FPT-CPT Project Book - Electrical and Industrial Power ...pub/@eaton/@hyd/...File Name: FP-CPT...
Transcript of FPT-CPT Project Book - Electrical and Industrial Power ...pub/@eaton/@hyd/...File Name: FP-CPT...
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 1 of 28
FP- CPT
Joint Project Book for
Hydraulic Specification
Document Name.: FP-CPT Project Book
Version 2.0
Release Date: 01-January-2011
Revision Date: 01-July-2011
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 2 of 28
DOCUMENT MANAGEMENT INFORMATION
The controlled version of this document is stored on the Project Book Eaton Corp. website. http://www.eaton.com/EatonCom/Markets/Hydraulics/Markets/AutomotivePlant/GlobalApprovedSupplierProjectBooks/index.htm
Any printed copy is an uncontrolled copy. The user shall verify with the web site that he/she is in fact using the appropriate version of the specification for the specific project he/she is working on. Any questions or comments with respect to this specification should be directed to the project engineer for the specific project in question.
Revision Date Version No.
Description Section Affected
Revised By
01-January-2011 1.0 Version 1.0 prepared to comply with FPT-CPT
combined Global Hydraulic Specification All Nalin Shah
01-July-2011 2.0 Updated valve model codes & FPT logo Page7/28, All Nalin Shah
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 3 of 28
CONTENTS
1. .......................................................................................................................................................... 4 INTRODUCTION
2. .............................................................................................................................................. 5 CONTACT & SUPPORT
3. ............................................................................................................................................... 6 PRODUCT OVERVIEW
4. ................................................................................................................................... 12 ADDITIONAL INFORMATION
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 4 of 28
1. INTRODUCTION
1.1 PREFACE This document is a supplement to the FP & CPT combined specifications and defines the components to be used in order to build the machine according to them. However, in any case of dispute the content of the FP & CPT combined specifications shall be considered the only valid documents. For product application, careful attention should be paid to the technical specifications supplied by Eaton. Eaton will not be responsible for damage to people or things caused by not standard use of its products. In case of any doubt, always contact the technical department and follow exactly the instructions for dimensioning and assembling contained in the technical manual. However the OEM must verify the adaptability of the sample applications to its project and it must guarantee the observance of laws and norms in force.
1.2 Components Approval
Components to be used shall be indicated by the OEM into the Component list. The Component list can be
downloaded from the Eaton web site and shall be sent via e-mail to FP & CPT for approval. Component list shall be
filled with:
– Quantity of each component used
– Quantity of the machine that is referred to
– References of the Eaton sales or Distributor’s representative that deliver the components.
Use of different components shall be agreed with FP & CPT by mean of a written deviation request which explains
the technical reason.
1.3 Project Book BOM Please select the hydraulic components you need from the “FP-CPT Project Book BOM“.
The FP-CPT Project Book BOM is published:
http://www.eaton.com/EatonCom/Markets/Hydraulics/Markets/AutomotivePlant/GlobalApprovedSupplierProjectBooks/index.htm
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 5 of 28
2. CONTACT & SUPPORT
FP & CPT Europe (Italy) North America
Address Corso Settembrini, 167 10135 Turin (Italy)
https://gsp.extra.chrysler.com/mfg/amedd/control/index.htm
Website Project Contact Mauro Falletti
Company Fiat Powertrain Technologies S.p.A.
