flexi_lite_quick_guide-0900d80580a0ba9f.pdf

13
 Flexi BTS Quick Guide Lite This guide quick re ference fo r Lite installation . can be mounted on wall or on pole. is a Flexi BTS 1900 (FQF A) and 2100 (FQGA) , cabling, and maintenance Flexi BTS a a Lite Grounding Cabling rule for interfaces SFP cabling  Antenna ca bling Power cabling 1  Contents of delivery and needed tools Clearances  2  Preparing installation  Wall installation  4 Pole installation  5  3  12  11  8  7  6 Mounting bracket assembly Optional stacked installation Cabling Front cover installation Optional items installation Powering up and commissioning Installation check list  10 Deploying in small space (special case)  9  Maintenance

Transcript of flexi_lite_quick_guide-0900d80580a0ba9f.pdf

  • Flexi BTSQuickGuide

    Lite

    Thisguide quickreferencefor Liteinstallation .

    canbemountedon walloron pole.

    isa Flexi BTS1900(FQFA)and2100(FQGA),cabling,andmaintenance

    Flexi BTS a aLite

    GroundingCablingruleforinterfacesSFP cablingAntennacablingPowercabling

    1Contentsofdelivery andneededtools

    Clearances2 Preparinginstallation Wallinstallation4

    Poleinstallation5

    3

    12

    11

    8

    7

    6

    Mountingbracketassembly

    Optionalstackedinstallation

    Cabling

    Frontcoverinstallation

    Optionalitemsinstallation

    Poweringupand

    commissioning

    Installationchecklist

    10Deploying

    insmallspace(specialcase)

    9 Maintenance

  • -2-

    Theinformationinthisdocumentissubjecttochangewithoutnoticeanddescribesonlytheproductdefinedintheintroductionofthisdocumentation. ThisdocumentationisintendedfortheuseofNokiaSolutionsandNetworkscustomersonlyforthepurposesoftheagreementunderwhichthedocumentissubmitted,andnopartofitmaybeused,reproduced,modifiedortransmittedinanyformormeanswithoutthepriorwrittenpermissionofNokiaSolutionsandNetworks. Thedocumentationhasbeenpreparedtobeusedbyprofessionalandproperlytrainedpersonnel,andthecustomerassumesfullresponsibilitywhenusingit.NokiaSolutionsandNetworkswelcomescustomercommentsaspartoftheprocessofcontinuousdevelopmentandimprovementofthedocumentation.Theinformationorstatementsgiveninthisdocumentationconcerningthesuitability,capacity,orperformanceofthementionedhardwareorsoftwareproductsaregiven"asis"andallliabilityarisinginconnectionwithsuchhardwareorsoftwareproductsshallbedefinedconclusivelyandfinallyinaseparateagreementbetweenNokiaSolutionsandNetworksandthecustomer.However,NokiaSolutionsandNetworkshasmadeallreasonableeffortstoensurethattheinstructionscontainedinthedocumentareadequateandfreeofmaterialerrorsandomissions.NokiaSolutionsandNetworkswill,ifdeemednecessaryNokiaSolutionsandNetworks,explainissueswhichmaynotbecoveredbythedocument.NokiaSolutionsandNetworkswillcorrecterrorsinthisdocumentationassoonaspossible.INNOEVENT WILL NOKIA SOLUTIONS ANDNETWORKSBELIABLEFORERRORSIN THISDOCUMENTATIONORFOR ANY DAMAGES,INCLUDINGBUT NOT LIMITED TOSPECIAL,DIRECT,INDIRECT,INCIDENTAL ORCONSEQUENTIAL OR ANY LOSSES,SUCH ASBUT NOT LIMITEDTOLOSSOFPROFIT,REVENUE,BUSINESSINTERRUPTION,BUSINESSOPPORTUNITYORDATA,THAT MAY ARISEFROM THEUSEOF THISDOCUMENT OR THEINFORMATIONINIT.

