FIXED ACCESS LADDERS, ALUMINIUM 60x20IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS DIN EN ISO 14122-4: 2016Translation of assembly and operating instructions

Page 2: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

© Hailo Wind Systems – Without the prior written consent of Hailo Wind Systems, no part of this publication may be reproduced in any way, transmitted, transcribed, stored in a storage medium or translated into any language or computer language. Copyright infringement may also affect the product support by Hailo Wind Systems for this equipment. Hailo Wind Systems reserves the right to make changes to this manual and the product it describes without prior notice. The content of this manual does not include any contractual or other obligations by Hailo Wind Systems and is not legally binding. This publication was prepared with great care. However, should you find any errors or wish to make suggestions for improvement, please write to Hailo Wind Systems. The original language of this document is German. If required, you can request a written copy.

Hailo Wind Systems GmbH & Co. KGKalteiche-Ring 1835708 Haiger, GermanyPhone: +49 (0) 2773 82-1410Fax: +49 (0) 2773/82-1561E-Mail: [email protected]: www.hailo-windsystems.com

Revision and Changes08/2019 V01R06 EN

Page 3: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

3Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Contents

1. About this document 42. Standards and regulations 53. Safety 64. Markings and information 135. Transport and storage - Technical data 146. System overview 157. Assembly 18

7.1 General assembly instructions 187.2 Technical specifications 207.3 Wall brackets 307.4 Ladder connectors 327.5 Rung repair kit 367.6 Base anchor 377.7 Rest platforms 387.8 Equipotential bonding 40

8. Usage 428.1 Safety instructions 42

9. Inspection and maintenance 4410. Assembly log 4611. Log for inspection 50

Contents

Page 4: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

4 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

These assembly and operating instructions describe the installation, use, maintenance and testing of the aluminium access ladder system.

Please read these instructions in their entirety and observe all safety information before you begin assembly work and use the access ladder. In the event of damage resulting from non-observance of these instructions and the safety information, Hailo Wind Systems shall assume no liability.

These assembly and operating instructions are only valid for access ladder systems of Hailo Wind Systems.

NOTE!Product changes

Hailo Wind Systems reserves the right to make technical modifications and improvements which do not apply to the tested prototype.

Substantive changes to the technical documentation are reserved by Hailo Wind Systems.

Language of the manualiIf the climbing system is resold to a buyer in another country, it is necessary for the safety of the user that this manual be made available in the respective national language. Translations can be requested from [email protected].

1. About this document

Page 5: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

5Assembly and operating instructions • Fixed access ladders, aluminium 60x20

The access ladder system complies with the requirements of the following standards:

• OSHA 1910.23

• OSHA 1926.1053

• ANSI 14.3 (Parts)

• EN ISO 14122-4: 2016Safety of machinery - Fixed accessing of machine installations - “Fixed access ladders”

• BGV / GUV-V A1 Basic principles of prevention

• DGUV 208-032 Selection and use of access ladders

• DGUV 312-906 Selection, training and certifying the capability of experts on personal fall protection equipment

• DIN EN 50308Wind turbine generators - protective measures - requirements for construction, operation and maintenance

• Requirements for fall protection According to DIN EN ISO 14122-4: 2016, a falling height ≥ 3 m requires fall protection.According to DIN EN ISO 14122-4: 2016, for climbing heights over 10 m and a single strand version of the ladder, only fall protection conforming to DIN EN 353-1: 2018 is permitted.

• Fall protection requirements The fall arrest system must comply with DIN EN 353-1: 2018. The access ladder shall be equipped with a fall arrest system including a fixed guide. Observe national regulations.

• Ordinance for entry and exit on access ladders with a fall arrest systemThe fall arrester and its surroundings must be arranged so that users attach or release themselves from a secured position, for example, through the provision of an attachment point conforming to DIN EN 795 or a trapdoor, which leads to a completely protected platform with self-closing barrier gate according to DIN EN ISO 14122-3:2016, 7.4.

2. Standards and regulations

Page 6: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

6 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Intended use

The fixed access ladder is specially designed for use in wind turbine generators and machine installations. It is used to ensure the safe ascent and descent of service personnel from workplaces at height.

To this end, users connect with their Personal Fall Protection Equipment (PFPE) to the existing fall arrest system, which runs along the entire length of the climbing equipment. Without the protection of the user, e.g. on the fall arrest system, the climbing equipment may not be used.

The employer or operating company of an installation must provide a plan in which all possible emergencies that can occur when using the access ladder system are taken into account and the necessary rescue measures are explained.

The fixed access ladder may only be used in perfect condition.

These assembly and operating instructions must be observed by all persons who install and use the access ladder.

The fixed access ladder may only be installed by trained persons. The precondition for safe handling as well as faultless assembly and use of the access ladder is compliance with the safety instructions and regulations.Structural modifications are only possible after receiving approval by Hailo Wind Systems. A copy of the approval must then be added to the technical documentation (manual).

The fixed access ladder may only be used by persons who have been instructed in the use of the access ladder and fall arrest system, and who are familiar with the safety plan in the wind turbine generator or machine installation. This includes any required rescue measures, their introduction and implementation. The accident prevention regulations applicable to the respective installation site as well as the safety regulations listed here are to be followed.

The entity operating the wind turbine generator must secure the climbing equipment against entry by unauthorised persons.