Office +39 01 1 0033099
Mobile Fax
E-Mail [email protected]
Project Book
Eaton GLOBAL (NORTH AMERICA) EUROPE - ITALY
210 Millwood Dr. Via Matteotti, 8
Address Surfside Beach Pessano con Bornago
SC 29575 Milan 20060, Italy
Website www.eaton.com www.eaton.com
Project Contact Thomas Moore Mauro Mezzina
Company Eaton Corporation Eaton Corporation
Office +1-843-238-8895 +39-02-95542-264
Mobile +1-864-921-0295
Fax
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 6 of 28
3. PRODUCT OVERVIEW Picture Symbol Description Model Code Notes Document Number
PVQ 013 V-PP-MC-0002-E
PVQ 020 V-PP-MC-0002-E
PVQ 032 V-PP-MC-0002-E
PVQ 045 V-PP-MC-0002-E
PVM 074 V-PUPI-TM007-E
PVM 131 V-PUPI-TM007-E
PVM 141 V-PUPI-TM007-E
Axial Piston Pump ; Variable Displacement
AEGREGA* E-PUGE-MR002-E3
AEGREGB* E-PUGE-MR002-E3
AEGREGC* E-PUGE-MR002-E3
External Gear Pump; Fixed Displacement
Pumps can be used only after approval from FP-CPT
V10 698
V20 698
Vane Pump; Fixed Displacement
Pumps can be used only after approval from FP-CPT
IHMG………………………….. ME5 MTG STYLE IHM-EN-0603
IHMP………………………….. ME6 MTG STYLE IHM-EN-0603
IHMCS………………………….. MP5 MTG STYLE IHM-EN-0603
IHMA………………………….. MS2 MTG STYLE IHM-EN-0603
Hydraulic Cylinder (Single rod)
IHMTT………………………….. MT4 MTG STYLE IHM-EN-0603
IHMGD………………………….. ME5 MTG STYLE IHM-EN-0603
IHMPD………………………….. ME6 MTG STYLE IHM-EN-0603
IHMCSD………………………….. MP5 MTG STYLE IHM-EN-0603
IHMAD………………………….. MS2 MTG STYLE IHM-EN-0603
Hydraulic Cylinder (Double rod)
IHMTTD………………………….. MT4 MTG STYLE IHM-EN-0603
DGMFN-3-Y-A1W-B1W-41 Meter out GB-2027B
DGMFN-3-Y-B1W-41 Meter out GB-2027B
DGMFN 3 Y A1W 41 Meter out GB-2027B
DGMFN 5 Y A1W B1W 30 Meter out 649
DGMFN 5 Y A1W 30 Meter out 649
Double throttle / check valve Sandwich plate
DGMFN 5 Y B1W 30 Meter out 649
DGMDC 3 Y PK 41 GB-2027B
DGMDC 3 X TK 41 GB-2027B
DGMDC 5 Y PK 30 649
Check valve Sandwich plate
DGMDC 5 X TK 30 649
DGMPC 3 ABK BAK 41 GB-2027B
DGMPC 3 ABK 41 GB-2027B
DGMPC 3 BAK 41 GB-2027B
DGMPC 5 ABK BAK 30 649
DGMPC 5 ABK BAK 30 649
Pilot Operated Check valve Sandwich plate
DGMPC 5 ABK BAK 30 649
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 7 of 28
Picture Symbol Description Model Code Notes Document Number
FN 03 20 B GB-2339A
FN 06 21B GB-2339A
Throttle check valve
FN 10 11B GB-2339A
FG 3 16 H 10 GB-514A
FG 3 32 H 10 GB-514A
FG 3 63 H 10 GB-514A
FCG 3 16 H 10 GB-514A
FCG 3 32 H 10 GB-514A
FCG 3 63 H 10 GB-514A
FCG-H02-25-B-10 V-VLSU-MC006-E
Flow control valve - Pressure Compensated
FCG-H02-50-B-10 V-VLSU-MC006-E
FCG 02 300 50 685
FCG 02 1500 50 685
FCG 02 2300 50 685
Flow control valve – Press. & Temp. Compens.
