freewave tech 6page - Security Warehouse
Transcript of freewave tech 6page - Security Warehouse
I n s t a l l a t i o n & U s e r F r i e n d l y
E x t e n s i v e R a n g e o f A d d - o n s
M o r e T h a n J u s t S e c u r i t y
INNOVATIVE SOLUTIONSw w w. c q r. c o . u k
CQR |
home appliances remote control
built-in intelligent GSM communicator
internet connection using GPRS
telephone calls via GSM
SMS terminal
monitoring station
wirefree internal sounders& interface modules
32 wirefree detectors
8 wirefree remote controls or keypads
wirefree external sounder
4 wired bus keypads
4 hard-wire zones
O R I O N E X T E R N A L S I R E NG S M S Y S T E M
PgXprogrammable outputs
wirefree internal sounders& interface modules
PgY
4 wired bus keypads
4 hard-wire zones
ComLink
32 wirefree detectors
voice messages
monitoring station
remote access
8 wirefree remote controls or keypads
wirefree external sounder
S TA N D A R D S Y S T E M
The Digital signal processing used in this PIR ensures a highimmunity to false alarms and outstanding stability. The useof a sophisticated radio communication protocol alsoensures a high level of data security. The detector performsregular auto testing and reports its condition to the controlpanel for full supervision. Built-in tamper switches provideprotection against cover and wall removal.
P A S S I V E I N F R A R E D D E T E C T O R F W / J A 6 0 P
The acoustic break glass detector provides easy and reliableprotection, 1 sensor will cover an entire room (9 meters)regardless of the number of windows. A dual technologydetection method (air pressure and sound analysis)combined with digital processing is used to guarantee highsensitivity to the breaking of glass. The detector is alsoprotected against tampering
B R E A K G L A S S D E T E C T O R F W / J A 6 0 B
a) Chime/audible indicator b) Door bell
FW/JA60P
FW/JA60N
FW/JA60E
FW/JA63KRXUK
FW/JA60NFW/RC40
FW/RC28
FW/RC28
FW/RC22
FW/RC22
FW/UC260FW/UC260
I N T E R N A L S O U N D E R C O M M O N A P P L I C AT I O N
The universal contact has 2 built-in reed switches toaccommodate either left or right handLled doors, there arealso 2 inputs for an external sensor (alarm/tamper). The useof a sophisticated radio communication protocol alsoensures a high level of data security. The universal contactperforms regular auto testing and reports its condition tothe control panel for full supervision. Built-in tamperswitches provide protection against cover and wall removal.
U N I V E R S A L C O N TA C T F W / J A 6 0 N
The FW/JA60SR is a wirefree battery operated unit, whichcan be enrolled to a FW/JA63 control panel. It has a built-insounder to warn people in the immediate vicinity, it can alsobe tested either by using the test button or any infraredremote control
I O N I C S M O K E D E T E C T O R F W / J A 6 0 S R
The external sounder is powered from its own local ACadapter and has a built-in battery backup; it communicateswirefree to a FW/JA63 control panel, with 2-waycommunications. The siren performs regular self-testing andreports its condition to the control panel for full supervision.The sounder is protected against cover and wall removal.The 4 blue high visibility LEDs flash changing to 1 flash persecond when in an alarm condition, acting as a visualindication of an alarm.
