Floataround Spec & Cut Sheet - USA · 2019. 2. 6. · Floataround Spec & Cut Sheet - USA...

3
Floataround Spec & Cut Sheet - USA Dimensions: External diameter : 8'0.5" External height :7'8" Internal diameter : 7’7” Internal height : 6’8” Technical pack: (can be specified at back, left or right of the door or in an adjacent room) curved to match product : 45.5” wide x 17” high x 20” deep Volume of solution: at 11” depth : 317 US gal, requiring 1,320 lbs salt Weight when full: 3,869lbs (including salt) Floor loading: 0.45psi Remote control unit: we advise locating the unit (one per product) in the reception area where the LAN cables terminate. Dimensions : 8” x 4 ¾” x 1.5”. A wall-mounting bracket is supplied. A power outlet is required near the remote unit for the music source (not provided). A 3.5mm jack lead (39”long) is provided to connect the music source to the remote unit. A shelf next to the remote unit is useful to hold the music source. Services: Electrical supply: USA and Canada: 2*, single phase, 208-240V three wire (“two hots, neutral and ground”) 60Hz AC, 20A via a 20A breaker and two gang back wired sockets. The mating plug and cable to our equipment must be supplied by your electrician. (*We recommend installing the second supply cable as above for upgrade options such as silent air heating, which we also recommend.) Any other supply, including 120 volt, requires consultation and will involve extra cost. Floataway needs to know the supply voltage in every case. Data cable: 3 runs of Cat6 LAN cable terminated in female RJ45 sockets from the float room to your reception area. Water supply: This is a stand alone product, not connected to the water supply, but we recommend installing a water faucet in the float room for cleaning and maintenance. Shower: A shower must be installed in every float room. We recommend an open shower (see additional technical information for preparing the float room). Drain: No drain required for the cabin (unless required by local regulation), but a floor drain is strongly advised. HVAC: in Floataround : the product is not connected to the room ventilation system in float room : minimum one air exchange per hour required. The air temperature should be approximately 80°F, thermostatically controlled in the room. Relative humidity (RH) target: 60% in the room. Ventilation to be as silent as possible with a low speed fan and manual switching in the room. Flooring: Must be strong enough, waterproof, non-slip, bunded to 4”, level under the product and have a floor drain.

Transcript of Floataround Spec & Cut Sheet - USA · 2019. 2. 6. · Floataround Spec & Cut Sheet - USA...

Page 1: Floataround Spec & Cut Sheet - USA · 2019. 2. 6. · Floataround Spec & Cut Sheet - USA Dimensions: External diameter : 8'0.5" External height :7'8" Internal diameter : 7’7”

Floataround Spec & Cut Sheet - USADimensions: External diameter : 8'0.5" External height :7'8"

Internal diameter : 7’7” Internal height : 6’8” Technical pack: (can be specified at back, left or right of the door or in anadjacent room) curved to match product : 45.5” wide x 17” high x 20” deep Volume of solution: at 11” depth : 317 US gal, requiring 1,320 lbs salt Weight when full: 3,869lbs (including salt) Floor loading: 0.45psi Remote control unit: we advise locating the unit (one per product)in the reception area where the LAN cables terminate.Dimensions : 8” x 4 ¾” x 1.5”. A wall-mounting bracket is supplied. A power outlet is required near the remote unit for the music source (not provided).A 3.5mm jack lead (39”long) is provided to connect the music source to the remoteunit. A shelf next to the remote unit is useful to hold the music source.

Services:

Electrical supply:USA and Canada: 2*, single phase, 208-240V three wire (“two hots, neutral and ground”) 60Hz AC, 20A via a20A breaker and two gang back wired sockets. The mating plug and cable to our equipment must be suppliedby your electrician. (*We recommend installing the second supply cable as above for upgrade options such assilent air heating, which we also recommend.) Any other supply, including 120 volt, requires consultation and will involve extra cost. Floataway needs toknow the supply voltage in every case. Data cable: 3 runs of Cat6 LAN cable terminated in female RJ45 sockets from the float room to yourreception area. Water supply: This is a stand alone product, not connected to the water supply, but we recommend installinga water faucet in the float room for cleaning and maintenance. Shower: A shower must be installed in every float room. We recommend an open shower (see additionaltechnical information for preparing the float room). Drain: No drain required for the cabin (unless required by local regulation), but a floor drain is stronglyadvised. HVAC: in Floataround : the product is not connected to the room ventilation system

in float room : minimum one air exchange per hour required. The air temperature should beapproximately 80°F, thermostatically controlled in the room. Relative humidity (RH) target: 60% inthe room. Ventilation to be as silent as possiblewith a low speed fan and manual switching in the room.