FCG 03 28 22 685
DG4V-3-2A-VM-KUPM4L-D7-HL-7-60 V-VLDI-MC011-E
DG4V-3-2N-VM-KUPM4L-D7-HL-7-60 V-VLDI-MC011-E
DG4V-3-6C-VM-KUPM4L-D7-HL-7-60 V-VLDI-MC011-E
DG4V-3-33C-VM-KUPM4L-D7-HL-7-60 V-VLDI-MC011-E
Directional Control Valves -18 Watt, (Low Watt preferred)
DG4V-3-2C-VM-KUPM4L-D7-HL-7-60 V-VLDI-MC011-E
DG4V-3-2A-VM-KUPM4L-D7-H-7-60 V-VLDI-MC011-E
DG4V-3-2N-VM-KUPM4L-D7-H-7-60 V-VLDI-MC011-E
DG4V-3-6C-VM-KUPM4L-D7-H-7-60 V-VLDI-MC011-E
DG4V-3-33C-VM-KUPM4L-D7-H-7-60 V-VLDI-MC011-E
Directional Control Valves - 30 Watt coil
DG4V-3-2C-VM-KUPM4L-D7-H-7-60
V-VLDI-MC011-E
DG4V4-012A-VM-KUPM4L-D7-HL-4-10 Pin 1 & Pin 2 : Not used V-VLDI-MC013-E
DG4V4-012N-VM-KUPM4L-D7-HL-4-10 Pin3 : 0Volt (ground ) V-VLDI-MC013-E
DG4V4-016C-VM-KUPM4L-D7-HL-4-10 Pin 4: 24 Volt ( Power ) V-VLDI-MC013-E
DG4V4-0133C-VM-KUPM4L-D7-HL-4-10 V-VLDI-MC013-E
Directional Control Valves -30 Watt, (Low Watt preferred)
DG4V4-012C-VM-KUPM4L-D7-HL-4-10 V-VLDI-MC013-E
DG4V4-012A-VM-KUPM4L-D7-H-5-10 V-VLDI-MC013-E
DG4V4-012N-VM-KUPM4L-D7-H-5-10 V-VLDI-MC013-E
DG4V4-016C-VM-KUPM4L-D7-H-5-10 V-VLDI-MC013-E
DG4V4-0133C-VM-KUPM4L-D7-H-5-10 V-VLDI-MC013-E
Directional Control Valves - 45 Watt coil
DG4V4-012C-VM-KUPM4L-D7-H-5-10 V-VLDI-MC013-E
DG5V-5-2A-VM-KUPM4L-D7-HM-7-10 V-VLDI-MC006-E
DG5V-5-2N-VM-KUPM4L-D7-HM-7-10 V-VLDI-MC006-E
DG5V-5-6C-VM-KUPM4L-D7-HM-7-10 V-VLDI-MC006-E
DG5V-5-33C-VM-KUPM4L-D7-HM-7-10 V-VLDI-MC006-E
Directional Control Valves - Pilot operated - 8 Watt coil
DG5V-5-2C-VM-KUPM4L-D7-HM-7-10
V-VLDI-MC006-E
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 8 of 28
Picture Symbol Description Model Code Notes Document Number
DGVM 3 10 R NG6(D03) - G 3/8 GB-2425
E DGSM 01Y 10 R NG10 (D05) - G ½ GB-2425
E DGVM 7X D 10 R NG16(D07) - G 3/4 GB-2425 Sub Plate
E DGVM 8X D 10 R NG25(D08) - G1 GB-2425
DGMS-3-2E-10-R - 2 Station A&B: G 3/8 , P&T : G ½
GB-2425
DGMS-3-3E-10-R - 3 Station A B Test Points G1/4 GB-2425
DGMS-3-4E-10-R - 4 Station ISO 228 Ports
DGMS-3-5E-10-R - 5 Station P & T : Both Ends GB-2425
Manifold blocks - NG6 (D03)
DGMS-3-6E-10-R - 6 Station A& B : Side Face GB-2425
DGMS-5-2E-10-R - 2 Station Available upon Request.
DGMS-5-3E-10-R - 3 Station A&B:G ½ , P&T :G 3/4
DGMS-5-4E-10-R - 4 Station A B Test Points G1/4
DGMS-5-5E-10-R - 5 Station ISO 228 Ports
DGMS-5-6E-10-R - 6 Station P & T : Both Ends
Manifold blocks - NG10 (D05)
A& B : Side Face DGAM 3 01 10R Size NG10(D05) to NG6(D03)
GB-2425
Adaptor plates
DGMA 3 GB-2425
DGMA 5 GB-2425
Sandwich plate with different configurations
Cover Plates DGMA 3 C1 10 GB-2425
KBDG4V-3 V-VLDI-MC014-E
KBFDG4V-3 V-VLPO-MC007-E1
KBSDG4V-3 V-VLPO-MC005-E
KBDG4V-5 V-VLDI-MC002-E
KBFDG4V-5 V-VLPO-MC008-E1
KBSDG4V-5 V-VLPO-MC006-E
KBDG5V-5/7/8/10 V-VLPO-MC001-E
KBFDG5V-5/7/8/10 V-VLDI-MC003-E2
Proportional directional valves with integrated electronics
KBHDG5V-5/7/8/10
For complete model code, refer appropriate literature.
