Fives

14
Fives Pillard 1 Fives Driving Progress ANALYSERS & INSTRUMENTS DEPT. TUNNEL ROAD APPLICATION I - GAS DETECTORS I I - OPACIMETERS III - ANEMOMETERS

description

ANALYSERS & INSTRUMENTS DEPT. TUNNEL ROAD APPLICATION I-GAS DETECTORS I I-OPACIMETERS III-ANEMOMETERS. Driving Progress. Fives. VIEW OF OUR SCOPE OF SUPPLY IN TUNNEL. Anemometers. Burner. Ignitor's tube. Opacimeters/ Dust monitors. Gas detector. Smoke detector. - PowerPoint PPT Presentation

Transcript of Fives

Page 1: Fives

Fives Pillard 1

Fives Driving Progress

ANALYSERS & INSTRUMENTS DEPT.

TUNNEL ROAD APPLICATION

I - GAS DETECTORSI I - OPACIMETERS

III - ANEMOMETERS

Page 2: Fives

Fives Pillard 2

VIEW OF OUR SCOPE OF SUPPLY IN TUNNEL

Ignitor's tube

Burner

Gas detector

Anemometers

Opacimeters/Dust monitors

Smoke detector

Page 3: Fives

Fives Pillard 3

Fives Driving Progress

TUNNEL DEPARTMENT

I- GAS DETECTOR

NOCOSTOP V2

Page 4: Fives

I- NOCOSTOP VIEW OF THE PRODUCT

4

Page 5: Fives

Fives Pillard 5

OPERATING PRINCIPLE

NOCOSTOP V2 NOCOSTOP V2

Type

TechnologyElectrochemical Cell Electrochemical Cell

Type of measure

Continuously

In situ

Continuously

In sampling

Type of Gas measuredNO / CO / NO2

1 cell by gasNO / CO / NO2

1 cell by gas

Material ABS ABS

In samplingIn situ

Page 6: Fives

TECHNICAL SPECIFICATIONS

OPASTOP

6

NOCOSTOP V2

Mechanical characteristics

Mechanical characteristics ABS Material (Stainless steel in option)

Housing protection IP65

Dimensions / Weight 127 x 150 x 80 mm / 500 g

Anti-water splash device Integrated

Particle filter Integrated

Metrological characteristics

Measuring range CO: 0 –100 to 300 ppm ; NO : 0-10 to 100 ppm ; NO2 : 0-1 to 10 ppm

Resolution CO and NO : 0,1 ppm ; NO2 : 0,05 ppm

Accuracy CO : 2 ppm ; NO : 0,2 ppm ; NO2 : 0,1 ppm

Lower detection limit CO : 1 ppm ; NO : 0,5 ppm ; NO2 : 0,2 ppm

Response time < 30 s

Expected lifetime > 3 years

Drift < 5% per year

Temperature range - 40°C to +65°C

Page 7: Fives

ELECTRICAL CHARACTERISTICS

7

Electrical characteristics

Power supply24 VDC +10/-15%

Power consumption 0,7 W without heating / 12 W with heating

Interfacing Compatible with RC3 communication console Communication by 4/20 mA connection

Fault warning Signal between 1 and 3 mA

Page 8: Fives

WEIGHT, SIZE & DIMENSIONS

8

Weight = 500 g

Page 9: Fives

Electrical connection

9

Designation of the cable conductors Use

Positive pole 24VDetector power supply 24VDC

(0,450 A when operating with heater)Negative pole 24V

Positive pole of 4-20mA loopCurrent loop outlet

(Toxic gas concentration)Negative pole of 4-20mA loop

Earth Earth for electrical protection and CEM

Page 10: Fives

ACCESSORIES, OPTIONS, SERVICES

Display: LCD screen on front face

Extractive measure Adaptor for gas circulation

Maintenance LC3 console

Housing Stainless steel 304L

Calibration kit for maintenance

Services for testing, assistance with commissioning, annual, maintenance contract etc….

10

Page 11: Fives

Fives Pillard 11

VIEW OF FITTED PRODUCT

Page 12: Fives

ELECTRICAL OUTPUT

12

Ear

th

+ 2

4 V

DC

- 24

VD

C+

4-2

0 m

A4-

20 m

A

Page 13: Fives

PRODUCT MAINTENANCE

13

I- Calibration of the equipment

I) + +

II- Replacement of the filter

+ +

Page 14: Fives

MAIN ADVANTAGES

Easy start-up and maintenance

Simple calibration, without dismantling

One cabinet : possibility 3 cells thermo-regulated (1 per cabinet) Adjustable scale 0 à 300ppm of CO 0 à 100 ppm of NO 0 à 10 ppm of NO2

Protection IP65 Two possible configurations In-situ or extractive measuring

In situ version

Extractive version

Remote control

Calibration gas