Finch II Programming Manual - Titan Logix Corp

38
Finch II Programming Manual TPM 051 Rev 1 February 5, 2016

Transcript of Finch II Programming Manual - Titan Logix Corp

Page 1: Finch II Programming Manual - Titan Logix Corp

Finch II Programming Manual

TPM 051 Rev 1 February 5, 2016

Page 2: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 2 Rev. 1, February 5, 2016

TP

M 0

51

WARRANTY

Please see our Terms and Conditions for details about our product warranty.

PROPRIETARY INFORMATION

The Information disclosed herein contains proprietary rights of Titan Logix Corp. Neither

this document nor the information disclosed herein shall be reproduced or transferred to

other documents, or used or disclosed to others for manufacturing purposes, or for any

other purpose except as specifically authorized in writing by Titan Logix Corp.

Page 3: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 3

Table of Contents

Introduction .............................................................................................................................. 4 1

About this Manual ........................................................................................................... 4 1.1

Disclaimer ....................................................................................................................... 4 1.2

Introduction to the Configuration Utility ............................................................................... 5 2

Overview ......................................................................................................................... 5 2.1

Finch II Configuration ...................................................................................................... 5 2.2

Features .......................................................................................................................... 6 2.3

Finch II Alarms and Relays ..................................................................................................... 8 3

Alarms ............................................................................................................................. 8 3.1

Finch II Relays ................................................................................................................ 8 3.2

Configuring Relay Assignments and Alarming States .................................................... 9 3.3

Optional Alarm Acknowledgement ................................................................................. 9 3.4

Using the Configuration Utility ............................................................................................. 10 4

Configuration Workflow ................................................................................................. 10 4.1

Reading the Current Configurations ............................................................................. 15 4.2

Loading Configuration Settings from a File .................................................................. 15 4.3

Finch II Factory Settings ............................................................................................... 15 4.4

Finch II Firmware Update Utility ........................................................................................... 17 5

Introduction to the Firmware Update Utility .................................................................. 17 5.1

Finch II Firmware Update Utility Overview ................................................................... 17 5.2

Usage ............................................................................................................................ 17 5.3

Firmware Update Workflow .......................................................................................... 18 5.4

Troubleshooting .................................................................................................................... 20 6

Appendix A Finch II Software Installation ................................................................................. 23

Appendix B Finch II Terminal Board ......................................................................................... 32

Appendix C Example 1: Horn on Fill Alarm .............................................................................. 33

Appendix D Example 2: High Level Shutdown System ........................................................... 35

Appendix E Example 3: Typical Crude Oil Trailer .................................................................... 37

Index of Figures Figure 2-1: Finch II Configuration Utility Screen .............................................................................. 5 Figure 4-1: Finch II Programming Kit Connection .......................................................................... 13 Figure 4-2: Finch II Factory Settings .............................................................................................. 16 Figure 5-1: Finch II Firmware Update Utility Screen ...................................................................... 17

Index of Tables

Table 4-1: Relay Configuration Work Flow and Checklist ............................................................. 10

10

Page 4: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 4 Rev. 1, February 5, 2016

TP

M 0

51

Introduction 1

About this Manual 1.1

This manual provides information specific to software configuration of the Finch II

Display. Use of the Finch II Configuration Utility for alarm response, operator control

options and 3rd party devices is shown by example. Refer to the customer’s configuration

details for the actual settings. These details include relay response to alarms, optional

relay controlled devices and settings unique to 3rd party systems that are integrated with

the Finch II alarm system.

This manual contains details for the use of the Finch II Configuration Utility and the Finch

II Firmware Update Utility.

Refer to Application Notes for the specific 3rd party systems.

For all other Finch II information, refer to the Finch II product manual TPM 010.

This Manual Includes:

Introduction to the Configuration Utility Describes Finch II programmability and

the purpose of the Configuration Utility

Finch II Alarms and Relays Description of the TD80 and Finch II

alarms and relays

Configuration Workflow Step-by-step description of the

configuration process

Firmware Update Utility Describes how to use the Firmware

Update Utility

Troubleshooting What to do when the Utility fails to

perform as expected

Software Installation How to install the Configuration and

Firmware Update Utilities

Configuration by Example Provides practical configuration

examples

Only qualified personnel should perform the Finch II configuration. Please read this manual before programming and testing the configuration.

