Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...
Transcript of Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...
![Page 1: Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...](https://reader031.fdocuments.us/reader031/viewer/2022012014/6159b1627a3408138d409a7a/html5/thumbnails/1.jpg)
NVIDIA GRID™ and Dassault Catia from Proof of Concept to Production April 5, 2016
Fred Devoir, Textron Mgr – IT Infrastructure
Chris Savage, Bell Helicopter Infrastructure Operations Mgr
![Page 2: Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...](https://reader031.fdocuments.us/reader031/viewer/2022012014/6159b1627a3408138d409a7a/html5/thumbnails/2.jpg)
Introductions
2
Fred Devoir Manager – IT Infrastructure & Sr. Architect TEXTRON Inc.
Chris Savage Infrastructure Operations Manager Bell Helicopter
![Page 3: Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...](https://reader031.fdocuments.us/reader031/viewer/2022012014/6159b1627a3408138d409a7a/html5/thumbnails/3.jpg)
Bell Helicopter – Case Study & Benefits
3
• Problem
– PLM Distributed architecture presents significant challenges to manufacturing engineering
– Replication of model data doesn’t account for designer changes that effect manufacturing because cached data is out of date.
• Solution
– Move PLM Data centralized only and serve out models with graphics accelerated VDI.
• Observations
– In general, 40% improvement in load times for large CAD/CAM models
• Benefits
– First time in history manufacturing quality engineers could do quality checks digitally at the supplier using VDI on tablets rather than paper printed CAD.
![Page 4: Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...](https://reader031.fdocuments.us/reader031/viewer/2022012014/6159b1627a3408138d409a7a/html5/thumbnails/4.jpg)
Physical workstation - Model Load Comparison
Local to Enovia Data (LAN <1ms) Remote to Enovia Data (WAN ~60ms)
4
![Page 5: Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...](https://reader031.fdocuments.us/reader031/viewer/2022012014/6159b1627a3408138d409a7a/html5/thumbnails/5.jpg)
Pilot gear to Full Production 300+ users
5
• POC: – OEM server evaluations (HCL) and functional testing
– Power/cooling concerns and density
• Pilot: – Deployment started August 2014, January 2015 Launch
– 16 GPU Servers
– 32 NVIDIA GRID K2 Cards
– Support for 120+ Catia Users.
• Production: – Deployed started January 2015, Q1 2016 Launch
– 54 GPU Servers
– 108 NVIDIA GRID K2 Cards
– Support for 300+ Catia Users.
– Support for 50 Ansys Users.
• GRID M60 Evaluations: – POC deployment July 2015
– 2 GPU Servers
– 4 NVIDIA GRID M60 Cards
– Support for 96 Catia Users (double the density of K2)
![Page 6: Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...](https://reader031.fdocuments.us/reader031/viewer/2022012014/6159b1627a3408138d409a7a/html5/thumbnails/6.jpg)
Bell Helicopter Typical Performance of Server 1 day : 7 day
6
• Workday exhibited in graphs as hard offsets.
• Behaviorally Textron has room to improve server workload optimization during off-peak hours.
– Leverage environment for global engineering teams to get better utilization
• Network performance is not a limiting factor. 300+ users consume a total of <3Gbps at the core switch the entire stack is connected too.
– Each server consuming <30mbps
• Average server has 8 Engineers performing full assembly Catia manipulation
• Full assembly models roughly 40GB in RAM per user.
![Page 7: Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...](https://reader031.fdocuments.us/reader031/viewer/2022012014/6159b1627a3408138d409a7a/html5/thumbnails/7.jpg)
Textron Persona Overview – Engineering VDI
7
• 80% of Bell Helicopter engineering users are large power user VMs • 10% Jumbo, 10% small or medium
![Page 8: Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...](https://reader031.fdocuments.us/reader031/viewer/2022012014/6159b1627a3408138d409a7a/html5/thumbnails/8.jpg)
Environment Considerations
• Use Citrix Provisioning Services (PVS) rather than Machine Creation Services (MCS)
– MCS is very disk IOP dependent
– PVS only caches the bits that are being used by the OS and the application
• Use local SSD WriteCache with Memory acceleration.
• Electrical Power consumption and density should be considered
• CCU vs Dedicated VMs
– Environment management is critical to end user experience.
8
![Page 9: Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...](https://reader031.fdocuments.us/reader031/viewer/2022012014/6159b1627a3408138d409a7a/html5/thumbnails/9.jpg)
Typical Setup for Catia VMs
• NVIDIA vGPU profile “M60-1Q” and “K240Q” or “M60-2Q” and K260Q”
• 16-64GB RAM –depending on the size of the models
• 120GB base OS vDisk (Streamed from PVS)
• 250-750GB WriteCache vDisk (local SSD in the hypervisor)
• 2-4 vCPU – 2 is the minimum number of vCPUs since Catia is a single threaded application
9
![Page 10: Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...](https://reader031.fdocuments.us/reader031/viewer/2022012014/6159b1627a3408138d409a7a/html5/thumbnails/10.jpg)
NVIDIA Graphics Driver - Global Settings
• Use the “Dassault Systems CATIA - Compatible” global preset inside the NVIDIA control panel.
10
![Page 11: Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...](https://reader031.fdocuments.us/reader031/viewer/2022012014/6159b1627a3408138d409a7a/html5/thumbnails/11.jpg)
CATIA : Preselect in Geometry View
• Deselect “Preselect in geometry view”
11
NOTE: If it is selected then there is constant cross-highlighting between 3D and Tree occurring. !
![Page 12: Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...](https://reader031.fdocuments.us/reader031/viewer/2022012014/6159b1627a3408138d409a7a/html5/thumbnails/12.jpg)
CATIA : Level of detail
• Set the “Static” at about 10% (4.0) and “While Moving” at about 75% (30)
12
NOTE: This greatly increases the ability of the graphics cards to process the zoom, pan, and rotate inputs from the user.
!
![Page 13: Fred Devoir, Textron Mgr IT Infrastructure Chris Savage ...](https://reader031.fdocuments.us/reader031/viewer/2022012014/6159b1627a3408138d409a7a/html5/thumbnails/13.jpg)
Resources
• NVIDIA Performance Engineering Labs NVIDIA GRID DASSAULT CATIA V5/V6 SCALABILITY GUIDE Published March 2016 http://www.nvidia.com/CATIA-Scalability-Guide
14