Fire/Electrical Safety Community-Wide Student Orientation.
-
Upload
lorena-lucas -
Category
Documents
-
view
218 -
download
4
Transcript of Fire/Electrical Safety Community-Wide Student Orientation.
Fire/Electrical Safety Fire/Electrical Safety Community-Wide Community-Wide
Student OrientationStudent Orientation
2
Chemistry of FireChemistry of Fire
Fire burns because there Fire burns because there are three elements are three elements present...present... Fuel Heat Oxygen
By removing any one element a fire can not occur, or a fire will not be able to sustain combustion.
3
Fire Prevention Fire Prevention Practices...Practices...
Keep passage ways and exits clear Ensure fire extinguishers and fire
alarm pull stations are accessible at all times
Place trash in proper receptacles Ensure that fire doors are not
blocked open
4
Plan for Fire Plan for Fire Emergencies..Emergencies....
Read & understand the fire evacuation plan for your area
Know the location of at least two (2) emergency exits
Know the location of fire alarm pull stations and fire extinguishers
Take part in fire drills
5
Plan for Fire Plan for Fire Emergencies..Emergencies....
Have you ever stayed at a hotel and taken the time to look at the evacuation plan posted on the inside of the room door?
Think about the following, you’re awakened at 3am from a sound sleep to hear this loud whistling sound or horn blaring. As you begin to wake up you smell smoke and suddenly you are no longer sleepy.
6
Plan for Fire Plan for Fire Emergencies..Emergencies.... You run to the door, feel it for heat and open
it. The hallway is full of thick black smoke, and it invades your room and your lungs, choking you. You fall to the floor and start to crawl forward looking for the exit signs. Only you can not see them and you do not know where the stairs are. And you think to your self ....... your alarm rings and you wake up, it was only a dream. But it could happen. Always be prepared, know your role in the event of a facility fire and take an active part.
7
In Case of Fire...In Case of Fire...
Remain calm. Don’t panic or cause confusion. NEVER shout fire.
Proceed safely to nearest fire exit Feel surfaces of doors before opening Crawl to exit if smoke is present in
area Follow instructions of Fire Department Remember R.A.C.E. and P.A.S.S.
8
R.A.C.E. for R.A.C.E. for Fire Safety...Fire Safety...
Rescue anyone in immediate danger.
Activate the fire alarm pull station Contain the fire Extinguish the fire, if your safety
can be assured
9
P.A.S.S. for Fire P.A.S.S. for Fire Extinguisher Use...Extinguisher Use...
Pull the pin Aim at base of the fire Squeeze the handles together Sweep from side to side
10
Classes of FireClasses of Fire
The most common fire extinguisher used in healthcare is multiclass, or what is termed
an ABC class extinguisher.
Ordinary Ordinary
CombustiblesCombustibles Flammable Flammable
LiquidsLiquids Involving Involving
ElectricityElectricity Combustible Combustible
MetalsMetals
11
Fire Drills...Fire Drills... Conducted every quarter on every shift
in Hospital Respond immediately as if actual fire.
Remember R.A.C.E. and P.A.S.S. All corridor fire doors are connected to
fire alarm & detection system and will close automatically once activated
12
Fire Drills...Fire Drills...
Fire doors are designed to withstand fire, heat and smoke for a period of 20-minutes to 3 hours.
Did you know that corridor doors are fire doors and should have a 20 minute rating?
Corridor laboratory doors should have a 60 minute rating.
Fire Doors are required to: Be Self Closing: fire doors should
have a door closure that pulls doors completely shut after the door has been opened
Have Positive latching: a positive latch locks a door in place so can open swing open freely.
13
No No Smoking Smoking Policy...Policy...
Smoking by anyone, which includes patients, visitors, medical staff, associates, and visitors is prohibited inside the buildings.
14
Electrical Safety Electrical Safety BriefingBriefing
15
What is Electricity?What is Electricity? A medium that provides a very
convenient means for transferring energy from one place to another
Correctly used, electricity is our most versatile form of energy
Control of most electrical hazards is neither difficult or expensive, but ignoring them can cause serious consequences
16
CharacteristicCharacteristics of s of Electricity...Electricity...