V-VLDI-MC001-E2
K(B)X(C)G-6/8 V-VLPO-MC004-E
Proportional pressure control valves
For complete model code, refer appropriate literature.
KBCG-3 V-VLPO-MC002-E
EHST-3 11-07-702
KBCG5-3 V-VLPO-MC012-E
Proportional pressure relief valves
For complete model code, refer appropriate literature.
A2 30 I 060 BN M * V-FIFI-MC003-E
A2 30 I 230 BN M * V-FIFI-MC003-E
A2 30 J 578 BN M * V-FIFI-MC003-E
A2 30 J 05G BN M * V-FIFI-MC003-E
A2 30 K 10G BN M * V-FIFI-MC003-E
A2 30 L 15G BN M * V-FIFI-MC003-E
Bladder Accumulator
Bladder Accumulator * - 22 for PED
(97/23/EC) approved (for FP)
* - 20 for ASME approved (for CPT)
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 9 of 28
Picture Symbol Description Model Code Notes Document Number
Charging and test device
100AV00093A V-FIFI-MC003-E
NG 10- ESS 10E 16Y1-T250A-S10 For 1, 4 liters accumulators
V-FIFI-MC003-E
NG 20- ESS 20E 16Y1-T250A-S12 For 10, 20 liters accumulators
V-FIFI-MC003-E
NG 20- ESS 20E16Y1-T250A-S13 For 32 liters accumulator
V-FIFI-MC003-E
Accumulator Safety Block (CE Marked)
NG 32- ESS 32E16Y1-T250A-S309 For 50 liters accumulator
V-FIFI-MC003-E
DARV W 6 K 10/ 25 V-VLRE-MC003-E
DARV W 6 K 10/ 50 V-VLRE-MC003-E
DARV W 6 K 10/ 100 V-VLRE-MC003-E
DARV W 6 K 10/ 200 V-VLRE-MC003-E
DARV W 10 K 10/ 25 V-VLRE-MC003-E
DARV W 10 K 10/ 50 V-VLRE-MC003-E
DARV W 10 K 10/ 100 V-VLRE-MC003-E
Pressure relief valve ; Direct operated
DARV W 10 K 10/ 200
Valves can be used only after approval from FP-CPT. Valves can be used in the custom block
V-VLRE-MC003-E
DGMC 3 PT AW 41 GB-2027B
DGMC 3 PT BW 41 GB-2027B
DGMC 3 PT CW 41 GB-2027B
DGMC 5 PT AW B 30 649
DGMC 5 PT BW B 30 649
DGMC 5 PT CW B 30 649
DGMC 3 AT AW 41 GB-2027B
DGMC 3 AT BW 41 GB-2027B
DGMC 3 AT CW 41 GB-2027B
DGMC 5 AT AW B 30 649
DGMC 5 AT BW B 30 649
DGMC 5 AT CW B 30 649
DGMC 3 BT AW 41 GB-2027B
DGMC 3 BT BW 41 GB-2027B
DGMC 3 BT CW 41 GB-2027B
DGMC 5 BT AW B 30 649
DGMC 5 BT BW B 30 649
Pressure relief valve; Pilot operated; Sandwich plate
DGMC 5 BT CW B 30 649
DGMC2 3 AT BW BT BW 4 GB-2027B
2 Pressure relief valves; Pilot oper. ;
Sandwich plate
DGMR1 3 PP CW B 40 GB-2027B
Pressure seq. Valve - Z ;
Sandwich plate
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 10 of 28
Picture Symbol Description Model Code Notes Document Number
DGMX1 3 PP AW B 40 GB-2027B
DGMX1 3 PP BW B 40 GB-2027B
DGMX1 3 PP CW B 40 GB-2027B
DGMX2 5 PP AW B 30 649
DGMX2 5 PP BW B 30 649
DGMX2 5 PP CW B 30 649
DGMX1 3 PA AW B 40 GB-2027B
DGMX1 3 PA BW B 40 GB-2027B
DGMX1 3 PA CW B 40 GB-2027B
DGMX2 5 PA AW B 30 649
DGMX2 5 PA BW B 30 649
DGMX2 5 PA CW B 30 649
DGMX1 3 PB AW B 40 GB-2027B
DGMX1 3 PB BW B 40 GB-2027B
DGMX1 3 PB CW B 40 GB-2027B
DGMX2 5 PB AW B 30 649
DGMX2 5 PB BW B 30 649
Pressure reducing valve; Direct operated; Sandwich plate; Sleeve with hexagon and protect cap
DGMX2 5 PB CW B 30 649
X(C)G2V 6/8 GB-2321A
X(C)G2V-10 V-VLSU-MC004-E1
Pressure reducing valve, pilot operated
1 PU L 65 E-VLSC-MC001-E_E
1 PU L 250 Cartridge with Body
E-VLSC-MC001-E_E
Pressure cut-off valve, pilot operated
CG2V-6/8 & CG5V-6/8 GB-2323A Pressure cut-off valve, pilot operated CG2V-10 & CG5V-10 V-VLSU-MC001-E
