Fluid management & Gingival Displacement

100
FLUID CONTROL AND GINGIVAL DISPLACEMENT PRESENTED BY- NAZAM TAFADAR FINAL YEAR BDS GUIDED BY: Dr MANJULA DAS HEAD OF DEPARTMENT, PROSTHODONTICS

Transcript of Fluid management & Gingival Displacement

Page 1: Fluid management & Gingival Displacement

FLUID CONTROL AND GINGIVAL

DISPLACEMENT

PRESENTED BY- NAZAM TAFADARFINAL YEAR BDS

GUIDED BY:Dr MANJULA DAS HEAD OF DEPARTMENT, PROSTHODONTICS

Page 2: Fluid management & Gingival Displacement

CONTENTSIntroductionFluid control

Objectives of fluid control and tissue management Mechanical methods chemical methods

 Soft tissue management

Mechanical technique Chemico-mechanical technique Surgical techniques

Recent advancesNew gingival retraction agentsDiscussionConclusion Bibliography

Page 3: Fluid management & Gingival Displacement

INTRODUCTION To obtain a accurate impression control

of fluids and appropriate displacement of gingiva are essential. Impression making is technique sensitive because accurate reproduction of finish line is essential for the fabrication of fixed partial denture. Fluid control and gingival displacement enhance the operator visibility , increased patient comfort, and aid in exacting optimum benefits from the impression and cementation procedure.

Page 4: Fluid management & Gingival Displacement

When the preparation margins extend subgingivally, the adjacent tissues must be retract or displaced laterally to allow acess and to provide adequate thickness of the impression material. This may require enlarging the gingival sulcus through mechanical , chemical , or surgical means and must be done without jeopardizing periodontal health.

Page 5: Fluid management & Gingival Displacement

FLUID CONTROL Objectives 1) to obtain a dry clean operating field . 2) to enhance operating visibility and

patient comfort. 3) improve the properties of restorative

material. 4) to improve the operating efficiency. 5) protect from swallowing and aspirating

foreign bodies.

Page 6: Fluid management & Gingival Displacement

Sources of moisture in clinical environment

Saliva

Salivary glands-parotid, submandibular, sublingual

The mean flow rate (+/- SD) of unstimulated saliva was 0.26 +/- 0.16 ml/min and that of saliva while chewing six different foods was 3.6 +/- 0.8 ml/min.

BloodInflamed gingival tissues/Iatrogenic damage

Page 7: Fluid management & Gingival Displacement

Water/dental materialsRotary instruments, triplex syringe, etchants, irrigant solutions

On a average has high speed rotatory cutting instrument is 30 mL per minute

Gingival crevicular fluid0.05 to 0.20 µL per minute

Page 8: Fluid management & Gingival Displacement

METHOD OF FLUID CONTROL Mechanical Chemical other

Page 9: Fluid management & Gingival Displacement

Mechanical methods

• Rubber dam • Suction devices• High volume vacuum• Saliva ejector• Svedopter• Cotton rolls

Page 10: Fluid management & Gingival Displacement

Rubber damIntroduced by S C Barnum, 1864

Uses For core build up, pattern fabrication Impression making of inlays and onlays Removal of old restoration and caries For cementation

Page 11: Fluid management & Gingival Displacement

Contraindication

Should not be used with poly-vinylsiloxane as interferes with polymerization

Patients allergic to latex

Page 12: Fluid management & Gingival Displacement

Advantages

Isolate one/more teeth

Eliminates saliva from operating site

Retracts soft tissue

Page 13: Fluid management & Gingival Displacement

Disadvantages Time consuming and patients objection

Unusual tooth shapes or positions that cause inadequate clamp placement

Partially erupted teeth Broken down teeth

Patients suffering from asthma

Page 14: Fluid management & Gingival Displacement

High volume vacuum

Powerful suction device, use of 10mm diameter HVE tips, and a properly functioning suction pump set to evacuate one liter per minute of fluid

Uses Apparatus also removes small operatory debris Excellent lip retractor

Disadvantages Cannot be used for impression & cementation procedure

Page 15: Fluid management & Gingival Displacement

HIGH VOLUME VACUUM SUCTION

Page 16: Fluid management & Gingival Displacement

Saliva ejector• Low volume suction devices• 300 ml/ min is the suction rate• Adjunct to high volume vacuum/ rubber dam/cotton

rolls Uses Removes saliva from the floor of mouth Removes water slowly

Page 17: Fluid management & Gingival Displacement

Suction tips/ saliva ejectors

Disposable saliva ejectors - Transparent [ plastic] - Multi coloured [ plastic] - Hygoformic saliva ejector - Mirror vac - Lingua fix

Page 18: Fluid management & Gingival Displacement

SVEDOPTER It is used for isolating mandibular teeth It is a metal saliva ejector attached with a

tongue deflector

Page 19: Fluid management & Gingival Displacement

DISADVANTAGES -

Access to the lingual surface of mandibular teeth is limited

Cannot be used when mandibular tori prevents its use.

