wireless temperature sensors to the reader is in the 900 MHz FM band and is designed to be non-interfering with other technologies found in hospitals. No PC or Server Required- FreshNetTM Readers eliminate the need for any PC or server because they can be configured to pass data directly to the secure Cloud where all data is managed and archived. There is no need for additional IT resources at your facility.
Long Range – The readers can receive data from sensors hundreds of feet away facilitating site planning and deployment. Broad Coverage – FreshNetTM Readers facilitate the expansion of coverage area as each new reader interconnects and extends the range of all other readers. FreshNetTM is a wireless, proprietary access network whose Auto Extender nodes and access is known only to other FreshNetTM nodes. FreshNetTM is designed to be highly robust but to use small fast packets for minimal use of the wireless signaling space.
Technical Specifications1
Minimum Range Omni directional - Typically 100 to 150 feet Reader to
Reader
Operating Temperature 32˚F (0˚C) to 122˚F (50˚C)
WPA Encrypted SSID 128-bit and 256-bit TKIP/CCMP (AES) encryption
Output Power 400mW
Frequency 914-918 MHz 2.4 GHz
1 Specifications subject to change at the discretion of Freshloc Technologies.
FreshLoc Technologies – 15443 Knoll Trail # 200 – Dallas, Texas 75248 972-759-0111 www.freshloc.com
Product Specification
FreshLoc Technologies – 15443 Knoll Trail # 200 – Dallas, Texas 75248 972-759-0111 www.freshloc.com
1-30-6000-001 FreshNet Reader Page 2
Sensory Network Technical Specifications
Typical Range indoors Omni-directional 250’ -300’ line-of-sight. Range may be reduced
by obstructions. Function
Transmit the environmental measurements from FreshLoc Sensors/Loggers to the FreshLoc Cloud.
Operating Temperature Range
32˚F (0˚C) to 122˚F (50˚C) Physical
Dimensions 3.75” x 2.75” x 1.00” (9.53 cm x 6.9 cm x 2.5 cm)
Frequency and Transmit power
Proprietary spread spectrum 902-928 MHz (typically 914-918
MHz) under 1 mille watt. Weight 8 oz (227g)
Power Requirement 12 volts DC, 110 vac Connections Ethernet: RJ45
Power jack for transformer
Gateway Network Interface – Wired Technical Specifications
Function Establish a gateway connection through the Enterprise network
Standard IEEE 802.3
Physical Layer 10/100Base-T
Data Rate 10/100 Mbps (auto-sensing)
Mode Full or half-duplex (autosensing)
Connector RJ-45
Identification Integrated Ethernet MAC/PHY
POE Power Pass-Through 12-18v (non-802.3af) (optional)
Auto-Extending Network Interface – Wireless Technical Specifications1
Standard IEEE 802.11n
Extension Range Omni directional - Typically 100 to 150 feet AER to AER
Frequency 2.4 GHz
Data Rate Up to 11 Mbps with automatic fallback
Modulation CCK (5.5 Mbps)
Typical Transmit Power MCS0: 400mw (26dBm) MCS7: 125mw (21dBm)
Receive Sensitivity MCS0: -95dBm MCS7:-73dBm
WPA Encrypted SSID 128-bit TKIP/CCMP (AES) encryption
_____________________________
Specifications subject to change at the discretion of FreshLoc Technologies.
Product Specification
FreshLoc Technologies – 15443 Knoll Trail # 200 – Dallas, Texas 75248 972-759-0111 www.freshloc.com
1-20-1000-003 Temperature Logger Internal – Room Temperature
FreshLoc® Ambient Sensors are miniature devices with a
unique RFID serial number. They accurately measure
temperature and continually send information to the
FreshLoc® system. The sensors are Loggers and save up to 83
hours of data on the sensor in case of building power failure
or network outage.
Features Easy Installation—The sensors are wireless, can be placed most anywhere, and are secured easily with adhesive strips, hanging clips, or hooks. In most cases, installation can be completed without disrupting normal business operations.
Long Range—Signals from the sensors can be received up to 300 feet line-of-sight; within a building, the range is typically 150 feet. Obstructions such as walls and floors may reduce effective range.
Population—Hundreds of sensors can be placed within a range without interference from one another or loss of identification.
Supervision—Sensors continuously transmit packets of data. Transmissions of Current temperature readings alternate with transmissions of stored logs each minute. A completed temperature message is recorded approximately every two minutes.
Accurate—Temperature is accurate to within 1 Degree F.
Sensor Type Thermistor (NIST traceable)
Temperature Operating Range
-30˚F (-34˚C) to 176˚F (80˚C) Function Measures and logs the ambient temperature of its
environment and transmit its information to a FreshLoc® Reader 24/7.
Temperature Measurement Range
-40˚F (-40˚C) to 250˚F (121˚C) Physical
Dimensions 3.2” x 2.4” x 0.6” (8.1 cm x 6.1 cm x 1.5 cm)
Temperature Accuracy ±1˚F (±0.55˚C) Address
Capability 64 bit
Temperature Resolution
0.11˚F (0.06˚C) Weight 1.5 oz (42g)
Output Power <1 mW Protocol Proprietary
Frequency 902-928 MHz Sensing Cable
Dimension Internal.