Disclaimer 1.2

The information in this document is subject to change without notice. Titan Logix Corp.

makes no representations or warranties with respect to the contents hereof.

Page 5: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 5

Introduction to the Configuration Utility 2

Overview 2.1

The Finch II provides a flexible system for controlling external devices by TD80 and Finch

II generated alarms. These alarms may provide operator prompts such as lights and

horns or the loading and unloading process may be controlled to prevent unsafe

conditions.

Alarms are assigned to relays by the Configuration Utility to control external devices for

warning and overfill prevention. 3rd party system integration is also supported by the

utility.

Finch II Configuration 2.2

Figure 2-1: Finch II Configuration Utility Screen

Page 6: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 6 Rev. 1, February 5, 2016

TP

M 0

51

The Finch II Configuration Utility allows the installer or maintainer the ability to customize

the Finch display relay responses to alarms generated by the TD80, Finch II and 3rd

party

systems. The Finch display is shipped from the factory with a configuration suited for

most installations. Unique or specialized system operation is set by the configuration

utility.

This software runs on a PC, with Windows XP, 7, 8, 8.1 and 10. It also requires one serial

port or a USB to Serial Adapter for the programming cable. All relay settings are

permanently stored in the Finch II and are reconfigurable at any time in the shop or field

using a laptop with the Configuration Utility and programing cable. A source of vehicle

battery power or an AC power adapter is required for the Finch display.

The settings may be read from a display and transferred to a new unit when being

replaced for repair or upgrade.

Features 2.3

Refer to Figure 2-1 for location of the following controls.

Select COM Port

Choose the COM Port to use for Finch II programming. All of the PC internal and USB to

Serial Converters will be listed.

Set Defaults

Set all settings to their factory defaults.

Menu Bar

File Menu

Open Configuration File

Choose which previously saved file to use for Finch II configuration.

Save Configuration File

Choose a location and file name to store manually entered or read relay

settings.

Exit

Close the Configuration Utility.

Tasks Menu

Refresh COM Ports List

Update the list of available COM Ports when a USB to Serial Converter

is connected after running the Configuration Utility.

About

Identify the Configuration Utility version and copyright notice.

Page 7: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 7

Finch II Relay Assignments

These check boxes connect Finch II and TD80 alarms to a relay. A checked box

indicates that the corresponding relay will respond to the selected alarm.

Air-Weigh LoadMaxx

Refer to the Finch II Air-Weigh LoadMaxx Shutdown System Application Note, TPM 050.

Relay Alarming State

These boxes select the relay alarming action, either energized or de-energized while

alarming.

Program Button

Send the relay settings to a connected Finch II display. These settings are permanently

stored in the Finch display.

Get Current Configuration Button

Read the current settings from a connected Finch II display. These settings may then be

modified or saved for later use.

Page 8: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 8 Rev. 1, February 5, 2016

TP

M 0

51

Finch II Alarms and Relays 3

Alarms 3.1

TD80 transmitter and Finch II generated alarms are:

1. Fall Alarm

2. Fill Alarm

3. High-High (HH) Alarm

4. Spill Alarm

5. Fail Alarm

The Fall and Fill alarms are managed by settings stored in the Finch display. They are

configured from the front panel buttons by the installer or operator. HH and Spill alarms

are determined by settings programmed in the TD80 transmitter. This is done during

transmitter programming only and can’t be changed by any Finch buttons or switches.

The source of Fail alarm is from both the TD80 transmitter and Finch display. Internal

malfunctions or loss of communication between transmitter and display are reported by

the Fail alarm.

3rd

party system alarms are described in an Application Note specific to the system.

Finch II Relays 3.2

The Finch display contains four independently controlled relays. These relays are fuse

protected to limit short-circuit current. Each of the relays has a distinctive name that may

be used to describe the controlled device such as the following:

Relay 1, Engine/Aux Relay

Relay 2, Pump/Aux Relay

Relay 3, Light Relay

Relay 4, Horn Relay

The relays have all contacts; Normally Open (NO), Normally Closed (NC) and Common

(COM) contacts available for power or signal control.