It may injure the soft tissues.

Page 20: Fluid management & Gingival Displacement

Commonest and cheap

Preparation in maxillary arch & mandibular arch

Cotton rolls

Page 21: Fluid management & Gingival Displacement

Controls small amounts of moisture and retracts cheek and tongue

Keeps its shape and does not fall apart when full of saliva

Provides acceptable dryness for procedures Cementation Impression making

Uses

Page 22: Fluid management & Gingival Displacement

Absorbents Useful for short period of isolation

Alternatives when rubber dam application is impractical

Retracts cheek & provide absorbency

Page 23: Fluid management & Gingival Displacement

CHEMICAL METHODS OF FLUID CONTROL

ANTI-SIALOGOUGES

LOCAL ANASTHETICS

CLONIDINE (ANTI-HYPERTENSIVE DRUG)

Page 24: Fluid management & Gingival Displacement

ANTI-SIALOGOGUES Controls salivary flow

They are gastrointestinal anti-cholinergics that inhibit the action of myoepithelial cells in salivary glands, producing dry mouth.

These drugs inhibit parasympathetic inervation and thereby reduce secretions, including saliva.

This group of drugs includes –atropine, dicyclomine, and methantheline.

Page 25: Fluid management & Gingival Displacement

CONTRAINDICATIONS –

-Patient with heart disease Asthma, obstructive conditions of

congestive heart failure.etc -Glaucoma,

because they can cause permanent blindness.

Page 26: Fluid management & Gingival Displacement

COMMONLY USED ANTI-SIALOGOGUES

Methantheline bromide (banthine) : 50 mg 1 hour before procedure

Propantheline bromide (pro-banthine) : 15 mg 1 hour before procedure

Clonidine hydrochloride (antihypertensive) :

0.2 mg 1 hour befor procedure

Page 27: Fluid management & Gingival Displacement

LOCAL ANESTHETICS

In addition to pain control normally needed during tissue displacement, local anesthesia may help considerably with saliva control during impression making.

Nerve impulse from periodontal ligament form part of the mechanism that regulates salivary flow, when these are blocked by anesthetics , saliva production is considerably reduced.

Local anesthetics drugs are Lignocaine, lidocaine, bupivacaine etc.

Page 28: Fluid management & Gingival Displacement

CLONIDINE (ANTI-HYPERTENSIVE)

It is considered safer than anticholinergics and has no specified contraindications.

However it should be used cautiously in patients who take hypertention medication.

In clinical trial, 0.2 mg of clonidine reduced salivary flow as effectively as 50mg of methantheline.

Page 29: Fluid management & Gingival Displacement

GINGIVAL RETRACTION

Page 30: Fluid management & Gingival Displacement

Definition

Gingival Retraction is the deflection of the marginal gingiva away from a tooth.

Gingival retraction is a process of exposing margins when making impression of prepared teeth.

Page 31: Fluid management & Gingival Displacement

Need of gingival displacement

• For accurate impressions in case of finish line at or below the gingival sulcus.

• For restoration of cervical lesions

Page 32: Fluid management & Gingival Displacement

FINISH LINE EXPOSURE

Finish line

The peripheral extension of a tooth preparation / or

The planned junction of two materials / or

The terminal portion of prepared tooth

It is a line of demarcation / or

Page 33: Fluid management & Gingival Displacement

IMPORTANCE OF FINISH LINE EXPOSURE

The gingival tissue must be healthy & free of inflammation before cast restorations are fabricated

The finish line must be reproduced in the impression.The marginal fit is very important in preventing recurrent caries and gingival inflammation (marginal intergrity)

Hence the finish line should be temporarily exposed to reproduce entire preparation.