3. Safety

Page 7: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

7Assembly and operating instructions • Fixed access ladders, aluminium 60x20

The climbing equipment may only be used for its intended purpose.

Non-intended use is prohibited and may lead to failure of individual components and thus to failure of the entire system.

The climbing equipment may not be used in the following cases:

• Improper assembly

• Safety defects or improperly performed repairs

• Unauthorised or unapproved modifications to the climbing equipment

• Use of any parts other than genuine spare parts

• Insufficiently qualified personnel

• Unfamiliarity with or non-observance of these assembly and operating instructions

• Inadequate maintenance and care or neglect of timely inspection of the access ladder system

No liability will be assumed for harm to persons or damage to equipment arising from violation of the provisions stipulated here or non-observance of the safety instructions.

Page 8: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

8 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

CAUTION!

CAUTION indicates a possible dangerous situation which could lead to minor injuries if not avoided.

WARNING!

WARNING indicates a possible dangerous situation which could lead to serious injuries or death if not avoided.

Safety instructions

Classification of the safety instructions

The safety instructions in the manual serve as notices and precautions which must be observed or undertaken to prevent dangerous situations from arising.

This manual contains four classes of safety instructions with highlighting of useful and important information (tips/info).

A distinction is made between:

DANGER!

DANGER indicates an imminently threatening dangerous situation which could lead to serious injuries or death if not avoided.

NOTICE!

NOTICE indicates a possible dangerous situation which could lead to property damage if not avoided.

Tip / Information

This symbol is used to draw your attention to important or helpful information.

3. Safety

i

Page 9: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

9Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Before assembling and using the climbing equipment

NOTICE!Property damage possible due to non-compliance with the instructions

For this reason, observe the following:• Before assembly and use of the access ladder system, the instructions must be read

carefully and heeded.• The assembly and use of the access ladder system with fall arrester may only be

performed by personnel who have been instructed and authorised by the manufacturer.• The operator must ensure that these assembly and operating instructions are stored

with each access ladder system on-site and are available to personnel.

CAUTION!

Always carry a communication device (mobile phone, radio unit)When in or on the wind turbine generator, constant voice contactmust be ensured between the involved persons. Ensure contactbetween persons using mobile phones or radios.

Put on personal fall protection equipment (PFPE)Protection against falls from above a minimum height.

Wear a helmetHead protection from falling objects and impacts from falls or in confined spaces.

Wear safety footwearFoot protection for heavy falling objects, slipping, steppingon sharp-edged parts that are lying around.

Wear safety glovesProtect hands from friction, abrasions, stabs and cuts.

Page 10: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

10 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Warnings

DANGER!Danger of falling!

Disregarding the safety instructions may result in a fall and thus lead to serious injury or death.

For this reason, observe the following:• Before using the climbing equipment, protect yourself using personal fall protection

equipment (PFPE) with the intended fall arrest system.

• The personal fall protection equipment must be properly selected, used and checked.

• In icy conditions, use of the access ladder system is prohibited.

• In pylon towers, the use of the climbing equipment is also prohibited in the case of extreme temperature and weather conditions (e.g. hail, strong wind, snow and ice).

• Do not use the climbing equipment if you feel unwell or are in poor physical condition.

• It is important to ensure that no devices or objects are located below the climbing equipment that could represent an additional hazard in case of a fall.

• The treading and climbing surfaces must be free of oil, grease or other lubricants.

• Do not exceed the maximum permitted payload of 150 kg in a ladder section between two wall brackets.

• The system or components of the system are to be withdrawn from use immediately if there are doubts about their safe condition.

3. Safety

Page 11: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

11Assembly and operating instructions • Fixed access ladders, aluminium 60x20

DANGER!Risk of injury from electric shock!

Improper operation may cause serious injury or death.

For this reason, observe the following:• The climbing equipment (ladder) must be grounded along its entire length

(equipotential bonding)!

• The climbing equipment must not come into contact with electrical cables or components that are damaged or are not suitably insulated.

WARNING!Risk of injury due to improper use!

Improper operation may cause serious injury or property damage.

For this reason, observe the following:• The climbing equipment may only be used by trained personnel.

• Damaged components may only be replaced by specialist personnel (authorised by the manufacturer) and using genuine parts. A change or extension of the access ladder system may not be undertaken without the explicit prior written approval of the manufacturer. A copy of the approval must then be added to the technical documentation (manual). Any necessary repairs must be carried out in accordance with the procedures specified by the manufacturer.

• Never disable the safety equipment.

• Pay attention to orderliness and cleanliness! Loosely stacked or scattered objects such as tools, cables and components are sources of accidents.

Page 12: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

12 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Property damage possible due to non-compliance with safety instructions

Comply with the safety regulations for wind turbine generators as well as the instructions issued by the manufacturer of the installation.

NOTICE!Deadlines for testing and maintenance

The prescribed intervals for recurring inspections/maintenance must be adhered to!

The proper condition of the climbing equipment and the attachment points must be checked at least once a year by a competent and qualified person.The check list for the inspection can be found in the appendix to these instructions.

NOTICE!Language of the manual

If the access ladder system is resold to a buyer in another country, it is necessary for the safety of the user that this manual be made available in the respective national language. Translations can be requested from [email protected].

