FLOOR PLAN - s3. · PDF filearchitectural floor plan 2 3 plan symbols floor plan 1 ALIGN ROOM...

1
BREAK ROOM: 140 SF W/S: 25 102 SF W/S: 24 102 SF W/S: 23 102 SF W/S: 22 117 SF W/S: 21 106 SF W/S: 20 102 SF W/S: 19 105 SF W/S: 41 122 SF W/S: 47 117 SF W/S: 49 113 SF W/S: 50 102 SF W/S: 18 101 SF W/S: 17 104 SF W/S: 16 109 SF W/S: 14 116 SF W/S: 13 105 SF W/S: 12 153 SF W/S: 11 113 SF W/S: 8 113 SF W/S: 7 111 SF W/S: 4 110 SF W/S: 3 111 SF W/S: 1 106 SF W/S: 10 107 SF W/S: 9 102 SF W/S: 6 100 SF W/S: 5 102 SF W/S: 2 112 SF OFFICE: 80 SF W/S: 15 129 SF W/S: 51 119 SF W/S: 48 115 SF W/S: 46 119 SF W/S: 36 112 SF W/S: 45 163 SF W/S: 44 143 SF W/S: 43 101 SF W/S: 42 100 SF W/S: 40 101 SF W/S: 38 96 SF W/S: 35 96 SF W/S: 34 104 SF W/S: 33 101 SF W/S: 32 104 SF W/S: 31 96 SF W/S: 30 96 SF W/S: 29 101 SF W/S: 28 101 SF W/S: 27 97 SF W/S: 26 97 SF MEN: 96 SF WOMEN: STG: 35 SF VEND LIMIT OF CONSTRUCTION LIFT W/S: 37 118 SF W/S: 39 124 SF FEC FEC FEC EXIT 4'-6" AFF 4'-0" AFF 6'-8" MIN. TO UNIT BOTTOM FIN. FLOOR 3'-4" AFF 1'-6" AFF L C L C L C L C 8" L C VARIES NOTE: WHEN VARIOUS COMPONENTS OCCUR ON THE SAME WALL, ALIGN AS SHOWN. CLG. HEIGHT 6" L C L C BASE CABINET 4" BACKSPLASH TYP. OUTLET @COUNTER TOP THERMOSTAT PULL BOX TYP. SWITCH SCHEDULED HARDWARE TYP. ELEC., TELE. OR COMP. OUTLET STROBE and/or HORN REFER TO GENERAL NOTES SHEET G0.0 FOR GENERAL CONDITIONS AND REQUIREMENTS FOR ALL CONSTRUCTION. CONTRACTOR TO PERFORM THE WORK OUTLINED IN THESE NOTES IN ALL AREAS OF CONSTRUCTION UNLESS NOTED OTHERWISE: ALL DIMENSIONS ARE FROM FACE OF FINISH TO FACE OF FINISH UNLESS NOTED OTHERWISE. CONTRACTOR SHALL COORDINATE STUD SIZE AND GAGE NECESSARY FOR HEIGHT OF WALL, AS WELL AS FOR STRUCTURAL, MECHANICAL, PLUMBING, OR ELECTRICAL CLEARANCES PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES WITH LAYOUT AS DIMENSIONED SHALL BE COORDINATED IMMEDIATELY WITH ARCHITECT. IN FIRE RATED WALLS CONTRACTOR SHALL REINFORCE METAL STUD CONSTRUCTION WITH FIRE RESISTANT WOOD BLOCKING AT ALL LOCATIONS WHERE WALL CABINETS, SHELVING, GRAB BARS, ACCESSORIES, SIGNS, ETC., ARE TO BE INSTALLED. AT ALL OTHER WALL TYPES NON-FIRE RESISTANT WOOD BLOCKING IS ACCEPTABLE AT THESE INSTALLATIONS. DOORS TO BE INSTALLED WITH JAMB SIDE 6" FROM INTERIOR FACE OF PERPENDICULAR WALL UNLESS NOTED OTHERWISE. CONSTRUCT GYPSUM BOARD COLUMN WRAP WITH 7/8" HAT CHANNELS OR 2-1/2" STUDS AND 5/8" GYPSUM WALLBOARD. MINIMIZE OUTSIDE DIMENSION OF COLUMN ENCLOSURE. INCORPORATE ANY ADJACENT PIPING OR ELECTRICAL DEVICES. IF COLUMN WRAPS ARE LESS THAN 6" FROM ADJACENT WALLS, EXTEND GYPSUM ENCLOSURE TO INTERSECT WALL. A1.1 FLOOR PLAN 1 CONTRACTOR SHALL PERFORM THE WORK INDICATED BY THESE NOTES IN AREAS DESIGNATED ON THE PLAN SPECIFIC KEYNOTE NUMBER. key notes architectural floor plan 2 3 plan symbols floor plan 1 ALIGN ROOM NAME & NUMBER KEYNOTE ELEVATION TAG: ELEVATION REFERENCE SHEET REFERENCE ALIGN FINISHED FACE OF PARTITION WITH SURFACES INDICATED PARTITION CONSTRUCTION TYPE, SEE "PARTITION TYPES" BELOW. DOOR TYPE, RE: DOOR SCHEDULE & LEGEND. HARDWARE TYPE, RE: HARDWARE LEGEND. CORE DRILL LOCATIONS (UPPER FLOORS) OR TRENCH STUB UP (FIRST FLOOR) ARE SHOWN FOR DESIGN INTENT ONLY. DIMENSIONS ARE TO CENTER LINE OF CORE DRILL/STUB UP. COORDINATE WITH ELECTRICAL DRAWINGS FOR DEVICE SELECTION. NAME # plan symbols floor plan A5.1 1 A 1 SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH 4" MAX. PROJECTION FROM WALL. MATCH BUILDING STANDARD UNLESS NOTED OTHERWISE. MOUNT BOTTOM OF CABINET NOT LESS THAN 34" AFF. AND TOP OF CABINET SHALL NOT EXCEED 60" AFF. PROVIDE 5LB. ABC TYPE FIRE EXTINGUISHER. partition types refer to typical G0.0 sheets TYP. UNO EXISTING NON-RATED EXISTING RATED TYPE-B STUD WALL TO 10'-0" ABOVE CEILING, NON-RATED ACOUSTICAL architectural plan general notes CONSTRUCT NEW WALLS INTERSECTING EXISTING CONSTRUCTION TO ALIGN WITH FACE OF EXISTING WALL CONSTRUCTION. CONSTRUCT NEW WALLS INTERSECTING BUILDING COLUMN SURROUNDS TO ALIGN WITH THE FACE OF THE COLUMN OR CENTERED ON THE COLUMN AS INDICATED, UNLESS DIMENSIONED OTHERWISE. WALLS INTERSECTING WINDOW MULLIONS SHALL ALIGN