    NSNisatrademarkofNokiaSolutionsandNetworks.NokiaisaregisteredtrademarkofNokiaCorporation.Otherproductnamesmentionedinthisdocumentmaybetrademarksoftheirrespectiveowners,andtheyarementionedforidentificationpurposesonly.

    Copyright201 NokiaSolutionsandNetworks. Allrightsreserved

    DN09145917Issue0 , Approvaldate201 - -

    4

    2 4 07 04

  • W Riskofeyedamagecausedbyinvisiblelaserbeam.ARNING!Dangerofeye damagecausedby invisiblelaser beam!Make sure thatthelaser beamis switchedoffwhenoptical cables areinstalled.

    NOTICE: appropriateingressU 6 SN

    requiredforboth and

    Incorrectcables andseals may notprovide protection.se only tested IP 5class outdoorcables withseals provided by N .

    This is indoor installations .

    Electrostatic discharge(ESD)may damagethemodules.WearanESDwrist strap oruse acorrespondingmethodwhenhandlingthemodules.NOTICE

    NOTICE

    NOTICE

    NOTICE

    NOTICE:

    :

    :

    :

    :

    r

    50/ 1.97/ 76

    Installing andcommissioning ofBTSproducts must beperformedby anexpertfamiliarwithelectronic devices, toavoid damagecausedby improperhandling.

    Overbending theoptical fibe cables damages thecables andcan detachordamagetheconnectors. Donotbendoptical fibrecables toaradiussmaller thantheminimumradius of 70mm( 2. inches).

    Theoptical fibreconnectoris fragile.Handleitwithcare.Always routetheoptical cables totheleftfromtheconnector.Donotconnectoptical cables inatemperaturelowerthan-20C.

    Optical fibres aresensitive. Thepresenceofcontaminants willlowerthemechanicalstrength oftheoptical fibreandmay dampenthetransmission oflightinthefibres. Cleanalloptical fibreconnectors beforeinstallationusing anoptical fibreconnectorcleaning kit.

    ,including theoutdoorcabinetoutdoor

    WARNING!Riskofelectricshock.BeforeturningRFpoweron,RFportsshouldbeterminatedbynominal50 load(forexample,feederwithantenna).However,iftheseconditionsarenotmet,theplasticcapsthataredeliveredwithintheunusedRFportsshouldremaininplace.TheplasticcapsisolateRFpowerfromtheenvironment,andthusprovideelectricshocksecurityincaseRFpowerisaccidentallyon.

    CAUTION! personalinjuryRiskof .Always stop transmission beforedetaching theoptical fibefromanoptical fibreconnectormarked withawarningtriangle.

    r

    -3-

    Deliveriesarecomplete andequipmentisnotdamaged.

    Contentsofdelivery andneededtools1

    Checklist

    DeliveryContens Salescode

    FlexiLite2100(FQGA) 472467A

    Optionalitems

    Mountingbracket 472469A

    Optional2100Internal

    Antenna(FAGQ)

    472590A

    Topcover 472470A

    Neededtools

    TORXscrewdrivers:T10,T15,T20,

    T25,T45Flat-headscrewdriverSocketoropen-endedspanners

    (wrenches):13mm(1/2in.),

    19mm(13/16in.)

    Torquewrenchforantennacables

    Cableties

    Drill

    Marker,pen,orcomparabletool

    Level

    Allen(Hexagon)key8mm(5/16in.)

    ESDwriststrapandcable

    FlexiLite1900(FQFA) 472751A

    Optional1900Internal

    Antenna(FAFQ)

    473019A

  • 4 Wallinstallation

    Preparinginstallation3

    Clearances2

    Fixingstuds

    a) b) c)

    Fixingstuds

    Mountingbracketassembly

    Fixthetwobracketpartstogetherandscrewinthefourfixingstuds.Therearethreewaystoconnectthebracketparts:

    a)

    b)

    c)

    Middleposition-usedinthedocument

    Shortposition-recommendedforpoleinstallations

    Longposition

    - -4

    Checklist

    Sitemeetstheminimumclearances.

