SEMINAR REPORTANALYSIS OF FLOW CONTROLS IN Y-DUCT DEFFUSER
NITHIN HEGDE
2011FE12
DEPARTMENT OF APPLIED MECHANICS
MOTI LAL NEHRU NATIONAL INSTITUTE OF
TECHNOLOGY, ALLAHABAD
-
7/31/2019 Flow Control in Y-Duct
2/24
CFDANALYSIS OFFLOWCONTROLSINY-DUCTDIFFUSER
INTRODUCTION
Aircraft propulsion systems often use Y-shaped subsonic diffusing duct as air-
intakes to supply the ambient air into the engine compressor to compress the air, so
the thrust generation. For many military applications the inlet geometry isimportant for stealth requirement.A serpentine inlet can be used to hide the line ofsight to the compressor face in order to reduce the infra-red signature.
Source of losses in intake diffuser:
Losses due to Friction on the walls of the duct.
Flow separation due to adverse pressure gradient as well as due bends. Flow separation causes total pressure distortion, this cause flow non-
uniformity at compressor inlet so the asymmetric loading on compressor
blade.
The distortion is a significant cause of premature engine surge.Major separation control techniques used in intake diffuser:
Tangential blowing to directly energize the low momentum region near thewall.
Wall suction to remove low momentum region. Vortex generator (VG) in the form of vanes. Forced excitation devices.
1st
and 2nd
are very effective in controlling separation. However, these strategies
requires a high mass flux source, thus they are rarely used.
In VG produces strong vortices which enhance the mixing between high
momentum core flow and low momentum boundary layer flow, thus energizing the
boundary layer flow.
-
7/31/2019 Flow Control in Y-Duct
3/24
Most of single engine military aircrafts consists of a Y-shaped twin air-
intake duct, which is mounted on either sides of the fuselage and carries
atmospheric air in to the compressor. The air intake of the aircraft supplies the
mass flow demand of the engine over a range of aircraft speeds and altitudes with
high pressure recovery and at minimum flow distortion. Due to space constraint,the diffusers need to be curved, which causes severe flow non-uniformity at the
engine face and separation on the curved surface causes flow distortion. Total
pressure distortion at the engine face is one of the parameters that contribute to
intake losses (Seddon and Goldsmith, 1995). The distortion causes premature
engine surge and flow non-uniformity which may cause range of undesirable
effects including asymmetric loading of the compressor blades.
OBJECTIVE
The present study attempt to control flow in a mild-curved Y-duct diffuser
using trapezoidal-shaped submerged co-rotating vortex generator (VG) attached on
the top and bottom surface of inflection plane.
Which ensures duct with co-rotating VG higher static pressure recovery, lower
total pressure loss, minimum flow distortion and less flow non-uniformity as
compared to bare Y-duct diffuser.
Geometry:
Bare duct:
Y-duct diffuser with 20turning angle (plane-B). Straight length of 75mm is added to outlet for proper boundary layer growth. Inlet area of diffuser was chosen as 75*75 mm2 (plane-A&F). The duct is tapered to an outlet width of 200mm (plane-D). The area ratio for the Y-duct is 1.33.
-
7/31/2019 Flow Control in Y-Duct
4/24
Geometry of Y-duct with co-rotating VG at top and bottom surface at inflexion
plane:
Type h1 (mm) h2 (mm) L (mm) l (mm)
Co-VG 13.5 2.0 4.0 11.0 10.7
Top view of Y-duct
diffuser
Isometric view of Y-
duct diffuser
Schematic diagram of VG
-
7/31/2019 Flow Control in Y-Duct
5/24
Grid generation:
Grid Independency test:
Sl. No. No. of GridElements
Csp Total CPU Time
1 60984 0.1313053 1hr. 30min.
2 108000 0.127469 2hr. 15min.
3 164052 0.124053 2hr. 30min
4 239250 0.122255 3hr
5 261120 0.121075 3hr 20min
6 493848 0.121018 4 hr. 15min
CPU CAPACITY: 2.2GHz DUAL CORE PROCESSORS WITH 4GB RAM.