WITH CENTER OF MULLION UNLESS NOTED OTHERWISE. REFER TO DETAIL 3/G0.0. CLOSE CONSTRUCTION TIGHT TO MULLION WITH BUILDING STANDARD DETAIL - BREAKMETAL TO MATCH WINDOW MULLION IN COLOR AND MATERIAL. CONTRACTOR SHALL MAINTAIN PARTITION RATING AND SOUND ATTENUATION. SUPPLY AND INSTALL WINDOW BLINDS AT ALL EXTERIOR WINDOWS TO MATCH EXISTING or REFER TO A4.1 FOR SELECTION. INFILL OF DOOR OPENINGS SHALL BE STANDARD METAL STUD CONSTRUCTION WITH GYPSUM WALLBOARD. MAINTAIN FIRE RATINGS OF EXISTING CONSTRUCTION. FINISHED SURFACE SHALL BE FLUSH WITH ADJACENT EXISTING PARTITION SURFACE architectural plan general notes CONTRACTOR SHALL PERFORM THE WORK INDICATED BY THESE NOTES IN AREAS DESIGNATED ON THE PLAN SPECIFIC KEYNOTE NUMBER. key notes architectural floor plan CONTRACTOR SHALL PERFORM THE WORK INDICATED BY THESE NOTES IN AREAS DESIGNATED ON THE PLAN SPECIFIC KEYNOTE NUMBER. key notes architectural floor plan door typical elevations door schedule hardware schedule 1 EA LEVER LOCKSET: 3553 WTN SFIC. FIN: US26D MFR: HGR 3 EACH HINGE: ECBB1 100 4.5X4.5 NRP 1 EA CYLINDER CORE: 3982-C FIN: US260 MFR: HGR 1 EA OVERHEAD HOLDER: 6015 SRF SZ1 FIN: US26D MFR: HGR 1 SET SEALS: PK33 BL 17' FIN : CLR MFR: PEM 1 EA LEVER LOCKSET: 3553 WTN SFIC. WITH 2 3/8" BACKSET FIN: US26D MFR: HGR 3 EACH HINGE: ECBB1 100 4.5X4.5 FIN: US26D MFR: HGR (HINGES PRE-HUNG BY DOOR MFR) 1 EA CYLINDER CORE: 3982-C FIN: US260 MFR: HGR 1 EA WALL STOP: 236W FIN: US32S MFR: HGR 1 SET SEALS: PK33 BL 17' FIN: CLR MFR: PEM UNLESS NOTED OTHERWISE ALL DOORS ARE 7'-0" A.F.F. UNLESS NOTED OTHERWISE LEVER HEIGHT IS 3'-4" A.F.F. ALL STAIN GRADE WOOD SHALL BE STAINED TO MATCH BUILDING STANDARD WOOD DOOR. SPECIES OF WOOD SHALL BE COMPATIBLE WITH STAIN MATCH. SUBMIT SAMPLES TO BUILDING REPRESENTATIVE AND ARCHITECT FOR APPROVAL. NOTE: MA MATCH EXISTING IN SPACE EX EXISTING TO REMAIN BB MATCH BASE BUILDING STANDARD A B D FLOOR PLAN PROVIDE APPROPRIATE HINGES ON EACH DOOR LEAF, AND SILENCERS ON ALL HOLLOW METAL FRAMES. PROVIDE FLOOR OR WALL STOPS AS APPROPRIATE FOR EACH LOCATION. HARDWARE FINISH TO MATCH BASE BUILDING STANDARD. ALL LOCKSET HARDWARE TO BE KEYED TO TENANT SPECIFICATION. NOTE: CONFIRM REMAINING EXISTING DOOR HARDWARE MEETS SCHEDULED FUNCTION AND IS ADA/ANSI COMPLIANT; REPLACE WHERE NECESSARY. 2'-8" x 7'-0" FLUSH SOLID CORE ELEVATION:FL FRAME: HOLLOW METAL FRAME FINISH: US260 MFR: HGR (HINGES PREHUNG BY DOOR MFR) 3'-0"X 7'-0" MELROSE MOLDED FULL PANELED DOOR, SOLID CORE MANUFACTURER: MASONITE ELEVATION: MP FRAME: HOLLOW METAL FRAME FINISH: BB 1 2 3 3'-0"X 7'-0" FULL GLASS PANEL AND WOOD ELEVATION: FG FRAME: HOLLOW METAL FRAME FINISH: BB GLASS: 1/4" CLEAR TEMPERED GLASS PAIR 3'-0" X 7'-0" FLUSH SOLID CORE WITH PAINTED LOUVERS ELEVATION: DFL FRAME: HOLLOW METAL FRAME FINISH: BB 4 NOTE: SUPPLY AND INSTALL WINDOW BLINDS AT ALL EXTERIOR WINDOWS MANUFACTURER: CUSTOM WINDOW COVERING 5871 CANE RIDGE ROAD, NASHVILLE, TN 37013 615.941.4106 MALIBU 6, 1" ALUMINUM HORIZONTAL BLIND 241,'%6 01 %*'%-'& &'5+)0'& 59&) 01 &#6' 4'8 design group llc. 100 taylor street|studio a10 nashville,tn 37208 (c)931.265.1602 www.sw-design-group.com CONTRACT DOCUMENTS .4% LRC SOLUTIONS,LLC SALONS BY JC SALONS BY JC 661 MT. JULIET ROAD, MT. JULIET, TN 661 S. MT. JULIET ROAD, MT. JULIET ,TN floor plan: 1/8" = 1'-0": 8' 4' 0 8' typical mounting heights & configurations DLV PAIR LOUVER DOORS DSF PAIR STORE FRONT ALUMINUM AND GLASS STOREFRONT T= TEMPERED GLASS 4'-0" ALIGN ALIGN 4" TYP 1 EA LEVER LATCHSET: 3553 WTN SFIC. WITH 2 3/8" BACKSET FIN: US26D MFR: HGR 3 EACH HINGE: ECBB1 100 4.5X4.5 FIN: US26D MFR: HGR (HINGES PREHUNG BY DOOR MFR) 1 EA SURFACE CLOSER: 4040 XP REG/PA FIN: AL MFR: LCN 2 EA KICKPLATE: 223S 10" X 34" FIN: US32D MFR: HGR 1 EA WALL STOP: 236W FIN: US32D MFR: HGR 1 SET SEALS: PK33 BL 17' FIN: CLR MFR: PEM 6 EA HINGE: ECBB1 100 4.5X4.5 FIN: US26D MFR: HGR (HINGES PRE-HUNG BY DOOR MFR) 1 EA LOCKSET: 3553 WTN SFIC FIN: US26D MFR: HGR 1 EA CYLINDER CORE: 3982-C FIN: US26D MFR: HGR 2 EA FLUSH BOLTS: (1 TOP, 1 BOT) 282D FIN: US26D MFR: HGR 2 EA WALL STOP: 236W FIN: US32D MFR: HGR 1 SET SEALS: PK33 