58 II 170-M 3/4"-GM FOR FP See Press Block Catalogue
58 VV 170-M3/4" FOR FP See Press Block Catalogue
Quick connection Coupling
Contact AME Powertrain Controls Engineering
FOR CPT
MBR110 MOBILE-GATE 3/4" E-FIFI-MC002-E2 H2O GATE VENT BREATHER E-FIFI-MC002-E2
Air Breather
DMP Confirms to DIN Spec E-FIFI-MC002-E2
Pressure Filter with clog indicator
VDP Confirms to DIN Spec E-FIFI-MC002-E2
Pressure Filter Element
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 11 of 28
Picture Symbol Description Model Code Notes Document Number
DRT Confirms to DIN Spec E-FIFI-MC002-E2
Return line filter with clog indicator
WalRing Coupling E-MEFI-MC002-E Eaton Walterscheid Tube Coupling
Fittings
GH195 MATCHMATE Per ISO S1436/II A-HOOV-MC001-E1 Eaton Hose fittings A-HOOV-MC001-E1
Hose & Hose fittings
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 12 of 28
4. ADDITIONAL INFORMATION
4.1. SYSTEM OVERVIEW
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 13 of 28
4.2 POWER UNIT and COMPONENTS
Oil / water heat exchanger
unit Accumulator assemblies
Motor/pump group Module series
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 14 of 28
4.3 RESERVOIRS and PUMPS
All hydraulic power units must be purchased from approved Tier II Supplier. The standard power units are built with a modular principle:
a. Motor pump unit, consisting of:
a. Piston pump type PVM -continuos pressure Pmax = 250 bar (3625 psi) & PVQ -continuos pressure pmax = 140 bar (2030 psi)
b. Coupling
c. Pump flange
d. Three phase engine
b. By-pass-filtering and cooling:
a. With plate style heat exchanger
b. With vane pump
c. Accumulator assembly:
a. The recommendation of an accumulator depends from the demand of the work cycle.
d. Air filtration
a. A 10 micron filter is recommended
e. Reservoir filling and draining
a. With quick acting connection as indicated in the spec PT_TS_FL_Fluid_Power para 2.3.8
To choose the accumulator size, consult Eaton.
Both Europe North America Both
Tank Volume
Pump Type Pmax
bar (psi)
Qmax lpm at 1000 rpm**
Electrical Motor Power
kW
Qmax gpm at 1200 rpm**
Electrical Motor
Power HP
Sound level in dB(A)
measure to DIN 45365
Heat exchanger Capacity kW(hp)
70 (1015) 3 3 100 PVQ 13
100 (1450) 13
4 4
5 72-75
70 (1015) 4 5 PVQ 20
100 (1450) 20
7.5 6
10 75-78
70 (1015) 5.5 7.5 160
PVQ 32 100 (1450)
32 11
10 15
75-78
70 (1015) 4 5 PVQ 20
100 (1450) 20
7.5 6
10 75-78
70 (1015) 5.5 7.5 250
PVQ 32 100 (1450)
32 11
10 15
75-78
70 (1015) 7.5 10 PVQ 45
100 (1450) 45
11 14
15 75-78
70 (1015) 11 15
4(5.5)
PVM 074 100 (1450)
74 15
23 20
75-78
70 (1015) 15 20
400
PVM 131 100 (1450)
120 22
38 30
76-78
70 (1015) 18.5 25 PVM 131
100 (1450) 120
30 38
40 76-78
70 (1015) 22 30 630
PVM 141 100 (1450)
141 30
45 40
75-78
800 As per the requirement
1000 As per the requirement
7.5(10)
** - Pump displacement will be adjusted to max flow.
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 15 of 28
4.3.1 Power Unit with Motor Pump Group (B3/5) / C-Flange NEMA in Horizontal Version
Transport - motor- pump. Here put on its hinges. Loop laying round the motor.