Isometric view of Y-duct with
counter rotating VG
-
7/31/2019 Flow Control in Y-Duct
6/24
Skewness test:
1. For bare Duct:
Hexahedral meshing is done on whole domain. Total 261120 elements are crated. Boundary layer is created near the wall to capture near wall effects. Boundary conditions are given as;
o Velocity inlet at plane A and F.o Pressure outlet,o Planes B, C, D, E are interiors.o And remaining walls.
-
7/31/2019 Flow Control in Y-Duct
7/24
2. Duct with Co-rotating VG:
Mesh Quality:
Applying quality criteria for hexahedra cells.
Maximum cell squish = 6.07381e-001
Maximum aspect ratio = 6.23260e+00
Solver: For validation of result RNG k- turbulence model is used. In this model
transport equation solved for turbulent Kinetic energy (k) and rate of
dissipation (). This model is derived from instantaneous Navier-stokes
equations, using a mathematical technique called renormalization group
(RNG) method. The effect of swirl on turbulence is included in the RNG
model, so enhancing accuracy for swirling flows.
Transport equations for RNG - model:
Where:
-
7/31/2019 Flow Control in Y-Duct
8/24
o Gk and Gb are generation of turbulent K.E. due to mean velocitygradients and buoyancy resp.
o YM is represents the contribution of the fluctuating dilatation incompressible turbulence to the overall dissipation rate.
o k and are the inverse effective Prandtl numbers for and kresp.
o S and S are user-defined source terms for and k resp.
Enhanced wall treatment method is used to account for boundary layersformed during grid generation.
Second order upwind discretization scheme is employed. For pressure and velocity coupling, SIMPLE (semi-implicit method for
pressure linked equations) scheme is employed.
Convergence criteria are set as 10-5 for all solutions. No-slip condition is set for duct walls.
Boundary conditions:
Turbulent kinetic energy k =1.5*(Uavi * I)2,
Turbulence dissipation rate = (C3/4
k3/2
)/L
Where;
L=turbulence length scale=0.07*Lc,
Lc=characteristic length,
I = turbulent intensity = 0.16 (Re)-1/8
,
C = turbulent model constant.
-
7/31/2019 Flow Control in Y-Duct
9/24
Velocity inlet conditions;
Velocity profile is given at inlet.
Re=1.009526*105, Lc =0.075m, C =0.0845.
I=0.037897,
k =0.83283 m2/s
2,
= 22.689 m2/s
3.
Pressure outlet conditions;
Zero gauge pressure is set at exit condition.
Lc =0.2m, C =0.0845.
I=0.037897, k =0.83283 m2/s
2, = 8.5084 m
2/s
3.
Residual curve:
-
7/31/2019 Flow Control in Y-Duct
10/24
Contour plots:
1. Contour of total pressure at plane-D:
Without VG
With VG
-
7/31/2019 Flow Control in Y-Duct
11/24
2. Static pressure contour at mid-plane of Y-duct diffuser:
3. Contour of velocity magnitude at mid-plane of the Y-duct diffuser:
Without VG With Co-VG
Without VG With Co-VG
-
7/31/2019 Flow Control in Y-Duct
12/24
Results and Discussion:
1. Static pressure recovery coefficient(CPR ):It is described as the ratio of rise in average static pressure with respect to
the inlet to the average dynamic pressure at inlet.
i.e.
CPR = (PSPSi)/(0.5Uavi2)
Where, PS and Psi are the static pressure at any point and at inlet respectively.
2. Total pressure loss coefficient (CPR) :It is defined as ratio of total pressure loss with respect to the inlet to the
average dynamic pressure at inlet.
i.e.
CTL = (PtiPt)/(0.5Uavi2)
Where, Pti and Pt are total pressure at inlet and at any point.
Validation of CPR and CTL for bare duct:
-
7/31/2019 Flow Control in Y-Duct
13/24
* A.R Paul, P Ranjan, R.R upadhyay, A jain. Flow control in Y-shaped air-intakes using vortex generators.37th National & 4
thInternational conference on fluid mechanics and fluid power
Comparison of CPR and CTL for duct with co-rotating VG on top and
bottom surface of the wall and Bare duct:
Static pressure recovery is improved in case of diffuser with co-rotating VGas compared to bare duct.
