AREAS OF APPLICATION Concrete formwork systems Wall formwork Floor formwork Formwork for engineered structures (bridge constructions, foundations)

Tunnel formwork

ADVANTAGES Dimensionally stable through a locked lay-up Almost no crack occurence High bending strength and stiffness Sanded surface for perfect results Lower costs due to a higher number of reuses High endurance due to gluing all around

01AT A GLANCE

PRODUCT STANDARDÖNORM B 3023

THICKNESSES21 mm27 mm

FORMATSWidths: 500 mmLengths: 1,000 to 3,000 mm in 500 mm steps

SURFACESanded and sealed with melamine resin

02OVERVIEW

EDGESEdges glued with end strips, sealed with acrylic coating

WOOD SPECIESCover layer: Spruce/firMiddle layer: Spruce, fir, pine

SUSTAINABILITYThe HASSLACHER Group stands for a careful use of wood as a resource. Our raw materials come from sustainable and controlled forestry. Our locations are certified according to the strict PEFCTM standards.

HASSLACHER NORICA TIMBER | FORMWORK PANELS2

Page 3: FORMWORK PANELS - HASSLACHER NORICA TIMBER...Nailing, drilling or screwing through the Formwork panels should be minimised, since they impair the Formwork panels’ protective coating,

BONDINGAlkaline-resistant, water and weatherproof bonding

MOISTURE CONTENT15% ±3% at time of delivery

MASS IN KG/M2

21 mm thickness: 10.0 kg/m²27 mm thickness: 12.5 kg/m²

DENSITYApproximately 450 kg/m³ to 500 kg/m³

SHRINKAGE AND SWELLING BEHAVIOURPerpendicular to panel planeau,90 = 0.24% per 1% change in moisture content

Parallel to the panel planeau,0 = 0.01% per 1% change in moisture content

SURFACE Quality Selection Standard quality Surface sanded Treated with durable melamine resin sealant

DIMENSIONAL TOLERANCESin accordance to EN 13353

Length, width: limit deviations ±2 mmPanel thickness: 0.5 mm within a panel, limit deviations ±1 mm

Edge straightness: 1.0 mm/mPerpendicularity: 1.0 mm/m

03TECHNICAL DATA

FORMWORK PANELS | HASSLACHER NORICA TIMBER 3

Page 4: FORMWORK PANELS - HASSLACHER NORICA TIMBER...Nailing, drilling or screwing through the Formwork panels should be minimised, since they impair the Formwork panels’ protective coating,

04TABLES FOR PRELIMINARY DESIGN

DEFLECTION OF FORMWORK PANELS LIP BLED D.D.3-LAYERED, THICKNESS 27 MM

DEFLECTION OF FORMWORK PANELS LIP BLED D.O.O.3-LAYERED, THICKNESS 21 MM

5.0

4.5

4.0

3.5

3.0

2.5

2.0

1.5

1.0

0.5

0.0

0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75

20.0 kN/m2

15.0 kN/m2

12.5 kN/m2

10.0 kN/m2

7.5 kN/m2

5.0 kN/m2

2.5 kN/m2

De

fle

ctio

n (

mm

)

Width between supports L (m)

L L L L

Belastung q [kN/m²] Load q (kN/m2)

3.5

3.0

2.5

2.0

1.5

1.0

0.5

0.0

0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75

De

fle

ctio

n (

mm

)

30 kN/m2

25 kN/m2

20 kN/m2

15 kN/m2

10 kN/m2

5 kN/m2

2 kN/m2

L L L L

Belastung q [kN/m²] Load q (kN/m2)

Width between supports L (m)

HASSLACHER NORICA TIMBER | FORMWORK PANELS4

Page 5: FORMWORK PANELS - HASSLACHER NORICA TIMBER...Nailing, drilling or screwing through the Formwork panels should be minimised, since they impair the Formwork panels’ protective coating,

05DURABLEMAINTENANCE, STORAGE, CLEANING AND TREATMENT.

RECOMMENDATIONS FOR USEIn order to maximize the number of use cycles and the longest endurance, the following recommendations have to be considered.

The plates are to be treated with an appropriate form oil and sprayed with sufficient water immediately before concreting.

After removing the shuttering, the plates should be cleaned as fast as possible and stored on a level surface.

Suitable forming oils are recommended for maintenance. Please use them according to the manufacturer’s instructions.

Nailing, drilling or screwing through the Formwork panels should be minimised, since they impair the Formwork panels’ protective coating, and therefore its endurance.

FORMWORK PANELS | HASSLACHER NORICA TIMBER 5

Page 6: FORMWORK PANELS - HASSLACHER NORICA TIMBER...Nailing, drilling or screwing through the Formwork panels should be minimised, since they impair the Formwork panels’ protective coating,

06PRODUCT PORTFOLIO

PANEL FORMATSThickness 21 mm, 27 mmFormats 500 x 1,000 mm, 500 x 1,500 mm, 500 x 2,000 mm, 500 x 2,500 mm, 500 x 3,000 mm

PACKAGING UNITS

Thickness Format [mm] Pieces per packet m² per packet

21 mm

500 x 1,000 2 x 50 50 m²

500 x 1,500 2 x 50 75 m²

500 x 2,000 2 x 50 100 m²

500 x 2,500 2 x 50 125 m²

500 x 3,000 2 x 50 150 m²

27 mm

500 x 1,000 40 20 m²

500 x 1,500 40 30 m²

500 x 2,000 40 40 m²

500 x 2,500 40 50 m²

500 x 3,000 40 60 m²Other packaging units are also available on request. Every packet is wrapped in a plastic cover.

HASSLACHER NORICA TIMBER | FORMWORK PANELS6

Page 7: FORMWORK PANELS - HASSLACHER NORICA TIMBER...Nailing, drilling or screwing through the Formwork panels should be minimised, since they impair the Formwork panels’ protective coating,

Glued laminated timber

Surfaced timber

Cross laminated timber

Pellets

Glued ceiling systems

Sawn timber

Glued laminated timber – special components

Formwork panels

Structural finger jointed solid timber & GLT®

Special products

Glued solid timber Duo/Trio

Pallets & packaging solutions

HASSLACHER NORICA TIMBER’S PRODUCT PORTFOLIO

07

FORMWORK PANELS | HASSLACHER NORICA TIMBER 7

Page 8: FORMWORK PANELS - HASSLACHER NORICA TIMBER...Nailing, drilling or screwing through the Formwork panels should be minimised, since they impair the Formwork panels’ protective coating,

HASSLACHER groupFeistritz 1 | 9751 Sachsenburg | AustriaT +43 4769 22 49-0 | F +43 4769 22 49-129 [email protected] | hasslacher.com

UP

PE

RC

UT.

at

HNT0210_DE_201902