Page 9: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 9

Configuring Relay Assignments and Alarming States 3.3

The factory settings are as follows:

Relay Assignments

SPILL and FAIL Alarm = ENGINE/AUX and PUMP/AUX RELAY

High-High (HH) Alarm = PUMP/AUX RELAY, LIGHT RELAY and HORN RELAY

FILL Alarm = HORN RELAY

FALL Alarm = None

Relay Alarming State

ENGINE/AUX RELAY = Energized when alarming

PUMP/AUX RELAY = De-energized when alarming

LIGHT RELAY = Energized when alarming

HORN RELAY = Energized when alarming

User can acknowledge alarm (Can Ack?)

SPILL/FAIL Alarm = NO

HH Alarm = YES

FILL Alarm = YES

FALL Alarm = YES

All relay actions except Spill and Fail alarms may be acknowledged to clear the alarm

response or locked to maintain the alarm response until the condition clears.

Relays are assigned to alarms with an optional alarming state. The relay may be

energized or de-energized to report an active alarm. See the examples in Appendix C,

Appendix D, and Appendix E.

Relay assignments to 3rd

party systems are described in an Application Note specific to

that system.

Optional Alarm Acknowledgement 3.4

For TD80 and Finch II alarms that are acknowledgeable, pressing ACK will clear the

display and return the relays to their non-alarming state. While the alarm condition is still

present acknowledgement allows loading or unloading to continue.

The Fall, Fill and HH alarms are factory set to be acknowledgeable. Customers may

configure them to be non-acknowledgeable. This prevents the operator from continuing

until the alarm condition has cleared. Spill and Fail alarms cannot be configured as

acknowledgeable. The Spill and Fail alarms are severe enough to require resolution

before continuing to load or unload. Non-acknowledgeable alarms will automatically clear

when the alarm condition is not present.

For example, the Fall alarm may be configured as non-acknowledgeable and connected

to control a pump. When the pump has off-loaded down to the FALL alarm volume, the

pump is shut down and cannot be acknowledged to prevent damage from running it dry.

Page 10: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 10 Rev. 1, February 5, 2016

TP

M 0

51

Using the Configuration Utility 4

Configuration Workflow 4.1

Steps 1 through 3 are for first time configuration planning. Steps 4 through 9 are for

programming an existing configuration.

Use the following checklist and instructions to configure a Finch II display. See Figure 2-1

for the Configuration Utility screen.

Table 4-1: Relay Configuration Work Flow and Checklist

Step 1 List the alarm accessories, high level shutdown and low level prevention system devices

Step 2 Determine the relevant alarms to report

Step 3 Determine the signal or power requirements for the devices

1. Voltage, ground or open circuit device control 2. Voltage and current requirements of the alarm devices 3. Determine the relay alarming states; energized or de-energized

Step 4 Connect the PC, programming cable and power supply to the Finch display. See Figure 4.1 for location details

Step 5 Run the Configuration Utility and select the COM Port connected to the Finch display

Step 6 Set the Relay Assignments, Relay Alarming States and Optional Acknowledgement

Step 7 Program the Finch display

Step 8 Disconnect the PC, programming cable and power supply from the Finch display

Step 9 Verify the settings

Page 11: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 11

Configuration Instructions

Step 1:

Overview:

Planning a new installation of TD80 transmitter, Finch display and alarm devices

begins here. Consider the following:

Do This:

1. Does the operator require notification of approaching high level or low level?

2. Is an automatic high level or low level shutdown required?

3. How will an automatic shutdown system halt the loading or unloading

process?

a. Close a bottom loading valve?

b. Open a hydraulic motor bypass valve?

c. Disengage engine power from the pump?

d. Provide a signal to stationary equipment at the site?

Step 2:

Overview:

Determine which alarms are required from Step 1. Consider the following:

Do This:

1. Does the operator require notification to prepare for a certain event?

a. Use the Fall or Fill alarms to halt loading or unloading at a

predetermined volume.