It is noted that total pressure loss coefficient CTL variation is less in case ofVG attached on top and bottom walls.
3.Secondary flow Non-uniformity (Sio):The non-uniformity index (Sio) at duct outlet (plane-D) i.e.
Aerodynamic Inlet Plane (AIP) can be defined as the average of
the sum of secondary velocities (Uyz in y-z plane), non-
dimensionalized by dividing by the average velocity at the inlet.
CTL
-
7/31/2019 Flow Control in Y-Duct
14/24
i.e.
where, Uyz=2 2
( )y z
u u , n=number of computed data point.
Uavi=19.67m/s=average velocity at the duct inlet.
o Below data is calculated by taking the data of velocities at y and z directionin plane-D.
Bare duct;Sum (Uyz) = 732.7766203,
n = 3360,
Uavi=19.67 m/s.
i.e.Sio = 732.7766203/(3360*19.67)
Sio = 0.011087355.
Duct with co-VG:Sum (Uyz) = 596.1312887,
n = 2520,
Uavi=19.67 m/s.
i.e.Sio = 596.1312887/(2520*19.67)
Sio = 0.0120264.
Validation of Sio:My result Paper result
*
Bare duct Co-vg Bare duct Co-vg
0.01108 0.012026 0.010 0.011
From above table it is noted that S io value records only a slight increase incase of VG.
Sio=
-
7/31/2019 Flow Control in Y-Duct
15/24
* A.R Paul, P Ranjan, R.R upadhyay, A jain. Flow control in Y-shaped air-intakes using vortexgenerators.37
thNational & 4
thInternational conference on fluid mechanics and fluid power.
4. Axial flow Non-uniformity:It is the mean standard deviation in the axial velocity measured at a cross-
plane of air-intake and is expressed as,
Where,
Ux is the longitudinal velocity, Uxav is the average of longitudinal velocity and n is
the number of computed data points.
o Below data is calculated by taking the x-velocity component at plane-D. Bare duct:
Uxav=8.7684927,
(Sum (Ux-Uxav))2
= 117093.8112,
n=3360,=(117093.8112/3360)
0.5
= 5.903333
Duct with co-vg:Uxav = 10.97623351,
(Sum (Ux-Uxav))2
= 77044.24644,
n=2520
=(77044.24644/2520)0.5
= 5.5292959.
From above it is noted that, axial flow non-uniformity( ) is decreases incase co-rotating VG attached on top and bottom surface of the duct as
compared to bare duct.
-
7/31/2019 Flow Control in Y-Duct
16/24
Validation of axial flow non-uniformity( ):My result Paper result
Bare duct Duct with Co-vg Bare duct Duct with Co-vg
5.903 5.529 5.420 5.208
* A.R Paul, P Ranjan, R.R upadhyay, A jain. Flow control in Y-shaped air-intakes using vortex generators.37th National & 4
thInternational conference on fluid mechanics and fluid power.
5.Momentum thickness ():Momentum thickness () value is an indicative of momentum deficit in the
boundary layer. This deficit increase the chances of the flow separation in y-
duct diffusers.
Calculations:o For bare duct:
Velocity profile at plane-D along y-axis line
-
7/31/2019 Flow Control in Y-Duct
17/24
Boundary layer thickness =0.021104mm
Then, momentum thickness () = (2/15)*
i.e.
=2.813867mm
o For duct with co-vg:
Boundary layer thickness =0.02004mm
Then, momentum thickness () = (2/15)*
i.e.
=2.672mm
Velocity profile at plane-D along y-axis line
-
7/31/2019 Flow Control in Y-Duct
18/24
Validation of momentum thickness ():My result Paper result
Bare duct Duct with co-vg Bare duct Duct with co-vg
2.814 2.672 2.60 2.48
6. Distortion pressure coefficient (DC60):Since the total pressure distortion causes surge or buzz at the exitof the y-duct and is responsible for the intake losses. This
phenomenon leads to a range of undesirable effects including
asymmetric loading of the compressor blades.