E X T E R N A L S O U N D E R F W / J A 6 0 A
Power 2 x 1.5V AAA batteriesBattery Life Typical 1 year
Detection Method Dual element with digitalsignal processing
Coverage 12m 120°Optional Lens Standard, long corridor, pet zoneLED indication Tesing and low batteryOperating Frequency 433 MHzWorking Range Max 100mComplies With EN 50131-1 grade 2Dimensions 70 x 90 x 65mm
Power 2 x 1.5V AAA batteriesBattery Life Typical 1 yearDetection Method Magnetic Reed SwitchExternal Sensor Inputs Alarm and tamper (EOL)LED indication Testing and low batteryOperating Frequency 433 MHzWorking Range Max 100mComplies With EN 50131-1grade 2Dimensions 110x30x 27mm + antenna40mm
Power 2 x 1.5V AAA batteriesBattery Life Typical 1 yearSensor Dual technology acoustic sensorLED indication Testing and low batteryWorking Distance Max 9 metersOperating Frequency 433 MHzWorking Range Max 100mComplies With EN 50131-1grade 2Dimensions 55x 75x 22mm + antenna 40mm
Power 2 x 1.5V AA batteriesDeetction Method Ionic Chamber (max 4 kBq.)Built-in siren 94dB(A)@1mLED indication Self testing every 60 secondsCoverage 50m2
Alarm output Wirefree 433 MHzWorking Range Max 100mDimensions ø 120x 40mm
Power 230 VACBackup battery 6V 1.2Ah includedBattery Life Time Up to 5 yearsSiren Piezoelectric 118dB(A)Siren timer Set by control panelLED light timer 60 minutesOperating Frequency 433MHzWorking Range Max 100mComplies With EN50131-1 grade 2
This internal sounder plugs into any standard UK 3 pinsocket. It can be enrolled to a FW/JA63 control panel to giveentry/exit tones and alarm tones, any FW/JA60 detectorsenrolled will act as a chime zone. You can also enrol any ofthe FW/RC controls, to act as a doorbell you may also select1 of 8 melodies to be assigned to a controller or detector
I N T E R N A L S O U N D E R F W / U S 2 6 0 U K
Power 230 VACPower Consumption 1.5WSiren Mode 115 dB(A)Doorbell & Chime 8 melodies
Compatible DevicesFW/JA63 control panelFW/RCXX remote controlsFW/JA60 detector
Operating Frequency 433MHzWorking Range Max 40mDimensions 90x 65x 50mm + antenna 40mm
The FW/UC280 is an 8 zone interface linking FW/JA60detectors to any hard wired control panel, it can also sendtrigger signals to a FW/JA60A wirefree external sounder andto a FW/UC222 receiver. Additionally it can receive signalsfrom any FW/RCxx remote controls.
8 Z O N E I N T E R F A C E F W / U C 2 8 0
Power 12 VDCPower Consumption Typ 50mA max 150mAZone OutputsZ1 -Z8 8 relays 50mA/50VZone Signals 3 relays (tamper,fault low battery)Operating Frequency 433 MHzWorking Range Max 100mComplies With EN50131-1 grade 2Dimensions 195 x 140x 45mm + antenna 155m
The gas detector detects all mixtures of air and combustiblegases (natural gas, methane. propane, butane, acetylene,GPL, hydrogen, etc). It has a built-in sounder to warm peoplein the immediate vicinity, and has a relay output to control amotorized valve.
G A S D E T E C T O R F W/ J A 6 0 G
Power 230 VACDetection Method Hot fibre sensorRelay Output 230V 5ASensitivity 2 levels 10 and 20% of LELBuit-in Sounder 64dB(A)Area covered 50m2
Operating Frequency 433MHzWorking Range Max 40mDimensions 100x 73x 39mm
This remote control is a single channel transmitter that isused especially with the FW/UC260UK internal sounder as awirefree doorbell; it can also be used with other FW/UC2xxreceivers.
D O O R B E L L P U S H F W / R C 2 8
Power 6 V battery (L1016)Battery Life Time Typical 1 yearOperating Frequency 433 MHzWorking Range Max 50mDimensions 80 x 28 x 15mm
The FW/UC222 is a 240VAC wirefree receiver. It can have upto 30 wirefree remote controls or detectors enrolled; its relayoutput can operates at 240VAC 6.3A. There are 4 differentmodes of operation, the receiver can be used for automaticlighting, operation of electrical items, access control etc.When used in conjunction with an FW/JA63xxx controlpanel, the output relay of the receiver can copy signals fromthe control panels outputs.