    Markinganddrillingholes

    185mm(7.3in.)

    *)

    1

    *)

    1.Mark onthewallusingthebracketasatemplate

    rilltheholes.*) Thedistancebetweenupperandlowerholesdependson chosenbracketconnectionlength.

    thelocationsofmountingholes.

    .2.Notethattheupperpartoftheholedefinesthemaximumfixingscrewsize.3.D

    the

    Marktheupperholesfirst

    T

    a

    t

    hefixingmethodmustbesufficientto

    keeptheunitatitsposition. Alwayschoose

    methodandfixingscrewsthatare

    adequateothesurface

    constructiontype/material.

    CAUTION! personalinjuryRiskof .

    185mm(7.3in.)

    C andfixingpointslearances

    Top

    Left

    Walls/roofs/floors/otherobjects

    Right

    CAUTION!personal

    injuryRiskof

    .

    Ensurethat installation

    surfaceandselectedfasteners

    can deviceunder

    requiredcircumstances

    thewall

    sustainthe

    the .

    L =431mm(16.97in.)

    2

    3

    NOTICE: Theunitcoolingairflow

    goesfromtheleft-handsideto

    theright-handsideoftheunit.

    unitis

    installedinaroomthatenables

    properventilation.

    Makesurethatthe

    Bottom

    *200mmneededforfans'maintenancewhenmoduleisinitsinstallationposition

    **60mm(2.36in)istheminimumwheninstallinginasmallspace(specialcase)

    Middle

    and

    long

    position

    Short

    position

    Cabinet

    installa-

    tion

    Left*

    50mm

    (1.97in.)

    50mm

    (1.97in.)50mm

    (1.97in.)

    Right

    50mm

    (1.97in.)

    50mm

    (1.97in.)

    Top50mm

    (1.97in.)

    20mm

    (0.78in.)

    Bottom**

    200mm

    (7.87in.)

    200mm

    (7.87in.)

    200mm

    (7.87in.)

    Mounting

    bracket

    assembly

    positioning

    50mm

    (1.97in.)

    50mm

    (1.97in.)

  • Fixingmoduletothebracket

    1.Connectthemodulewithbracket. Aligntheholesonmodule'sbacktothefixingstudsonmountingbracket.

    2.Pushthemoduledownuntilitstops3.FixthefourM8x12screws.

    .Connectthewrist rap.

    .

    4.FixthetwoM5(T25)screwsbythefrontpanel.5 st

    1 2

    1

    Placingmoduleonawall

    1. .2.L andpositionitagainstthewall, ting on3.4.

    Fixtheuppermountingscrewsiftthemodule

    fit it thescrews.Tightentheupperscrews.Insertthelowerscrewsand

    tightenthem.

    -5-

    2

    3

    4

    4 Wallinstallation(continued)

    Checklist

    Moduleisfirmlyandproperlyfixedtothesurface.

    ESDwriststrapisconnected.

    3

    Wriststrap

    toESDstud

    54

  • Stackedinstallationonawall (Optional)4- -6

    Poleinstallation5

    1.FixthemoduletothebracketasinFixingmoduletothebra ket .2.Threadthejubilee throughthemountingbracketsholes.3.Lift unit thepole

    ightenthejubileeclips usingaflat screwdriver.

    sectionc onpreviouspage

    clips

    the on .

    NOTE:Fixtworopestothehoistingpoints(oneropeoneachsideofthebracket)andconnecttheminthemiddle,thattheyformatriangle. Thisallowsforabalancedlifting.Liftingtheunitwithonlyonehoistingpointisalsopossible,butinsuchacasetheunitisoutofbalance.

    4. T to5Nm(3.7lbft)-head

    2

    1 3 4

    Shortpositioninstallationonawall (Optional)4

    1.Knockout holes.

    2Screwfourfixingstudstothetopcover .

    3.FitthesecondFQGA module.