The distortion is designed in terms of distortion coefficient (DC60) in worst
600
sectors.
i.e.
Where Pte is the total at the duct exit (plane-D) and P60 represents
the total pressure at the duct exit.
DC60 = (PteP60)/(0.5Uavi2)
-
7/31/2019 Flow Control in Y-Duct
19/24
Bare duct total pressure contour map at exit plane-D
Worst 600 sector:
Avg. total pressure at exit plane-D = 103.42638 pa
Avg. total pressure at worst 600
sector at exit = 41.15 pa
Now,
DC60 = (103.42638-41.15)/(0.5*1.225*19.672)
DC60 = 0.2627898
-
7/31/2019 Flow Control in Y-Duct
20/24
For duct with co-VGtotal pressure contour map at exit plane-D:
At worst 600 sector:
Avg. total pressure at exit plane-D = 101.26767 pa
Avg. total pressure at worst 600
sector at exit = 45.62256 pa
Now,
DC60 = (101.26767-45.62256)/(0.5*1.225*19.672)
DC60 = 0.2348
-
7/31/2019 Flow Control in Y-Duct
21/24
The use of VG on the inner surface of the duct promotes better mixing oftwo flow fields and results in decrease in DC60 values in the Y-duct diffuser.
Validation of DC60:
My result Paper result
Bare duct Duct with co-vg Bare duct Duct with co-vg
0.2627898 0.2348 0.259 0.223
Boundary layer at inflexion plane:
u= 0.99*Uavg = 0.99*19.5
u = 19.305m/s,
Boundary layer thickness =4.448mm
Hence height of VG used less than 4.448 mm, therefore we can say that
VG used is submerged vortex generator type (SVG).
-
7/31/2019 Flow Control in Y-Duct
22/24
Summary of results:
Type
Bare ductCo-VG at top and bottom
surface of the duct
My
result
paper
result% error My
result
paper
result% error
DC60 0.263 0.259 1.52 0.2348 0.223 5.02
Sio 0.01108 0.010 9.74 0.01203 0.011 8.56
5.903 5.420 8.18 5.53 5.208 5.82
2.814 2.60 7.6 2.672 2.48 7.18
Conclusion:
VG attached to top and bottom walls of the Y-duct diffuser have aneffect on flow uniformity at its outlet.
It is noted that axial flow non-uniformity( ) is decreases in caseco-rotating VG attached on top and bottom surface of the duct as
compared to bare duct.
Static pressure recovery is improved in case of diffuser with co-rotating VG as compared to bare duct.
Momentum thickness is decreases in case co-rotating VG attachedon top and bottom surface of the duct as compared to bare duct,
which indicates delay in flow separation.
Attaching the VG distortion at the exit of the duct is decreases ascompared to bare duct.
-
7/31/2019 Flow Control in Y-Duct
23/24
REFERRENCES:
1. A.R Paul, P Ranjan, R.R upadhyay, A jain. Flow control in Y-shaped air-intakes using vortex generators.37
thNational & 4
thInternational conference
on fluid mechanics and fluid power December 16-18, 2010, IIT Madras,
Chennai, India.
2. Control of Compressor Face Total Pressure Distortion on a High BypassTurbofan Intake using Air-Jet Vortex Generators. S.D. Erbsloh and Dr. W.J.
Crowther The University of Manchester, Manchester, UK, M13 9PL J.R.Frutos FEMTO-ST Institute, LPMO Department, 25044 Besanon, France.
3. Ansys Fluent 12.0 theory guide, April 2009.4. Flow Control Analysis of S-duct Diffuser Inlet. Lian.Xiaochun Zhang.Lifen
Wu.Dingyi School of Power and Energy, Northwestern PolytechnicalUniversity, Shaanxi 710072.5. Flow Improvement in Rectangular Air Intake by Submerged Vortex
Generators. A.R. Paul, K. Kuppa, M.S. Yadav and U. Dutta,Journal ofAppliedFluidMechanics, Vol. 4, No. 2, Issue 1, pp. 77-86, 2011.
-
7/31/2019 Flow Control in Y-Duct
24/24