BL 20' FIN: CLR MFR: PEM 1 THRESHOLD: PEMKO 151 ALUM. C WOOD ROLLING COUNTER SHUTTERS (WAYNE DALTON GARAGE DOORS 1.406.728.6243) COUNTERTOP OPENING TO BE 53"X 50", 36 AFF. CONTRACTOR TO SUBMIT WOOD FINISH FOR ARCHITECTURAL APPROVAL. CONSTRUCT PARTITION TO ALIGN WITH FACE OF COLUMN AS INDICATED. IF REQUIRED CLOSE CONSTRUCTION BETWEEN COLUMN AND WINDOW MULLION WITH SOUND ATTENUATION BATTING AND TRIM WITH BREAK METAL - SIMILAR TO DETAIL 3/G0.0 INTERIOR WINDOW GLAZING SHALL BE FIXED 3/8" TEMPERED GLASS, SEALED IN HOLLOW METAL FRAME 4'-0" X DOOR HEIGHT, NO. MULTIPLE GLASS PANELS SHALL BE SIZED EQUALLY AND BUTT GLAZED. WINDOW TO BE PLACED 12" MAX FROM DOOR. WITH 4" WOOD TRIM AROUND DOOR AND WINDOW. (PROVIDE LINE ITEM PRICING) MILLWORK IS TO COMPLY WITH THE ARCHITECTURAL WOODWORK INSTITUTE (AWI) STANDARDS, TO BE CUSTOM GRADE. CONSTRUCTION SHALL BE AS FOLLOWS: COUNTERTOPS : 1-1/2' PLASTIC LAMINATE COUNTER WITH SQUARE EDGE AND 4" BACK SPLASH. WATER RESISTANT SUBSTRATE AT WET LOCATIONS. BASE AND WALL CABINETS : FLUSH OVERLAY DESIGN WITH PLASTIC LAMINATE FINISH ON EXPOSED SURFACES, BLACK OR WHITE MELAMINE INTERIORS. DOOR HARDWARE : 4" WIRE PULLS AND CONCEALED HINGES. SEE ELEVATIONS A5.1 PROVIDE INTERIOR WINDOW GLAZING SHALL BE FIXED 3/8" TEMPERED ONE WAY GLASS IN METAL TRACK AT TOP AND BOTTOM, IN DRYWALL CASED OPENING 4'-0" X 4'-0", SEALED TO JAMBS WITH CLEAR SILICONE BUTT JOINT. REFER TO ELEVATION A5.1. (PROVIDE LINE ITEM PRICING) PROVIDE (2) SINGLE BOWL STAINLESS STEEL SINK, STANDARD KITCHEN TYPE FAUCET WITH PADDLE TYPE HOT/COLD CONTROLS. 15" FROM WALL ON BOTH SIDES. PROVIDE (2) DOUBLE STACKED WASHER AND DRYER HOOK-UP AT THIS LOCATION. CONTRACTOR TO INSTALL (2) MAYTAG STACK WASHER/DRYER MLE/MLG20PD. REFER TO PRICING PACKET. PROVIDE METAL TOILET PARTITIONS AND ACCESSORIES. PROVIDE REQUIRED ADA TOILETS AND LAVATORIES. URINALS ARE TO HAVE AUTOMATIC FLUSH VALVE. PROVIDE TOILET ACCESSORIES, INCLUDE ALL GRAB BARS, MIRROR ABOVE SINK, RECESSED PAPER TOWEL/ TRASH RECEPTACLE AND SOAP DISPENSER. INCLUDE BLOCKING AS REQUIRED FOR SUPPORT. INCLUDE SIGNAGE AS REQUIRED BY CODES. FIXTURE TYPES ARE TO MATCH BASE BUILDING STANDARD. PROVIDE SUBMITTALS FOR TENANT APPROVAL. REFER TO A5.1 FOR MOUNTING HEIGHTS. PROVIDE ADA HI/LO WATER FOUNTAIN, BUBBLER TYPE.. REFER TO A5.1 FOR MOUNTING HEIGHT. COORDINATE WITH ENGINEER FOR WATER BOTTLE FILLER SPECIFICATION. CONTRACTOR SHALL SUPPLY AND INSTALL SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH MAXIMUM PROJECTION FROM WALL OF 4". CABINET BOTTOM TO BE NOT LESS THAN 34"A.F.F. AND/ OR CABINET TOP NOT TO EXCEED 60" A.F.F. TYPE TO MATCH BASE BUILDING STANDARD. PROVIDE 5LB ABC TYPE EXTINGUISHER. PROVIDE AND INSTALL NEW EXTERIOR WINDOW IN PLACE OF DOOR AT THIS LOCATION. WINDOW TO MATCH APPROVED WINDOW SYSTEM PER LANDLORD COMENTS. CONTRACTOR TO PROVIDE AND INSTALL ADA LIFT AT THIS LOCATION. PROVIDE SUBMITTAL FOR TENANT APPROVAL. CONTRACTOR TO PROVIDE CONCRETE STAIRS AND COMPLIANT HAND RAILS AT THIS LOCATION. EXISTING DOOR AND HARDWARE TO REMAIN. PATCH AND REPAIR AS NEEDED. VERIFY EXISTING ADA COMPLIANT LEVER HARDWARE. REPLACE AS NEEDED. 4 5 6 7 8 CONTRACTOR TO PROVIDE AND INSTALL KAEMARK PLUMBING FIXTURE AND BASE; COLLINS. REFER TO ENGINEER DRAWINGS. PROVIDE BLOCKING AS REQUIRED FOR WORKSTATION AND MIRROR WITH SHELF. SUPPLY AND INSTALL STANDARD MALIBU 6, 1" ALUMINUM HORIZONTAL BLINDS AT ALL WORKSTATION WINDOW LOCATION. ALL SINK LOCATIONS TO BE 1'-6" CL FROM THE WALL WHEN THERE IS A CLEAR RIGHT APPROACH. SINKS TO BE INSTALLED 2'-4" CL FROM WALL IF THERE IS A CLEAR LEFT APPROACH. WHERE EXISTING OPENINGS ARE TO BE INFILLED - REMOVE EXISTING H.M. FRAME, DOOR AND HARDWARE AND PREPARE OPENING FOR INFILLING WITH MATERIALS TO MATCH EXISTING WALL CONSTRUCTION. PROVIDE AND INSTALL (2) WATER HEATER SIZED ACCORDINGLY AND JANITOR SINK AT THIS LOCATION. INCLUDE WATER SUPPLY AND DRAINAGE AS REQUIRED. CONTRACTOR TO EVALUATE EXISTING CONDITIONS AND INSTALL ACCORDINGLY. PROVIDE MOP SINK AT THIS LOCATION AS REQUIRE BY CODES. PROVIDE WATER LINE FOR OWNER FURNISHED COFFEE MAKER, LOCATION TO BE SPECIFIED IN FIELD; AND REFRIGERATOR w/ ICE MAKER. PROVIDE BLOCKING FOR TV BRACKETS @ TBD. COORDINATE EXACT HEIGHT IN CEILING CORNER OF EACH SUITE. APPROX 90" A.F.F. CONTRACTOR TO FURNISH AND INSTALL 2'-0" X 4'-0" EXTERIOR WINDOW AT THIS LOCATION. COORDINATE WITH LANDLORD FOR BASE BUILDING SPECIFICATIONS. SEE 12/A5.1 FOR INTERIOR HEIGHT. CONTRACTOR TO FURNISH AND INSTALL 4'-0" X 4'-0" EXTERIOR WINDOW AT THIS LOCATION. COORDINATE WITH LANDLORD FOR BASE BUILDING SPECIFICATIONS. SEE 11/A5.1 FOR INTERIOR HEIGHT. 