FreeStyle Libre 2 Quick Start Guide · 2020. 7. 22. · XXX YYYY-MM-DD F r e S t yle Li b r e STEP...

2
CODE XXX CODE A b Sensor Pack | Envase d Customer Service | Atenci 1-855-632-865 XXXXXXXXXX XXX YYYY-MM-DD F r e e S ty l e L i b STEP 3 STEP 6 STEP 9 Get Ready Apply Sensor Prepare Sensor Applicator Wash site using a plain soap, dry, and then clean with alcohol wipe. Allow site to air dry before proceeding. Peel lid completely off Sensor Pack. Unscrew cap from Sensor Applicator. CAUTION: Sensor codes must match on Sensor Pack and Sensor Applicator or glucose readings will be incorrect. Refer to your User’s Manual for full System instructions and information. Touchscreen Home Button USB Port Sensor Pack Reader Place Sensor Applicator over site and push down firmly to apply Sensor. CAUTION: Do not push down on Sensor Applicator until placed over prepared site to prevent unintended results or injury. Make sure Sensor is secure. Discard used Sensor Applicator and Sensor Pack according to local regulations. Gently pull Sensor Applicator away from your body. Quick Start Guide for FreeStyle Libre 2 Reader STEP 1 STEP 4 STEP 7 STEP 2 STEP 5 STEP 8 Line up dark mark on Sensor Applicator with dark mark on Sensor Pack. On a hard surface, press down firmly on Sensor Applicator until it comes to a stop. Sensor Applicator is ready to apply Sensor. CAUTION: Sensor Applicator now contains a needle. Do not touch inside Sensor Applicator or put it back into Sensor Pack. Lift Sensor Applicator out of Sensor Pack. Lid Cap Sensor Sensor Applicator Codes on labels must match 1 Assemble and Apply Sensor to your body 2 Start new Sensor with Reader 3 Check your glucose whenever you want for up to 14 days Wait 60 minutes for start-up Select site on back of upper arm. Do not use other sites as these may result in inaccurate glucose readings. Note: Avoid scars, moles, stretch marks, lumps, and insulin injection sites. To prevent skin irritation, rotate sites between applications. Setup Overview 1 Assemble and Apply Sensor to the back of your upper arm FLASH GLUCOSE MONITORING SYSTEM

Transcript of FreeStyle Libre 2 Quick Start Guide · 2020. 7. 22. · XXX YYYY-MM-DD F r e S t yle Li b r e STEP...

  • CODE XXX

    CODE

    Abbott Diabetes Care Inc. 1360 South Loop Road, Alameda, CA

    94502

    ART36

    504 R

    ev. 1

    08/1

    5

    Sensor Pack | Envase del sensorCustomer Service | Atención al cliente:

    1-855-632-8658

    XXXXXXXXXXX

    XXX

    YYYY-MM-DD

    FreeStyle Libre

    STEP 3

    STEP 6

    STEP 9

    Get

    Rea

    dy

    Ap

    ply

    Sen

    sor

    Pre

    par

    e Se

    nso

    r A

    pp

    lica

    tor

    Wash site using a plain soap,dry, and then clean with alcoholwipe. Allow site to air dry beforeproceeding.

    Peel lid completely off Sensor Pack. Unscrew cap from Sensor Applicator.

    CAUTION: Sensor codes must match on Sensor Pack and Sensor Applicator or glucose readings will be incorrect.

    Refer to your User’s Manual for full System instructions and information.

    Touchscreen

    Home ButtonUSB Port

    Sensor Pack

    Reader

    Place Sensor Applicator over site and push down firmly to apply Sensor.

    CAUTION: Do not push down on Sensor Applicator until placed over prepared site to prevent unintended results or injury.

    Make sure Sensor is secure. Discard used Sensor Applicator and Sensor Pack according to local regulations.

    Gently pull Sensor Applicator away from your body.

    Quick Start Guide forFreeStyle Libre 2 Reader

    STEP 1

    STEP 4

    STEP 7

    STEP 2

    STEP 5

    STEP 8

    Line up dark mark on Sensor Applicator with dark mark on Sensor Pack. On a hard surface, press down firmly on Sensor Applicator until it comes to a stop.

    Sensor Applicator is ready to apply Sensor.

    CAUTION: Sensor Applicator now contains a needle. Do not touch inside Sensor Applicator or put it back into Sensor Pack.

    Lift Sensor Applicator out of Sensor Pack.