Specifications subject to change at the discretion of FreshLoc Technologies.
Product Specification
FreshLoc Technologies – 15443 Knoll Trail # 200 – Dallas, Texas 75248 972-759-0111 www.freshloc.com
1-20-1000-007 Temperature Logger 18" External Probe
1-20-1000-013 Temperature Logger 36" External Probe
FreshLoc® Extended Probe Sensors are miniature devices with
a unique RFID serial number. They accurately measure
temperature and continually send information to the
FreshLoc® system. The sensors are Loggers and save up to 83
hours of data on the sensor in case of building power failure or
network outage. Probes are available in 18” or 36” lengths.
Custom lengths are available upon request. This model can be
used as an ambient probe or in fluid.
Features Easy Installation—The sensors are wireless, can be placed most anywhere, and are secured easily with adhesive strips, hanging clips, or hooks. In most cases, installation can be completed without disrupting normal business operations.
Long Range—Signals from the sensors can be received up to 300 feet line-of-sight; within a building, the range is typically 150 feet. Obstructions such as walls and floors may reduce effective range.
Population—Hundreds of sensors can be placed within a range without interference from one another or loss of identification.
Supervision—Sensors continuously transmit packets of data. Transmissions of Current temperature readings alternate with transmissions of stored logs each minute. A completed temperature message is recorded approximately every two minutes.
Accurate—Temperature is accurate to within 1 Degree F.
Sensor Type Thermistor (NIST traceable)
Temperature Operating Range
-30˚F (-34˚C) to 176˚F (80˚C) Function Measures and logs the ambient temperature of its
environment and transmit its information to a FreshLoc® Reader 24/7.
Temperature Measurement Range
-40˚F (-40˚C) to 250˚F (121˚C) Physical
Dimensions 3.2” x 2.4” x 0.6” (8.1 cm x 6.1 cm x 1.5 cm)
Temperature Accuracy ±1˚F (±0.55˚C) Address
Capability 64 bit
Temperature Resolution
0.11˚F (0.06˚C) Weight 1.5 oz (42g)
Output Power <1 mW Protocol Proprietary
Frequency 902-928 MHz Sensing Cable
Dimension 18” (45.72 cm) wire with 3/8” probe. 36” (91.44 cm) wire with 3/8” probe.
Specifications subject to change at the discretion of FreshLoc Technologies.
Product Specification
FreshLoc Technologies – 15443 Knoll Trail # 200 – Dallas, Texas 75248 972-759-0111 www.freshloc.com
1-20-1700-080 Humidity Logger
The FreshLoc® Humidity Logger accurately measures and records
humidity, making records for both critical storage factors
available instantly. The Humidity logger stores up to 83 hours of
data that is automatically replayed and recorded in the event of
a power failure. Relative humidity is accurate to within 2
percentage points. Rugged and reliable, the sensor’s long-term
stability is excellent.
Features Easy Installation—The sensors are wireless, can be placed most anywhere, and are secured easily with adhesive strips, hanging clips, or hooks. In most cases, installation can be completed without disrupting normal business operations.
Long Range—Signals from the sensors can be received up to 300 feet line-of-sight; within a building, the range is typically 150 feet. Obstructions such as walls and floors may reduce effective range.
Population—Hundreds of sensors can be placed within a range without interference from one another or loss of identification.
Supervision—Sensors continuously transmit packets of data. Transmissions of Current humidity readings alternate with transmissions of stored logs each minute. A completed humidity measurement is recorded approximately every two minutes.
Accurate— Relative Humidity is accurate to within 2 percentage points.
Frequency 902-928 MHz
Temperature Operating
Range -30˚F (-34˚C) to 176˚F (80˚C) Sensor Type Digital Capacitive/Band-Gap
Humidity Accuracy
±2.0 percent (between 10-90%)
Function Measures and logs the humidity of its environment and transmit its serial information to a FreshLoc® Reader™
24/7.
Humidity Resolution
±.06% Physical
Dimensions 3.2” x 2.4: x0.6” (8.1 cm x 6.1 cm x 1.5 cm)
18” External Probe
Output Power
<1 mW Address
Capability 64 Bit
Protocol Proprietary Weight 1.5 ounces (42g)
Specifications subject to change at the discretion of FreshLoc Technologies.
Product Specification
FreshLoc Technologies – 15443 Knoll Trail # 200 – Dallas, Texas 75248 972-759-0111 www.freshloc.com
1-20-2500-001 Pressure Sensor
The FreshLoc® Pressure Sensor measures the positive or negative
pressure differential that exists between two adjacent areas. It is
ideal for use in Pharmacy Compounding Areas, Clean Rooms,
ICUs, Vent Hoods and other areas where pressure differential is
critical to safety and quality.
Features Easy Installation—The sensor mounts to the wall with two screws. It can be used to detect either positive or negative pressure depending on the mounting location. Two flexible tubes are supplied that can attach to a portal that penetrates the wall between measurement areas.