9 10 11 12 13 14 15 16 17 18 NOTE: x FURR OUT ALL EXTERIOR WALLS TO A MINIMUM WITH DRYWALL AND INSULATION. ALL WALLS, INSULATION AND CEILINGS. x REFER TO G0.1 FOR TYPICAL ROOM LAYOUT. NOTE: x ALL FROSTING TO BE ON INTERIOR SIDE OF ROOM. x PREFFERRED DOOR SUPPLIER: BMC, CHUCK WENNING, [email protected], 972.462.5542 5 NOT USED PAIR 3'-0" X MA STORE FRONT DOOR ELEVATION: DSF FRAME: HOLLOW METAL FRAME FINISH: MATCH EXISTING STORE FRONT WINDOW SYSTEM GLASS: FULL GLASS 3'-0" X 7'-0" FLUSH SOLID CORE ELEVATION: FL FRAME: HOLLOW METAL FRAME FINISH: BB 6 EXISTING HARDWARE CAN REMAIN IF IN LIKE NEW CONDITION, OTHERWISE SPEC BELOW: 6 EA HINGE: EXBB1 100 4.5X4.5 FIN: US26D MFR: HGR 2 EA SURFACE CLOSER: 4040 XP REG/PA FIN: AL MFR: LCN 1 SET SEALS: PK33 BL 20' FIN: CLR MFR: PEM 1 THRESHOLD: PEMKO 151 ALUM 2 EA EXIT DEVICE/ PANIC HARDWARE: MSB550V FIN: 628 MFR: SEC BY OTHERS. DOOR KING *OWNER PROVIDED AND INSTALLED DOOR KING MAGNETIC LOCKING/ SECURITY SYSTEM TO BE ADDED. REFER TO PRICING PACKET. 3 EA HINGE: ECBB1 100 4.5X4.5 FIN: US26D MFR: HGR 1 EA SURFACE CLOSER: 4040 XP REG. PA FIN: AL MFR: LCN 1 SET SEALS: PK33 BL 20' FIN: CLR MFR: PEM 1 THRESHOLD: PEMKO 151 ALUM 1 DOOR VIEWER: HAGER 1765 1 EA EXIT DEVICE/ PANIC HARDWARE: MSB550V FIN: 628 MFR: SEC BY OTHERS. DOOR KING *OWNER PROVIDED AND INSTALLED DOOR KING MAGNETIC LOCKING/ SECURITY SYSTEM TO BE ADDED. REFER TO PRICING PACKET. E FL FLUSH PAINTED HOLLOW CORE WOOD MP MELROSE MOULDED PANEL DOOR CUSTOM 8' SIZE FULL PANELED DOOR SOLID CORE MP MELROSE MOULDED PANEL DOOR CUSTOM 8' SIZE FULL PANELED DOOR SOLID CORE PAINTED HOLLOW METAL DOOR AND FRAME 2" TYP. 2" TYP. TBD 11" TYP. TEMPERED GLASS A5.1 1 A5.1 5 A5.1 2 A5.1 7 A5.1 4 A5.1 3 A5.1 10 A5.1 9 A5.1 8 A5.1 6 NOTE: ALL INTERIOR AND EXTERIOR SINAGE TO BE SUPPLIED AND INSTALLED BY: CAM MULLINS SIGNS NOW/NASHVILLE SIGN CO. LLC 41 INDUSTRIAL PARK DRIVE HENDERSONVILLE, TN 37075 OFFICE: 615.824.1541/615.826.2002 SEE GO.1 FOR IMAGE 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 6 5 1 7 8 8 20 9 10 10 10 11 19 12 13 13 14 14 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 17 18 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 15 1'-3 1/2" 1'-1" 1'-1" 1'-1" 1'-1" 1'-1" 1'-3 1/2" 7'-0" F G 20 14 NOTE: ALL MILLWORK AND SALON EQUIPMENT TO BE PROVIDED BY COLLINS MANUFACTURING 2000 BOWSER ROAD COOKEVILLE, TN 38506 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 A 2 A 2 A 2 D 4 C 2 C 6 B 3 B 3 1'-0" A5.1 12 A5.1 11 RATED ONE HOUR TO UNDERSIDE OF DECK CONTRACTOR TO VERIFY ALL DEMISING WALLS ARE 1 HOUR RATED, MODIFY AS REQUIRED 1H 1H 1H 1H 1H 1H TYPE-B STUD WALL TO 11'-0" ABOVE CEILING, NON-RATED ACOUSTICAL NOTE: WALL HEIGHTS VARY: ALL INTERIOR WALLS THROUGHOUT HALLWAY SHOULD VARY BETWEEN 10'-0" AND 11'-0". REFER TO FLOOR PLANFOR FINAL LOCATIONS. DRYWALL TO BE FINISHED OUT AND TOPPED OFF WITH U CHANNEL OR PROVIDED EQUAL, AT TOP TO PROVIDE SMOOTH & STRAIGHT FINISH. NOTE: CONFIRM NO ADDITIONAL WINDOW TINTING IS BEING ADDED TO STOREFRONTS. NOTE: LANDLORD IS TO CONSTRUCT DEMISING WALL FOR ADJACENT TENANT. DRYWALL WILL NOT BE PROVIDED ON SALONS BY JC SIDE-TENANT RESPONSIBLE. COORDINATE TIMING OF INSTALL WITH LANDLORDS CONTRACTOR. EX EX EX EX NOTE: COORDINATE EXACT LOCATION OF CAMERA AND SECURITY SYSTEM WITH TENANT AND TENANTS LOW VOLTAGE SERVICE, CAMERA- MOUNTED FROM CEILING WITH APPROVED MANUFACTURER'S BRACKET. ROUGH-IN: COORDINATE WITH ELECTRICAL DRAWINGS AND SECURITY VENDOR. 21 21 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 11 11 5 22 23 22 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 24 25 25 25 25 25 25 25 25 25 25 25 24 24 24 24 24 24