2. Is an automatic high level or low level shutdown required?

a. Use the High-High and Spill alarms to halt loading at a

predetermined volume or high level.

b. Use the Fall alarm to halt loading at a predetermined low level

volume.

3. Is operator safety or environmental damage a concern?

a. Use the Fail alarm to notify the operator of a system malfunction.

b. Use the Fail alarm to halt loading or unloading.

Note that the Spill and Fail alarms are combined into a single alarm when

assigned to the relays.

Step 3:

Overview:

What devices will the relay control?

Do This:

1. The relays are provided to control resistive loads only. Protective components may be required for inductive loads such as motors and solenoids.

Page 12: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 12 Rev. 1, February 5, 2016

TP

M 0

51

2. Solenoid operated valves a. What voltage and current is required for reliable operation?

3. Is a voltage or ground connection required to energize the device? 4. Will the device provide the correct alarm action when power, ground or an

open circuit is switched by the relay? Is the device required to provide the alarming action when the Finch display is turned OFF (default alarm action when the system is turned off)?

Step 4:

Overview:

Do not apply power at this time. The vehicle accessory power switch is OFF or

the AC power adapter is unplugged. Vehicle battery power or an AC power

adapter may be used for programming. Connect the PC and Finch display to the

programming cable. See Figure 4-1 for connection details. An AC power adapter

rated for 12VDC and at least 500mA is adequate to power the Finch display and

up to two TD80 transmitters. The AC power adapter is not intended to operate

the alarm devices.

Do This:

1. Connect to the power source. When using vehicle power, follow step a. OR for AC power adapter, follow steps b through e.

a. The Finch display power supply is 8VDC to 28VDC. Use a well charged vehicle battery. Do not use a battery charger for programming and testing.

OR

b. At the Finch II Display, remove the plug inserted in the PWR IN socket. See Figure 4-1 for the location.

c. Temporarily unplug all alarm device wiring from the alarm relays, relay 1 through 4.

d. Plug the 2-pin programming power cable into the PWR IN socket. e. Ensure that all alarm devices are disconnected from the Finch

display before programming and testing. These devices will overload and damage the AC power adapter.

Finch II Programming Cable Use

Ensure that the Configuration Utility and USB to Serial Converter software are

installed on a PC. The PC may have a serial port or use a USB to Serial

Converter. See Figure 4-1 for Programming Cable details.

Do This:

1. Connect the Programming Cable 9-pin serial connector to the PC serial port or the USB to Serial Converter.

2. At the Finch II display, remove the plug inserted in the RS 232 socket. See Figure 4-1 for the location.

3. Plug the Programming Cable 5-pin plug into the RS 232 socket on the Finch II circuit board.

Alarm and relay configuration is ready to begin once the Configuration Utility is launched

Page 13: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 13

Figure 4-1: Finch II Programming Kit Connection

Step 5:

Overview:

Run the Configuration Utility. See Figure 2-1 for the software details.

Do this:

1. Click on the desktop icon or filename to run the configuration utility. 2. Apply power to the Finch display by turning on the vehicle’s accessory power

OR plugging in the AC power adapter. 3. Select the correct serial port (COM Port) that is connected to the Finch

display.

AC Power

Adapter

Programming

Power Cable

USB to Serial

Converter

Programming

Cable

PWR IN Socket

RS 232 Socket

Page 14: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 14 Rev. 1, February 5, 2016

TP

M 0

51

Step 6:

Overview:

Relay configuration

Do This:

1. Select the Relay Assignments, Relay Alarming State, Acknowledgement

(Can Ack?) and 3rd

party check boxes. These were determined in Steps 1

through 3.

Step 7:

Do This:

1. Click the Program button. 2. Verify that programming was completed without error.

Step 8:

Overview:

Programming kit disconnection

Do This:

1. Turn off power to the Finch display. 2. Disconnect the programming cable from the PC and Finch display 3. Disconnect the power cable if an AC power adapter was used. 4. Reinsert the RS 232 plug into the terminal board. 5. Reconnect all disconnected wiring.

Step 9:

Overview:

It is recommended to test the alarm settings. A TD80 transmitter and probe is

required for testing when the Finch display is programmed away from the vehicle.

