Fire Seal Full Presentation

108
A DIVISION WITHIN

description

Protección Pasiva contra Incendios en al Industria Naval

Transcript of Fire Seal Full Presentation

Page 1: Fire Seal Full Presentation

A DIVISION WITHIN

Page 2: Fire Seal Full Presentation

FireSeal - founded some 30 years ago with head office close toStockholm, Sweden.

Initially a supplier to nuclear power plants – since 20 year´s ourcore business is the marine & offshore market.

Fireseal a business unit within the mother company Essve with anannual turnover of € 60 million and 135 employees.

Essve owned by B & B Tools, a public company with an annualturnover of € 617 million (US$ 831 million).

COMPANY OVERVIEW

Page 3: Fire Seal Full Presentation

WORLDWIDE PRESENCE

North AmericaSouth America

AustriaCroatiaDenmarkDubaiFinlandIcelandItalySwedenNorwayPolandRussiaTurkeyU.K

AustraliaChinaHong KongRussiaMalaysiaSouth KoreaSingaporeVietnam

Page 4: Fire Seal Full Presentation

TESTING & APPROVALSFireSeal´s systems are designedin accordance with the SOLAS(Safety Of Life At Sea) regulationand IMO resolution (InternationalMaritime Organization).

All FireSeal´s systems areapproved for A0 - A60 or H0 - H60classification and resistance to;

- Fire- Water- Pressure- Smoke- Gas- Vibrations & Movements

Page 5: Fire Seal Full Presentation

US Coast Guard

Det Norske Veritas

Bureu Veritas

MED Germanischer Lloyd

ABS

Rhina

Korean Register

FireSeal´s systems has undergone testing under the harshest conditionspossibly and is certified by major authorities and classification societiessuch as;

Lloyd´s Register

TESTING & APPROVALS

Page 6: Fire Seal Full Presentation

One of the fastest and easiest system on themarket for cable, pipe and ductwork penetrations!

FLEX-D SYSTEM

Page 7: Fire Seal Full Presentation

FLEX-D SYSTEM

Smoke, gas, water and pressureresistance.

Average 20 min. installation time.

Movements and vibration of pipesand cables are accepted.

Two part numbers independently of;

a) pipe or cable penetration.b) sizes of cables.c) penetration size opening.

1. Firestop Sealant 3000 (Silicone Sealant)2. Blanket D-24B (Non-combustible calcium silicate fibre)

Page 8: Fire Seal Full Presentation

Watertight up to 2,5 kg (25 m or 2,5bar).

A0 - A60 and H0 - H60.

Cable penetration < 800 x 400 mm.

Pipe penetration < 534 x 274 mm

Uninsulated steel pipe < 48,3 mm.

Insulated steel pipe < 273 mm.

FLEX-D SYSTEM

Page 9: Fire Seal Full Presentation

FLEX-D PIPE INSTALLATION

Page 10: Fire Seal Full Presentation

FLEX-D PIPE INSTALLATIONA0 - A60 SLEEVE LENGTH 200 MM (H0 - H60 250 MM)

Page 11: Fire Seal Full Presentation

BLANKET D-24BFIRESTOP SEALANT 3000HANDTOOL & KNIFE

WHAT YOU NEED

Page 12: Fire Seal Full Presentation

REMOVE ANY LOOSE DEBRIS

Page 13: Fire Seal Full Presentation

CUT BLANKET D-24B, 100 MM WIDTH

Page 14: Fire Seal Full Presentation

ROLL THE BLANKET TO SUITABLE SIZE

Page 15: Fire Seal Full Presentation

ROLL THE BLANKET TO SUITABLE SIZE

Page 16: Fire Seal Full Presentation

PACK CAVITY WITH BLANKET

Page 17: Fire Seal Full Presentation

PACK CAVITY WITH BLANKET

Page 18: Fire Seal Full Presentation

PACK CAVITY WITH BLANKET

Page 19: Fire Seal Full Presentation

PACK CAVITY WITH BLANKET

Page 20: Fire Seal Full Presentation

PACK CAVITY WITH BLANKET

Page 21: Fire Seal Full Presentation

APPLY FIRESTOP SEALANT 3000

Page 22: Fire Seal Full Presentation

APPLY FIRESTOP SEALANT 3000

Page 23: Fire Seal Full Presentation

APPLY FIRESTOP SEALANT 3000

Page 24: Fire Seal Full Presentation

FINISHED SEAL ON ONE SIDE!