Electricity has most of the characteristics of water, in that it flows and has a current that can be measured
17
Electrical Faults Result Electrical Faults Result in Shock, Burns or in Shock, Burns or Fire...Fire...
Flow of CurrentFlow of Current Occurs when a person
or conducting object bridges gap between live conductors and ground or between live conductors. This action causes current to flow.
18
Electrical Faults Electrical Faults Result in Shock, Result in Shock, Burns or Fire...Burns or Fire...
This is the reasoning behind birds on high voltage wires and why they do not fry. Since the bird is only on the wire there is no conduction between ground or other live conductors. However, if I go to trim my trees and touch the wires or place my ladder on the wires, I have bridged the gap between the live conductor and the ground. Current flows from the line through my body and gets discharged into the ground. That is a big OUCH!
19
Electrical Faults Electrical Faults Result In Shock, Result In Shock, Burns or Fire...Burns or Fire...
Static ElectricityStatic Electricity Occurs when static
electrical charges accumulate from friction between dissimilar materials. Discharge of static electricity causes a mild shock.
20
Causes Of Causes Of Electric Shock...Electric Shock...
Current flow is the factor that causes injury in electric shock; body resistance will determine the path of flow
Once the skin is broken, a victim will have sharply reduced internal resistance to the flow of current
21
Low Voltage Lethal Low Voltage Lethal Shock Computations...Shock Computations...
Circuits of 110 volts or less can kill when the conditions are right. This is regular household current.
Synchronized cardioversion 100mA
22
Overcurrent Devices...Overcurrent Devices...
Protect circuit from excessive heating by opening the circuit automatically in event of excessive current flow from accidental ground, short circuit, or overload.
Examples include fuses and circuit breakers.
23
Ground Fault Circuit Ground Fault Circuit Interrupter...Interrupter...
GFCI is a fast-acting circuit breaker that is sensitive to very low levels of current leakage (5mA) to ground. When leakage becomes hazardous, it interrupts circuit.
24
Ground Fault Circuit Ground Fault Circuit Interrupter...Interrupter...
You can find GFCIs in what electricians call “wet” areas such as the bathroom and kitchen. GFCIs are normally used for outside wiring outlets also.
25
Electrical Electrical SafetySafetyPolicy...Policy...
An equipment management plan exists to identify, evaluate, inventory, and maintain medical equipment to reduce the physical and health risks associated with its usage
All biomedical and electrical equipment used in a Hospital must be inspected and tested prior to use and labeled with a safety sticker
26
Electrical Electrical SafetySafetyPolicy...Policy...
All electrical devices a patient may bring into the hospital need to be inspected and tested prior to use and labeled with a safety sticker prior to their use.
27
Electrical Electrical SafetySafety Rules... Rules... Visually inspect all equipment for damage
prior to use Do not use extension cords for permanent
wiring Unplug equipment by pulling on the plug
and not the cord Damaged or defective
biomedical/electrical equipment must be removed from service and reported to appropriate authority for repair
28
Electrical Electrical SafetySafety Rules... Rules... Keep fluids, chemicals, and heat away
from equipment, cords, and cables Maintain sufficient access around
equipment & panels for operations/maintenance
Do not touch energized/conductive surfaces with one hand while touching the patient with the other
Know the function of each control prior to using equipment
29
Emergency Emergency PowerPower
Hospitals are equipped with emergency generators which will start automatically if there is a loss of electrical power
Emergency generators are tested monthly in Hospitals
Red electrical outlets provide emergency power for critical patient care equipment
30
Just to recap,fire requires three elements. Heat source, fuel and oxygen. When one is absent, there can be no fire.
It is important to take an active part in fire drills so that you are aware of what your role is in the event of a fire.
Remember R.A.C.E. and P.A.S.S.
Points to RememberPoints to Remember
31
Electricity is a convenient source of energy but should not be taken for granted.
It has a current that can be measured and if not respected can kill.
The human body has the ability to conduct electricity and serves as the conducting object when an individual touches a live circuit.
Points to RememberPoints to Remember
32
All patient electrical devices must be checked and cleared by biomed prior to use in the facility, they will have a tag attached when this has been completed.
Most of electrical safety, and for that matter fire safety, involves common sense and an ability to keep your eyes open for hazards in the work place.
Points to RememberPoints to Remember