FIRE REQUIREMENTS
abdul hadi abd hamid
for high rise especially SoHo
azeme azman
![Page 2: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/2.jpg)
DEFINITION
![Page 3: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/3.jpg)
Fire protection in buildings
The UBBL 1984 requires all buildings to have minimum structural integrity based on its usage.
Elements of construction can only be effective as fire breaks if they have the necessary degree of fire resistance
INSULATION INTEGRITY STABILITY
The three criteria of fire resistance:
Guide to fire protection in Malaysia – 3.4
![Page 4: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/4.jpg)
Good building design with fire safety
measures
• Provide adequate fire appliances, fire hydrants & other facilities to assist fire & rescue personnel
• Provide adequate fixed installation, where appropriate, for quick & effective detection & extinguishment of fires
• Designing & installing building services so that they do no assist the spread of fire, smoke or toxic fumes
• Designing & providing adequate and safe escape routes for the occupants of the building
• Selecting materials for the construction which will not promote the rapid spread of fire or generate dangerous smoke
• Subdividing buildings into compartments of reasonable sizes by means of fire resisting walls & floors, providing fire stops to protect openings between floors & compartments
• Designing & constructing the exterior of a building so that fire is unlikely to spread to it from another burning building
![Page 5: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/5.jpg)
PASSIVE FIRE PROTECTION
![Page 6: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/6.jpg)
PURPOSE GROUPS
![Page 7: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/7.jpg)
By LAW - 134
![Page 8: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/8.jpg)
residential + office + shops
MIXED USE BUILDINGS
Where a building contains usage falling under different purpose groups and
each is contained within compartment, by-law 215 of the UBBL allows the
height of each part of the building housing a different purpose group, if they are
vertically separated, to be considered separately for compliance with Schedule
6, 7, 9 in the UBBL
![Page 9: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/9.jpg)
![Page 10: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/10.jpg)
FIRE APPLIANCES
ACCESS
![Page 11: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/11.jpg)
![Page 12: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/12.jpg)
DESIGN NOTES
• Vehicular access to the exterior of a building is needed to enable high
reach appliances to be used & to enable pumping appliances to supply
water & equipment for fire fighting & rescue activities
• Access requirement increase with building size & height
• The table in By- law 140 (above) shows the proportion of the building
perimeter that must be accessible to fire fighting appliances
![Page 13: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/13.jpg)
one-sixth one-half
three-fourth island site
![Page 14: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/14.jpg)
![Page 15: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/15.jpg)
• Away from obstructions such as
street furniture, phone booths,
etc
• Not less than 2m from adjacent
buildings & overhangs
• Between 0.61m to 2.4m from
Fire Appliance Access
• Away from risks vehicular
• Not more than 90m apart from
each other (in new buildings
adjacent to existing
developments, a new hydrant or
hydrants will have to be
provided if there is no hydrant
within 45m radius of the new
building)
![Page 16: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/16.jpg)
EXISTING FIRE HYDRANT(hotel Malaya site)
![Page 17: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/17.jpg)
MEANS OF ESCAPE
![Page 18: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/18.jpg)
By-law 229 – Means of access & fire fighting in buildings over 18.3
meters high
• Must provide gaining access and fighting fire from within the building
consisting of fire fighting access lobbies, fire fighting staircases, fire lifts and
dry or wet rising systems
• Fire fighting access lobbies shall be provided at every floor & the level
distance from the furthermost point of the floor does not exceed 45.75
meters
• Fire fighting access lobbies may be omitted if the fire fighting staircase is
pressurised to meet the requirements of by-law 200
• A fire fighting staircase shall be provided to give direct access to each fire
fighting access lobby & shall be directly accessible from outside the building
at fire appliance access level
• A fire lift shall be provided to give access to each fire fighting access lobby
or in the absence of a lobby to the fire fighting staircase at each floor level
• The fire lift shall discharge directly into the fighting access lobby fire fighting
staircase or shall be connected to it by a protected corridor
![Page 19: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/19.jpg)
MEANS OF ESCAPE is to direct a shortest route to a
place of safety, such as outside the building, or if still
within a building, a protected or isolated passageway,
stairs or refuge areas which lead to the outside
building
![Page 20: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/20.jpg)
![Page 21: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/21.jpg)
![Page 22: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/22.jpg)
STOREY EXIT is a fire rated door to a protected
staircase or a corridor protected with a fire resisting
structure in accordance with the 9th schedule to these
By-laws & in the case of ground floor accommodation
storey exit means a door leading direct to a place
safety outside the building
![Page 23: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/23.jpg)
Arrangement of storey exits
The principle of this clause is that once the escape route is inside a protected zone, then
the route shall remain protected all the way to the final exit.