Page 34: Fluid management & Gingival Displacement

Classification of gingival tissue displacement

Non-surgical Surgical

Mechanical Mechano-chemical

Page 35: Fluid management & Gingival Displacement

MECHANICAL METHODS

Commonly used mechanical methods of gingival retraction are :Copper bandRetraction cordRubber dam

Page 36: Fluid management & Gingival Displacement

COPPER BAND Copper band is a welded tube corresponding to

the size of the prepared tooth.

It is used to carry the impression as well as to displace the gingiva to expose the finish line.

Impression compound or elastometric impression materials can be used along with this band.

Disadvantage -Causes injury to the gingival tissues

Page 37: Fluid management & Gingival Displacement

TECHNIQUE

Page 38: Fluid management & Gingival Displacement

Gingival retraction cords

Gingival retraction cord is a tapered diameter cord that can be wrapped several times about a tooth that causes flared gingival crevice.

Plain cord provides mechanical retraction

Gingival retraction using chemically impregnated retraction cord is a mechanico-chemical method of displacement

Page 39: Fluid management & Gingival Displacement

Classification of retraction cords

Depending on the configuration TwistedKnittedBraided

Depending on surface finishWax Unwaxed

Page 40: Fluid management & Gingival Displacement

Depending on the chemical treatmentPlain Impregnated

Depending on number strandsSingle Double-string

Page 41: Fluid management & Gingival Displacement

They are available in a variety of configurations to provide for different diameters.

Fig : Braided type retraction cord Fig : Non-braided type or knitted type retraction cord

Page 42: Fluid management & Gingival Displacement

DESIRABLE QUALITIES OF CORD- Dark color to maximize contrast with

tissues, tooth & cord. Absorbent to allow for uptake of wet

medicament. Available in different diameters to

accommodate varying morphologies of gingival sulcus.

Page 43: Fluid management & Gingival Displacement

CHEMICALS USED FOR GINGIVAL RERACTION

They are generally local vasoconstrictors which produce gingival shrinkage.

8 % racemic epinephrineAluminium chloride (AlCl3)Alum (aluminium potassium sulphate)Alumminium sulphate Ferric sulphate (Fe2(SO4)3)

(Alluminium Chloride and Ferric sulphate are most commonly used because of its minimal tissue damage.)

Page 44: Fluid management & Gingival Displacement

CONTRAINDICATIONS OF EPINEPHRINE

It is contraindicated in patient with-

CVS Disease Hypertension Diabetes Hyperthyroidism Known hypersensitivity to Epinephrine.

Page 45: Fluid management & Gingival Displacement

IDEAL REQUIREMENTS OF CHEMICAL USED WITH GINGIVAL RETRACTION CORDS :-

It should produce effective gingival displacement and haemostasis.

It should not produce any irreversible damage to the gingival.

It should not have any systemic side effects.

Page 46: Fluid management & Gingival Displacement

Single cord technique.

Double cord technique.

Infusion technique of gingival displacement.

Every other tooth technique.

Techniques of gingival retraction

Page 47: Fluid management & Gingival Displacement

STEP-BY-STEP PROCEDURE. (DOUBLE CORD TECHNIQUE )

1. Isolate the prepared teeth with cotton rolls, place saliva evacuators as required, and dry the field with air. Loop the cord.

2. Cut a length of cord sufficient to encircle the tooth. Do not over-

desiccate the tooth, because this may lead to postoperative sensitivity.(Cord is left in the sulcus during impression making. – single cord technique)

Page 48: Fluid management & Gingival Displacement

0

Page 49: Fluid management & Gingival Displacement

7. Preparation is dried and impression is made with primary cord in place.

8. After impression making, small diameter cord is soaked in water and removed from the sulcus.

Page 50: Fluid management & Gingival Displacement

RETRACTION CORD PACKERS

Page 51: Fluid management & Gingival Displacement

CLINICAL TIP : If bleeding is persistent when the first cord is

removed, continue with the impression making certain to syringe the impression material within the sulcus. Even with the expectation that the impression will be unsuccessful. This impression will maintain the retraction while allowing for hemostasis. Remove the first impression and DO NOT look at it. Immediately make a second impression. The sulcus will still be open and will not be bleeding.

-(According to Dr Howard Strassler, Professor, University of Maryland Dental School )

Page 52: Fluid management & Gingival Displacement

# It is best to start in the interproximal area , because the cord can be more easily placed here than facially or lingually.