Transcript of FLOOR PLAN - s3. · PDF filearchitectural floor plan 2 3 plan symbols floor plan 1 ALIGN ROOM...

Page 1: FLOOR PLAN - s3. · PDF filearchitectural floor plan 2 3 plan symbols floor plan 1 ALIGN ROOM NAME & NUMBER KEYNOTE ELEVATION TAG: ELEVATION REFERENCE SHEET REFERENCE ALIGN FINISHED

BREAK ROOM:140 SF W/S: 25

102 SF W/S: 24102 SF

W/S: 23102 SF

W/S: 22117 SF

W/S: 21106 SF

W/S: 20102 SF

W/S: 19105 SF W/S: 41

122 SF

W/S: 47117 SF

W/S: 49113 SF

W/S: 50102 SF

W/S: 18101 SF

W/S: 17104 SF

W/S: 16109 SF

W/S: 14116 SF

W/S: 13105 SF

W/S: 12153 SF

W/S: 11113 SF

W/S: 8113 SF

W/S: 7111 SF

W/S: 4110 SF

W/S: 3111 SF W/S: 1

106 SF

W/S: 10107 SF W/S: 9

102 SF W/S: 6100 SF

W/S: 5102 SF

W/S: 2112 SF

OFFICE:80 SF

W/S: 15129 SF

W/S: 51119 SF

W/S: 48115 SF W/S: 46

119 SF

W/S: 36112 SF

W/S: 45163 SF

W/S: 44143 SF

W/S: 43101 SF

W/S: 42100 SF

W/S: 40101 SF

W/S: 3896 SFW/S: 35

96 SF

W/S: 34104 SF

W/S: 33101 SF

W/S: 32104 SFW/S: 31

96 SF

W/S: 3096 SF

W/S: 29101 SF

W/S: 28101 SF

W/S: 2797 SF

W/S: 2697 SF

MEN:96 SF

WOMEN:

STG:35 SF

VEND

LIMIT OF CONSTRUCTION

LIFT

W/S: 37118 SF

W/S: 39124 SF

FEC

FEC

FEC

EXIT

4'-6

" AFF

4'-0

" AFF

6'-8

" MIN

. TO

UN

IT B

OTT

OM

FIN.FLOOR

3'-4

" AFF

1'-6

" AFF

LC

LC

LCLC

8"

LC

VARI

ES

NOTE:WHEN VARIOUS COMPONENTS OCCURON THE SAME WALL, ALIGN AS SHOWN.

CLG. HEIGHT

6"

LC LC

BASE CABINET

4" BACKSPLASH

TYP. OUTLET@COUNTER TOP

THERMOSTAT

PULL BOX

TYP. SWITCH

SCHEDULEDHARDWARE

TYP. ELEC., TELE.OR COMP. OUTLET

STROBE and/or HORN

REFER TO GENERAL NOTES SHEET G0.0 FOR GENERAL CONDITIONSAND REQUIREMENTS FOR ALL CONSTRUCTION.

CONTRACTOR TO PERFORM THE WORK OUTLINED IN THESE NOTES INALL AREAS OF CONSTRUCTION UNLESS NOTED OTHERWISE:

ALL DIMENSIONS ARE FROM FACE OF FINISH TO FACE OF FINISHUNLESS NOTED OTHERWISE.

CONTRACTOR SHALL COORDINATE STUD SIZE AND GAGENECESSARY FOR HEIGHT OF WALL, AS WELL AS FOR STRUCTURAL,MECHANICAL, PLUMBING, OR ELECTRICAL CLEARANCES PRIOR TOBEGINNING CONSTRUCTION. ANY DISCREPANCIES WITH LAYOUTAS DIMENSIONED SHALL BE COORDINATED IMMEDIATELY WITHARCHITECT.

IN FIRE RATED WALLS CONTRACTOR SHALL REINFORCE METAL STUDCONSTRUCTION WITH FIRE RESISTANT WOOD BLOCKING AT ALLLOCATIONS WHERE WALL CABINETS, SHELVING, GRAB BARS,ACCESSORIES, SIGNS, ETC., ARE TO BE INSTALLED. AT ALL OTHERWALL TYPES NON-FIRE RESISTANT WOOD BLOCKING IS ACCEPTABLEAT THESE INSTALLATIONS.

DOORS TO BE INSTALLED WITH JAMB SIDE 6" FROM INTERIOR FACEOF PERPENDICULAR WALL UNLESS NOTED OTHERWISE.

CONSTRUCT GYPSUM BOARD COLUMN WRAP WITH 7/8" HATCHANNELS OR 2-1/2" STUDS AND 5/8" GYPSUM WALLBOARD.MINIMIZE OUTSIDE DIMENSION OF COLUMN ENCLOSURE.INCORPORATE ANY ADJACENT PIPING OR ELECTRICAL DEVICES. IFCOLUMN WRAPS ARE LESS THAN 6" FROM ADJACENT WALLS,EXTEND GYPSUM ENCLOSURE TO INTERSECT WALL.

A1.1FLOOR PLAN

1

CONTRACTOR SHALL PERFORM THE WORK INDICATED BY THESE NOTES INAREAS DESIGNATED ON THE PLAN SPECIFIC KEYNOTE NUMBER.

key notes architectural floor plan

2

3

plan symbols floor plan

1

ALIGN

ROOM NAME & NUMBER

KEYNOTE

ELEVATION TAG:ELEVATION REFERENCE

SHEET REFERENCE

ALIGN FINISHED FACE OF PARTITIONWITH SURFACES INDICATED

PARTITION CONSTRUCTION TYPE, SEE"PARTITION TYPES" BELOW.

DOOR TYPE, RE: DOOR SCHEDULE &LEGEND.

HARDWARE TYPE, RE: HARDWARELEGEND.

CORE DRILL LOCATIONS (UPPERFLOORS) OR TRENCH STUB UP (FIRST

FLOOR) ARE SHOWN FOR DESIGNINTENT ONLY. DIMENSIONS ARE TO

CENTER LINE OF CORE DRILL/STUB UP.COORDINATE WITH ELECTRICAL

DRAWINGS FOR DEVICE SELECTION.

NAME#

plan symbols floor plan

A5.11

A1

SEMI-RECESSED FIRE EXTINGUISHER CABINETWITH 4" MAX. PROJECTION FROM WALL.

MATCH BUILDING STANDARD UNLESS NOTEDOTHERWISE. MOUNT BOTTOM OF CABINET

NOT LESS THAN 34" AFF. AND TOP OFCABINET SHALL NOT EXCEED 60" AFF.

PROVIDE 5LB. ABC TYPE FIRE EXTINGUISHER.

partition types refer to typical G0.0 sheets

TYP.UNO

EXISTING NON-RATED

EXISTING RATED

TYPE-B STUD WALL TO 10'-0"ABOVE CEILING, NON-RATEDACOUSTICAL

architectural plan general notes

CONSTRUCT NEW WALLS INTERSECTING EXISTING CONSTRUCTION TOALIGN WITH FACE OF EXISTING WALL CONSTRUCTION.

CONSTRUCT NEW WALLS INTERSECTING BUILDING COLUMNSURROUNDS TO ALIGN WITH THE FACE OF THE COLUMN ORCENTERED ON THE COLUMN AS INDICATED, UNLESS DIMENSIONEDOTHERWISE.

WALLS INTERSECTING WINDOW MULLIONS SHALL ALIGN WITH CENTEROF MULLION UNLESS NOTED OTHERWISE. REFER TO DETAIL 3/G0.0.CLOSE CONSTRUCTION TIGHT TO MULLION WITH BUILDING STANDARDDETAIL - BREAKMETAL TO MATCH WINDOW MULLION IN COLOR ANDMATERIAL. CONTRACTOR SHALL MAINTAIN PARTITION RATING ANDSOUND ATTENUATION.

SUPPLY AND INSTALL WINDOW BLINDS AT ALL EXTERIOR WINDOWS TOMATCH EXISTING or REFER TO A4.1 FOR SELECTION.

