FIRE ALARM SYSTEM - MTechmtech-fire.com/wp-content/uploads/2012/08/MA_brochure-highres.pdf · FIRE...

8
CLEVER FIRE SOLUTIONS MA ANALOG FIRE ALARM SYSTEM The MA Analog Range is a clever addressable fire alarm control system capable of interfacing with advanced brain protocols of leading fire detection systems on the market. Its flexible design makes the MA-1000 one of the most powerful and cost effective analog panels available, with quick response time and easy integration to support a wide range of commercial and industrial applications. The minimalistic design of the MA offers advanced functionality to support complex cause and effect programming for industrial, high- tech and military applications, as well as a wide range of public institutions such as hospitals, airports, universities, and others.

Transcript of FIRE ALARM SYSTEM - MTechmtech-fire.com/wp-content/uploads/2012/08/MA_brochure-highres.pdf · FIRE...

Page 1: FIRE ALARM SYSTEM - MTechmtech-fire.com/wp-content/uploads/2012/08/MA_brochure-highres.pdf · FIRE ALARM SYSTEM The MA Analog Range ... (4 lines with 16 characters on each line) •

CLEVER FIRE SOLUTIONS

MA ANALOG FIRE ALARM SYSTEMThe MA Analog Range is a clever addressable fire alarm control system capable of interfacing with advanced brain protocols of leading fire detection systems on the market.

Its flexible design makes the MA-1000 one of the most powerful and cost effective analog panels available, with quick response time and easy integration to support a wide range of commercial and industrial applications.

The minimalistic design of the MA offers advanced functionality to support complex cause and effect programming for industrial, high-tech and military applications, as well as a wide range of public institutions such as hospitals, airports, universities, and others.

Page 2: FIRE ALARM SYSTEM - MTechmtech-fire.com/wp-content/uploads/2012/08/MA_brochure-highres.pdf · FIRE ALARM SYSTEM The MA Analog Range ... (4 lines with 16 characters on each line) •

MA-1000 Analog Addressable Panel

/ 2 /

System Functionality • Four row graphic display that provides a simple and comprehensive menu-driven end-user interface: 64-character

backlit LCD display (4 lines with 16 characters on each line)• Holds up to 150 addressable devises per loop including a mixture of call points, detectors, interfaces, beacons

and loop sounders.• Designed to ensure future expansion: Even after the system has been programmed, the panel can allocate the next

available address without altering any of the existing address number allocation. • Uses soft addressing during commissioning: Addresses are locked until manually altered to enable simple system

additions and deletions without affecting other addresses.• Maintains full system integrity in the event of an external short-circuit fault: The panel’s short circuit isolators on the

devices nearest to each side of the short-circuit open to isolate a fault in the system and drives communication from both ends of the loop to sustain full communication with all system devices.

• Multiple stages and complex cause and effect programming: The panels are designed with a wide range of user controllable functions with three stages of cause-and-effect programming per output device to meet the needs of a wide range of small to large scale projects.

• Four programmable NAC’s: The panel includes four programmable output NAC’s with a maximum load of 1.2A.• Programmable relays: The panel is designed with three programmable relays, one dedicated alarm relay, and one

dedicated trouble relay. • Power Supply: 6.5 amp

Features:• Two Class A Loops, with a future option of four loop

operation• Approved to UL864 9th Edition/ NFPA 2007 Compliant• In accordance with Russian and Israeli fire standards • Menu driven programming• Soft addressing• Up to 150 addressable devices per loop• Short circuit isolators incorporated into each loop device• Four programmable NAC’s• Three programmable relays• One dedicated alarm relay• One dedicated trouble relay• RS232 and RS485• Easy to program• Up to 16 panels on network• 6.5 amp power supply

MTech’s MA-1000 range is an intelligent analog addressable fire alarm control panel with a two-loop configuration, with a future option of a four-loop operation. The MA product series abide to UL864 9th Edition standards, and are in accordance with current standards of the Russian and Israeli Standards Associations.

The MA-1000 panel uses “spur tolerant” soft addressing to minimize installation time and remove the potential for errors associated with manual addressing. It assigns multiple addresses and saves addresses of removed

devices for future use without affecting the remaining devices.

Offered with the MA-1000 is an analog sub-control extension panel, the MA-1000SUB, with multiple interfacing connections to the main panel.

All MTech fire detection system components operate as part of a fully integrated system with its panel, detectors, interfaces and other ancillaries in full compatibility with each other.