3. Safety

Page 13: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

13Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Access ladder type plate

• Manufacturer, year built, type designation

• Material and dimension specifications

• Instructions for loads placed on the access ladder

NOTICE!Labels on the fixed access ladder

Pay particular attention to all labels or stickers with safety instructions.

4. Markings and information

Ladder identification plate

• Instructions for the fall arrest system

• Inspection stickers for the yearly inspection by an expert

• Instructions for loads placed on the access ladder

Page 14: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

14 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

All parts of the system must be secured so that no impairment of their function occurs and all components are perfectly safe.

• Move and load components of the access ladder system with caution.

• To avoid damage, do not turn the ladder components on their edges during transport and storage.

• Do not place additional loads on system components during transport and storage.

Transport and storage

• During transport and storage, protect components of the access ladder system against wetness, exhaust gases, chemicals or other harmful substances.

Prior to assembly of the access ladder system, all components are to be inspected to ensure they are in flawless condition. System components must be free of any transport damage. Damaged parts are to be replaced prior to assembly.

Technical data

• The permitted temperature range for use of the access ladder is between -40 °C and +60 °C.

• The permitted storage temperature lies between -40 °C and +60 °C.

5. Transport and storage - Technical data

Page 15: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

15Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Ladders with fall protection rail (DIN EN 353-1: 2018) and rest platform

Ladder fastenings

Scope of delivery

All illustrations are examples and deviations from the depictions may arise, depending on the version.

• Aluminium access ladder• Rail profile: 60 x 20 mm

Mounting of the ladder by means of ladder clamps

Mounting of the ladder by means of ladder brackets with rung adapters

6. System overview

i

Mounting of the ladder with threaded rod through rung

Mounting of the ladder rung with U-bolt

Page 16: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

16 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Ladder joints

External rail connector

Internal rail connectorAluminium60 x 20 mm

6. System overview

Section rail connector

Page 17: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

17Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Rung repair kit

Base anchor with rail clamp

Base anchor on the ladder rung

Rest platform

Rung repair kit

Base anchors

Rest platform with divided treading surface

Rest platform SP 305x140

Page 18: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

18 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Proof of load bearing capacity

• Prior to beginning the assembly, it must be checked that the expected loads can be borne by the supporting structure. If no relevant information and documentation is available for this, a structural certification must be produced, which takes the required load bearing capacity into account.

• If the necessary certifications are not on record documenting a safe absorption of forces on the supporting structure, Hailo Wind Systems shall assume no liability for cases of damage.

Assembly personnel • The personnel handling the assembly of the access ladder system must be qualified, competent and have received the respective training. More detailed information on service trainings can be found under www.hailo-windsystems.com/sara.

Safety of assembly personnel

DANGER!Danger of falling!

When performing assembly work at height, falling can lead to injuries.

For this reason, observe the following:• Always use your entire PFPE!

• Use an approved fall protection system during assembly.

• Use an approved attachment point as specified in DIN EN 795 or CEN/TS 16415.

• The assembly personnel may not be secured to the system to be installed.

7. Assembly

7.1 General assembly instructions

Page 19: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

19Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Assembly and repairs

• Use only clean and undamaged system parts.

• Damaged parts must be replaced with new original parts. This may only be carried out by specialist personnel (authorised by the manufacturer). Any necessary repairs must be carried out in accordance with the procedures specified by the manufacturer.

• A change or extension of the access ladder system may not be undertaken without the explicit prior written approval of the manufacturer. A copy of the approval by Hailo Wind Systems must then be added to the technical documentation (manual).

Assembly log • The assembly of the access ladder system must be fully documented by the assembly manager of the assembly company.

• You must fill out the assembly log completely in the last chapter of these instructions.

General assembly instructions

Assembly specifications • The design and version of the climbing equipment must conform to the standard DIN EN ISO 14122-4: 2016.

Specification of tightening torques

• Example of a tightening torque specification:

Thread dimension

ST: SteelVA: Stainless steel

Tightening torque

Page 20: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

20 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Spacing of the anchoring points for wall brackets

• The expected loads must be distributed safely onto the supporting structure over at least four anchoring points per ladder, or at least two per side rail. The anchoring points must be arranged in pairs at a single level.

• When setting the anchoring points, Hailo Wind Systems recommends that a vertical distance of 2000 mm not be exceeded. For a rung spacing of 280 mm, a distance of 1960 mm is suitable.

• Larger distances are to be agreed in advance with Hailo Wind Systems.

NOTICE!Specifications when using a fall arrest system

• When using a fall arrest system according to DIN EN 353-1: 2018, the static loads of 15 kN are to be taken into account.

• When using a fall arrest system, the country-specific regulatory requirements are also to be observed.

7.2 Technical specifications

Loads to be transferred • The anchoring points and their connections (brackets, fixing devices) must be capable of bearing the respective loads.

• The loads of 15 kN per wall bracket spacing (7.5 kN per side rail) must be taken into account. This corresponds to a load of up to 3.75 kN per anchoring point.

• Other factors to consider include: weight of the access ladder installation, maximum number of persons in the climbing equipment, load in the event of a fall.

7. Assembly

Page 21: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

21Assembly and operating instructions • Fixed access ladders, aluminium 60x20

First wall bracket • The fit of the first wall bracket pair depends on the type of ladder fastenings.

• The specifications can be waived if the ladder is fixedly bolted to the ground with a base anchor.