INFILL OF DOOR OPENINGS SHALL BE STANDARD METAL STUDCONSTRUCTION WITH GYPSUM WALLBOARD. MAINTAIN FIRE RATINGSOF EXISTING CONSTRUCTION. FINISHED SURFACE SHALL BE FLUSHWITH ADJACENT EXISTING PARTITION SURFACE

architectural plan general notesCONTRACTOR SHALL PERFORM THE WORK INDICATED BY THESE NOTES INAREAS DESIGNATED ON THE PLAN SPECIFIC KEYNOTE NUMBER.

key notes architectural floor plan

CONTRACTOR SHALL PERFORM THE WORK INDICATED BY THESE NOTES INAREAS DESIGNATED ON THE PLAN SPECIFIC KEYNOTE NUMBER.

key notes architectural floor plan

door typical elevations

door schedule

hardware schedule

1 EA LEVER LOCKSET: 3553 WTN SFIC. FIN: US26D MFR: HGR3 EACH HINGE: ECBB1 100 4.5X4.5 NRP1 EA CYLINDER CORE: 3982-C FIN: US260 MFR: HGR1 EA OVERHEAD HOLDER: 6015 SRF SZ1 FIN: US26D MFR: HGR1 SET SEALS: PK33 BL 17' FIN : CLR MFR: PEM

1 EA LEVER LOCKSET: 3553 WTN SFIC. WITH 2 3/8" BACKSETFIN: US26D MFR: HGR3 EACH HINGE: ECBB1 100 4.5X4.5 FIN: US26D MFR: HGR(HINGES PRE-HUNG BY DOOR MFR)1 EA CYLINDER CORE: 3982-C FIN: US260 MFR: HGR1 EA WALL STOP: 236W FIN: US32S MFR: HGR1 SET SEALS: PK33 BL 17' FIN: CLR MFR: PEM

UNLESS NOTED OTHERWISE ALL DOORS ARE 7'-0" A.F.F.UNLESS NOTED OTHERWISE LEVER HEIGHT IS 3'-4" A.F.F.ALL STAIN GRADE WOOD SHALL BE STAINED TO MATCH BUILDING STANDARD WOOD DOOR. SPECIES OF WOOD SHALL BE COMPATIBLE WITH STAIN MATCH. SUBMITSAMPLES TO BUILDING REPRESENTATIVE AND ARCHITECT FOR APPROVAL.

NOTE:MA MATCH EXISTING IN SPACEEX EXISTING TO REMAINBB MATCH BASE BUILDING STANDARD

A

B D

FLO

OR

PLA

N

PROVIDE APPROPRIATE HINGES ON EACH DOOR LEAF, AND SILENCERS ON ALL HOLLOW METAL FRAMES.

PROVIDE FLOOR OR WALL STOPS AS APPROPRIATE FOR EACH LOCATION.

HARDWARE FINISH TO MATCH BASE BUILDING STANDARD.

ALL LOCKSET HARDWARE TO BE KEYED TO TENANT SPECIFICATION.

NOTE: CONFIRM REMAINING EXISTING DOOR HARDWARE MEETS SCHEDULED FUNCTION AND IS ADA/ANSI COMPLIANT; REPLACE WHERE NECESSARY.

2'-8" x 7'-0" FLUSH SOLID COREELEVATION:FLFRAME: HOLLOW METAL FRAMEFINISH: US260 MFR: HGR (HINGES PREHUNG BYDOOR MFR)

3'-0"X 7'-0" MELROSE MOLDED FULL PANELEDDOOR, SOLID COREMANUFACTURER: MASONITEELEVATION: MPFRAME: HOLLOW METAL FRAMEFINISH: BB

1

2

3

3'-0"X 7'-0" FULL GLASS PANEL AND WOODELEVATION: FGFRAME: HOLLOW METAL FRAMEFINISH: BBGLASS: 1/4" CLEAR TEMPERED GLASS

PAIR 3'-0" X 7'-0" FLUSH SOLID CORE WITHPAINTED LOUVERSELEVATION: DFLFRAME: HOLLOW METAL FRAMEFINISH: BB

4

NOTE:SUPPLY AND INSTALL WINDOW BLINDS AT ALL EXTERIORWINDOWSMANUFACTURER: CUSTOM WINDOW COVERING5871 CANE RIDGE ROAD, NASHVILLE, TN 37013615.941.4106MALIBU 6, 1" ALUMINUM HORIZONTAL BLIND

design group llc.100 taylor street|studio a10

nashville,tn 37208(c)931.265.1602

www.sw-design-group.com

CO

NTR

AC

T DO

CUM

ENTS

LRC

SO

LUTIO

NS,

LLC

SALONS BY JC

SALO

NS

BY J

C 6

61 M

T. J

ULIE

T RO

AD

, M

T. J

ULIE

T, T

N

661 S. MT. JULIET ROAD, MT. JULIET ,TN

floor plan:1/8" = 1'-0":

8' 4' 0 8'

typical mounting heights &configurations

DLVPAIR LOUVERDOORS

DSFPAIR STORE FRONTALUMINUM AND GLASSSTOREFRONTT= TEMPERED GLASS

4'-0"

ALIGN

ALIGN

4" TYP

1 EA LEVER LATCHSET: 3553 WTN SFIC. WITH 2 3/8" BACKSETFIN: US26D MFR: HGR3 EACH HINGE: ECBB1 100 4.5X4.5 FIN: US26D MFR: HGR(HINGES PREHUNG BY DOOR MFR)1 EA SURFACE CLOSER: 4040 XP REG/PA FIN: AL MFR: LCN2 EA KICKPLATE: 223S 10" X 34" FIN: US32D MFR: HGR1 EA WALL STOP: 236W FIN: US32D MFR: HGR1 SET SEALS: PK33 BL 17' FIN: CLR MFR: PEM

6 EA HINGE: ECBB1 100 4.5X4.5 FIN: US26D MFR: HGR(HINGES PRE-HUNG BY DOOR MFR)1 EA LOCKSET: 3553 WTN SFIC FIN: US26D MFR: HGR1 EA CYLINDER CORE: 3982-C FIN: US26D MFR: HGR2 EA FLUSH BOLTS: (1 TOP, 1 BOT) 282D FIN: US26D MFR: HGR2 EA WALL STOP: 236W FIN: US32D MFR: HGR1 SET SEALS: PK33 BL 20' FIN: CLR MFR: PEM1 THRESHOLD: PEMKO 151 ALUM.

C

WOOD ROLLING COUNTER SHUTTERS (WAYNE DALTON GARAGE DOORS1.406.728.6243) COUNTERTOP OPENING TO BE 53"X 50", 36 AFF.CONTRACTOR TO SUBMIT WOOD FINISH FOR ARCHITECTURAL APPROVAL.