Page 3: FIRE ALARM SYSTEM - MTechmtech-fire.com/wp-content/uploads/2012/08/MA_brochure-highres.pdf · FIRE ALARM SYSTEM The MA Analog Range ... (4 lines with 16 characters on each line) •

/ 3 /

Additional Expansion Modules

Analog Sub Control Extension Panel – MA-1000SUBThe MA-1000SUB extension panel is an expansion module featuring four programmable NAC’s, three programmable relays, two Class A loops, 150 addressable devices per loop, 6.5 amplifier, AC power supply and battery backup. Multiple MA-1000SUB extensions can be connected to the MA-1000 main panel with a network card, and the module is capable of independent operation in the event of network failure, transforming it into one of the most powerful analog panels on the market.

Power Booster – MA-1100The MA-1100 power booster is a 4.5 amp notification power expander compatible with MTech’s fire alarm control panels. Up to eight units can be installed on the main panel. Complete with its own AC power, battery charging circuit and backup battery, the MA-1100 has four fully programmable NAC’s, three completely programmable relays, one fire relay and one alarm trouble relays. It is programmed through the main panel.

Remote Annunciator – MA 1050The main control panel has a built-in annunciator with a four line, 64-character backlit LCD display with easy to understand system messages and a user-friendly membrane keypad. It additionally supports up to eight remote annunciators with matching control and display layout with two levels of user codes to limit operating system programming to authorized personnel only. The built-in annunciator also has five system status LEDs for Alarm, Supervisory, Trouble, Silence and AC power. The Reset and Silence buttons on the keyboard are noticeably larger than the rest. The annunciator enclosure can be surface or flush mounted.

Features:• Standalone panel• Internal LCD display • Four programmable NAC’s• Three programmable relays

• Two Class A loops • Up to150 addressable devices per loop • 6.5 amplifier & backup battery• Menu driven programming

• Up to 16 panels on network

Features:• Installation of up to eight units

on the main panel• 4.5 amp power supply

• Backup battery

• Four programmable NAC’s

• Three programmable relays

• One fire relay

• One alarm trouble relay• RS232 and RS485

Features• 64-character backlit LCD display

(4 lines with 16 characters on each line)

• Membrane Keypad• Accepts user codes or fire

fighter’s key (Optional)• Larger Reset and Silence keypad

buttons

• Eight remote installations per FACP • RS-485 interface to panel• On-board Piezo sounder audibly

indicates Alarms, Troubles and Supervisories

• Five status LEDs for Alarm, Supervisory, Trouble, Silence and AC power conditions

Page 4: FIRE ALARM SYSTEM - MTechmtech-fire.com/wp-content/uploads/2012/08/MA_brochure-highres.pdf · FIRE ALARM SYSTEM The MA Analog Range ... (4 lines with 16 characters on each line) •

/ 4 /

Typical Schematic: MA Analog Range

MA-1000 MA-1100

CLEVER FIRE SOLUTIONS

MA-1050Up to 8 panels per local panel

MA-1000 Two Class A LoopsMenu driven programmingSoft addressingUp to 150 addressable devices per loop4 programmable NAC’s3 programmable relays1 dedicated alarm relay1 dedicated trouble relayRS232 and RS485Up to 16 panels on network

MA-TA

MA-3I3O MA-320 MA-320MA-212OR

MB-220 MB-220

MB-PBR

MA-BSH

NAC

NAC

NAC

RS-485

LOO

P-2

LOO

P-1

R5232

Up to 16 panels on network

1

2

3

4

NAC

Page 5: FIRE ALARM SYSTEM - MTechmtech-fire.com/wp-content/uploads/2012/08/MA_brochure-highres.pdf · FIRE ALARM SYSTEM The MA Analog Range ... (4 lines with 16 characters on each line) •

/ 5 /

MA-1100

CLEVER FIRE SOLUTIONS

MA-1000SUB

MA-1050Up to 8 panels per local panel

MB-FLMA-1100 Installation of up to eight units on the main panel 4.5 amp power supplyBackup batteryFour programmable NAC’sThree programmable relays One fire relayOne alarm trouble relayRS232 and RS485

MA-1000SUB 2 Class A LoopsMenu driven programmingSoft addressingUp to 150 addressable devices per loop4 programmable NAC’s3 programmable relaysRS232 and RS485Stand aloneUp to 16 panels on network

MA-340 MA-330 MA-320

MA-IN MA-CP MA-OR

MA-Zone

MB-240 MB-230 MB-220

MB-LI

MB-PBR

Blower

RL

Up to 150 devices per loop

LOO

P-2

LOO

P-1

RS-485

RL

1

2

3

RL

Page 6: FIRE ALARM SYSTEM - MTechmtech-fire.com/wp-content/uploads/2012/08/MA_brochure-highres.pdf · FIRE ALARM SYSTEM The MA Analog Range ... (4 lines with 16 characters on each line) •

MA-S / MA-SH A loop-powered soft addressable wall sounder with built-in short circuit isolators. It offers excellent sound output levels while maintaining low current consumption. LED beacon available with MA-SH. Waterproof versions available.

