Flexipacket commissioning steps:
PC Requirement
Microsoft xp,windows 7 /windowos 8
NSN flexi packet commissioning tool(CT)-1.3.37
Java Runtime Environment (JRE) Version-6.26
Ethernet straight cable.
Setting IP address:
Default IP of Flexipacket Hub 800 is 192.168.255.100.
Put the below IP in your laptop and connect to DCN port of Flexipacket Hub 800.
-
7/22/2019 Flexipacket Commissioning Steps
2/17
Run NSN Flexi Packet Commissioning Tool on your PC.
Select FPH800 from Equipment drop-down list and leave the Operation Mode drop-down list unmodified as Assisted. Click Next
Select start from scratch and click next
-
7/22/2019 Flexipacket Commissioning Steps
3/17
The following commissioning wizard will appear .then click next.
Then following screen will appear click next.
-
7/22/2019 Flexipacket Commissioning Steps
4/17
Continue clicking next to configure IDU.
Set the Management VLAN Setting according to the IP Plan. Otherwise leave it unmodified as
127.
Check the Synchronize time from PC to IDU checkbox.
Set (GMT +03:00) for Time zone drop-down list.Set Daylight saving enable to Disable.
Set IDU IP Setting according to the IP Plan. If there is no IP Plan. So please set the network
elements IP address as belowLeave Card Setting unmodified. Click Next >.
IDU IP address: 10.122.12.40
Default gateway: 10.122.12.1
Note: for far end IDU put 10.122.12.39
-
7/22/2019 Flexipacket Commissioning Steps
5/17
Select IDU-A GE 0/3 (PWR)(1103) then IDU-A GE 0/4 (PWR)(1104), the port youconnected to the ODU, from IDU port drop-down list.
Set ODU IP Setting according to the IP Plan. If, there is no IP Plan. So please set thenetwork elements IP addres as below .
-1 IP address: 10.122.12.42
-2 IP address: 10.122.12.44
t gateway: 10.122.12.1
Note: For far end Put ODU put 10.122.12.41 & 10.122.12.43 respectively
Set the PWR source to PWR on integrated device.Select NO from Ring topology drop-down list.Specify the ODU type as FPMR(P).Leave the Mode unmodified as NNI.Set the Power supply to Enable.Click Add button. Then the configuration of the port to ODUwill be added to the listbox as below.
-
7/22/2019 Flexipacket Commissioning Steps
6/17
-
7/22/2019 Flexipacket Commissioning Steps
7/17
Click next then following screen will appear. Then click next
-
7/22/2019 Flexipacket Commissioning Steps
8/17
At first, select FPMR (P) based on your equipment, from ODU type drop-down list.
Set ODU system type to 2+0 XPIC.
Set the ip of Vertical /master ODU and the Horizontal/slave ODU from their drop-downlists.
Select revertive from Switch mode drop-down list.
Click Add. Then the configuration of ODU System Type will be added to the list box
-
7/22/2019 Flexipacket Commissioning Steps
9/17
Following screen will appear .then click next.
Click Next.
-
7/22/2019 Flexipacket Commissioning Steps
10/17
Set TX profile as 256QAM and ACM TX Enable as disable then click modify
and click next
Set TX Power as Per TD and click Modify click next
-
7/22/2019 Flexipacket Commissioning Steps
11/17
Following screen will appear click Next..
Click Next.
-
7/22/2019 Flexipacket Commissioning Steps
12/17
Set Tx Frequency as per TD and channel bandwidth as 28MHZ and put Radio Port up
Click Modify and click Next.
Set Time GMT +3:00 and daylight disable.
Click Next..
-
7/22/2019 Flexipacket Commissioning Steps
13/17
Save setting and click Next..
Put the current IDU IP and select Local area connection. Click Next
-
7/22/2019 Flexipacket Commissioning Steps
14/17
Click Validate.
If there is no setting error among your configuration, the progress bar will fulfill 100% and No setting
error found. message will be shown. Otherwise the incorrect or improper sub-step will turn redto
indicate where the error occurred. So you can go back to that sub-step, find and rectify the issue and run
validation again
-
7/22/2019 Flexipacket Commissioning Steps
15/17
Click Run
After clicking Run, the Commissioning Tool will present the commissioning processesstep-
by-step using the following progress bars and their titles.
-
7/22/2019 Flexipacket Commissioning Steps
16/17
Click Next
Click Exit. And commissioning is finished..
-
7/22/2019 Flexipacket Commissioning Steps
17/17
Then change your laptop IP to: 10.122.12.50 to access IDU or
change IP as per you have configured the IDU.
TO ACCESS CONFIGURED IDU:
Click on runct.
Select FPH800 and select mode as advance.
Type the IDU IP .click next.
Type the gateway and click Connect
TO ACCESS IDU THROUGH OBB PORT.
OBB PORT IP: 192.168.254.100
Laptop: 192.168.254.130
USER: admin
Password: sysmanager