CONSTRUCT PARTITION TO ALIGN WITH FACE OF COLUMN AS INDICATED.IF REQUIRED CLOSE CONSTRUCTION BETWEEN COLUMN AND WINDOWMULLION WITH SOUND ATTENUATION BATTING AND TRIM WITH BREAKMETAL - SIMILAR TO DETAIL 3/G0.0

INTERIOR WINDOW GLAZING SHALL BE FIXED 3/8" TEMPERED GLASS,SEALED IN HOLLOW METAL FRAME 4'-0" X DOOR HEIGHT, NO. MULTIPLEGLASS PANELS SHALL BE SIZED EQUALLY AND BUTT GLAZED. WINDOW TOBE PLACED 12" MAX FROM DOOR. WITH 4" WOOD TRIM AROUND DOORAND WINDOW. (PROVIDE LINE ITEM PRICING)

MILLWORK IS TO COMPLY WITH THE ARCHITECTURAL WOODWORKINSTITUTE (AWI) STANDARDS, TO BE CUSTOM GRADE. CONSTRUCTIONSHALL BE AS FOLLOWS:COUNTERTOPS: 1-1/2' PLASTIC LAMINATE COUNTER WITH SQUARE EDGE AND 4" BACKSPLASH. WATER RESISTANT SUBSTRATE AT WET LOCATIONS.BASE AND WALL CABINETS:FLUSH OVERLAY DESIGN WITH PLASTIC LAMINATE FINISH ON EXPOSEDSURFACES, BLACK OR WHITE MELAMINE INTERIORS.DOOR HARDWARE:4" WIRE PULLS AND CONCEALED HINGES. SEE ELEVATIONS A5.1

PROVIDE INTERIOR WINDOW GLAZING SHALL BE FIXED 3/8" TEMPERED ONEWAY GLASS IN METAL TRACK AT TOP AND BOTTOM, IN DRYWALL CASEDOPENING 4'-0" X 4'-0", SEALED TO JAMBS WITH CLEAR SILICONE BUTT JOINT.REFER TO ELEVATION A5.1. (PROVIDE LINE ITEM PRICING)

PROVIDE (2) SINGLE BOWL STAINLESS STEEL SINK, STANDARD KITCHEN TYPEFAUCET WITH PADDLE TYPE HOT/COLD CONTROLS. 15" FROM WALL ONBOTH SIDES.

PROVIDE (2) DOUBLE STACKED WASHER AND DRYER HOOK-UP AT THISLOCATION. CONTRACTOR TO INSTALL (2) MAYTAG STACKWASHER/DRYER MLE/MLG20PD. REFER TO PRICING PACKET.

PROVIDE METAL TOILET PARTITIONS AND ACCESSORIES. PROVIDEREQUIRED ADA TOILETS AND LAVATORIES. URINALS ARE TO HAVEAUTOMATIC FLUSH VALVE. PROVIDE TOILET ACCESSORIES, INCLUDE ALLGRAB BARS, MIRROR ABOVE SINK, RECESSED PAPER TOWEL/ TRASHRECEPTACLE AND SOAP DISPENSER. INCLUDE BLOCKING AS REQUIREDFOR SUPPORT. INCLUDE SIGNAGE AS REQUIRED BY CODES. FIXTURE TYPESARE TO MATCH BASE BUILDING STANDARD. PROVIDE SUBMITTALS FORTENANT APPROVAL. REFER TO A5.1 FOR MOUNTING HEIGHTS.

PROVIDE ADA HI/LO WATER FOUNTAIN, BUBBLER TYPE.. REFER TO A5.1FOR MOUNTING HEIGHT. COORDINATE WITH ENGINEER FOR WATERBOTTLE FILLER SPECIFICATION.

CONTRACTOR SHALL SUPPLY AND INSTALL SEMI-RECESSED FIREEXTINGUISHER CABINET WITH MAXIMUM PROJECTION FROM WALL OF 4".CABINET BOTTOM TO BE NOT LESS THAN 34"A.F.F. AND/ OR CABINET TOPNOT TO EXCEED 60" A.F.F. TYPE TO MATCH BASE BUILDING STANDARD.PROVIDE 5LB ABC TYPE EXTINGUISHER.

PROVIDE AND INSTALL NEW EXTERIOR WINDOW IN PLACE OF DOOR ATTHIS LOCATION. WINDOW TO MATCH APPROVED WINDOW SYSTEM PERLANDLORD COMENTS.

CONTRACTOR TO PROVIDE AND INSTALL ADA LIFT AT THIS LOCATION.PROVIDE SUBMITTAL FOR TENANT APPROVAL.

CONTRACTOR TO PROVIDE CONCRETE STAIRS AND COMPLIANT HANDRAILS AT THIS LOCATION.

EXISTING DOOR AND HARDWARE TO REMAIN. PATCH AND REPAIR ASNEEDED. VERIFY EXISTING ADA COMPLIANT LEVER HARDWARE. REPLACEAS NEEDED.

4

5

6

7

8

CONTRACTOR TO PROVIDE AND INSTALL KAEMARK PLUMBING FIXTUREAND BASE; COLLINS. REFER TO ENGINEER DRAWINGS.

PROVIDE BLOCKING AS REQUIRED FOR WORKSTATION AND MIRROR WITHSHELF.

SUPPLY AND INSTALL STANDARD MALIBU 6, 1" ALUMINUM HORIZONTALBLINDS AT ALL WORKSTATION WINDOW LOCATION.

ALL SINK LOCATIONS TO BE 1'-6" CL FROM THE WALL WHEN THERE IS ACLEAR RIGHT APPROACH. SINKS TO BE INSTALLED 2'-4" CL FROM WALL IFTHERE IS A CLEAR LEFT APPROACH.

WHERE EXISTING OPENINGS ARE TO BE INFILLED - REMOVE EXISTING H.M.FRAME, DOOR AND HARDWARE AND PREPARE OPENING FOR INFILLINGWITH MATERIALS TO MATCH EXISTING WALL CONSTRUCTION.

PROVIDE AND INSTALL (2) WATER HEATER SIZED ACCORDINGLY ANDJANITOR SINK AT THIS LOCATION. INCLUDE WATER SUPPLY ANDDRAINAGE AS REQUIRED. CONTRACTOR TO EVALUATE EXISTINGCONDITIONS AND INSTALL ACCORDINGLY.

PROVIDE MOP SINK AT THIS LOCATION AS REQUIRE BY CODES.

PROVIDE WATER LINE FOR OWNER FURNISHED COFFEE MAKER,LOCATION TO BE SPECIFIED IN FIELD; AND REFRIGERATOR w/ ICE MAKER.

PROVIDE BLOCKING FOR TV BRACKETS @ TBD. COORDINATE EXACTHEIGHT IN CEILING CORNER OF EACH SUITE. APPROX 90" A.F.F.

CONTRACTOR TO FURNISH AND INSTALL 2'-0" X 4'-0" EXTERIOR WINDOWAT THIS LOCATION. COORDINATE WITH LANDLORD FOR BASE BUILDINGSPECIFICATIONS. SEE 12/A5.1 FOR INTERIOR HEIGHT.

CONTRACTOR TO FURNISH AND INSTALL 4'-0" X 4'-0" EXTERIOR WINDOWAT THIS LOCATION. COORDINATE WITH LANDLORD FOR BASE BUILDINGSPECIFICATIONS. SEE 11/A5.1 FOR INTERIOR HEIGHT.

9

10

11

12

13

14

15

16

17

18NOTE: FURR OUT ALL EXTERIOR WALLS TO A MINIMUM WITH DRYWALL

AND INSULATION. ALL WALLS, INSULATION AND CEILINGS.

REFER TO G0.1 FOR TYPICAL ROOM LAYOUT.