MA-BSH An intelligent addressable sounder beacon base for sensors or stand-alone device featuring tone selection and volume adjustment, single point connection for sensors, sounders and beacons, and can accommodate a powerful LED beacon (optional).

MA-BSAn intelligent addressable sounder base for sensors or standalone device featuring tone selection and volume adjustment, and single point connection for sensors and sounders, while maintaining low current consumption.

Addressable Analog Detectors

/ 6 /

A variety of soft addressed low current analog detectors are available to operate with the MA addressable alarm system with advanced features, including simple installation, built-in short circuit isolators in each unit, easy to maintain, designed for 360° LED viewing, and more.

Benefits• Quick and simple to install• Single "multi-mode" heat sensor• Common mounting base• Positive "lock" indication• Easy to maintain and service

MA-330Multi-mode heat sensor

MA-320Optical photoelectric smoke detector

MA-340

Photo-thermal smoke sensor

MA-300Standard European base

Addressable Sounders

Features• Built-in short circuit isolators• Aesthetically pleasing low profile

design• Led design with 360° view• Removable detector chamber• Drift compensation

Page 7: FIRE ALARM SYSTEM - MTechmtech-fire.com/wp-content/uploads/2012/08/MA_brochure-highres.pdf · FIRE ALARM SYSTEM The MA Analog Range ... (4 lines with 16 characters on each line) •

MA-ZoneA compact single zone monitor input, capable of interfacing with a zone of up to 20 conventional detectors on an analog fire panel. The module connects to addressable loop and acts as conventional slave under one address.

MA-100PRO ProgrammerRobust and lightweight hand-held programmer that is easy to use with a user-friendly menu structure on a 2 × 40 character LCD display for the programming of all analog devices.

Addressable Loop Devices

InterfacesWe offer an extensive variety of interfaces for the MA Analog Range. Our advanced soft addressed compact devices with short circuit isolators provide solutions to most design requirements, abide to UL864 9th Edition standards, and are in accordance with current standards of both the Russian and Israeli Standards Associations.

/ 7 /

MA-ORAn advanced and compact single channel output unit for a variety of interfaces.

MA-INA compact dry contact input monitoring module used to accept input signals from external equipment such as beam detectors, flow switches, valve monitor switches and others.

MA-TAT-tap of addressable device: Connects to an SLC loop to make a Class B connection to system accessories.

MA-2I20Output module, with a one zone conventional detector, one zone manual call point, two sounder circuits and one relay.

MA-CPCall point surface, acts as a manual call point

Page 8: FIRE ALARM SYSTEM - MTechmtech-fire.com/wp-content/uploads/2012/08/MA_brochure-highres.pdf · FIRE ALARM SYSTEM The MA Analog Range ... (4 lines with 16 characters on each line) •

MTech – Clever Fire Solutions

CLEVER FIRE SOLUTIONS

At MTech, we introduce clever uninterrupted fire detection solutions committed to savings lives and property. With over two decades of experience in all aspects of fire detection and gas extinguishing systems, our design flexibility focuses on making high value products that abide by strict international standards with advanced capabilities and interfacing features that are cost effective to your bottom line.

From the simplest installation to complex multi-building sites, we promise advanced solutions combined with professional consultation and training. MTech products are being integrated into projects in many parts of the world, including the Middle East, Asia, Eastern Europe and Russia.

Kibbutz HasolelimD.N Hamovil 17905, Israel

MTECH Clever Fire Solutions

Our Core Values:• Be the first to introduce clever and cost-effective uninterrupted fire detection solutions to improve life and property

safety • Invest in our experienced multi-lingual team who provide training and on-site consultation and technical support and

forge long term relationships with our customers• Committed to leading-edge product research and development• To be fully compliant with the latest international standards

[email protected]

Tel +972 4 844 5044Fax +972 4 844 5035