Flooring: Must be strong enough, waterproof, non-slip, bunded to 4”, level under the productand have a floor drain.

Page 2: Floataround Spec & Cut Sheet - USA · 2019. 2. 6. · Floataround Spec & Cut Sheet - USA Dimensions: External diameter : 8'0.5" External height :7'8" Internal diameter : 7’7”

the room. Ventilation to be as silent as possiblewith a low speed fan and manual switching in the room.

Flooring: Must be strong enough, waterproof, non-slip, bunded to 4”, level under the productand have a floor drain. Room Lighting: The room requires an independent bright light for cleaning and maintenance. The product has dim room lighting when in use (which switches with pool light). Room surfaces: Wet room code, windows should be made dark.

Construction:• Top quality Glass Reinforced Plastic (GRP) gel on vinyl ester, round pool in 4 bolted

sections, sealed on site, usually white• GRP domed ceiling in 4 bolted sections

• 4 continuous ceiling heaters, 80W each, thermostatically controlled (eliminates all condensation and heats air)

• 4 continuous 350W heaters under pool, 1.5” rigid fire resistant insulation to floor• Curved acrylic walls, choice of colors (translucent or opaque)• Twin frosted glass doors with edge seals and stainless hinges• Temperature control by programmable digital thermostat in unique control system

• Underwater full spectrum colored light with user control• Integrated room light in ceiling which switches with pool light• End of session chimes sounder• Over-temperature and low water alarms• Unique top entry cartridge filter, surface skimming

system, cyclic pump timing.

• 1 to 75 micron filtration system with unique top entryfilter

housing for standard 9 7/8” cartridges • Powerful magnetic drive pump (all plastic

construction), capable of 5 minute turnover

• Full airflow design ventilation, draught free• Emergency battery keep product operating for at least 90

minutes in case of a power cut.• 4 sound transducers (loudspeakers), full frequency drivers bonded to pool sides suitable for

any sound source (player not supplied)• Call attendant and light switch buttons via air coupled switches for total electrical

isolation• Pre-assembled technical pack housed on a GRP base and covered with a GRP lid which

can serve as a bench in float room• Hand rails at pool entrance• Elegant remote session control which can be located up to 330’ away with many functions

(See remote specification for details.)• Designed and constructed in accordance with UL requirements (NFPA 70, UL 1795, UL

1563, UL 508A) and EN 60335-2-60:2003+A12:2010 and EN 60335-1:2012+A11:201

Optional Extras:

• Disinfection by automatic timed doser for chlorine or peroxide• Ground noise isolation system• UV filter (recommended with peroxide)• Music mute button• Star effect ceiling using fiber optics• Two way intercom system• Redox disinfection system for chlorine• Reverse osmosis (RO) water filtering

Page 3: Floataround Spec & Cut Sheet - USA · 2019. 2. 6. · Floataround Spec & Cut Sheet - USA Dimensions: External diameter : 8'0.5" External height :7'8" Internal diameter : 7’7”

• Star effect ceiling using fiber optics• Two way intercom system• Redox disinfection system for chlorine• Reverse osmosis (RO) water filtering• Automatic water adding system (requires RO)• Hibernation system for intermittent use

Please ask about any other special requirements. This document must be given to the building contractor. Any questions should be sent in writing [email protected]. It is important to note that for the Floataround we need access all round and therefore thestrict minimum room is 11’ by 13’, but 13’ by 15’ would be better. Please ask for adviceabout curved walls or special rooms. The modular construction means the parts can even becarried through corridors with narrow corners or stairs. Please submit your floor plans to us so that we can verify whether the float cabin will fit intothe space you have allocated. We will indicate on your floor plans where you should put yoursockets/outlets. The Floataround is designed for couple floating to increase revenue and encourage newcustomers, however, it can also be used by one person alone. Self-installation is possible for practically minded people. Electrical installation should always be done by aqualified electrician. Floataway will install for an additional fee.

Technical drawings available upon request. SketchUp versions are available on the Floataway library within theSketchUp application. Thanks to our policy of continuous improvement, these details may change without notice. This is one of the models chosen by Dr. Justin Feinstein of the Laureate Institute for Brain Research (LIBR) inTulsa, Oklahoma.

+++