Transport – complete power unit. Here put on its hinges.
Transport - Accumulator Loop laying round the accumulator
The mentioned measures are approximate measures. You get detail measures when you place the order. Please consider enough place over the parts for the disassembling!
Tank Volume Liters
L L1 B B1** H H1** H2
100 660 1097 450 786 650 1085 1527
160 850 1287 550 865 660 1095 1537
250 1050 1487 680 865 675 1110 1581
400 1400 1922 750 1276 710 1210 1616
630 1550 2072 930 1357 780 1330 1686
800 2050 2772 875 1357 780 1405 2201
1000 2050 2772 1020 1432 820 1475 2241 Dimension in mm
** - Dimensions may change for NEMA motors. Consult Eaton for further details.
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 16 of 28
4.3.2 Technical Data
Variable piston pump type PVQ
Operating Pressure Absolute
Inlet Pmin bar (psi) 0.2 (7.2)
Outlet Pnom bar (psi) 140 (2030)
Drain port Pmax bar (psi) 0.35 (5)
Oil temperature range in ºC ( ºF) -10 to 70 (14 to 158)
Viscosity range of the fluid - cSt 16 - 40 (Recommended)
1000 (Maximum at start up)
Variable piston pump type PVM
Operating Pressure Absolute
Inlet Pmin-max bar (psi) 0.85 -3.5 (5 - 50)
Outlet Pnom bar (psi) 80 -160 (1160-2320)
Drain port Pmax bar (psi) 2 (30)
Oil temperature range in ºC ( ºF) -10 to 70 (14 to 158)
Viscosity range of the fluid - cSt 16 - 40 (Recommended)
1000 (Maximum at start up)
Electrical motors
Type of Enclosure
TEFC
Phase / Frequency 3 Phase / 50 Hz (Europe), 60 Hz (North America)
No of poles 4 / 6
Voltage See PT_TS_FL_Fluid_Power specification
Drive Speed (Preferred) 1000 (Europe) /1200 (North America)
Drive Speed (Max) 1500 (Europe) /1800 (North America)
Insulation F
Degree of protection IP 55
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 17 of 28
4.3.3 Motor Pump Group
Horizontal mounting
Motor with base and flange: form of construction B3/5 (IEC) / C-Flange, with base (NEMA)
Pump with pump flange and coupling assembled on the motor
For transport: Here put on its hinges. Loop laying round the pump. P
S
Common Europe - IEC North America - NEMA
Pump Type
Pmax bar (psi)
Qmax lpm at 1000 rpm
Electrical Motor
Power kW
Frame - 1000 rpm
Weight Kg (lbf)
Qmax gpm at
1200 rpm
Electrical Motor
Power HP
Frame - 1200 rpm
Weight Kg (lbf)
70 (1015) 3 132 S 73(160) 3 213TC 102 (226) PVQ 13
100 (1450) 13
4 132 M 81(179) 4
5 215TC 130 (286)
70 (1015) 4 132 M 89(196 5 215TC 137 (303) PVQ 20
100 (1450) 20
7.5 160 M 136(300) 6
10 256TC 227 (501)
70 (1015) 5.5 132 M 108(238) 7.5 254TC 227 (501) PVQ 32
100 (1450) 32
11 160 L 172(379 10
15 284TC 279 (614)
70 (1015) 7.5 160 M 144(317) 10 256TC 265 (583) PVQ 45
100 (1450) 45
11 160 L 180(397) 14
15 284TC 286 (630)
70 (1015) 11 160 L 211(465) 15 284TC 313 (689) PVM 074
100 (1450) 74
15 180 L 293(645) 23
20 286TC 340 (750)
70 (1015) 15 180 L 319(703) 20 286TC 363 (801) PVM 131
100 (1450) 120
22 200 L 357(787) 38
30 326TC 487 (1073)
70 (1015) 18.5 200 L 330(728) 25 324TC 487 (1073) PVM 131
100 (1450) 131
30 225 M 406(895) 45
40 364TC 596 (1312)
PVM 141 70 (1015) 141 30 200 L 406(895) 45 40 364TC 596 (1312)
