Introduction Product Details Competitors Contact Information Questions END.
For technical questions, please contact AmRad at 1.800.445 ......For technical questions, please...
Transcript of For technical questions, please contact AmRad at 1.800.445 ......For technical questions, please...
![Page 1: For technical questions, please contact AmRad at 1.800.445 ......For technical questions, please contact AmRad at 1.800.445.6033 or Turbo Easy-Start CAPACITANCE (MFD) RANGE REQUIRED](https://reader035.fdocuments.us/reader035/viewer/2022081621/6126bd4d74c502278a006b31/html5/thumbnails/1.jpg)
For technical questions, please contact AmRad at 1.800.445.6033or www.amradmanufacturing.com
![Page 2: For technical questions, please contact AmRad at 1.800.445 ......For technical questions, please contact AmRad at 1.800.445.6033 or Turbo Easy-Start CAPACITANCE (MFD) RANGE REQUIRED](https://reader035.fdocuments.us/reader035/viewer/2022081621/6126bd4d74c502278a006b31/html5/thumbnails/2.jpg)
Turbo Easy-Start CAPACITANCE (MFD)
RANGE REQUIRED
108 to 130 mfds
JUMPER WIREREQUIRED
NONE
[Shown connected to a Turbo®200 which has been wired to provide 50mfd for the herm (compressor) and a 7.5mfd fan value].
FAN
Compressor
Common
50mfd
7.5mfd
Turbo Easy-Start Standard Dual-ValueMotor-Run Capacitor
Turbo®200 Universal Motor-Run
Capacitor
50
(C)
(Herm)
(F)
Jumper Wires
Standard Single-ValueMotor-Run Capacitor
2.5(3.0)
50mfd
10
[Typical Commercial Refrigeration Application]
[Typical Air Conditioning Application]
[Typical Air Conditioning Application]
Turbo Easy-Start
Turbo Easy-Start
EX
AM
PL
E 1
EX
AM
PL
E 2
EX
AM
PL
E 3
[Shown connected to a 50+7.5mfd dual-value capacitor].
[Shown connected to a 50mfd single-value capacitor].
P.R.
5
5
50P.R. 20
25
50P.R.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE TURBO®200 MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
JumperWire
Turbo Easy-Start CONNECTED TO STANDARD DUAL-VALUE MOTOR-RUN CAPACITORStep 1: No jumper wires required.Step 2: Connect the black wire (common) from Turbo Easy-Start to the COMMON (C) termi-nal of the standard dual-value motor-run capacitor as shown. Step 3: Connect the white wire from the Easy-Start to the HERM terminal of the standard dual-value motor-run capacitor as shown.
Turbo Easy-Start CONNECTED TO A TURBO®200 UNIVERSAL CAPACITORStep 1: No jumper wires required (on the Easy-Start).Step 2: Connect the black wire (common) from the Easy-Start to the COMMON (C) terminal of the Turbo®200 Universal Capacitor as shown. Step 3: Connect the white wire from the Easy-Start to the 20MFD terminal of the Turbo®200 Universal capacitor as shown.
Turbo Easy-Start CONNECTED TO A STANDARD SINGLE-VALUE MOTOR-RUN CAPACITORStep 1: No jumper wires required (on the Easy-Start).Step 2: Connect the black wire (common) from the Easy-Start to one of the terminals of the standard single value motor-run capacitor as shown. Step 3: Connect the white wire from the Easy-Start to the other terminal of the standard single value motor-run capacitor as shown.
UP
TO
1 T
ON
TURBO EASY-START CAPACITANCE (MFD)
RANGE REQUIRED
189 to 227 mfds
JUMPER WIREREQUIRED
Green Jumper Wire
[The Turbo Easy-Start is shown connected to a Turbo®200 which has been wired to provide 60mfd for the herm (compressor) and a 7.5mfd fan value].
FAN
Compressor
Common
60mfd
7.5mfd
Turbo Easy-Start Standard Dual-ValueMotor-Run Capacitor
Turbo®200 Universal Motor-Run
Capacitor
(C)
(Herm)
(F)
Jumper Wires
Standard Single-ValueMotor-Run Capacitor
2.5(3.0)
60mfd
[Typical Commercial Refrigeration Application]
[Typical Air Conditioning Application]
[Typical Air Conditioning Application]
Turbo Easy-Start
Turbo Easy-Start
EX
AM
PL
E 1
EX
AM
PL
E 2
EX
AM
PL
E 3
[Shown connected to a 60+7.5mfd dual-value capacitor].
[Shown connected to a 60mfd single-value capacitor].
50
50
5
5
50
10
25
20
P.R.
P.R.
P.R.
RANG
E 189M
FD-227
MFD
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE TURBO®200 MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.Jumper Wire
Jumper Wire
Jumper Wire
JumperWire
Turbo Easy-Start CONNECTED TO STANDARD DUAL-VALUE MOTOR-RUN CAPACITORStep 1: Using the green jumper wire, connect the purple and yellow terminals to the corresponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to the COMMON (C) terminal of the standard dual-value motor-run capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the HERM terminal of the standard dual-val-ue motor-run capacitor as shown.
Turbo Easy-Start CONNECTED TO A TURBO®200 UNIVERSAL CAPACITORStep 1: Using the green jumper wire, connect the purple and yellow terminals to the corresponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to the COMMON (C) terminal of the Turbo®200 Universal Capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the 20MFD terminal of the Turbo®200 Univer-sal capacitor as shown.
