FlashSystem family 2014 © 2014 IBM Corporation IBM® FlashSystem™ V840 Product Overview.
-
Upload
dylan-sullivan -
Category
Documents
-
view
231 -
download
1
Transcript of FlashSystem family 2014 © 2014 IBM Corporation IBM® FlashSystem™ V840 Product Overview.
FlashSystem family 2014
© 2014 IBM Corporation
IBM® FlashSystem™ V840Product Overview
© 2014 IBM Corporation2
IBM FlashSystem V840
• A fully featured and scalable all-flash architecture that performs at up to 2.5M IOPS with IBM MicroLatency™ and up to 1.6PB effective capacity
• Delivers better acquisition costs than high performance spinning disk for the same effective capacity while achieving 5x the performance
• With IBM’s Real-time Compression™ technology IBM FlashSystem V840 further extends the economic value of all-flash systems
IBM Flash has reached the tipping point and is now cheaper than disk.
© 2014 IBM Corporation3
IBM FlashSystem V840
Extreme Performance Macro Efficiency Enterprise Reliability
• Scalable to 2.5 million IOPS• Scalable to 19.2 GB/s• Mixed Workload
Consolidation
• Advanced Data Services• Copy Services, mirroring,
replication, external virtualization, VAAI
• Concurrent code load• Hot swappable architecture• AES 256, HW-based encryption• Fully redundant controllers
• Scale up to 40TB usable and up to 200TB effective capacity in only 6U
• Scale up to 320TB usable and up to 1.6PB effective capacity in only 36U
• Effective capacity possible with optional Real-time Compression
•IBM Real-time Compression•IBM Easy Tier®•Thin provisioning
•Copy services•Data Virtualization•Highly available
configuration
Accelerate applications with enterprise-class, advanced storage capabilities
IBM MicroLatency™
• 200 µs response time • Flash-optimized design
© 2014 IBM Corporation4
Scalable Building Block (Plan for growth)
IBM FlashSystem V840
Scale-up (add capacity)
Scale-up and Scale-outConfiguration
Maximum Performance – Fixed Build Block(100% Read, Cache Miss)Latency (4K) 200µsIOPS (4K) 526,000Bandwidth (128K) 6.2 GB/s
Maximum Performance – Scaled Out (100% Read, 4 Building Blocks) *Latency (4K) 200µsIOPS (4K) 2,520,000Bandwidth (128K) 19.2 GB/s
Maximum Performance – Scalable Build Block (100% Read, Cache Miss)Latency (4K) 200µsIOPS (4K) 630,000Bandwidth (128K) 6.2 GB/s
© 2014 IBM Corporation5
IBM FlashSystem V840
Flash for Less Than Disk
Enable Mixed Workload Consolidation
Scale-up & Scale-out
Improve What You HaveIBM & non-IBM
Drive New Business Opportunities
Software Defined Services
Deep Application Integration
© 2014 IBM Corporation6
Thinprovisioning
Purchase only the storage you need
Dynamicgrowth
Software Defined Storage Services
High availabilityconfigurations
Thin Provisioning
More productive use of available storage
Across all supported host platformsWithout thin provisioning, pre-allocated
space is reserved whether the application uses it or not.
With thin provisioning, applications can grow dynamically, but only consume space
they are actually using.
Dynamicgrowth
Busiest data extents are identified and automatically relocated to highest performing Solid-state Disks
Remaining data extents can take advantage of higher capacity, price optimized disksHot-spots due to poor data layout. Optimized performance and throughput.
AutomaticRelocation
SSDs HDDs SSDs HDDs
IBM Easy Tier SSD Management
Mirror data off-site
Synchronously over Metro distances.
Asynchronously over Global distances.
Application-level consistency groups.Network
Enable continuous data availability
Copy Services Eliminate application downtime for backup
Test disaster recovery plans
Validate business continuity strategy
Software Defined Services
© 2014 IBM Corporation7
FlashSystem V840 Enables Mixed Workload ConsolidationEnables Mixed Workload Consolidation
99 percentreduction in average query
response
66 percentreduction in SAP ERP response
times
© 2014 IBM Corporation8
CPU Utilization & App. Efficiency
4%Total Application Processing Time 5,200us (5.2ms)
5,000us (5ms)
200us (.2ms)
Application Processing Time
Time Waiting for I/0(Waiting for Array)
Time Processing Data(Server CPU)
Disk/HybridSW-Based SSD
HW-BasedSolutions
CPU Utilization& App. Efficiency
50%Total Application Processing Time400us (.4ms)
200us (.2ms)
200us (.2ms)
What will you do with the Extra
Time?