    Lid Cap

    Sensor

    SensorApplicator

    Codes on labels must match

    ● 1 Assemble and Apply Sensor to your body

    ● 2 Start new Sensor with Reader

    ● 3 Check your glucose whenever you want for up to 14 days

    Wait 60 minutes for start-up

    Select site on back of upper arm.Do not use other sites as these may result in inaccurate glucose readings.Note: Avoid scars, moles, stretch marks, lumps, and insulin injection sites. To prevent skin irritation, rotate sites between applications.

    Setup Overview

    ● 1 Assemble and Apply Sensor to the back of your upper arm

    FLASH GLUCOSE MONITORING SYSTEM4.5”

    4.5”

    4.5”

  • 350

    250

    150

    50

    82 mgdLGlucose

    Trend Arrow What it means

    Glucose rising quickly

    Glucose rising

    Glucose changing slowly

    Glucose falling

    Glucose falling quickly

    Glucose Going Low

    2pm 6pm 10pm

    Start NewSensor

    ReviewHistory

    No Active Sensor

    10:23pm

    OK

    Low Glucose Alarm

    High Glucose Alarm

    Signal Loss Alarm

    Change Alarm Settings

    Change Alarm Settings

    Alarm Settings

    Low Glucose 70 mg/dL

    High Glucose 240 mg/dL

    Signal Loss On

    OK

    minutes

    New SensorStarting Up

    60 Sensor can be used in:

    OK

    Do not take high doses of vitamin C (more than 500 mg per day). This may falsely raise your Sensor readings. Supplements like Airborne® or Emergen-C® have high doses of vitamin C. Read labeling for all supplements to determine vitamin C content.

    Important OK

    Low Glucose Alarm

    Dismiss Alarm & Check Glucose

    High Glucose Alarm

    Dismiss Alarm & Check Glucose

    Scan Sensor now?

    Signal Loss Alarm

    YesNo

    Alarms

    Sound & Vibration

    Time & Date

    Settings

    1 / 3CheckGlucose

    ReviewHistory

    Ends in 14 days

    10:23pm

    When any alarm is on, sound/vibration and signal status display on the Home Screen.

    Refer to User's Manual for additional symbols.

    Symbol What it means

    Sound and Vibration ON

    Sound and Vibration OFF

    Sensor communicating with Reader

    Sensor not communicating with ReaderCheckGlucose

    ReviewHistory

    Ends in 14 days

    10:23pm

    Press Home Button to turn on Reader.

    Note: If using Reader for the first time, follow the prompts to set date and time.

    Touch Start New Sensor.Hold Reader within 1.5 inches (4 cm) of Sensor to scan it.

    Press Home Button to go to Home Screen. Touch .

    Touch Alarms and then touch Change Alarm Settings.

    Select and set your alarms. Touch done to save.

    Review the important information on the screen. Sensor can be used to check your glucose after 60 minutes.

    Hold Reader within 1.5 inches (4 cm) of Sensor to scan it.

    Reader shows your glucose reading. This includes your Current Glucose, Glucose Trend Arrow, and Glucose Graph.

    Press Home Button to turn on Reader.

    If you have followed the instructions described in the User’s Manual and are still having difficulty setting up your System or if you are not sure about a message or reading, contact your health care professional.

    STEP 3

    STEP 3

    STEP 1

    STEP 1

    STEP 2

    STEP 2 STEP 3

    STEP 1 STEP 2

    Touch Dismiss Alarm & Check Glucose or press the Home Button to dismiss alarm and check your glucose.

    Touch No to dismiss alarm.Touch Yes or press the Home Button to dismiss alarm and scan the Sensor.

    Notifies you when glucose is below the level you set.

    Notifies you when Sensor is not communicating with Reader and that you are not getting Low or High Glucose Alarms.

    Notifies you when glucose is above the level you set.

    The Sensor automatically communicates with the Reader and can give you glucose alarms. Alarms are on by default. To change their settings or turn alarms off, follow these steps. IMPORTANT: Glucose alarms are an important safety feature. Please consult your health care professional before making changes.

    You must scan your Sensor to see your glucose reading.

    Current GlucoseGlucose from your latest scan

    Glucose GraphGraph of your current and

    stored glucose readings

    MessageTouch for more

    information

    The shape of the circle sensor unit, FreeStyle, Libre, and related brand marks are owned by Abbott. ©2019 Abbott ART40392-001 Rev. C 06/20

    Manufacturer

    Consult instructions for use

    ● 2 Start new Sensor with Reader

    ● 3 Check your glucose

    Using Alarms

    Setting Alarms

    4.5”