Ladder fastening with rail clamps

• The first wall bracket is attached under the first rung, between the first and second or between the second and third rung.

Ladder fastening with rung adapter and fixing with threaded rod through the rung

• The first wall bracket is attached on the first or second rung.

Technical specifications

Page 22: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

22 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Last wall bracket • The fit of the last wall bracket pair depends on the type of fall arrest system used and the type of ladder fastenings.

• Larger distances between the last wall bracket pair and the end of the ladder must be agreed with Hailo Wind Systems.

Ladder fastening with rail clamps

• Rail-based fall arrester: The last wall bracket is attached above the first rung, between the first and second or between the second and third rung from the top.

7. Assembly

• Fall arrester with rope guide: The last wall bracket may lie maximally 280 mm under the end of the rail.

Page 23: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

23Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Ladder fastening with rung adapter and fixing with threaded rod through the rung

• Rail-based fall arrester: The last wall bracket is attached on the first or second rung from the top.

• Fall arrester with rope guide: The last wall bracket is attached on the first rung from the top.

Technical specifications

Page 24: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

24 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Ladder boarding dimension

• The distance between the entryway surface (e.g. the ground) and the upper edge of the lowest rung must be greater than 100 mm and less than 400 mm (per DIN EN ISO 14122-4: 2016).

• If a service lift of Hailo Wind Systems is operated on the ladder, the distance between the ladder rail end and the ground may not be more than 100 mm.

7. Assembly

Page 25: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

25Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Ladder exiting dimension

• The upper edge of the top rung must be at the same height as the stepping area of the exit surface.

Technical specifications

Wall clearance - Ladder exit

• If necessary, an exit extension should be attached. This is bolted with a rail clamp underneath the last rung. Deviating versions/sizes are possible.

Spacing dimension Wall brackets

Number of rungs of the exit extensions

165 - 215 mm 2

215 - 290 mm 3

290 - 365 mm 4

365 - 440 mm 5

NOTICE!Specifications for the wall clearance at the ladder exit

According to DIN EN ISO 14122-4: 2016:

• The distance between rung and stepping area at the ladder exit may be maximally 75 mm.

Page 26: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

26 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

7. Assembly

Elements for entering and exiting

• As a safety element for crossing over at the upper end of the climbing route, entry and exit elements can be used. At the ladder crossing point, an additional attachment point must be provided.

• If additional components such as entry and exit elements, railings, barrier gates, trapdoors or platforms are used, these must correspond to the standards (DIN EN ISO 14122-3: 2016 and DIN EN ISO 14122-2: 2016).

Short exit rail, material: stainless steel or galvanised steel

Long exit rail, material: stainless steel or galvanised steel

Page 27: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

27Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Technical specifications

Minimum tread depth and wall clearances

NOTICE!Observe the minimum tread depth

According to DIN EN ISO 14122-4: 2016:

a. The distance from the rung front edge to the fixing surface must be at least 200 mm.

b. In the case of obstacles (1, e.g. tower flange) behind the access ladder, the distance from the rung front edge to the fixing surface must be at least 150 mm.

c. The distance from the rung front edge to the surface in front of the access ladder (tower wall, for example) must be at least 650 mm.

d. In the case of obstacles (1) in front of the access ladder, the clearance from the rung front edge must be at least 600 mm.

a

b

c

d

Compatibility with service lifts

• All standard Hailo Wind Systems service lifts can be used on the ladders.

Page 28: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

28 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Equipotential bonding • Ensure that the climbing equipment (ladder) is earthed over its entire length (equipotential bonding).

Specifications for fixing onto the supporting structure

• The surface under the anchoring points on the supporting structure must be capable of bearing the loads listed above.

• Only approved anchor fittings may be used. This also applies to concrete supporting structures and masonry.

• In the case of undefined subsurfaces, the fixing system must be implemented in consultation with the structural engineer.

Suitable types of fastenings

• Threaded bushes M12 / M16 in steel structures

• Anchor peg fastenings on concrete supporting structures with a concrete quality of at least C 20/25.

• This must be agreed with the structural engineer.

• Observe the assembly instructions of the anchor manufacturer!

7. Assembly

Page 29: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

29Assembly and operating instructions • Fixed access ladders, aluminium 60x20

General screw tightening torques(providing they are not otherwise defined)

Screw sizes Tightening torque

M8 17.9 Nm

M10 36.0 Nm

M12 61.0 Nm

M16 147.0 Nm

M20 297.0 Nm

Steel screws Strength class 8.8

Screw sizes Tightening torque

M8 26.2 Nm

M10 53.0 Nm

M12 90.0 Nm

M16 216.0 Nm

M20 423.0 Nm

Steel screws Strength class 10.9

Max. tightening torques MA (Nm) with a total friction coefficient of μ=0.08 (μ=0.08 applies to a zinc-plated, non-oiled, dry surface).

Screw sizes Tightening torque

M8 14.5 Nm

M10 30.0 Nm

M12 50.0 Nm

M16 121.0 Nm

M20 244.0 Nm

Stainless steel screws A2 and A4

Strength class 70

Max. tightening torques MA (Nm) with a total friction coefficient of μ=0.10 (μ=0.10 applies to a non-oiled, dry surface).

Strength class 70 corresponds to a cold-pressed treatment up to nominal lengths 8 x d and using 90% (Rp 0.2) of the yield strength.