NOTE: ALL FROSTING TO BE ON INTERIOR SIDE OF ROOM. PREFFERRED DOOR SUPPLIER: BMC, CHUCK WENNING,

[email protected], 972.462.5542

5

NOT USED

PAIR 3'-0" X MA STORE FRONT DOORELEVATION: DSFFRAME: HOLLOW METAL FRAMEFINISH: MATCH EXISTING STORE FRONTWINDOW SYSTEMGLASS: FULL GLASS

3'-0" X 7'-0" FLUSH SOLID COREELEVATION: FLFRAME: HOLLOW METAL FRAMEFINISH: BB

6

EXISTING HARDWARE CAN REMAIN IF IN LIKE NEW CONDITION,OTHERWISE SPEC BELOW:6 EA HINGE: EXBB1 100 4.5X4.5 FIN: US26D MFR: HGR2 EA SURFACE CLOSER: 4040 XP REG/PA FIN: AL MFR: LCN1 SET SEALS: PK33 BL 20' FIN: CLR MFR: PEM1 THRESHOLD: PEMKO 151 ALUM2 EA EXIT DEVICE/ PANIC HARDWARE: MSB550V FIN: 628MFR: SEC BY OTHERS. DOOR KING*OWNER PROVIDED AND INSTALLED DOOR KING MAGNETICLOCKING/ SECURITY SYSTEM TO BE ADDED. REFER TO PRICINGPACKET.

3 EA HINGE: ECBB1 100 4.5X4.5 FIN: US26D MFR: HGR1 EA SURFACE CLOSER: 4040 XP REG. PA FIN: AL MFR: LCN1 SET SEALS: PK33 BL 20' FIN: CLR MFR: PEM1 THRESHOLD: PEMKO 151 ALUM1 DOOR VIEWER: HAGER 17651 EA EXIT DEVICE/ PANIC HARDWARE: MSB550V FIN: 628MFR: SEC BY OTHERS. DOOR KING*OWNER PROVIDED AND INSTALLED DOOR KING MAGNETICLOCKING/ SECURITY SYSTEM TO BE ADDED. REFER TO PRICINGPACKET.

E

FLFLUSHPAINTED HOLLOWCORE WOOD

MPMELROSE MOULDED PANELDOORCUSTOM 8' SIZEFULL PANELED DOORSOLID CORE

MPMELROSE MOULDED PANELDOORCUSTOM 8' SIZEFULL PANELED DOORSOLID CORE

PAINTED HOLLOW METALDOOR AND FRAME

2" TYP.

2" T

YP.

TBD

11" T

YP.

TEMPEREDGLASS

A5.11

A5.15

A5.12

A5.17

A5.14

A5.13

A5.110

A5.19

A5.18

A5.16

NOTE:ALL INTERIOR AND EXTERIOR SINAGE TO BE SUPPLIED AND INSTALLEDBY:CAM MULLINSSIGNS NOW/NASHVILLE SIGN CO. LLC41 INDUSTRIAL PARK DRIVEHENDERSONVILLE, TN 37075OFFICE: 615.824.1541/615.826.2002

SEE GO.1 FOR IMAGE

2

2

3 3 3 33

3

3

3

3

3

3 3 3 3 3 3 3 3 3 3 3

333333333

33333

3

3

3

3

3

3

3

3

3 3 3 3 3

4

4

6

5

1

7

8

8

20

9

10

10

10

11

19

12

13

13

14

14

1515

1515

1515

15

151515

15

15

15

15

15

15

15

15

15

15151515

15

15

15

15

15

15

15

1515

15

15

15

1515 15

15

15

15

1515

15

15

15

15

15

15 15

16

16

16

16

16

16

16

16

16

16

16

16

16

16

16

16161616

16

16

16

16

16

16

16 16

16

16

16

16

16

16

16

16

16

1616

16

16

16

16

16

16

16

16

16

16

16

16

1616

1616

17

18

17

17 1717

17

17

17

17

17

17

17

17

17

17

17

17

17

17

17

17

17

17

1717

17

17

17

17

17

17

17

1717

17

17

17

17

17

17

17

1717

17

17

1717

17

18 18 18 18 18 18

1818

18

18

18

1818

18 18

18

1818

18

1818

18

18

18

18

18

18

1818

18

18

18

18

18

18

18

18

1818

18 18 18 1818

1818

18

18

18

18

15

1'-3

1/2

" 1'-1

"1'

-1"

1'-1

"1'

-1"

1'-1

"1'-3

1/2

"

7'-0

"

F

G

20

14

NOTE:ALL MILLWORK AND SALON EQUIPMENT TO BE PROVIDED BYCOLLINS MANUFACTURING 2000 BOWSER ROAD COOKEVILLE, TN38506

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2 B

2B2

B2

B2

B2 B

2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2 B

2B2

B2

B2 B

2

B2

B2

B2

B2B

2

B2

B2

B2

B2

B2

B2

B2

A2

A2

A2

D4

C2

C6

B3

B3

1'-0"

A5.112

A5.111

RATED ONE HOURTO UNDERSIDE OF DECKCONTRACTOR TO VERIFY ALLDEMISING WALLS ARE 1 HOURRATED, MODIFY AS REQUIRED

1H

1H 1H 1H1H1H

TYPE-B STUD WALL TO 11'-0"ABOVE CEILING, NON-RATEDACOUSTICAL

NOTE:WALL HEIGHTS VARY:ALL INTERIOR WALLS THROUGHOUT HALLWAY SHOULD VARYBETWEEN 10'-0" AND 11'-0". REFER TO FLOOR PLANFOR FINALLOCATIONS. DRYWALL TO BE FINISHED OUT AND TOPPED OFF WITHU CHANNEL OR PROVIDED EQUAL, AT TOP TO PROVIDE SMOOTH& STRAIGHT FINISH.

NOTE:CONFIRM NO ADDITIONAL WINDOW TINTING IS BEING ADDED TOSTOREFRONTS.

NOTE:LANDLORD IS TO CONSTRUCT DEMISING WALL FOR ADJACENTTENANT. DRYWALL WILL NOT BE PROVIDED ON SALONS BY JCSIDE-TENANT RESPONSIBLE. COORDINATE TIMING OF INSTALL WITHLANDLORDS CONTRACTOR.

EXEX

EXEX

NOTE:COORDINATE EXACT LOCATION OF CAMERA AND SECURITYSYSTEM WITH TENANT AND TENANTS LOW VOLTAGE SERVICE,CAMERA- MOUNTED FROM CEILING WITH APPROVEDMANUFACTURER'S BRACKET. ROUGH-IN: COORDINATE WITHELECTRICAL DRAWINGS AND SECURITY VENDOR.

21

21

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5 5

5

5

5

5

55

5

5

5

5

5

55

5

5

5

5

5

5

5

55

5

5

55

5 5

11

11

5

22

23

22

23

23

23 2323 23 23

232323

23

23

23

23

23

23

2323

23

23

232323

23 2323

23

23

23

23 2323

2323

23

2323

23

232323

2323

2323

23 23

2323

2323

24

25

25 25 25 25 25 25

25

25

25

25

242424242424