Do This:

1. Exercise the Fall, Fill, High-High and Spill alarms. See the Finch II product manual TPM 010, section 2.6.2 for the test and verification details.

2. The Fail alarm may be tested by temporarily disconnecting the TD80 transmitter from the Finch display.

Page 15: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 15

Reading the Current Configurations 4.2

The Configuration Utility also reads the current settings.

1. Connect the PC, power source, programming cable and Finch display as in the

programming Step 4.

2. Run the Configuration Utility. Do NOT click the Program button.

3. Apply power to the Finch display.

4. Click the Get Current Configuration button.

5. The window will fill in the checkboxes with the current Finch display settings.

6. These settings are then saved by clicking File>Save Configuration File and

naming the file something meaningful such as vehicle or trailer number and

compartment.

The saved file may be opened later to configure a newly installed display or one that has

been replaced for repair.

Loading Configuration Settings from a File 4.3

Configuration files may be stored on the PC hard drive, SD card or USB Flash drive for

safekeeping. These files are then used to restore a Finch display to the required settings.

1. Connect the PC, power source, programming cable and Finch display as in the

programming Step 4.

2. Run the Configuration Utility.

3. Apply power to the Finch display.

4. Click File>Open Configuration File and select the file.

5. The window will fill in the checkboxes with the settings.

6. Continue to program the Finch display from the programming Step 5.

Finch II Factory Settings 4.4

The following screenshot shows the Finch II factory settings. The Set Defaults button

restores the Finch II to this configuration.

Page 16: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 16 Rev. 1, February 5, 2016

TP

M 0

51

Figure 4-2: Finch II Factory Settings

Page 17: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 17

Finch II Firmware Update Utility 5

Introduction to the Firmware Update Utility 5.1

The Finch II Firmware Update Utility allows the installer or maintainer the ability to update

the Finch display to the latest Firmware released by Titan Logix Corp. Updated firmware

can provide new features or fix issues.

Finch II Firmware Update Utility Overview 5.2

Figure 5-1: Finch II Firmware Update Utility Screen

This software runs on a PC, with Windows XP, 7, 8, 8.1 and 10. It also requires one serial

port or a USB to Serial Adapter for the programming cable. A source of vehicle battery

power or AC power adapter is required for the Finch display.

The firmware version is visible during startup, the Finch display first shows 888888. The

screen then shows F in the first digit with the following digits showing the firmware

version. E.g. F 1.06.00 – means that firmware version 1.06.00 is installed.

A log of firmware update activity is stored in C:\Temp\FinchII\ on the local drive.

Usage 5.3

Select COM Port

Choose the COM Port to use for Finch II programming. All of the internal serial

adapters and any USB to Serial Converters will be listed.

Menu Bar

Page 18: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 18 Rev. 1, February 5, 2016

TP

M 0

51

File Menu

Load Finch II FW File

Choose a Titan Logix Finch II Firmware file to load into a Finch

display.

Exit

Close the Firmware Update Utility.

Tasks

Refresh COM Ports List

Update the list of available COM Ports when a USB to Serial Converter

is connected after running the Firmware Update Utility.

About

Identify the Firmware Update Utility version and copyright notice.

Update Firmware

Send the new firmware to a connected Finch display. The new firmware will be

permanently stored on the Finch display.

Firmware Update Workflow 5.4

Step 1:

Do not apply power at this time. Vehicle battery power or an AC power adapter

may be used for programming. Connect the PC and Finch display to the

programming cable. See Figure 4-1 for connection details. An AC power adapter

rated for 12VDC and at least 500mA is adequate to power the Finch display and

up to two TD80 transmitters.

Do This:

1. Connect to the power source. When using vehicle power, follow step a. OR for AC power adapter, follow steps b through e.

a. The Finch display power supply is 8VDC to 28VDC. Use a well charged vehicle battery. Do not use a battery charger for programming and testing.

OR

b. At the Finch II Display, remove the plug inserted in the PWR IN socket. See Figure 4-1 for the location.

c. Temporarily unplug all alarm device wiring from the alarm relays, relay 1 through 4.

d. Plug the 2-pin programming power cable into the PWR IN socket. e. Ensure that all alarm devices are disconnected from the Finch

display before programming and testing. These devices will overload and damage the AC power adapter.