Long Range—Signals from the sensors can be received up to 300 feet line-of-sight; within a building, the range is typically 150 feet. Obstructions such as walls and floors may reduce effective range.
Population—Hundreds of sensors can be placed within a range without interference from one another or loss of identification.
Supervision—Sensors continuously transmit packets of data. Transmissions of current readings alternate with transmissions of stored logs each minute. A completed pressure reading is recorded approximately every two minutes.
Accuracy – Measurements are accurate to plus or minus .2 Pascal.
Frequency 902-928 MHz
Temperature Operating Range
-30˚F (-34˚C) to 180˚F (82˚C) Sensor Type Thermal Silicon Flow Through
Pressure Measurement
Range
-500 Pa (-2 In H20) to 500 Pa (2 In H20)
Function Measures differential pressure and transmit its
information to a FreshLoc® Reader 24/7.
Measurement Accuracy
±3% of Reading Physical
Dimensions 5.4” x 3.1” x 1.3” (13.6 cm x 6.7 cm x 3.2 cm)
Zero Point Accuracy ±0.2 Pascal Address
Capability 64 bit
Zero Point Repeatability
0.1 Pascal Weight 1.5 oz (42g)
Output Power <1 mW Protocol Proprietary
Specifications subject to change at the discretion of FreshLoc Technologies.
Product Specification
Logger Type Type T Thermocouple
Function Measures the temperature of its environment
and transmit its information to a FreshLoc® Reader 24/7.
Physical Dimensions 1.0” x .835” (4.064 cm x 2.121 cm)
Address Capability 64 bit
Weight 1.2 ounces
Protocol Proprietary Sensing Cable
Dimension 6’ (1.8m)
1-20-1700-090 Thermocouple Logger
The FreshLoc® Thermocouple Logger measures temperatures ranging from -200˚ to 200˚C. Ideal for critical applications in lab and research environments, the sensor’s wide range accurately tracks subzero temperatures in critical freezers containing vital perishables, such as stem cells and bone marrow. The Logger saves up to 83 hours of data.
Features Easy Installation—The sensors are wireless, can be placed most anywhere, and are secured easily with adhesive strips, hanging clips, or hooks. In most cases, installation can be completed without disrupting normal business operations. Long Range—Signals from the sensors can be received up to 300 feet line-of-sight; within a building, the range is typically 150 feet. Obstructions such as walls and floors may reduce effective range. Population—Hundreds of sensors can be placed within a range without interference from one another or loss of identification. Supervision—Sensors continuously transmit packets of data. Transmissions of Current temperature readings alternate with transmissions of stored logs each minute. A completed temperature message is recorded approximately every two minutes. Accurate—Temperature is accurate to within 1 Degree F.
Temperature Operating Range -30˚F (-34˚C ) to 180˚F (80˚C)
Temperature Measurement Range -328˚F (-200˚C) to 392˚F (200˚C)
Temperature Accuracy ±3.6˚F (±2.0˚C)
Temperature Resolution 0.11˚F (0.06˚C)
Output Power <1 mW
Frequency 902-928 MHz
Specifications subject to change at the discretion of FreshLoc Technologies.
FreshLoc Technologies – 15443 Knoll Trail # 200 – Dallas, Texas 75248 972-759-0111 www.freshloc.com
Product Specification
SensorType Laser Particle Counter
Function Measures 0.5 and 2.5 Micron particles and
transmits the information to a FreshLoc Reader 24/7
Physical Dimensions
7.5" x 5.0" x 3.5" (19.1 cm x12.7 cm x 8.9 cm)Excluding external antenna
Weight 13.9 oz (395g)
Protocol Mesh Network or Wi-Fi
IEEE 802.11n
1-20-2600-050 Particle Counter
FreshLoc Technologies introduces our FreshLoc Particle Counter. The latest sensor to be added to the FreshLoc product line is perfect for measuring air quality in process controlled environments. The sensor is capable of measuring particles per cubic foot of air in the 0.5 and 2.5 Micron range and alerting personnel of the need to service air handling equipment. The Freshloc web interface also allows for monitoring the sensor for real time and historical data, providing 24/7 monitoring, alerting and compliance reporting.
Features Easy Installation—The sensors are wireless and can be placed most anywhere.
Long Range—Signals from the sensors can be received up to 1000 feet line-of-sight; within a building, the range is typically 250-300 feet. Obstructions such as walls and floors may reduce effective range. Extended range can be accomplished with the use of Mesh Network Readers.
Population—Hundreds of sensors can be placed within a range without interference from one another or loss of identification.
Supervision— A completed large and small particle count is received approximately every two minutes.
Operating Temperature Range -30˚F (-34˚C ) to 180˚F (8 2˚C)
Particle Measurement Range
Particles per cubic foot in the 0.5 and 2.5 Micron
Range
Output Power 400mW
Specifications subject to change at the discretion of FreshLoc Technologies.US Patent 8009290; Foreign Patent Pending
FreshLoc Technologies – 15443 Knoll Trail # 200 – Dallas, Texas 75248 972-759-0111 www.freshloc.com
Frequency 2.4 GHz