FLT-06 User Manual - Progressive Automations · FLT-06 User Manual Page 2 Page 4 Page 5 Page 6...

6
FLT-06 User Manual Page 2 Page 4 Page 5 Page 6 Caution/Liability Technical Specifications Parts/Setup Operational/Reset Procedure, Troubleshooting Dimensions Page 3 Contents

Transcript of FLT-06 User Manual - Progressive Automations · FLT-06 User Manual Page 2 Page 4 Page 5 Page 6...

FLT-06 User Manual

Page 2

Page 4Page 5

Page 6

Caution/Liability Technical Specifications Parts/SetupOperational/Reset Procedure, Troubleshooting Dimensions

Page 3

Contents

Caution

Liability

2

Technical Specifications

3

Base Width 43” min. - 72.4” max.

Duty Cycle 10% Max. 2 mins on, 18 mins off

Height Range 23.5” - 49” (without table top)

Minimum Table Top Size 43"x 24”

Weight Capacity 350 lbs (175 lbs Per Leg)

Features Soft start/stop, adjustable leveling studs & 4 memory presets

Input Voltage 120 VAC, 60 Hz

Output Voltage 24 VDC

Stroke 25"

Speed 1.30"/sec

Material Steel

Certification UL

Parts

4

Lifting Columns x 2 Control Box & Remote

AC Power Cord

Connector Cables x 2

FLT-06 CONTROL BOX

F

HS

M2AC

M1

110/240VAC

WIRED REMOTE

FLT-06LIFTING COLUMN [M1]

FLT-06LIFTING COLUMN [M2]

Setup

5

Reset Procedure

Operational ProcedureOnce your lifting columns are installed, operation is simple. Using the wired remote will allow full control over extending and retracting the lift columns. Use the up button to raise the columns and the down button to lower the columns.

You can program up to 4 locations using the memory setup: Use the up/down buttons on the remote to find your desired height(s), then press “M” followed by a number 1-4. The column height positions are now saved. To move to the set position, hold the number button.

IMPORTANTYou must reset the lifting columns prior to use:

To reset, press and hold the DOWN button on the Hand Remote (7) until the lifting columns reach their lowest point. Release the DOWN button. Press and hold the DOWN button again until the LED display shows "RST". If you are not using an LED hand remote hold it for about 10 seconds. Release the DOWN button. Finally press and hold the DOWN button once more until the columns lower, slightly rises then stops. This signals the end of the reset procedure. Release the DOWN button and your lifting columns are now ready to use.

TroubleshootingIf your columns are not functioning it might need to be reset. Follow the RESET procedure.

If your hand remote has an LED display and it displays "RST" (reset), perform the reset procedure.

If the LED displays shows an error message ("Er1" - "Er13"), confirm that all wired connections are secure. Then perform the reset procedure.

If the LED remote displays "HOT", let the unit cool down for 20 minutes.

If the error message persists after the reset procedure, contact us at 1-800-676-6123 or [email protected].

Dimensions

6

Remote

Control Box

Legs3.2"

2.0"

22.0"

2.0" 3.2"

M8X10

2.5"1.6"

0.6"

0.6"

7.6"

2.0"

3.8"

2.8"

0.4"

6.6"

M6X10

M6X10

AC

F H

SM

2

10.1"

0.1"

0.3"

3.5"

1.6"

3.5"

0.7"

AC

M2F HS

M1

M1

M3

4

2

1˄ ˅

5.7"

3.3"

2.0"

3.4"

2.2"

1.4" 0.2"