For Digital Bite Pressure And Occlusal Analysis...
Transcript of For Digital Bite Pressure And Occlusal Analysis...
TM
Nupai Bite ScanFor Digital Bite Pressure And Occlusal Analysis Device
The Introduction Of
The Most Economic
Computerized Occlusal
Analysis Device In The World Of
Digital Dentistry.
S
TM
Nupai Bite ScanFor Digital Bite Pressure And Occlusal Analysis Device
Manufactured By:Fuji- Japan.
Modified & Assembled in India By :Nupai Analyticals DK Bypass, GT Road, UP. IndiaEmail : [email protected]
Marketed in India By :BVM Meditech Pvt LimitedE mail : [email protected] Contact : Alok VashisthContact # : +91-9873437707
VISUAL ANALYSIS
TM
Nupai Bite ScanFor Digital Bite Pressure And Occlusal Analysis Device
TM
Nupai Bite ScanFor Digital Bite Pressure And Occlusal Analysis Device
TMJD can be analysed & treated by Computerized Occlusal Analysis and Manual Facial Muscle Assesment also (Palm EMG- pressing, feeling bilateral massaters movements with both the palms), virtually the digital occlusal analysis and Facial muscle assesment by Palm EMG protocols may be suffice for conservative treatment purpose with success, if the aims are not research oriented.
As a matter of fact, we have the ultimate aim to decompress the condyle disc in almost all cases destined for non-surgical treatment. And GOLDEN AIM is to give Balanced Occlusion for stopping further deterioration in existing TMJD cases and prevention in newer cases.
And you get much more analytical data options which open research avenues to understand the importance of knowing absolute pressure values for MFPS treatment and its relationship with Posture. The same device can be used for posture Analysis also.
OCCLUSION –TMJD & OUR OBJECTIVES
Software & Sensor Features:
Ÿ Understanding High Pressure Points in the Bite?
Ÿ Realizing about Articulating paper's limitation and its role?
Ÿ Bite Pressure and its Relationship with TMJD prevention?
Ÿ Bite Pressure and its Relationship Facial Muscles?
Ÿ Bite Pressure, EMG combination and its treatment protocols for TMJD?
Ÿ Importance of Knowing Centre of force in Occlusal Analysis. Learn with experience.
Ÿ Left Vs Right Pressure Balance and % ratio.
Ÿ Importance of Knowing Left and Right Excursions.
Ÿ Importance of Knowing Absolute Pressure Values (APV).
Ÿ What is normal APV?
Ÿ What is abnormal threshold of APV, which may be causing MFPS?
Ÿ Opening of new research avenues in Facial Pain Syndrome understanding.
Ÿ MFPS and relationship with posture, Standing Pressure Analysis !!
And FUJI made it ABSOLUTLY ECONOMIC to you ..!!
NEW & IMPORTANT USEFUL FEATURES OF ANY DIGITAL OCCLUSAL ANALYSIS ARE :Ÿ 2D Graph
Ÿ 3D Graph
Ÿ Centre of total Force
Ÿ Left Vs Right % Ratio
Ÿ Anterior vs Posterior % Ratio
Ÿ High Pressure Point in 2D
Ÿ High Pressure Point in 3D
Ÿ Individual Pressure Mark Value…
...AND MUCH MORE….
Code Name Pressure Range Mpa Range Psi Size Dimension (mm)
NBS-M-L Nupai Bite Scan Medium 10 to 50 1450 to 7250 Large 68 x 50
NBS-M-S Nupai Bite Scan Medium 10 to 50 1450 to 7250 Small 62 x 44
NBS-L-L Nupai Bite Scan Low 2.5 to 10 363 to 1450 Large 68 x 50
NBS-L-S Nupai Bite Scan Low 2.5 to 10 363 to 1450 Small 62 x 44
NPAS-M-STD Nupai Pressure Analysis Strips High 10 to 50 1450 to 7250 Std-3 17 x 30
NPAS-L-STD Nupai Pressure Analysis Strips Low 2.5 to 10 363 to 1450 Std-3 17 x 30
Note : We can provide lower or higher pressure sensitive products for research applications.
1 MPa = 10.2 kgf /cm sq
1psi = 6895 pa
DIGITAL ANALYSIS
LS
Nupai Bite Scan Sensor Scanner 2D Graph 3D Graph
QUICK STEPS: PREPARE - SCAN - ANALYSE
TM
Nupai Bite ScanFor Digital Bite Pressure And Occlusal Analysis Device