![Page 24: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/24.jpg)
![Page 25: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/25.jpg)
![Page 26: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/26.jpg)
FIRE LIFTS means lifts capable of being commandered
for exclusive use of firemen in emergency
![Page 27: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/27.jpg)
Design requirement
• Location of fire lifts
• Number of fire lifts
• Numbers of floor to be served
• Lift well/shaft
• Landing doors
• Other requirement for fire lifts
![Page 28: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/28.jpg)
ACTIVE FIRE PROTECTION
SYSTEM
![Page 29: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/29.jpg)
sprinkler system
To detect, control and extinguish a fire
To warn the occupants of the occurrence of fire
![Page 30: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/30.jpg)
sprinkler system
![Page 31: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/31.jpg)
hose reel system
“ intended for the occupant to use during the early stages of fire ”
• Hose reel:
• 30m coverage of each hose
reel
• One hose reel for every
800sq.m of usable floor space
• Located along escape routes
or besides exit doors or
staircase
design requirements
![Page 32: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/32.jpg)
hose reel system
![Page 33: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/33.jpg)
CASE STUDY
City Bank Tower
![Page 34: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/34.jpg)
MENARA CITIBANK
fire safety
HIGH ZONE
Level 36-48
MID ZONE
Level 20-35
LOW ZONE
Level 9-19
>> The fire fighting system of Menara
Citibank is divided into 3 zones
>> One person is in charge in the Fire
Control Room (FCR)
![Page 35: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/35.jpg)
equipments
>>Emergency intercom system provide automatic zoned announcement in the event of fire
>>Smoke detector - corridors
>>Sprinkler - all offices and rooms
>>Alarm sounder- all the offices
>>Break glass - all the offices fire alarm panel
Alarm sounder
Sprinkler
![Page 36: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/36.jpg)
>>Roller shutter -
basement and lobby
>>Pressurization fans-
stairways and lobby
Roller shutter
Pressurization
fans
equipments
![Page 37: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/37.jpg)
>>Hose reel and fire hose
>>CO2 fire extinguishing installations
![Page 38: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/38.jpg)
Motorized
damper
inside outside
![Page 39: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/39.jpg)
Smoke detector
Sprinkler
Alarm sounder
Roller shutter
Pressurization fans
Hose reel & fire hose
Break glass
CO2 fire extinguishing installations
FIRE ALARM
PANEL
MANUAL
equipments
![Page 40: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/40.jpg)
procedures when fire happen
>> The building management office will be in
control-including answering all the coming in calls
>>All lifts will go down automatically
>>The roller shutter activated - at basement &
lobby
>>The pressurization fans on:
- to control the fire from spreading to other area
- help to reduce smoke - especially at the main fire
escape route
>>The air conditioning system turn off
![Page 41: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/41.jpg)
>>When fire occurs at certain level, the evacuation will be starting from the 2 floor below the level and then 2 floor above. This method repeated until every level is covered. This is important to avoid from congestion in the fire escape route.
>>Every floor will be controlled by a warden. Priority will be given to the pregnant women and disable occupants.
procedures when fire happen
FIRE
Firstly evacuated
Secondly evacuated
![Page 42: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/42.jpg)
![Page 43: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/43.jpg)
![Page 44: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/44.jpg)
![Page 45: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/45.jpg)
![Page 46: FIRE REQUIREMENTS](https://reader033.fdocuments.us/reader033/viewer/2022052209/54648b47af795969338b49db/html5/thumbnails/46.jpg)
REFERENCES
• Uniform building By-Laws 1984 (G.N. 5178/85)