Technical specifications

Page 30: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

30 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Wall brackets with rail clamps

1. Bolt the wall brackets onto the supporting structure. As you do this, ensure that the rail clamps for the ladder mounting are pointed inward.

2. When all wall brackets are fastened, insert the access ladder between them.

3. Attach the rail clamps to the ladder and screw the ladder onto the wall brackets. Pay attention to the correct torques while doing so.

7. Assembly

7.3 Wall brackets

Sequence of assembly steps

The sequence of the assembly steps may vary, depending on the specifications of the WTG manufacturer.

i

Ladder bracket with U-bolt

1. Screw ladder bracket to load-bearing structure. In doing so, make sure that the lugs of the ladder bracket are directed inwards.

2. After all ladder brackets have been installed, place the ladder between the ladder brackets.

3. Guide U-bolt through the sleeves and enclose the ladder rung with it. Screw it to the lugs of the wall bracket with 15 Nm.

Page 31: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

31Assembly and operating instructions • Fixed access ladders, aluminium 60x20

1. Bolt the wall brackets onto the supporting structure. When doing so, ensure that the shackles of the wall bracket are pointed outward.

2. When all wall brackets are fastened, insert the access ladder.

3. Place the rung adapter around the ladder rung and fix it to the wall bracket with the U-bolt. Pay attention to the correct torque while doing so.

Wall brackets with rung adapter

Wall brackets

1. Bolt the wall brackets onto the supporting structure. When doing so, ensure that the shackles of the wall bracket are pointed outward.

2. When all wall brackets are fastened, insert the access ladder.

3. Guide the threaded rod through the rung and the elongated hole of the wall bracket. Insert a washer and screw the threaded rod tight. Pay attention to the correct torque while doing so.

Page 32: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

32 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

NOTICE!Specifications for internal rail connectors

• An internal rail connector is to be used exclusively for guiding the ladder rail. After installing, a length of 30 mm should be visible, providing the rung spacing has been correctly observed.

• A deviation of the rung spacings by ±15 mm is permitted only in wind turbine generators (EN 50308). Hailo Wind Systems recommends a maximum deviation of the rung spacing of ±2 mm.

• The internal connectors may not be cut off! When using a ladder-guided service lift, a maximum deviation between the rail ends of 2 mm during assembly must be observed.

Aluminium ladder connectors

Can be used in 60 x 20 mm rail profiles.

The installation depth of the connector is limited by the ladder rung. The rails are guided exactly over the surfaces of the internal rail connector.

1. Insert internal rail connectors up to the ladder rung in the ladder end.

2. Insert the ladder piece to be used until it reaches the stop on the internal rail connectors.

7. Assembly

7.4 Ladder connectors

Page 33: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

33Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Ladder connectors

External rail connectors

Threaded rod material: Stainless steel or galvanised steel, C-connector material: aluminium.

Available for 60 x 20 mm rail profiles.

1. Insert threaded rods into the ladder rung and centre with centring sleeves at both ends.

2. Place the C-profiles on both rails and screw them tight. Pay attention to the correct torque while doing so.

NOTICE!Distance between ladder rails

• The distance between the ladder pieces to be connected may extend to 30 mm, providing the specified rung spacing is observed.

• A deviation of the rung spacings by ±15 mm is permitted only in wind turbine generators (EN 50308). Hailo Wind Systems recommends a maximum deviation of the rung spacing of ±2 mm.

• The ends of the ladder may have sharp edges.

• Therefore, always wear protective gloves!

• The cutting edges (e.g. on rail ends) must be properly deburred.

CAUTION!Danger of cutting due to sharp edges!

Page 34: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

34 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Material: Stainless steel.Suitable for use in rail profile 60 × 20 mm.

The section rail connector enables the subsequent installation or replacement of an intermediate ladder piece, for example on a ladder with ladder-guided service lift.

1. Place the ladder ends flush against the rail surfaces.

2. Position the plate with screw sleeves vertically and horizontally in the centre of the ladder rails and fix with 2 screw clamps.

3. Through the drill sleeves, drill 4 holes (Ø 10 mm) in the ladder rail. Then loosen the screw clamps and remove the plate.

4. Drill the holes on the outside of the ladder rail to Ø 16.5 mm.

5. Install the section rail connector. Insert the plate with screw sleeves into the holes on the ladder rail from the outside. Place the second plate on the inside of the ladder rail and tighten the rail connector.

NOTE!Material damage is possible!

• Observe the dimensional specifications for the installation of an intermediate ladder piece!

7. Assembly

Page 35: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

35Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Ladder connectors

Material: Steel (galvanised).Available for rail profile 60 × 20 mm.

Hailo Wind Systems recommends the use of the mounting aid for the installation of the ladder. It facilitates the precise cutting and drilling of the respective components. The mounting aid can be ordered by writing to [email protected].

i Mounting aid

1. Place the mounting aid for cutting the ladder on the rail and fix into position (use a screw clamp if necessary).

2. Using the saw guide, saw through the ladder rail with a straight cut (90°). Repeat for the other three cuts.

3. Remove the cut-out ladder piece and insert a new, customised ladder piece. Place the mounting aid on the rail and fix into position (use a screw clamp if necessary).