Page 25: Fire Seal Full Presentation

NOW THE OTHER SIDE OF THE SEAL

Page 26: Fire Seal Full Presentation

ROLL THE BLANKET

Page 27: Fire Seal Full Presentation

PACK CAVITY WITH BLANKET

Page 28: Fire Seal Full Presentation

APPLY FIRESTOP SEALANT 3000

Page 29: Fire Seal Full Presentation

TOTAL INSTALLATION TIME 10 - 15 MINUTES!

Page 30: Fire Seal Full Presentation

FLEX-D CABLE INSTALLATION(NEW PENETRATION)

Page 31: Fire Seal Full Presentation

FLEX-D CABLE INSTALLATION

Page 32: Fire Seal Full Presentation

WHAT YOU NEEDBLANKET D-24BFIRESTOP SEALANT 3000HANDTOOL & KNIFE

Page 33: Fire Seal Full Presentation

REMOVE LOOSE DEBRISE

Page 34: Fire Seal Full Presentation

CUT BLANKET 100 MM WIDE STRIP

Page 35: Fire Seal Full Presentation

ROLL THE BLANKET TO SUITABLE SIZE

Page 36: Fire Seal Full Presentation

PACK CAVITY WITH BLANKET

Page 37: Fire Seal Full Presentation

PACK CAVITY WITH BLANKET

Page 38: Fire Seal Full Presentation

PACK CAVITY WITH BLANKET

Page 39: Fire Seal Full Presentation

PACK CAVITY PROPERLY WITH BLANKET

Page 40: Fire Seal Full Presentation

DISTANCE 15 MM (A0 - A60) 25 MM (H0 - H60)

Page 41: Fire Seal Full Presentation

THE CAVITY IS PROPERLY PACKED

Page 42: Fire Seal Full Presentation

APPLY FIRESTOP SEALANT 3000

Page 43: Fire Seal Full Presentation

APPLY FIRESTOP SEALANT 3000

Page 44: Fire Seal Full Presentation

APPLY FIRESTOP SEALANT 3000

Page 45: Fire Seal Full Presentation

APPLY FIRESTOP SEALANT 3000

Page 46: Fire Seal Full Presentation

APPLY FIRESTOP SEALANT 3000

Page 47: Fire Seal Full Presentation

EVEN OUT THE FIRESTOP SEALANT 3000

Page 48: Fire Seal Full Presentation

EVEN OUT THE FIRESTOP SEALANT 3000

Page 49: Fire Seal Full Presentation

EVEN OUT THE FIRESTOP SEALANT 3000

Page 50: Fire Seal Full Presentation

ADD FIRESTOP SEALANT 3000 FORWATER TIGHTNESS IF NECCESARRY

Page 51: Fire Seal Full Presentation

NOW THE OTHER SIDE OF THE SEAL

Page 52: Fire Seal Full Presentation

FINISHED SEAL WITHIN 15 - 20 MINUTES!

Page 53: Fire Seal Full Presentation

FLEX-D CABLE INSTALLATION(ADDING A NEW CABLE)

Page 54: Fire Seal Full Presentation

CUT A HOLE WITH A KNIFE

Page 55: Fire Seal Full Presentation

PUSH THE CABLE THROUGH THE HOLE

Page 56: Fire Seal Full Presentation

ALTERNATIVE TOOL FOR ADDING CABLE

Page 57: Fire Seal Full Presentation

SEAL AROUND THE CABLE WITHFIRESTOP SEALANT 3000

Page 58: Fire Seal Full Presentation

EVEN OUT THE SEALANT

Page 59: Fire Seal Full Presentation

FIRESEAL FLEX-D BENEFITS

AVERAGE 20 MINUTES OPERATION.INSTALLATION

EASY, 5 MINUTES OPERATION.MODIFICATION

NO SPECIAL FRAMES REQUIRED.

TECHNICAL TRAINING

FLEX-D REQUIRES ONLY TWO PART NUMBERSINDEPENDANTLY OF APPLICATION AND PENETRATIONSIZE OPENING.

BUNDLED CABLES ACCEPTED.

20 - 30 MIN INSTALLATION TRAINING REQUIRED.

CABLE INSTALLATION

PART NUMBERS

FRAME INSTALLATION

* The FireSeal benefit overview is based upon using FireSeal Flex-D system which is the main FireSeal system usedfor all types of applications i.e. cables, pipes and ductwork.

WEIGHT LIGHT WEIGHT FIRE SEALING SYSTEM.

TOTAL COST VERY COMPETITIVE!

Page 60: Fire Seal Full Presentation

FS-03 SYSTEM1. Silicone foam D-03 comp. A and D-03 comp. B2. Blanket D-24B3. Silicone foam machine

2-component sealing system forcables, pipes and ductwork.