    4.FixthesecuringM screws.

    allthe 'blindsusingaflat-headscrewdriver

    .ofthefirstunit

    tothestudsandpushitdownfirmly

    4

    43

    2

    1

    1a1b

    1c

    1d

    3

    1.Setthemountingbrackettoitsshortposition.Fixthebracket.a. .b.Pc.d.

    2. k thethe

    3. .4.FixthetwoM5(T25)screwsbythefrontpanel.

    Fixtheuppermountingscrewsositionthebracketagainstthewall,fittingittothescrews.

    Tightentheupperscrews.Insertthelowerscrewsandtightenthem.

    Connectthemodulewithbrac et. Aligntheholesonmodule'sbacktothefixingstudson mountingbracket.Pushthemoduledownuntilitstops

    NOTEUsethemodulefrontbracketsashoistingpoints.

    :

    2

    4

  • 6 Cabling

    1.Connectthegroundingcabletothegrounding

    pointandscrew withM5(torx25)screw.

    2.(Optional)Securethecablewithacable .

    itin

    tie

    1.RemovetheIP seal

    2.Insert SFP transceiver.

    3.Connect opticalcable.

    4

    .Routethecabletotheleftandsecureitwith

    dedicatedNSNstrainrelief.

    .

    the

    the

    .

    5

    a Usea T20

    screwdriver.

    Pushtheconnectorsealfirmlyinplace.

    1.Removethecoveringcaps.

    2.Connectantennacables

    3.Tightenthe to Nm( . lbf)

    .

    cables 1.2 089 t .

    1

    2

    1 2 3

    Cleanwithswaborwipe alcohol.s with

    Grounding

    Opticaltransmissioncabling(SFP)

    NOTICE:Makesurethattheopticalcableconnectorshavebeencleaned.

    NOTICE: Useonlystraightorleft-bentopticalcablesandalwaysroutethecablesleftwards.

    NOTICE:Donotbendopticalcablesbeyondtheminimumradiusof

    70mm:

    - (2.76in.),whencablediameteris7mm(0.28in.)-50mm(1.97in.),whencablediameteris5mm(0.20in.)

    Antennacabling

    1 2 3

    -7-

    Theopticalcableconnectorsarecleaned.

    Theopticalcableisproperlyinstalledandtheminimumbendingradiusisnotviolated.

    Doublecheckthat correctopticalinterfaceisinstalledthe .

    4

    5

    1.RemovetheIP seal.

    2.Putthecablefirmly (forLMP and TRStillitclicks)

    3.Pushtheconnectorsealfirmlyinplace.

    in .

    22

    1

    3

    CablingruleforEAC,LMP,TRS,andSYNC

  • Checklist

    Powersupplywiresareconnectedcorrectly.

    Powersupplycableisconnectedandsecuredcorrectly.

    Cabling (continued)6

    Strainreliefbar

    I the

    (T15)

    nstall strainreliefbarandscrewitwithtwo

    M5 screws.

    ACpowercable

    20m

    m(0

    .79in.)

    1 2

    4

    5

    7

    8

    1.RemovetheIP bootfromthemodule.

    2.ThreadthecablethroughtheIP boot.

    Stripthecableshieldingandpeelthewires

    (NOTE: shouldbelongerthanothers)

    .Insertwires tothe ACinputconnector

    3. .

    groundingwire

    4 in .

    (N-Neutral,PE-Earth,L -Line)

    -8-

    WARNING!Riskofpowersupplyfailureand,inrarecases,ofshortcircuit.Checkthatthepolarityiscorrectaccordingtothemarkingsonthecable.

    .Threadthecablearoundthestrainreliefbarand

    throughthestrainreliefclamp eave 20 m

    fthecable .

    .Fixtheclamp'sscrews.

    .Insert ACinputconnectorandfixitsscrews.

    .PushtheIP bootfirmlyinplace.

    5

    ;l about 0m (7.87in.)

    o forconnectionpurposes

    NOTE:themaximum ACwirecross-sectionalareais

    2.5mm (AWG3).