Mounting aid

Page 36: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

36 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

7. Assembly

4. Insert the plate with screw sleeves into the mounting aid and use as a drilling guide.

5. Through the drill sleeves, drill 4 holes (Ø 10 mm) in the ladder rail. Then remove the mounting aid.

6. Drill the holes on the outside of the ladder rail to Ø 16.5 mm.

7. Attach the ladder connector.

Page 37: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

37Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Assembly situation Ladder intermediate piece in the flange transition

Preparation of the ladder intermediate piece for assembly on an existing access ladder in the flange transition area of a wind turbine generator.

1. Determine the spacing dimension of the ladder.

2. Saw the delivered ladder intermediate piece to the correct size with a gap of maximally 2 mm at the upper and lower ends. Perform the saw cut at a 90° angle to the ladder rail and then professionally deburr the cut surfaces.

3. With the aid of the rail section external connector or external rail connector, mount the ladder intermediate piece onto the access ladder.

Internal rail connectors, if appropriate, can also be used to connect the ladder elements together.

Inserting a ladder intermediate piece

The ladder intermediate pieces are used for connecting ladder segments - for a ladder repair or in the flange transition area of a wind turbine generator -to each other.

i

NOTICE!Specifications for the flange transition

• When installing a ladder intermediate piece in the flange transition area of a wind turbine generator, a deviation in rung spacing of ± 15 mm is allowed.

Ladder connectors

Page 38: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

38 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Assembly situation: Repair of a climbing route section

Preparation of the ladder intermediate piece for repair of an access ladder in the area of the climbing route.

A damaged section of the access ladder is replaced by a ladder intermediate piece.

1. Measure the damaged ladder section and saw it out with the cuts as close as possible to the mid-point between the ladder rungs. Perform the saw cut at a 90° angle to the ladder rail and afterwards deburr the cut surfaces.

2. With the aid of the rail section external connector or external rail connector, mount the ladder intermediate piece onto the access ladder.

Internal rail connectors, if appropriate, can also be used to connect the ladder elements together.

NOTICE!Specifications for the ladder intermediate piece

• When installing a ladder intermediate piece in a wind turbine generator, a deviation in rung spacing of ±15 mm is permitted. Hailo Wind Systems recommends a maximum deviation of the rung spacing of ±2 mm.

• The length of the ladder intermediate piece is variable, but comprises at least two rung lengths.Please observe the maximum deviation between rails. This differs when using internal or external rail connectors.

• When using a ladder-guided service lift, a maximum deviation between the rail ends of 2 mm must be observed during the assembly.

7. Assembly

Page 39: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

39Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Rung repair kit

Rung repair kit

Material of insertion tube: aluminium, Screw: galvanised steel.

Use in the case of a repair.

1. Insert the insertion tube into the ladder rung.

2. Insert a washer on other ladder rails and screw on.

7.5 Rung repair kit

Assembly aid for rung repair kit

Material:

Use in the case of a repair where rungs are deformed.

1. Screw the assembly aid onto the insertion tube. Fasten insertion tube on opposite side with screw.

2. Drive the insertion tube through the damaged rung with the assembly aid.

3. Unscrew the assembly aid.

Page 40: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

40 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Base anchor with rail clamp

Material: stainless steel or galvanised steel.

Can be used in 60 x 20 rail profiles.

1. Place the rail clamp around the ladder rail and screw to the screw tab. Do this for both ladder rails.

2. Set the tab with the elongated hole on the floor and screw to the tab with the rail clamp.

3. Screw the tab with the elongated hole to the ground.

Base anchor on the ladder rung

Material: stainless steel or galvanised steel.

For use with ladder-guided service lifts.

1. Place the rung adapter around the ladder rung and screw together on the tab with the elongated hole with the U-bolt.

2. Screw the tab with the elongated hole to the ground.

7.6 Base anchor

7. Assembly

Page 41: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

41Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Rest platforms

NOTICE!Specifications for rest platforms

• In wind turbine generators, a rest platform must be installed every 9 m along the entire ladder length in accordance with DIN EN 50308.

• According to DIN EN ISO 14122-4: 2016, a rest platform must be installed every 12 m along the entire ladder length.

7.7 Rest platforms

Rest platform on access ladders without fall protection rail

2. Screw the treading surface to the retaining rail of the rest platform.

Tighten the M10 hexagon nut only so tight that the rest platformcan still be easily pivoted.

1 a. Mount the retaining rail centred on the rungs with two U-bolts.

1 b. Mount the retaining rail centred on the rungs with two U-bolts. In doing this, screw the spacer sleeves tight between the fall protection rail and retaining rail. The rung is encircled by the U-bolt.

Rest platform on access ladders with a fall protection rail with drilled holes

a b

Page 42: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

42 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

This version of the rest platform can be used for various types of fall protection rails. You can obtain more information at [email protected]

Rest platform on access ladders with a fall protection rail without drilled holes

1. Lay the mounting block with thread in the groove of the fall protection rail. Screw the screws through the spacer sleeves in the mounting block.

2. Screw the treading surface to the retaining rail of the rest platform.

Tighten the M10 hexagon nut only so tight that the rest platformcan still be easily pivoted.

1. Place the retaining rail over the two rungs and fix in place with the three screws.

2. Screw the treading surface to the retaining rail of the rest platform.

Tighten the M10 hexagon nut only so tight that the rest platformcan still be easily pivoted.

