FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After...
Transcript of FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After...
![Page 1: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/1.jpg)
FRACTURE WATER
RECYCLING
![Page 2: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/2.jpg)
Natural Gas Drilling in Appalachia
•Large Reserves of Natural Gas
•Vertical and Horizonal Drilling
•Fracing Necessary to Release the Gas from the Shale
•Fracing May Require Millions of Gallons of Water per Hole
![Page 3: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/3.jpg)
Problems to Overcome
•Securing the Raw Water
Rivers, Streams, Wells, etc
•Treating Flowback and Production Water
Treatment of the Water Required After Putting It Into
the Ground
Hauling to Approved Sewage Plants
•Overcoming Environmental Concerns
![Page 4: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/4.jpg)
Hauling to Sewage Plants
•Hydrocarbon & Chloride Issues
•Streams can Only Handle So Much Chlorides (already determined
by DEP)
•Hauling and Dumping Costs Are Expensive and Will Continue To
Rise
•Treated Water Often Not Returned to the Source
![Page 5: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/5.jpg)
Overcoming Treatment Problems
•Process Water on Site
•Remove Hydrocarbons and Chloride
•Reuse the Flowback and Production Water
•Deep Well disposal of Salt Brine
•Convert salt to road deicer
![Page 6: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/6.jpg)
How to Achieve These Solutions
•Have The Capability to Process Water with 300,000 TDS
•Have The Capability to Recover Up To 80% of the Fracing water
•TDS Reductions as Low as 500 mg/L (ppm) On Processed (Clean) Water
•Kerfoot Technologies Patented Treatment Process
1) Mobile Systems
2) Fixed Facilities
![Page 7: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/7.jpg)
Equipment & Processes
![Page 8: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/8.jpg)
Frac Water Recycling System
Frac WaterApparatus
Frac WaterApparatus
TreatmentApparatus
Water
Frac-Water Treated Water
To River
Make-up Water
(River)
Formation
Drill holeDrill hole
Horizontal
Fracturing
*
*U.S. Patents 6,913,251; 6,984,329; 7,264,747; 7,326,002; others pending
![Page 9: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/9.jpg)
Oil Separator
Tank
Pump
Nanozox Treatment system
Off Gas Treatment
Filtration
Salt
Removal
Storage
Tank
Baffled
Treatment tank
Alligator Bagor
20,000 gallon tank
tm
Metals
Discharge/Re-injection
Influent
Salt
Frac Water Flow Diagram
*U.S. Patents 6,913,251; 6,984,329; 7,264,747; 7,326,002; others pending
*
![Page 10: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/10.jpg)
Comparative Volume Treatment
Desalination
Water
Volume
TDS: 10,000 45,000 130,000
RO
MD
![Page 11: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/11.jpg)
Frac Water Treatment Train Efficiencies
Treatment Efficiency Limitations
Product separation 99% floating product gallons/day
(15,000)
Alkane/Alkene/VOC 99.9% <100,000 μg/L
Filtration 99% iron <100 mg/L - ppm
Desalination
Membrane Systems 80% 15,000 – 300,000 mg/L TDS
[Output: 80,000 gallons @ 1000 TDS/100,000 gallons]
![Page 12: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/12.jpg)
![Page 13: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/13.jpg)
![Page 14: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/14.jpg)
![Page 15: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/15.jpg)
0
50,000
100,000
150,000
200,000
250,000
300,000
0 1 2 3 4 5 6 7
Time(Days)
Re
turn
Flo
w(G
allo
ns
/Da
y)
Gallons/day-Case 1 Gallons/day-Case 2 TDS-Case 1 TDS-Case 2
25,000
50,000
75,000
100,000
125,000
150,000
To
tal D
isso
lve
d S
olid
s (
TD
S)-
mg
/L
Case-2
Case-1Case-2
Case-1
![Page 16: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/16.jpg)
![Page 17: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/17.jpg)
Nano to
Microbubble
Production
![Page 18: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/18.jpg)
Proposed Structure of Ozone
Circular
(O3)nˉ
Spherical
(O3)nˉ RCOSØ
Where:
R = radius
Ø = angle in 3dimension
n = number of molecules
n = aC
a = Dimension of
molecular diameter vs.
bubble circumference
![Page 19: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/19.jpg)
Nanobubble Structure
5μm
![Page 20: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/20.jpg)
Alkane/Alkene
TPH Treatment
1,000
10,000
100,000
1,000,000
0 60 120 180 240
Time
Co
nc
en
tra
tio
n
GRO(1500) GRO(6000)
![Page 21: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/21.jpg)
BTEX Treatment
1
10
100
1000
10000
0 60 120 180 240
Time
Co
nc
en
tra
tio
n
Xylenes(1500) Xylenes(6000) Benzene(6000) Trimethylbrnzene(1500)_
![Page 22: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/22.jpg)
![Page 23: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/23.jpg)
Control / Ozone Generating Trailer
![Page 24: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/24.jpg)
NANOBUBBLE CHARACTERISTICS
•Low rise rate <.001 m/minute
•Enhanced reactivity >10-8
m-1
s-1
•Negative charge Molecular arrangement
•Long half-life >20 hours
•Low surface tension <.02 g/cm
•High surface/volume ratio >5.0
•Hydrophobicity increased Preference for attacking
hydrophobic molecules
![Page 25: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/25.jpg)
![Page 26: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/26.jpg)
System Performance
TDS Volume
(gallons)
Recovered
Fraction
Recovered
Volume
(gallons)
TDS
First Day 10,900 250,000 .77 192,500 193
Third Day 32,000 225,000 .65 146,250 1200
Fifth Day 60,000 60,000 .55 33,000 1000
535,000 371,750
371,750
535,000
= 70% recovery
192,500 x 193 + 146,250 x 1200 + 33,000 x 1000
371,750
= 660 ppm
![Page 27: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/27.jpg)
![Page 28: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/28.jpg)
![Page 29: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/29.jpg)
![Page 30: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/30.jpg)
![Page 31: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/31.jpg)
![Page 32: FRACTURE WATER RECYCLING - Kerfoot Tech Water Pres.pdf · Treatment of the Water Required After Putting It Into the Ground Hauling to Approved Sewage Plants ... BTEX Treatment 1 10](https://reader031.fdocuments.us/reader031/viewer/2022030421/5aa7fb867f8b9a50528d0adf/html5/thumbnails/32.jpg)
•Qualified professionals to aid in site remediation planning.
•Bench-scale tests for treatability questions in in-house laboratory.
•Assistance in set-up, start-up and use of equipment.
•Performance evaluation.
•Trouble-shooting of performance and equipment.
Kerfoot Technologies, Inc.
766-B Falmouth Road . Mashpee. MA 02649
508-539-3002 . Fax 508-539-3566
www.kerfoottech.com
U.S. Patents: #6,436,285; #6,447,676; #6,596,161; # 6,805,798;