Suitable especially for larger andcomplicated penetrations.

Smoke, gas, water and pressureresistance.

Movements and vibration of pipesand cables accepted.

Installed by approved applicatorshaving access to special equipment.

Page 61: Fire Seal Full Presentation

0,5 bar resistance.

A0 - A60 and H0 - H60

Insulated steel pipe < 273 mm.

Uninsulated steel pipe < 60 mm.

Penetration opening < 600 x 400 mm.

FS-03 SYSTEM

Page 62: Fire Seal Full Presentation

FS-03 SYSTEM INSTALLATION

Page 63: Fire Seal Full Presentation

FIRESEAL FS-03 INSTALLATION

Page 64: Fire Seal Full Presentation

CUT BLANKET 25 MM WIDE STRIP

Page 65: Fire Seal Full Presentation

ROLL THE BLANKET TO SUITABLE SIZE

Page 66: Fire Seal Full Presentation

FILL THE CAVITY WITH THE BLANKET

Page 67: Fire Seal Full Presentation

FILL THE CAVITY WITH THE BLANKET

Page 68: Fire Seal Full Presentation

FILL THE CAVITY WITH THE BLANKET

Page 69: Fire Seal Full Presentation

PUT BLANKET D-24B BETWEEN CABLES

Page 70: Fire Seal Full Presentation

FILL CAVITY WITH FIRST LAYER OF FS-03

Page 71: Fire Seal Full Presentation

LEAVE FOR CURING ABOUT 3 MIN.

Page 72: Fire Seal Full Presentation

FILL CAVITY WITH SECONDAND A THIRD LAYER OF FS-03

Page 73: Fire Seal Full Presentation

LEAVE FOR CURING BETWEENTHE FILLING ABOUT 3 MIN.

Page 74: Fire Seal Full Presentation

FINAL RESULT USING FIRESEAL FS-03

Page 75: Fire Seal Full Presentation

PIPELOCK PL SYSTEM1. Pipelock PL (Phenolic plastic)2. FireStop Sealant 30003. Two steel sliding cleats

Complete, factory made seal forsingle plastic pipes.

Phenol plastic material i.e. 100 %corrosion resistant.

Available sizes: PL 55, PL 82,PL 110 and PL 160.

One of the fastest and easiestsystem on the market to install.

Page 76: Fire Seal Full Presentation

3 bar watertightness inconjunction with FireStop Sealant3000.

A0 - A60 approval.

Plastic pipe up to 160 mm in steelbulkhead / decks

Plastic pipe up to 110 mm inaluminium bulkhead / decks

PIPELOCK PL SYSTEM

Page 77: Fire Seal Full Presentation

PIPELOCKPLASTIC PIPE INSTALLATION

Page 78: Fire Seal Full Presentation

PIPELOCK PLASTIC PIPE INSTALLATION

Page 79: Fire Seal Full Presentation

PIPELOCK PARTS

Page 80: Fire Seal Full Presentation

PIPELOCK PARTS

Page 81: Fire Seal Full Presentation

PLACE THE PIPELOCKAROUND THE PLASTIC PIPE

Page 82: Fire Seal Full Presentation

PLACE THE PIPELOCKAROUND THE PLASTIC PIPE

To safeguard against the passage of smoke or gas, or to obtainwatertightness the joint beetween the pipe and the steel division should besealed with FireStop Sealant 3000.

Page 83: Fire Seal Full Presentation

PLACE THE PIPELOCKAROUND THE PLASTIC PIPE

Page 84: Fire Seal Full Presentation

LOCK THE PIPELOCK WITH THE CLAMPS

Page 85: Fire Seal Full Presentation

LOCK THE PIPELOCK WITH THE CLAMPS

Page 86: Fire Seal Full Presentation

LOCK THE PIPELOCK WITH THE CLAMPS

Page 87: Fire Seal Full Presentation

LOCK THE PIPELOCK WITH THE CLAMPS

Page 88: Fire Seal Full Presentation

SECURE PIPELOCK TO BULKHEADWITH SELF-TAPPING SCREWS

Page 89: Fire Seal Full Presentation

FINAL RESULT WITHIN 10 - 15 MINUTES!

Page 90: Fire Seal Full Presentation

SQUEEZER A1. Squeezer A2. Firestop Sealant 3000

Corrosion treated steel materialfor applications with limitedwater exposure.

Watertight: 300 kPa (30 mWC)

A0 - A60 approval.

Very simple and fast installation.

Standard plastic pipe sizes:55, 82, 114 and 110 mm

Complete, factory made sealfor single plastic pipes.