FlashSystem V840 Makes Applications FasterEnable Mixed Workload Consolidation
© 2014 IBM Corporation9
Flash for Less Than the Cost of Disk
Tipping Point Economics• Low latency with high IOPS flash
replaces shelves of HDD and enables server consolidation
• Decrease storage TCO with lower space, power and cooling costs
ThinProvisioning
Purchase only the storage you need
Dynamicgrowth
Real-time Compression
Store up to 5X more data with less flash
Flash for Less Than Disk
© 2014 IBM Corporation10
FlashSystem V840 and VMware®: an ideal fit
Driving efficiency, performance, flexibility & scale in virtualized environments• Redefine Tier 1 performance for workloads with diverse I/O patterns
• Optimize your data tier with thin provisioning, snapshots, and real-time compression
Area Integration ValueManagement vCenter plug-in • Storage visibility
• Self-service provisioning with controlled delegation
Business Continuity
SRA for Site Recovery Manager
• Automated Storage and Host • Failover• Failover testing • Failback
Performance VAAI • Hardware accelerated VM copy/migration• Hardware accelerated VM initiation• Accelerate VMFS (no SCSI reservation)
Deep Application Integration
© 2014 IBM Corporation11
FlashSystem V840 and VDI Reduces Risk and Cost
Deep Application Integration
• Cuts CAPEX and OPEX Costs– Up to 20x more users on IBM
FlashSystem• Better-than-PC User Experience
– Faster-than-PC boot time– < 1 second app launches– Near-instant email/desktop searches
• Lower project risks– Scales to tens of thousands of virtual
desktops– Consistent better-than-PC performance– No hidden storage costs overruns
• Fast Provisioning and Better Management at scale
– Automated deployment with HA and DR
Hypervisor
IBM FlashSystem
Atlantis ILIO VM
Virtual Desktops
FlashSystem for VDI
© 2014 IBM Corporation12
FlashSystem V840 is Scalable with Flexible Deployments
Grow capacity and performance as needed
• Toggle compression on specific data sets • Customize automated tiering options on data sets • Extend advanced software functions to third party storage
Performance
Capacity
Scale-up & Scale-out
© 2014 IBM Corporation13
FlashSystem V840 Virtualizes IBM and Third Party Storage
Preserve your existing investment in storage Manage Tier Protect Compress with Real-time Compression
Optimized performance at lower overall cost
IBM Easy Tier® flash storage management
Thin Provisioning
More productive use of available storage
Across all supported host platformsWithout thin provisioning, pre-allocated
space is reserved whether the application uses it or not.
With thin provisioning, applications can grow dynamically, but only consume space
they are actually using.
Dynamicgrowth
Busiest data extents are identified and automatically relocated to highest performing Solid-state Disks
Remaining data extents can take advantage of higher capacity, price optimized disksHot-spots due to poor data layout. Optimized performance and throughput.
AutomaticRelocation
SSDs HDDs SSDs HDDs
IBM Easy Tier SSD Management
Mirror data off-site
Synchronously over Metro distances.
Asynchronously over Global distances.
Application-level consistency groups.Network
Improve What You HaveIBM & non-IBM Flash FlashHDDs HDDs
© 2014 IBM Corporation14
FlashSystem V840 Improves Your Business
Drive new business opportunities with IBM FlashSystem
Accelerate Infrastructure
Lower the Cost of Flash
Protect your Investment
Simplified ManagementEnable
Datacenter Consolidation
Run Mixed Workloads
AccelerateApplications
Improve Workforce
ProductivityDrive New Business Opportunities
© 2014 IBM Corporation15
For More Information and Education
Product Pages:– IBM FlashSystem 840 – IBM FlashSystem V840 – IBM FlashSystem EcoSystem
Resources: ibm.com/storage/flash/resources Workload Estimator Tool:
http://www.ibm.com/systems/support/tools/estimator Energy Estimator Tool:
http://www.ibm.com/systems/support/tools/estimator/energy .
Twitter: #FlashSystem, #IBMFlash
Website: ibm.com/storage/flash/