    GPRS BASED HEART RATE

    MONITORING SYSTEM

  • 7/29/2019 fourth1st

    2/12

    OBJECTIVE2

    Real time monitoring of heart rate and display thesignal on an LCD

    Alert the doctor if there is any abnormality is

    present, using GPRS module

  • 7/29/2019 fourth1st

    3/12

    BLOCK DIAGRAM3

    ECGELECTRODES

    ECGAMPLIFIER

    & FILTER LPC2378

    LCD(128*64)

    GPRS

    ADC

  • 7/29/2019 fourth1st

    4/12

    Fan Aihua, Bian Chunhua, Ning Xinbao, He Aijun, Zhuang Jianjun

    Portable electrocardiogram monitor based on ARMInformation Technology and Applications in Biomedicine, 2008.ITAB 2008. International Conference on , pp:481 - 483 ,30-31

    May 20084

    Uses an AT91SAM7S64 arm7 processor to monitorreal time ECG ,record data, displays the wave andsends out alarm when exception is detected usingRF module.

    Arm7 has real-time timer is used for updating thecurrent date and time and timer (TC0) is used for

    timing trigger The data analysis is according to three variables:

    the RR interval, the QRS wave width and averagevalueRR of 8 RR Intervals

  • 7/29/2019 fourth1st

    5/12

    Cont..5

    Block diagram

    Software section consist of acquisition fromadc,display the ecg wave,data transfer tophone,data storage on sd card,data analysis and

    alarm,updating current time

  • 7/29/2019 fourth1st

    6/12

    Lihuang She1, Jinshuan Zhao1, Shi Zhang1, Guohua Wang1, Gang Wang1

    A Novel Portable One Lead ECG Monitor with Low-Cost and

    Long-Time Recording Based on NUC501, 2010 Chinese Control and Decision Conference,pp:276-279

    a portable low-cost long- time one lead Electrocardiogram (ECG)

    Monitor is present, which is powered by one dry battery and

    based on NUC501.

    Software has two important parts: front data processing and fast

    algorithm for R wave

    In front end processing digital filter is chosen to remove

    interference noise.

    To detect r wave we use differential threshold method, which is

    based on detecting ECG signal amplitude and slope.

  • 7/29/2019 fourth1st

    7/12

    V Thulasi Bai1 and S K Srivatsa,Design and implementation of mobile tele cardiac system,Journal of scientific & industrial research,vol. 67 ,pp:1059-1063 , october 2008

    7

    ECG is continuously monitored and details arewirelessly loaded into external memory of armprocessor using Bluetooth technology.

    RR interval of QRS wave is used to find heart rate in

    bpm For normal person this interval is 600-1000.

    If bpm is found less than 60 then it is bradycardia, ifit is above 100 then it is tachycardia

    If exception is found then it declares panic conditionand sends a 1 min sample of ECG using GSM/GPRSmodule.

  • 7/29/2019 fourth1st

    8/12

    Work done8

    Ecg waveform acquired

    F=1.041 Hz

    Vpp=1.44V

  • 7/29/2019 fourth1st

    9/12

    WORK DONE9

    Done adc in lpc2378

    Plot adc output on 128*64 pixel graphic Lcd

    Interfaced sim900 module with lpc2378

  • 7/29/2019 fourth1st

    10/12

    Graphic lcd10

    Flow chart for initilization and display of lcd

  • 7/29/2019 fourth1st

    11/12

    Work to be done11

    Find number of heart beats from ECG usingmicrocontroller

    Send data using GPRS module if abnormality occurs