    6 Usea T10screwdriver.

    7

    8

    2

    6

    3

    N PE L

  • Cabling(continued)6

    Securingcables

    Installingthefrontcover

    Frontcoverinstalling

    Frontcovermaintenance traps

    7

    -9-

    1

    3

    1.

    .

    2.

    3.Fixthecoverwithwo

    screws .

    Fittheupperpartofthecover

    tothemodule

    Swingthecoverandpushitfirmly.

    pre-installed

    (T15)

    3

    1.Tiethetworopestocreat

    maintenance trap.

    2. Threadthe traparoundthe

    strainreliefbar.

    3.Fix tohefrontcover.

    e

    a s

    s

    thestrap t

    2

    Securethecableswith

    cableties,ifneeded.

    Ensurethatthecable

    routingallowsforproper

    frontcoverinstallation.

    Checklist

    Cablesarethreadedinawaythatdoesnotobstructinstallationofthefrontcover.

    Frontcoveranditsmaintenancestrapareinstalledproperly.

    2

    NOTE:Beforefixingmake

    surethatthewashersare

    atthebottomofthescrew.

    Otherwise,fixingthescrews

    maybedifficult.

    2 3

    1

  • Installingoptionalitems8

    Antenna

    -10-

    1.Removethetopandfrontcovers,if

    theyarealreadyinstalled.

    2.Knockout screwhole

    nsert studs holes.

    .Fixtheantennascrews .

    .Fixtheantennacables.

    .K theupperpartofthefront

    cover.

    .Installthefrontcover.

    thesix blinds.

    3.I the inthemiddle

    4 (Torx15)

    5

    6 nockout

    7

    1

    2

    6

    7

    3

    4

    4

    5

  • Replacingfans

    1.Removesixscrewsfromthefanplate.

    2.Removethefanplate.

    3. Takeanewfanplateandconnect

    ans cables.

    4.Pla e newplateandfixit

    withthescrews.

    thef

    c the

    3

    1

    4

    1.Installthemaintenance trapasdescribed

    inchapter ront over.

    2.Fixthetwo orx .

    s

    Installingthef c

    screws(T 15)

    Maintenance9

    Installingoptionalitem (continue )s d8

    2

    NOTICE: akesurethattheconnectorsarefacingeachotherproperly

    M

    (seemarkingsontheconnectors).Improperconnectionmightcauseafanfailure.

    Topcover

    - -11

    1

    22

    NOTE:Ifthereisatleast200mm(7.87in.)

    maintenancespace,theprocedure

    canbedonewithoutuninstallingthemodule.

  • 1.PowerupFlexiLiteBTSandchecktheLEDstoensurethatthemoduleworksproperly.2.CommisiontheBTS.Seethe forfurtherinformation.CommissioningFlexiLiteBTS

    Poweringupandcommissioning

    10

    Installationchecklist

    Performthesecheckstomakesurethattheinstallationiscomplete.

    Thegroundingcableisconnectedtoagroundingpoint.

    Allthecablesareproperlyinstalled(andsecured,ifneeded).

    Siteiscleanandistallationiscompleted.

    Deliveryiscompleteandundamaged.

    Sitemeetstheminimumclearances.

    Module'scover(s)is(are)installedwiththemaintenance trap.s

    Themodule(s)is(are)correctlyinstalledonawall/pole.

    12

    -12-

    11

    Deployinginsmallspace(specialcase)

    1.Dothecablingfirst,thenattachthemoduletothemountingbrackets(middleposition).2.Installtheunitinplace.Handlethecableswithcareinordernottobreakthem.3.Routeallthecablestotheleft.Minimum60mm(2.36in.)spaceatthebottomoftheunitisneededforcablerouting.

    NOTICE:Donotbendopticalcablesbeyondtheminimumradiusof70mm

    :- (2.76in.),whencablediameteris7mm(0.28in.)-50mm(1.97in.),whencablediameteris5mm(0.20in.)

    Thespecialcasecanbeappliedwhenthereisaverylimitedspaceandyoucannotmeettheregular200mm(7.87in.)unitbottomclearance.