# The instrument should be angled toward the tooth so the cord is pushed directly into the area.

# It should also be angled slightly toward any cord already packed; otherwise, that portion might be displaced.

NOTE: Overpacking should be avoided because it could cause tearing of the gingival attachment, leading to irreversible recession. Repeated use of displacement cord in the sulcus also should be avoided, since this can cause gingival recession.

Page 53: Fluid management & Gingival Displacement

Infusion technique

Indication Controls hemorrhage

Procedure

Retraction cord packed into the sulcus for 1-3 minutes.

Infuser used with a burnishing motion in the sulcus circumferentially 360° around the sulcus

Page 54: Fluid management & Gingival Displacement

Every other tooth technique

Anterior tooth preparation when the roots are in proximity

Prevents collapse of gingival papilla.

Page 55: Fluid management & Gingival Displacement

SURGICAL METHOD

Page 56: Fluid management & Gingival Displacement

ROTARY CURETTAGE (GINGETTAGE)

It is a troughing technique , wherein a portion of the epithelium within the sulcus is removed to expose the finish line.

It should be done only on the healthy gingival tissue

Page 57: Fluid management & Gingival Displacement

Criteria for rotary curettage

Done on healthy and inflammation free tissue to prevent tissue shrinkage

Absence of bleeding on probing

Sulcus depth less than 3.0 mm

Presence of adequate keratinized gingiva

Page 58: Fluid management & Gingival Displacement

TechniqueShoulder finish line preparation prepared at

gingival crest using flat end tapered diamond

Finish line extended apically1/2-2/3 the depth of the sulcus by torpedo diamond

Aluminum chloride impregnated retraction cord placed in sulcus

Cord removed after 4-8 minutes

Page 59: Fluid management & Gingival Displacement

Shoulder prepared at the gingival level

Torpedo diamond bur to form chamfer finish line and removal

of epithelial sulcus

Cord placed in the troughed sulcus

Page 60: Fluid management & Gingival Displacement

DISADVANTAGES OF GINGETTAGE

Instrument has poor tactile sense so this technique is very sensitive.

It can potentially damage the periodontium .

Page 61: Fluid management & Gingival Displacement

ELECTROSURGERY The procedure is called surgical diathermy or

Electrosurgical retraction

It is the surgical retraction of the sulcular epithelium using an electrode to produce gingival retraction

The inner epithelial lining of gingival sulcus is removed, thus improving access for a subgingival crown margin and effectively controlling post surgical hemorrhage (provided the tissue are not inflamed).

Page 62: Fluid management & Gingival Displacement

An electrosurgery unit works by passage of a high frequency current (1 to 4 million Hz) through the tissue from the large electrode to a small one. At the small electrode , the current induces rapid localized polarity changes that cause cell breakdown.

For restorative procedure, an unmodulated alternating current (AC) is recommended, because it will minimize damage to deeper tissue.

Page 63: Fluid management & Gingival Displacement

INDICATIONS -

Areas of inflammation in gingival tissue where the retraction cord cannot be used

Gingival proliferation around the prepared finish line

Page 64: Fluid management & Gingival Displacement

CONTRAINDICATIONS -1. Patients with cardiac pacemakers or patients

with any electronic medical devices.2. Use of topical anesthesia such as ethylchloride

and other inflammable aerosols should be avoided when electrosurgery is to be used.

3. Not suitable on thin attached gingivae (e.g labial tissue of maxillary canines)

Page 65: Fluid management & Gingival Displacement

ADVANTAGES –

1) Sophisticated technique.2) Can be done in cases with gingival

inflammation.3) Produces little to no bleeding.4) Quick procedure.

Page 66: Fluid management & Gingival Displacement

DISADVANTAGES –1. Very technique sensitive2. Application of excessive pressure may produce

severe tissue damage.3. Difficult to control lateral dissipation of heat.4. It cannot be done in a dry field. The operatory

area should be very moist during the procedure. This leads to compromised access and visibility.

Page 67: Fluid management & Gingival Displacement

ELECTROSURGICAL UNIT (ESU)

Specially designed electrosurgical units are available for gingival reduction.

The major uses of these electrodes include :

Gingival sulcus enlargement. Crown lengthening. Removal of edentulous cuff.

Page 68: Fluid management & Gingival Displacement

The unit has knobs to alter the frequency and the flow of current.

Two electrodes can be attached to each unit. One is surgical electrode and the other is the ground electrode or ground plate.