Turbo Easy-Start CONNECTED TO A STANDARD SINGLE-VALUE MOTOR-RUN CAPACITORStep 1: Using the green jumper wire, connect the purple and yellow terminals to the corresponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to one of the terminals of the standard single value motor-run capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the other terminal of the standard single value motor-run capacitor as shown.
1 TO
2 T
ON
STURBO EASY-START CAPACITANCE (MFD)
RANGE REQUIRED
233 to 280 mfds
JUMPER WIREREQUIRED
Red Jumper Wire
FAN
Compressor
Common
80mfd
10mfd
Turbo Easy-Start Standard Dual-ValueMotor-Run Capacitor
Turbo®200X Universal Motor-Run
Capacitor
(C)
(Herm)
(F)
Standard Single-ValueMotor-Run Capacitor
80mfd
[Typical Commercial Refrigeration Application]
[Typical Air Conditioning Application]
[Typical Air Conditioning Application]
Turbo Easy-Start
Turbo Easy-Start
EX
AM
PL
E 1
EX
AM
PL
E 2
EX
AM
PL
E 3
[Shown connected to a 80+10mfd dual-value capacitor].
[Shown connected to a 80mfd single-value capacitor].
20
107.5
50P.R.
50
50
P.R.
50
P.R.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE TURBO®200X MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
[The Turbo Easy-Start 5 is shown connected to a Turbo®200X which has been wired to provide 80mfd for the herm (compressor) and a 10mfd fan value].
Jumper Wire
Jumper Wire
Jumper Wire
JumperWire
JumperWires
5
5
Turbo Easy-Start CONNECTED TO STANDARD DUAL-VALUE MOTOR-RUN CAPACITORStep 1: Using the red jumper wire, connect the purple, yellow and red terminals to the corresponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to the COMMON (C) terminal of the standard dual-value motor-run capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the HERM terminal of the standard dual-val-ue motor-run capacitor as shown.
Turbo Easy-Start CONNECTED TO A TURBO®200 UNIVERSAL CAPACITORStep 1: Using the red jumper wire, connect the purple, yellow and red terminals to the correspond-ing colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to the COMMON (C) terminal of the Turbo®200X Universal Capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the 50MFD terminal of the Turbo®200X Universal capactor as shown.
Turbo Easy-Start CONNECTED TO A STANDARD SINGLE-VALUE MOTOR-RUN CAPACITORStep 1: Using the red jumper wire, connect the purple, yellow and red terminals to the corresponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to one of the terminals of the standard single value motor-run capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the other terminal of the standard single value motor-run capacitor as shown.
2.5
TO 3
TO
NS
3.5
TO 5
TO
NS
TURBO EASY-START CAPACITANCE (MFD)
RANGE REQUIRED
270 to 324 mfds
JUMPER WIREREQUIRED
Yellow Jumper Wire
FAN
Compressor
Common
55mfd
10mfd
Turbo Easy-Start Standard Dual-ValueMotor-Run Capacitor
Turbo®200 Universal Motor-Run
Capacitor
(C)
(Herm)
(F)
JumperWires
Standard Single-ValueMotor-Run Capacitor
2.5(3.0)
55mfd
[Typical Commercial Refrigeration Application]
[Typical Air Conditioning Application]
[Typical Air Conditioning Application]
Turbo Easy-Start
Turbo Easy-Start
EX
AM
PL
E 1
EX
AM
PL
E 2
EX
AM
PL
E 3
[Shown connected to a 55+10mfd dual-value capacitor].
[Shown connected to a 55mfd single-value capacitor].
5
5
10
25
50
50
50
P.R. 20
P.R.
RANG
E 270M
FD-32
40MFD
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE TURBO®200 MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
[The Turbo Easy-Start is shown connected to a Turbo®200 which has been wired to provide 55mfd for the herm (compressor) and a 10mfd fan value].
Jumper Wire
Jumper Wire
Jumper Wire
JumperWire
P.R.
Turbo Easy-Start CONNECTED TO STANDARD DUAL-VALUE MOTOR-RUN CAPACITORStep 1: Using the yellow jumper wire, connect the purple, yellow, red and brown terminals to the corresponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to the COMMON (C) terminal of the standard dual-value motor-run capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the HERM terminal of the standard dual-val-ue motor-run capacitor as shown.
Turbo Easy-Start CONNECTED TO A TURBO®200 UNIVERSAL CAPACITORStep 1: Using the yellow jumper wire, connect the purple, yellow, red and brown terminals to the corre-sponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to the COMMON (C) terminal of the Turbo®200 Universal Capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the 20MFD terminal of the Turbo®200 Universal capacitor as shown.
Turbo Easy-Start CONNECTED TO A STANDARD SINGLE-VALUE MOTOR-RUN CAPACITORStep 1: Using the yellow jumper wire, connect the purple, yellow, red and brown terminals to the corresponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to one of the terminals of the standard single value motor-run capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the other terminal of the standard single value motor-run capacitor as shown.
AM
RA
D’S
UN
IVER
SAL
TUR
BO
EA
SY-S
TAR
T W
IRIN
G IN
STR
UC
TIO
NS
IMP
OR
TAN
T N
OTE
: IF
THE
EXIS
TIN
G M
OTO
R-R
UN
CA
PAC
ITO
R H
AS
RU
STED
TER
MIN
ALS
,
IT S
HO
ULD
BE
REP
LAC
ED P
RIO
R T
O IN
STA
LLIN
G T
HE
TUR
BO
EA
SY-S
TAR
T.