7. Assembly

Both types of resting platforms are assembled according to the same principle as shown. However, the fastening components are not interchangeable with each other.

i

Page 43: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

43Assembly and operating instructions • Fixed access ladders, aluminium 60x20

1. Screw the wall bracket to the screw tab. When doing so, ensure that the shackles of the wall bracket are pointed outward.

2. Place the rung adapter around the ladder rung and fix it to the wall bracket with the U-bolt. Pay attention to the correct torque while doing so.

Equipotential bonding using special conductive rung adapters

7.8 Equipotential bonding

Equipotential bonding

Page 44: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

44 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Equipotential bonding via potential equalising rail

Material of potential equalizing rail: aluminium, Material of screw: galvanised steel.

1. Drill two holes (Ø 6.5 mm) into the ladder rails to be connected. When doing this, maintain a distance of 30 mm to each of the ladder ends.

2. Make sure that the ladder rails are connected to each other using internal rail connectors.

3. Bolt on the potential equalising rail with the provided screws.

4. The ladder must be connected with the potential equalising rails over its entire length.

5. Finally, the ladder must be earthed at both ends on the supporting structure.

NOTICE!Avoid ladder compression

• Only insert connecting tabs together with internal rail connectors, since otherwise the ladder can be compressed.

Page 45: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

45Assembly and operating instructions • Fixed access ladders, aluminium 60x20

• Before use of the access ladder system, the instructions must be read carefully and heeded.

• Especially observe the safety instructions in the chapter “Safety”.• The operating company must ensure that these assembly and operating instructions

are stored with each access ladder system on-site and are available to the user.

DANGER!Risk of injury due to failure to heed the safety instructions

Fall protection • Users are personally responsible for their own safety.

• The Personal Fall Protection Equipment (PFPE) must be checked every working day to ensure that it is in perfect and safe condition.

• Before and during use, the fall arrest system must be checked for any damage.

Use of fold-up rest platforms

• When using ladder-guided service lifts, make sure that the rest platforms are folded back in after use. Otherwise there is the danger of collision!

• Check that the rest platforms can be folded easily.

8. Usage

8.1 Safety instructions

Permissible number of persons on the ladder

• The number of persons who are allowed to climb on the ladder at the same time may not exceed 10 persons. A minimum distance of 6 m should be maintained between the persons climbing the ladder system.The minimum distance between the persons may be disregarded in case of emergency or rescue.

• In addition, the instructions provided by the manufacturer of the fall arrest system must be observed, since the permissible number of persons could be lower.

Page 46: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

46 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Securing against unauthorised entry

• The climbing equipment is to be secured against entry of unauthorised persons.

Safety of the user

DANGER!Danger of falling!

Disregarding the safety instructions may lead to a fall and thus cause serious injury or death.

For this reason, observe the following:• Always use your entire PFPE.

• Persons may connect to or release from the fall arrest system only from a secured position.

• When transferring on or off, the person must always be secured to a suitable attachment point (see specifications of the WTG manufacturer). Connecting to the ladder rungs is prohibited!

• Exiting the fall arrest system may only be done once the user is secured to a suitable attachment point.

• When getting on or off, the user must be able to grasp the climbing equipment firmly with both hands. This means that the user may not be holding any heavy loads.

• During the entry/exit, the user should neither touch nor activate the accompanying arrest device. This could impair or prevent the functioning of the brakes.

9. Inspection and maintenance

Page 47: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

47Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Safety instructions

Daily inspection

Yearly inspection • At least once a year, the access ladder system must be checked for proper condition and functionality. This must be done by a knowledgeable and qualified person.

• The check list for the yearly inspection of the access ladder system can be found in the appendix to these instructions.

• The respective national regulations for operation and testing must be complied with.

DANGER!Danger of falling!

A damaged or poorly maintained system can lead to a fall, resulting in serious injury or death.

For this reason, observe the following:• A regular inspection of the access ladder system

is imperative.• Before and during use, the fall arrest system must be

checked for any damage.• The system or components of the system are to be

withdrawn from use immediately if there are doubts about their safe condition.

• This must occur through the manufacturer or through another competent person.

• In the event of a fall, the system must be inspected immediately by a knowledgeable and qualified person.

Page 48: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

48 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

NOTICE!Adherence to all scheduled inspections and maintenance

• It is the responsibility of the operating company to ensure that inspection and maintenance is carried out according to schedule.

• Proof of regular inspection is required for assertion of any warranty claims.

Maintenance and repairs

• All non-moving parts are maintenance-free.

• Rest platforms are easy to lubricate and check for ease of movement as required.

• Damaged surfaces are to be sealed with a suitable corrosion protection agent.

• Contaminants should be cleaned with a gentle cleaning agent.

• No acids or alkalis may be used.

Page 49: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

49Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Assembly log of fixed access ladders DIN EN ISO 14122-4 / DIN EN 50308

General information

Date of installation

Location

WTG no.

