Fluorescence live cell movie analyzer - VWR
Transcript of Fluorescence live cell movie analyzer - VWR
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer
Fluorescence live cell movie analyzer
Understanding cellular growth, behavior and morphology
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer 2
About
The JuLI™ FL, is the next generation of a smart fluorescence live cell movie
analyzer & counter.
The JuLI™ FL uses state-of-the-art optics to get live-cell images from
various cell culture dishes and can be performed cell-based assays, including
cell counting, cell viability and GFP/RFP expression level checking.
This also enables user to support the quantified cell confluence results with low
variation and the growth curve using image based analysis for bright field.
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer 3
Appearance (Whole body)
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer 4
Appearance (Scopes)
For GFP channel
For RFP channel
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer
Dual system (*Optional) Allow to compare the control and experimental
samples using dual system.
5
Compatible to CO2 incubator
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer
Versatility (Flexibility)
Features
Time-lapse image capturing and movie making
Cell counting and viability
GFP or RFP expression level checking
Dual system for comparative data (* optional)
Accuracy
Automated confluence detection & growth curve
Semi-Auto focusing with low variation
Ease of use
Intuitive & user friendly interface with LCD touch screen
Compact size optimized for an cell culture incubator
Simple steps for the system setup and the operations
Live cell
imaging Cell counting
& viability Expression
level check
Dual system
Confluence detection
Compact
for incubator User friendly
Real time
growth curve
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer 7
Live cell imaging (time lapse)
Cell growth monitoring
Cell migration assay
Cell confluence detection
Cell culture quality control
Proliferation assay
Stem cell development
Cell-based assay optimization
Cell counting & Viability
Transfection efficiency (GFP or RFP Expression)
Applications
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer 8
Applications
Cell confluence detection
Cell confluence determined various cell lines
Real-time cell growth curve
NIH-3T3 cells growth were observed 50 hours through JuLI™ Br. All images were recorded every 10 minute
and analyzed monolayer confluence.
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer 9
Applications
Time-lapse image capture and movie making
Cell-growth images were captured for 63 hours with 20 minutes intervals in U-2 OS GFP & RFP stable cell line.
Live cell image capture
U-S OS cells were transfected using the Neon™ transfection system (from Life Technologies) and 0.25 µg of the
the EGFP-N1 plasmid & RFP plasmid. 48 hours after transfection, the images are captured.
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer 10
Applications
Cell migration (wound healing) assay
U-2OS stable cells were incubated for 100 hours after scratch. JuLITM FL calculated the confluence with growth
of surface unfarmed automatically.
Bright field
Wound confluence can be graphed to
quantitatively analysis the recovering
the surface of wound.
(Bright field only)
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer 11
Applications
Cell counting & viability
Clumped cell (HepG2, MCF7, F9) cells were counted with a JuLITM FL, a hemocytometer and the competitor’s automated
cell counter. Accuracy and precision are comparable between the JuLITM FL and the hemocytometer for all cell lines.
Cell counting results were performed on three different instruments with seven sample replicates
Fluorescence expression level checking
JuLITM FL counting software provides actual cell counts, viability and automatically calculates cell concentration.
It also can identify and measure the levels of fluorescence (GFP or RFP expression).
Transfection efficiency (A) Fluorescence intensity gating (B)
GFP expressing cells (U-2 OS) were counted using JuLITM FL counting software (A). The histograms in
graph (B) show the green fluorescence intensity of the cells.
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer
Software description
Focusing menu Monitoring menu
Data menu Setting menu
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer
Cell-growth images were captured for 63 hours with 20
minutes intervals in U-2 OS GFP stable cell line.
13
Movie data
U-2 OS GFP stable cells proliferations
Cell-growth images were captured for 63 hours with 20
minutes intervals in U-2 OS RFP stable cell line.
U-2 OS GFP stable cells proliferations
http://youtu.be/1EnTch0TouM
http://youtu.be/JoWjjLlU54M
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer 14
Movie data
Cell migration (wound healing) assay
U-2OS stable cells were incubated for 100 hours after
scratch. JuLITM FL calculated the confluence with growth
of surface unfarmed automatically.
http://youtu.be/k-zqhFI6nuw
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer 15
Specification
Magnification 4 X and digital zoom ( ~ 450 X)
Image resolution 1280 x 960 pixels (1.3 M)
Exported formats JPEG, TIFF, BMP, PNG (image), AVI (movie), CSV (raw data)
Display 10.1” LCD touch screen
Light source GFP channel (JULI-FLG04): Blue LED
RFP channel (JULI-FLR04): Green LED
Optical filter GFP channel (JULI-FLG04): Excitation 466/40 nm, Emission 525/50 nm
RFP channel (JULI-FLR04): Excitation 525/50 nm, Emission 580LP
Dimension & Weight Scope unit : 300 x 190 x 188 mm, 4.5 kg
Station unit : 282 x 285 x 160 mm, 3.2 kg
Storage 320 GB Hard drive, 4 GB USB drive
Power AC100 - 240Va.c.,, 1.9A, 100w, 50/60 Hz
Operating Environment 5 - 40 °C, 20 – 95 %
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer 16
Ordering information
Cat. No. Description Remark
Device
JULI-FLG04 JuLI FL (Single set)
For GFP channel JULI-FLGD04 JuLI FL (Dual set)
JULI-FGSC Scope unit of JuLI FL
JULI-FLR04 JuLI FL (Single set)
For RFP channel JULI-FLRD04 JuLI FL (Dual set)
JULI-FRSC Scope unit of JuLI FL
Accessories
JULI-BRCM Counting starter kit Counting module set, Cell counting slide
JULI-BRTB XY stage
Disposable
JULI-BRS50 Cell counting slide 50 slides (100 counts)
JULI-BRS1000 Cell counting slide 1,000 slides (2,000 counts)
JULI-BRS5000 Cell counting slide 5,000 slides (10,000 counts)
Copyright 2013 @ NanoEnTek Inc. All rights reserved Fluorescence Live cell movie analyzer
Appendix_Magnification
Field of view comparison
1.21 mm
0.92 mm
138.92 mm
104.19 mm
Field of view (Actual, Camera)
1.21 x 0.92 = 1.113 mm2
Field of view (Display, LCD Screen)
138.92 x 104.19 = 14474 mm2
Full size (X1) 114X
Zoom in (Digital X4) 228X
Zoom in (Digital X16) 456X
18
Copyright 2013 @ NanoEnTek Inc. All rights reserved V.1.0 (Sept, 2013)
Fluorescence live cell movie analyzer
Website
www.nanoentek.com
NanoEnTek Inc. (HQ)
12F, 5, Digital-ro 26-gil, Guro-gu, Seoul, 152-740, Korea
Tel : +82-2-6220-7940 / Fax : +82-2-6220-7721
NanoEnTek USA Inc.
5627 Stoneridge Drive Suite 304, Pleasanton, CA 94588, USA
Tel : +1-925-225-0108, +1-888-988-0108(Toll free)