** - Pump displacement will be adjusted to max flow.
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 18 of 28
4.3.4 Heat Exchanger Unit
This Heat Exchanger unit shall be consisting of following items:
- Electric Motor with Hydraulic Pump, Pressure Measuring Point, Pressure Relief Valve, Pressure Hose
-Oil / Water Heat Exchanger, Electric Operated Water Valve, Water Filter, Ball Valves & Water Hoses
Technical Data
Connection thread to ISO 1179 Oil side Flanges to ISO 6162
Line ports Water Side Thread to ISO 228/1
Oil temperature range 30 to 80 ºC
Motor Voltage See PT_TS_FL_Fluid_Power specification
Water Valve Electrically operated 2/2 directional water valve
Permissible Contamination of the Fluid Class 21/19/16
For transport: Here hinge the crane
Europe North America
Thermal performance in kW (HP)
Flow max l/min at 1000 / 1500 rpm
Motor Power kW 1000 / 1500 rpm
Flow max l/min at 1200 / 1800 rpm
Motor Power hp 1200 / 1800 rpm
Total weight in kg (lbf)
4 (5.3) 18/25 0.75 20/30 1 54 (120)
7.5 (10) 31/46 1.5 37/56 2 68 (151)
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 19 of 28
4.3.5 Compact Reservoir: Aluminum Tank NG 40
a. Standard power unit:
- With vane pump
- With aluminum tank V = 40 Liter
b. Variation of controls :
- Over pressure protection
- Over pressure protection with manifolds blocks NG6
- Manifold block with accumulator charging valve
- With bladder type accumulator
- With accumulator safety block
Attention: Please consider enough places for the disassembling of the components on the power unit.
Electrical Motor IEC Frame
H**
80 / 90 590 / 630
100 / 112 670 / 690
132 770
** - For NEMA motors consult Eaton
OPTIONAL:
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 20 of 28
4.4 Hydraulic Cylinders
ISO 6020/2
Where ISO/DIN shape is available it shall be used.
Series – IHM
(Literature ID - IHM-EN-0603)
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 21 of 28
4.4.1 Hydraulic Cylinders Ordering Code (Document # - IHM-EN-0603)
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 22 of 28
4.4.2 Overview of mounting Style : Series IHM
Mounting types DIN / ISO (Please see Literature ID - IHM-EN-0603 )
4.4.3 General Notes
Air Bleed Option
Usually cylinders will bleed themselves of air when Ports are
vertical, on top. Bleed ports are often desirable to remove
entrapped air, when the ports are on the bottom. High
performance and high speed or heavy load applications are a
few examples where air bleeds are desirable.
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 23 of 28
4.4.4 Piston Ø (mm) 25 32 40 50 63 80 100 125 160 200
Max Recommended
ME5, MS2 500 500 600 600 750 750 750 900 900 900
Stroke in mm ME6, MP5, MT4 -Unsupported Rod
600 600 750 750 965 965 965 1000 1000 1000
ME6, MP5, MT4 -Supported Rod
1000 1000 1200 1200 1200 1200 1200 1200 1200 1200
Max Permissible Radial Force kN 1) 8 12.5 20 32 50 80 125 200 320 500
Maximum Velocity (m/s) Refer sealing system Paragraph 6.6
Viscosity mm2/s 2.8...380
Cleanliness Class to ISO Max. permissible degree of contamination of the hydraulic fluid to ISO 4406 (c)
class 20/18/15. 1) on piston rod guide bushing
4.4.5 Sealing System
Three different sealing systems are available in Series IHM cylinders. Determine the correct seal codes for your application
and then enter them in the model code.
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 24 of 28
4.5 Appendix : 1 Standard Power Unit without Cooling
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 25 of 28
4.6 Appendix 2: Standard Power Unit with water/oil Cooler for Tank size 100/160/250 and 400 liter
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 26 of 28
4.7 Appendix 3: Standard Power Unit with water/oil Cooler for Tank size 600 liter and larger
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 27 of 28
4.8 Appendix 4
File Name: FP-CPT Project Book V2.0-Reva .Doc Version: 2.0 Original Date: 01-January-2011 Revised Date: 01-July-2011 Page No.: 28 of 28
4.9 Appendix 5