Material

Aluminium □

Plastic □

Galvanised steel □

Stainless steel □

Type of ladder Length in meters

Ladder with fall arrest system according to DIN EN 353-1: 2018

Ladder without fall arrest system according to DIN EN 353-1: 2018

Ladder with rear protection

Ladder start OK Not OK Comment

Correct entry dimension □ □ DIN EN ISO 14122-4: 100-400 mm

Wall bracket OK Not OK Comment

Attachment to tower wall (dimension)

□ □ at least M12

Secure fit of screw connections (torque)

Nm See manual or design drawing of WTG manufacturer

Threadlock usedYES□

NO □

Distance to wall □ □DIN EN ISO 14122-4: at least 200 mm distance from rung front edge to wall behind the ladder

Distance to the tower flange □ □DIN EN ISO 14122-4 At least 150 mm distance from rung front edge to wall

10. Assembly log

Page 50: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

50 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Wall brackets OK Not OK Comment

Vertical distance2 m □

> 2 m□

Manufacturer approval obtained

YES□

NO □

Correct installation according to specifications

□ □

Ladder fastenings OK Not OK Comment

Correct installation□ □

According to manufacturer specifications (see installation instructions or design drawing of WTG manufacturer)

Secure fit of screw connections (torque)

NmAccording to manufacturer specifications (see installation instructions or design drawing of WTG manufacturer)

Rungs OK Not OK Comment

Rung spacing 280 ± 2 mm; ± 15mm (flange)

□ □For ladder impacts / exchange pieces

Ladder connectors OK Not OK Comment

Section rail connector YES□

NO□

Rail misalignment □ □ max. 1 mm

Tight fit of screw connection □ □

Air gap rail ends (max. 2 mm) □ □

External rail connectorYES□

NO□

Tight fit of screw connection □ □

Air gap rail ends(max. 30 mm)

□ □

Internal rail connectorYES□

NO□

Screw connection (only required for lattice tower)

□ □

Air gap rail ends(max. 30 mm and max. 2 mm for ladder-guided lifts)

□ □

Page 51: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

51Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Labelling OK Not OK Comment

Nameplate attached □ □

Inspection sticker attached / Installation date entered

□ □

Rest platforms OK Not OK Comment

Correct installation according to specifications

□ □

According to manufacturer specifications (see installation instructions or design drawing of WTG manufacturer)

Secure fit of screw connections (torque)

NmAccording to manufacturer specifications (see installation instructions or design drawing of WTG manufacturer)

Distance between the platforms m

According to manufacturer specifications (see installation instructions or design drawing of WTG manufacturer)

Condition of the climbing path YES NO Comment

Initial assembly □ □

Repair □ □

Usability □ □

Next inspection Month Year

Company performing services

Name of assembler (please print)

Certificate number

Signature

Page 52: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

52 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Recurrent inspection of fixed access ladders DIN EN/ISO 14122-4 / DIN EN 50308

General information

Date of the inspection

Location

WTG no.

Material

Aluminium □

Plastic □

Galvanised steel □

Stainless steel □

Type of ladder Length in meters

Ladder with fall arrest system according to DIN EN 353-1: 2018

Ladder without fall arrest system according to DIN EN 353-1: 2018

Ladder with rear protection

Labelling OK Not OK Comment

Present and legible □ □

Wall brackets OK Not OK Comment

Secure fit of screw connections □ □

Deformation / damage □ □

Corrosion □ □

Ladder fastenings OK Not OK Comment

Correct installation □ □ According to manufacturer’s specifications

Corrosion □ □

Secure fit of screw connections □ □

Condition of fastening □ □

11. Log for inspection

Type of inspection

Recurrent inspection □

Non-scheduled inspection □

Page 53: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

53Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Rungs OK Not OK Comment

Check rung fit (wiggle, shake, twist)

□ □According to manufacturer’s specifications

Rung bulge (outside rail)

□ □For use of service lifts on ladder

Deformation < 1.5 mm□

> 1.5 mm□

Non-slip surface □ □

Corrosion □ □

Cracks / ridges □ □

Rung spacing 280 ± 2 mm; ± 15mm (flange)

□ □For ladder impacts / exchange pieces

Secure fit of screw connections (repair kit)

□ □If rung is attached with repair kit

Rail OK Not OK Comment

Deformation < 1.5 mm□

> 1.5 mm□

Cracks □ □

Ridges □ □

Corrosion □ □

Ladder connectors OK Not OK Comment

Section rail connector YES□

NO□

Rail misalignment □ □ max. 1 mm

Tight fit of screw connection □ □

Air gap rail ends (max. 2 mm) □ □

External rail connectorYES□

NO□

Tight fit of screw connection □ □

Air gap rail ends(max. 30 mm)

□ □

Page 54: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

54 Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Ladder joints OK Not OK Comment

Internal rail connectorYES□

NO □

Screw joint (required for pylon) □ □

Air gap of rail ends (max. 30 mm)

□ □

Rest platforms OK Not OK Comment

Fastener □ □

Function □ □

Corrosion □ □

Damage □ □

Result of inspection OK Not OK Comment

Condition of the ladder □ □

Usability □ □

Repair / replacementYES□

NO□

DisabledYES□

NO□

Further testing necessaryYES□

NO□

Next inspection Month Year

Company performing services

Name of inspector (please print)

Certificate number

Signature

Page 55: FIXED ACCESS LADDERS, ALUMINIUM 60 x20...HIGH LEVEL ACCESS SOLUTIONS English Art. no. 1121569 FIXED ACCESS LADDERS, ALUMINIUM 60 x20 IN WIND TURBINE GENERATORS AND MACHINE INSTALLATIONS

Assembly and operating instructions • Fixed access ladders, aluminium 60x20

Remarks