2 4 0 V A C I N T E R F A C E F W / U C 2 2 2
Power 240 VACPower Consumption Max 1.5 WOperating Frequency 433 MHzOperating Range 100m (30m for FW/RCXX)Peripherals 30x FW/JA60XX detectors or
FW/RCXX remote controlsOutput relay Max 6.3A/240VAC
Modes Short pulse (3 secs),long pulse(2min),latch,on/off
Dimensions 100x 73 x 25mm + antenna 86mm
a) Remote control b) Wirefree transmission from the control panel
outputPgX
FW/RC28
FW/JA60N
FW/RC22
FW/RC60
FW/RC40
FW/JA60E
FW/JA63KRXUK
FW/JA60PFW/UC222
30 remote controls or detectors
FW/UC222
2 4 0 V A C I N T E R F A C E C O M M O N A P P L I C AT I O N
This cable allows a computer to be connected to anFW/JA63 control panel. Using the Comlink software, you cansupervise the system, download events, Programme thesystem, view RF signal levels, etc.
P C C A B L E F W / P C 6 0 A
PC Connection COM serial portOperating System MS WindowsCable Length 1.5 m
This modem connects a PC or FW/JA6oE keypad remotely toa FW/JA63 system via a telephone line. From your PC, theprovided Comlink software allows you to remote superviseand programme the system and also view RF levels.
M O D E M F W / J A 6 0 U
Power 240 VACPower Consumption Max 1.5VCommunication Protocol Specially encryptedOperating System MS windowsPC Connection COM serial portDimensions 130 x 95 x 26mm
There are 2 versions of the keypad available, the FW/JA60F,which is a fully supervised wirefree keypad, and theFW/JA60E a 4 wired bus keypad. Both Keypads have a built-in tamper switch to indicate opening or removal from wall;they also check the number of attempts to enter a code. TheLED indicators, display and built-in buzzer indicate the system status; each keypad is also backlit.
The FW/JA60F performs regular auto testing and reports itscondition to the panel for full supervision. Being wirefree itcan help an installer to monitor the system functions whilewalk testing can also be used to programme the system. Forlonger working distances an external antenna (FW/AN-01)can be used.
The FW/JA60E can also be used to programme the system;it can also be used with the FW/JA60U modem to remotelyoperate the control panel
K E Y P A D S
This large size wirefree button can be used either as a silentpanic button or as an on off switch for a FW/JA63 controlpanel or FW/US2xx receiver. An LED confirms the pressing ofthe button.
2 C H A N N E L C O N T R O L L E R F W / R C 2 2
The 4 button remote control has 2 sets of buttons whichcan be used to set and unset a FW/JA63 control panel orto trigger a silent panic alarm. It can also be used tocontrol an FW/UC2xx receiver. The 4 buttons can belockout to prevent accidental operation by the user.
H A N D H E L D F O B F W / R C 4 0
The FW/JA63 range of wirefree control panels feature 16 wirefree zones and 4 hardwired zones and is fully programmable, the wirefree zones can be furtherexpanded by twining which, allows 2 detector to be programmed onto 1 zone. The system can be further expanded by adding a subsystem (4+16/32 zones); it canalso be split into 2 independent systems with 1 common area (partition). The panel processes data from all system parts checking the radio communication fortamper, low batteries and jamming. Programming of the system can be carried out via a wirefree keypad, a wired keypad or via a PC using Comlink software.
The FW/JA63KRX has a built-in dialler/communicator, the dialler can call up to 4 telephone numbers delivering either 1 of 2 x10 second messages or 120 secondmessage. The communicator can communicate to a central station in 1 of 7 formats (Ademco, Contact ID). It also enables remote access using Comlink software.
The FW/JA63KRG has a built-in GSM dialler, enabling it to send and receive text messages, communicate to a central station using contact ID, allows phone calls tobe made via an attached phone, enables remote control of the system either via GSM or landline. A PC can also be connected to the Internet via GPRS if enabled,using an attached QWERTY keypad text messages can be sent to other mobiles, the keypad also provides a phone book and caller ID. It is also possible to controlappliances in the home via text messages
O R I O N E X T E R N A L S I R E NP A N E L S
Power 6V battery (L1016)Battery Life Typical 1 yearOperating Frequency 433 MHzCoding Digital hoppingChannels 6Working Range Max 30m (open area)Dimensions 60 x 25 x 13 mm
Power 6V battery (L1016)Battery Life Typical 1 yearOperating Frequency 433 MHzCoding Digital hoppingChannels 6Operating Modes Panic /On-OffWorking Range Max 100mDimensions 80 x 80 x 15 mm
FW/JA63KRX FW/JA63KXGWirefree Zones 16 (twin 32)
Operating Frequency 433 MHz
Hardwired Zones 4 fully programmable zones (NC, EOL or double EOL resistor)
Zone Attributes Instant, delayed, panic, fire, tamper, next delayed
Partitions 2 + 1 common area
Keypads Max 8 remote controls, 4 hardwired keypads
OutputsAlarm relay 1A/60V.
