Five Techniques for Better LabVIEW Code Peter Blume President [email protected].
-
Upload
nyah-fanning -
Category
Documents
-
view
217 -
download
5
Transcript of Five Techniques for Better LabVIEW Code Peter Blume President [email protected].
www.bloomy.com© 2003 Bloomy Controls Inc.
Overview
Introduction Five techniques with examples
Specifications Data flow State machines Error handling Documentation
Conclusion
www.bloomy.com© 2003 Bloomy Controls Inc.
Introduction
Most LabVIEW applications begin with an industrial measurement and/or control challenge
LabVIEW facilitates fast development cycles Easy to connect and control instrumentation Fast solutions to industrial challenges Instant gratification for developers
LabVIEW developers adopt fast habits Sloppy wiring No documentation Computer science fundamentals are ignored
Fast habits = bad habits
www.bloomy.com© 2003 Bloomy Controls Inc.
Justifying Bad Habits
LabVIEW is a graphical language Computer science fundamentals don’t apply Block diagram is self-documenting
We don’t have time to write good code Intense time pressures LabVIEW is a secondary responsibility Requirements continuously change Equipment availability constraints
I’m the only developer / end-user Nobody else needs to use or understand my programs
www.bloomy.com© 2003 Bloomy Controls Inc.
Issues Resulting from Bad Habits
Application requirements expand LabVIEW code becomes messy
Inefficient Buggy Difficult to troubleshoot, expand, and maintain Not reusable
Overall development time is increased
www.bloomy.com© 2003 Bloomy Controls Inc.
Bad Code Example
www.bloomy.com© 2003 Bloomy Controls Inc.
Good Code Example
www.bloomy.com© 2003 Bloomy Controls Inc.
Let’s Write Better LabVIEW Code!
Follow these five techniques More up-front time and effort Attention to detail Discipline
Dramatically save time in the long run
www.bloomy.com© 2003 Bloomy Controls Inc.
1. Write a Functional Specification
Understand the application’s requirements Interview operators, developers, engineers, managers,
bean counters Document the requirements
Statement of high-level objectives Specific requirements for I/O, analysis, GUI Timetable and budget Design prototype screen shot Assign priorities to each requirement Test methodology
www.bloomy.com© 2003 Bloomy Controls Inc.
Functional Specification (Continued)
Avoid designing the system Don’t prolong specification phase by including too much
detail such as how to implement the systemMake the specification readily accessible
Have all contributors review and approve Revise when requirements change Keep it somewhere that you and others can quickly
reference it
www.bloomy.com© 2003 Bloomy Controls Inc.
Simple Specification Example
www.bloomy.com© 2003 Bloomy Controls Inc.
Bad Code Example
www.bloomy.com© 2003 Bloomy Controls Inc.
Good Code Example
www.bloomy.com© 2003 Bloomy Controls Inc.
2. Use Proper Data Flow
Data flow definition:“A block diagram node executes when all its inputs are available.
When a node completes execution, it supplies data to its output terminals and passes the data to the next node in the dataflow path.”
Parallel paths are permitted and desirable Efficiency is optimized when LabVIEW determines the
execution order Readability is optimized when source terminals, wires,
and destination terminals are visible
www.bloomy.com© 2003 Bloomy Controls Inc.
Data Flow Impediments
Sequence structures Excessive nesting Local and global variables Coercions Sloppy wiring
Excessive bends Overlapping wires with other objects Multidirectional data flow
www.bloomy.com© 2003 Bloomy Controls Inc.
Simple Data Flow Example
Impeded Unnecessary
sequence Coercion Local variables
Better data flow
www.bloomy.com© 2003 Bloomy Controls Inc.
Bad Code Example
www.bloomy.com© 2003 Bloomy Controls Inc.
Bad Code – Zoom In on Wiring
www.bloomy.com© 2003 Bloomy Controls Inc.
Data Flow Enhancements
Artificial data dependency Use error cluster and/or task ID
Shift registers Reduce local and global variables
Clusters Reduce the overall number of wires
Neat wiring Left-to-right data flow Straight wires Consistent data types Comments with “>” indicating data flow direction
www.bloomy.com© 2003 Bloomy Controls Inc.
Good Code Example
www.bloomy.com© 2003 Bloomy Controls Inc.
3. Use a State Machine Top-Level Architecture
Define application as a series of states Go to any state from any other state Easy to modify, maintain, and debug Self-documenting Scalable
www.bloomy.com© 2003 Bloomy Controls Inc.
Classic State Machine
www.bloomy.com© 2003 Bloomy Controls Inc.
State Machine Enhancements
Use enumerated or string for case selector
Poll user interface events in “No Event, Default” frame or in separate event structure in parallel loop
Use intuitive state names Include “Initialize” and “Shutdown” states
www.bloomy.com© 2003 Bloomy Controls Inc.
Enumerated State Machine
www.bloomy.com© 2003 Bloomy Controls Inc.
Event-Driven State Machine
www.bloomy.com© 2003 Bloomy Controls Inc.
4. Incorporate Proper Error Handling
Trap and report any I/O related errors in all VIs I/O functions include DAQ, file I/O, instrument I/O,
communication Trapping is facilitated by propagation of error cluster Reporting methods include dialog prompt or log to file
www.bloomy.com© 2003 Bloomy Controls Inc.
Error Trapping
www.bloomy.com© 2003 Bloomy Controls Inc.
What’s Wrong With This Picture?
www.bloomy.com© 2003 Bloomy Controls Inc.
Better Error Handling
www.bloomy.com© 2003 Bloomy Controls Inc.
5. Document Your Source Code
Assume every VI will be used and maintained by other developers
Best time to document your source code is while you develop it
www.bloomy.com© 2003 Bloomy Controls Inc.
LabVIEW Documentation Techniques
Control labels Use succinct, intuitive labels Indicate units in parentheses or use free labels Enter descriptions or online help where further text is needed
Icons Intuitive text or graphic 10-point small fonts Color-coding for icons of related subVIs
www.bloomy.com© 2003 Bloomy Controls Inc.
Documentation Techniques (cont’d)
Diagram Leave the background color white Set all control labels visible Liberally document with free labels
Enter descriptions for every subVI
www.bloomy.com© 2003 Bloomy Controls Inc.
Bad Code Example
www.bloomy.com© 2003 Bloomy Controls Inc.
Good Code Example
www.bloomy.com© 2003 Bloomy Controls Inc.
Summary
Write a specification for all projects before you begin coding
Use proper data flow Use a state machine top-level architecture Incorporate proper error handling Document your source code while you code
www.bloomy.com© 2003 Bloomy Controls Inc.
Conclusion
Techniques improve: Readability Robustness Efficiency Maintainability Reusability
Techniques can be implemented quickly if you make them habits Apply to every project, starting now Apply consistently throughout each project
Dramatic reduction in overall time and effort
www.bloomy.com© 2003 Bloomy Controls Inc.
About Bloomy Controls
Test, measurement, automation, and control specialists since 1991
Systems integration, software development, and training provider
NI Select Integrator and Certified Training Center 3 Certified LabVIEW Architects 8 Certified LabVIEW Developers 1 Certified TestStand Architect 2 Certified TestStand Developers 8 Certified Professional Instructors
Offices in Windsor, CT; Milford, MA; and Mahwah, NJ