Page 91: Fire Seal Full Presentation

SQUEEZER APLASTIC PIPE INSTALLATION

Page 92: Fire Seal Full Presentation

SQUEEZER PLASTIC PIPE INSTALLATION

Page 93: Fire Seal Full Presentation

SQUEEZER PART

Page 94: Fire Seal Full Presentation

PLACE THE SQUEEZER AROUND THE PIPE

Page 95: Fire Seal Full Presentation

PLACE THE SQUEEZER AROUND THE PIPE

To safeguard against the passage of smoke or gas, or to obtainwatertightness the joint beetween the pipe and the steel division should besealed with FireStop Sealant 3000.

Page 96: Fire Seal Full Presentation

LOCK THE SQUEEZER

Page 97: Fire Seal Full Presentation

LOCK THE SQUEEZER

Page 98: Fire Seal Full Presentation

POSITION THE SQUEEZER

Page 99: Fire Seal Full Presentation

SECURE TO BULKHEAD OR DECKWITH SELF-TAPPING SCREWS

Page 100: Fire Seal Full Presentation

FINAL RESULT WITHIN 10 - 15 MINUTES!

Page 101: Fire Seal Full Presentation

SQUEEZER BMULTIPLE PLASTIC PIPES

Page 102: Fire Seal Full Presentation

SQUEEZER B1. Blanket D-24B (Non-combustible calcium silicate fibre)2. FireStop Sealant 3000 (Silicone elastomer)3. Graphite material

Complete, factory made seal formultiple plastic pipes.

Very simple, fast installation.

Ideal for plastic pipes up to 110mm.

Watertight: 250 kPa (25 mWC)

A0 - A60 approval.

Page 103: Fire Seal Full Presentation

REFERENCE LIST – MARINE

T-AKE-1 (NASSCO) Ammunition ShipCharles de Gaulle Aircraft CarrierVistafjord Cruise ShipSea Princess Cruise ShipSilja Symphony Passenger / Car ferrySilja Serenade Passenger / Car ferryFantasy Cruise ShipEcstasy Cruise ShipSong of Norway Cruise ShipSong of America Cruise ShipBirka Princess Cruise ShipSea Godess l & ll Cruise ShipWellamo Passenger / Car ferrySvea Passenger / Car ferryKarhu Ice-breaker

Page 104: Fire Seal Full Presentation

Isabella Passenger / Car ferryFrans Suell Passenger / Car ferryDawn Princess Cruise ShipSun Princess Cruise ShipSuper Carneval Cruise ShipRyndam Cruise ShipRhapsody of the Seas Cruise ShipAmorella Passenger / Car ferryAthena Passenger / Car ferry

REFERENCE LIST – MARINE

Page 105: Fire Seal Full Presentation

REFERENCE LIST – OFFSHORE

Alibaba Sovereign Oil, UKBalmoral Sun Oil, UKBeatrice B Brit Oil, UKBeryl B Mobil, UKBrent A, B, C, D Shell, UKBuchan BP, UKClaymore A Occidential, UKCleeton BP, UKClyde BP, UKCormorant A & North Shell, UKDan F Maersk, DKDraugen Shell, NOFulmar Shell, UKGoodwyn A Woodside, AUSGullfaks A, B, C Stat Oil, NO

Page 106: Fire Seal Full Presentation

Heidrun Conoco, NOHibernia HMDC, CATreasure Hunter Wilhelmsen, NOTroll Shell, NOTyra Danbor, DKValentin Shaskin State Owned, RUVenture SOEP, CAMISP Prirazlomnaya Sevmash, RUJotun Mobil, NOMaccullogh BP, UKMad Dog BP, USAMagnus BP, UKMichael Mirsksinks State Owned, RUMolinpaq Marathon, USAN´Kossa Elf Congo, FR

REFERENCE LIST – OFFSHORE

Page 107: Fire Seal Full Presentation

Oseberg A, B, C Norsk Hydro, NOSafe Gothia Consafe, SESafe Karinia Consafe, SEShell B.D Shell, UKShell C.D Shell, UKShip 137 British Gas, UKSleipner Stat Oil, NOSleipner Vest Stat Oil, NOStatfjord A, B, C Stat Oil, NoTartan A Texaco, UKThebaud SOEP, CAThames Arco Arco, UKULA BP, NOValhall Amoco, NOVesiefrikk Stat Oil, NO

REFERENCE LIST – OFFSHORE

Page 108: Fire Seal Full Presentation

HTTP://WWW.FIRESEAL.COM

INSTALLATIONGUIDES

APPROVALS

MATERIAL SAFETYDATA SHEETS