Programmable outputs PgX & PgY (chime, fire, arm, panic, alarm, door, home, AC power failure). Siren output(12V/1A)
Events Memory 127 events with time and date stamp
Power 240 VAC built-in double insulated supply
Back-up Battery 12V 1.2 Ah supplied
Communications 2 voice messages, Central station (ARC), remote access SMS + Audible to 8 phones, 2 x central station via CSM orGPRS, remote access
Messages 2x10 secs or 1x20 secs voice sent to 4 phone numbers SMS includes installation & source name. time and date
Supported Formats Ademco, Telemax, Franklin, Radionics, Surguard,DTMF2300, Contact ID Contact ID
Operating Temperature -10°C - +40°C
Complies With EN50131-1 grade 2, ELSI EN 300 220, ETS 300 683, TBR-21
Dimensions 258 x 214 x 77m + antenna 160mm
FW/JA60F FW/JA60E
Power4 x 1.5V AAA batteriesor 12 VDC (battery lifetypical 1 year)
12 VDC (40 mA)
Communication
Wirefree frequency433 MHz,bidirectional, digitalhopping code, maxworking distance50m
4 core data bus, maxworking distance100m
Complies with EN 50131-1 grade 2
Dimensions 140 x 80 x 26mm + antenna 80mm
CQR Security
125 Pasture Road, Moreton, Wirral
United Kingdom, CH46 4TH
Tel: +44(0)151 606 1000
Fax: +44(0)151 606 1122
email: [email protected]
www.cqr.co.uk
A member of nnkgnkng
d i s t r i b u t e d b y:
Where necessary this antenna can be used to increase the range.
This electronic switch can replace a standard mechanicalwall switch. It is directly powered from the mains supply, bypressing the switch up or down it works as a standard lightswitch. At the same time a built-in receiver enables signalsfrom FW/RCxx remote controls and FW/JA60x detectors tooperate the switch. Therefore the lighting can be operatedautomatically by use of the detectors or remotely by uses ofthe remote controls.
W I R E F R E E E L E C T R O N I C S W I T C H F W / U C 2 3 0
A N T E N N A F W / A N 0 1 A
Frequency 430 - 450 MHzInstallation VerticalCable Length 1.6mOperating Temperature -10°C - + 40°C
Power 240 VACSwitch Output 23W - 30WWorking Frequency 433 MHzWorking Range 100m (max 30m with FW/RC40)Enrolled Transmitters Max 8
Operating ModesSwitch mode2 minutes pulseOver switching mode
Dimensions 80 x 80 x 40mm
DATA S H E E T S A LS O AVA I L A B L E :Internal sounders& speakers
Detection
External sounders
Emergency switches& accessories
Cable & door loops
Hydrosure - fall detection for swimming pools & ponds
Is used to Set and Unset a FW/JA63 control panel. It can beconnect to an external controller such as a door access orcard swipe system; it also provides tamper protection forthe external device. The two inputs can be used in differentmodes, the first mode: 1 input is used for Set the other forUnset, the second mode: the first input is used to Set/Unsetthe other copies its status to the control panel (Set/Unset).
2 C H A N N E L I N T E R F A C E F W / R C 6 0
Power 2 x 1.5V AAA batteriesBattery Life Typical 1 yearExternal Inputs 2 (EOL or NC Zones)Indication LED Testing and low batteryOperating Frequency 433 MHzWorking Range Max 100mComplies with EN50131-1 grade 2Dimensions 110x 30 x 27 mm + antenna40mm
a) Wireless corridor light switch
FW/UC230 FW/UC230FW/RC22 FW/RC22 FW/RC40
FW/RC22
FW/RC28FW/JA60P
FW/JA60N
b) Automatic light switch
W I R E F R E E E L E C T R O N I C S W I T C H C O M M O N A P P L I C AT I O N