Page 69: Fluid management & Gingival Displacement

GROUND ELECTRODE : The ground plate should be placed under the thigh or the back of the patient. It is used to complete electrical circuit.

SURGICAL ELECTRODE or CUTTING ELECTRODE : It is similar to a probe, and is designed to produce intense heat during surgical procedures. This heat helps to vaporize the target tissue. It may be either straight or J-shaped.

Page 70: Fluid management & Gingival Displacement

MOST COMMON EDGE DESIGNS ARE – COAGULATING PROBE, DIAMOND LOOP, ROUND LOOP,

SMALL STRAIGHT PROBE, SMALL LOOP ,ETC.

Page 71: Fluid management & Gingival Displacement

MECHANISM OF ELECTROSURGERY

Page 72: Fluid management & Gingival Displacement

TECHNIQUE Basic principles to be followed during

Electrosurgical procedures: Local anaesthesia should be given. Proper power setting – Grounding should be

done before usage of electrode. Swift passage of electrode – During its use,

electrode should be applied with no pressure and swift strokes.

Page 73: Fluid management & Gingival Displacement

Rest interval between strokes – It should never be placed stagnant at one point

rather it should move very smooth ,

the probe should move at minimal speed of 7mm per second.

A rest period of 8-10 seconds should be allowed to elapse if second stroke is needed.

The electrode can be cleaned by wiping it with an alcohol-soaked sponge.

Page 74: Fluid management & Gingival Displacement

TECHNIQUE FOR GINGIVAL SULCUS ENLARGEMENT

A small (straight or J-shaped ) electrode is used.

The electrode should be positioned such that it is parallel to the long axis of the tooth.

The procedure is done in four motions namely – facial, mesial , lingual and distal.

Debris in the sulcus should be removed using a cotton pellet dipped in Hydrogen peroxide (H2O2).

Page 75: Fluid management & Gingival Displacement

TECHNIQUE FOR SURGICAL CROWN LENGTHENING

Removal of hyperplastic gingiva (gingivectomy) inorder to expose anatomical crown to increase accessibility.

It is done using a diamond electrode.

The diamond electrode is run over the tissues such that one of its surfaces follows the incline of the tooth where the procedure is carried out.

Page 76: Fluid management & Gingival Displacement

The bevel should be done on attached gingival to prevent re-growth.

If there is an extensive wound, a periodontal dressing should be given and should be changed weekly.

Page 77: Fluid management & Gingival Displacement

TECHNIQUE FOR REMOVAL OF EDENTULOUS CUFF

Edentulous cuff is a remnant of inter dental papilla.

Which is seen in the proximal sides of the adjacent edentulous space.

It is removed by using an electrosurgically by using loop electrode.

Page 78: Fluid management & Gingival Displacement

RECENT ADVANCES IN SOFT TISSUE MANAGEMENT

MAGIC FOAM CORD MEROCEL LASER EXPASYL RETRAC

Page 79: Fluid management & Gingival Displacement

MAGIC FOAM CORD

First expanding VPS material designed for easy and fast retraction of sulcus without potentially traumatic packing or Pressure.

Fig : Foam cord

Page 80: Fluid management & Gingival Displacement

TECHNIQUE -

a)Initial situation

b) Pre-fit the comprecap. C) Apply magic foam cord

D) Aplly magic foam e) Comprecap after remaval.

Page 81: Fluid management & Gingival Displacement

ADVANTAGES1. Not technique sensitive, flows directly into the

sulcus. 2. Easy to use.3. Atraumatic.4. Rinsing not required.5. More efficient in multiple preparations.

Disadvantage –-No hemostatic action

Page 82: Fluid management & Gingival Displacement

Merocel strips

Marco Ferrari et al in 1996 found Merocel Synthetic material that is biocompatible polymer

(hydroxylate polyvinyl acetate)

Page 83: Fluid management & Gingival Displacement

Mechanism of action

Expands by absorption of oral fluids and exerts pressure on surrounding tissue

Page 84: Fluid management & Gingival Displacement

Method

About 2 mm of merocel retraction strip

Provisional crown inserted

Maintain pressure on crown for 10-15 min

Page 85: Fluid management & Gingival Displacement

Advantages

Easily shaped and adapted around tooth

Highly effective in absorption of oral fluids

Chemically pure- no post surgical complications

Non abrasive

Page 86: Fluid management & Gingival Displacement

LasersIndication Controlled tissue removal before impression

making Tissue contouring

Properties of laser depends on Wavelength Waveform

Page 87: Fluid management & Gingival Displacement

Types of lasers

Neodymium: yttrium-aluminium-garnet

Erbium: yttrium- aluminum-garnet

Page 88: Fluid management & Gingival Displacement

Advantage

Minimum pain and discomfort Less fear ,anxiety and stress Minimum or no anesthesia No drill sounds Less chair time Reduced post operative complications Minimum or no bleeding

