Parts Needed
-
8/16/2019 Formaldehyde System
3/22
Syringe BlocThis will need to be made at a machine shop
-
8/16/2019 Formaldehyde System
4/22
Air CylinderMcMaster CarrPart #: 6498K635
-
8/16/2019 Formaldehyde System
5/22
Foot Bracket Cylinder MountMcMaster CarrPart #: 6498K33
-
8/16/2019 Formaldehyde System
6/22
Percentage TimerMcMaster CarrPart #: 2827T1
-
8/16/2019 Formaldehyde System
7/22
Polyurethane TubingMcMaster CarrPart #: 5648K252
Tubing ordered in
red to differentiate
from air lines or
humidificationlines
-
8/16/2019 Formaldehyde System
8/22
WickingThe Wick StorePart #: 1613
-
8/16/2019 Formaldehyde System
9/22
20 ml SyringeContact your local Merck representative
-
8/16/2019 Formaldehyde System
10/22
Check ValveContact Merck representative
-
8/16/2019 Formaldehyde System
11/22
Syringe and Check Valve
Assembly
-
8/16/2019 Formaldehyde System
12/22
Air RegulatorMcMaster CarrPart #: 9892K22
-
8/16/2019 Formaldehyde System
13/22
Tubing AdapterPush to fit to tubingMcMaster Carr
Part #: 51055K58
-
8/16/2019 Formaldehyde System
14/22
Tubing Adapter to Push To Fit
Connector
Wicking
attaches to
this spot
-
8/16/2019 Formaldehyde System
15/22
Air Metering ValveMcMaster CarrPart #: 62005K124
-
8/16/2019 Formaldehyde System
16/22
Solenoid ValveOrder from Humphrey onlineHumphrey H180-4E1
120 Volt
-
8/16/2019 Formaldehyde System
17/22
Wick Assembly in the Hatcher
-
8/16/2019 Formaldehyde System
18/22
Timer/Syringe Block Assembly
in Front of Hatcher
-
8/16/2019 Formaldehyde System
19/22
Timer/Syringe Block Assembly
in Front of Hatcher
Valve added to help when
adding a new jug of
formaldehyde
-
8/16/2019 Formaldehyde System
20/22
Procedures
-
8/16/2019 Formaldehyde System
21/22
Start/Stop Procedure***Formaldehyde dropped at transfer one time48 hours before hatch-pull, formaldehyde is dropped every 30 minutes
Formaldehyde is stopped 2 hours before hatch-pull
***This will change depending on size of cabinet
-
8/16/2019 Formaldehyde System
22/22
Timer SettingsDrop 20 ml of formaldehyde every 30 minutes to maintain 40-60 ppmduring the hatching process
This works for a medium Platinum hatcher cabinet