Disadvantage

Overuse causes shrinkage of tissue and also results in exposure of crown margin

Page 89: Fluid management & Gingival Displacement

Introduced by Satalec Pierre Rolland Cordless gingival retraction (SDS/Kerr Company)

Composition Aluminum chloride-15% astringent & hemostatic

agent Kaolin Excipients

Expasyl

Page 90: Fluid management & Gingival Displacement

Mechanism of action

It has both mechanical and chemical action

Aluminum chloride provides- hemostasis Viscosity of Kaolin- retracts the tissue

Recommended time of application-1-2 min

Page 91: Fluid management & Gingival Displacement

AdvantagesEffectively achieves hemostasis.

Effectively retracts gingival tissues

Less traumatic to tissues than cord packing.

Faster than traditional cord.

Easy removal from sulcus by rinsing.

Dispenser tips can bent- improves intraoral access.

Page 92: Fluid management & Gingival Displacement

DisadvantagesExpensive

Effective under limited conditions.

Disposable metal dispenser tips are too large causes difficulty to express

Thickness makes it difficult to express

Page 93: Fluid management & Gingival Displacement

NEW GINGIVAL RETRACTION AGENTS-(W.H.BOWLES, S.J.TARDY & A.VAHADI)

 

 A sympathomimetic amine containing eye drops and nasal decongestant have been shown to be effective in gingival retraction.

Tetrahydrazoline hCl 0.05% - (Visine)

Oxymetazoline hcl 0.05% - (Afrin)

Phenylephrine hcl 0.25% -(Neosynephrine)

Page 94: Fluid management & Gingival Displacement

Visine & afrin-produced -greater displacement than any other agents.(alum , racemic epinephrine & phenylephrine etc)

Visine produced :-50% greater tissue displacement-better control of crevicula seepage-no detectable side-effects

Neosynephrine–-is as effective as, epinephrine & alumin widening the gingival sulcus.

Page 95: Fluid management & Gingival Displacement

DISCUSSION

The choice of gingival retraction cord has proven itself to be one of personal preference by the clinician. Keep in mind that different cord types offer a variety of properties that to some make them more desirable

A 20-25% alluminium chloride and 15.5 – 20 % ferric sulfate are most popularly used chemical reagents. When used for durations within the gingival sulcus of less than 10mins, they cause minimal tissue damage.

Page 96: Fluid management & Gingival Displacement

Unfortunately , gingival bleeding is difficult to control when packing a cord into the sulcus, the tissue starts to bleed making impression difficult or impossible. For this reason a new class of gingival retraction material have been introduced. These cordless retraction materials eg. Expasyl ( Kerr), Racegel ( Septodont ) , Traxodent ( Premier ) etc provide for excellent hemostasis and some gingival retraction.

Page 97: Fluid management & Gingival Displacement

High viscosity hemostatic gel can be placed in the sulcus to both help with hemostasis and act as lubricant for atraumatic placement of gingival retraction cord and can be placed on the cord itself. For this case 25% alluminium sulfate hemostatic gel is used to impregnate and lubricate a knitted cord.

(According to Dr Howard Strassler,Professor, University of Maryland Dental School,)

Page 98: Fluid management & Gingival Displacement

CONCLUSION

Gingival displacement is an important procedure for fabricating indirect restoration especially when subgingival finish line is used. Proper management of tissues and fuilds around the prepared teeth is essential for making an excellent impression in a field free from capillary seepage. But before any procedure is attempted, the dentist should analyse for the best suited technique which would minimally harm the adjacent tissues.

Page 99: Fluid management & Gingival Displacement

BIBLIOGRAPHY Fundamentals of FIXED PROSTHODONTICS,

Herbert T. Shillinburg, David A. Sather, Edwin L. Wilson, Joseph R. Cain, Donald L. Mitchell, Luis J. Blanco, James C. Kessler

Text book of Prosthodontics by V Rangarajan & TV Padmanabhan

Page 100: Fluid management & Gingival Displacement

THANKS