Finch II Programming Cable Use

Page 19: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 19

Ensure that the Firmware Update Utility and the USB to Serial Converter

software are installed on a PC. The PC may have a serial port or use a USB to

Serial Converter. See Figure 4-1 for Programming Cable details.

Do This:

1. Connect the Programming Cable 9-pin serial plug to the PC serial port or the USB to Serial Converter.

2. At the Finch II display, remove the plug inserted in the RS 232 socket. See Figure 4-1 for the location.

3. Plug the Programming Cable 5-pin plug into the RS 232 socket on the Finch II circuit board.

Step 2:

Run the Firmware Update Utility.

1. Click on the desktop icon or filename to run the firmware update utility. 2. Apply power to the Finch display. 3. Select the correct serial port (COM Port) that is connected to the Finch

display.

Step 3:

Firmware File selection

1. Select the File Menu >> Load Finch II FW File. 2. Select the firmware file provided by Titan Logix Corp.

Step 4:

Program the firmware

1. Click the Update Firmware button.

2. The Finch II display will show “boot” while the Utility shows programming progress.

3. Verify during boot that the new firmware was installed.

Page 20: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 20 Rev. 1, February 5, 2016

TP

M 0

51

Troubleshooting 6

The following troubleshooting steps cover some of the most common problems encountered

in using both the Configuration Utility and the Firmware Update Utility.

Find the description below that best matches the trouble indications. Perform the “What to

do” steps in order to identify the issue and try each item in the “Remedy” to resolve the

issue.

1. No COM ports are available

WHAT TO DO: DETAILS: REMEDY:

a. Ensure the COM port list is up to date Refresh the list of COM ports Select Tasks>Refresh COM Ports List

b. Ensure that COM port drivers are installed

USB to Serial Converter drivers may not be installed. These are not provided by Titan Logix.

Refer to the USB to Serial Converter manufacturer for the drivers

2. Cannot get the current configuration

WHAT TO DO: DETAILS: REMEDY:

a. Clicking on “Get Current Configuration” shows an error message “Disconnected. Please select a COM port.”

A COM port must be selected. In the top right corner of the screen. See Figure 2-1. Select a COM port or refer to Troubleshooting 1 above.

b. Clicking on “Get Current Configuration” shows an error message “Unable to read configuration from device.”

The Finch II may not be connected to the COM port.

i. Ensure that the programming cable is connected properly. See Figure 4-1. ii. Possibly defective cable. Replace the cable. iii. Possibly defective Finch II display. Replace the display.

Page 21: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 21

3. Cannot program a configuration or firmware

WHAT TO DO: DETAILS: REMEDY:

a. Clicking on “Program” or “Update

Firmware” shows an error message

“Disconnected. Please select a COM

port.”

A COM port must be selected. In the top right corner of the

screen. See Figure 2-1.

Select a COM port or refer

to Troubleshooting 1 above.

b. Clicking on “Program” or “Update

Firmware” shows an error message

“Unable to read configuration from

device.”

The Finch II may not be powered or

may not be connected to the COM

port.

i. Ensure that the

programming cable is

connected properly and that

the Finch II is powered. See

Figure 4-1.

ii. The programming cable

may be defective. Try with

another cable

iii. The Finch II display may

be defective. Try with

another display.

4. Cannot open a configuration file

WHAT TO DO: DETAILS: REMEDY:

a. Ensure the correct file is being opened

Finch II display configuration files end in .f2c

Select correct configuration file.

b. File is corrupt File can become corrupt due to several computer issues.

i. Refer to a backup file. ii. Recreate the settings and save a new configuration file.

Page 22: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 22 Rev. 1, February 5, 2016

TP

M 0

51

5. Finch II does not reflect all configured settings

WHAT TO DO: DETAILS: REMEDY:

a. Program the settings The settings must be sent to the Finch II before they become active

i. Connect a Finch II programming cable. ii. Select the desired settings iii. Press the Program button

b. Check Firmware version The “Can Ack?” feature is only available in Finch II Firmware 1.05.00 and newer. The Air-Weigh LoadMaxx feature is only available in Finch II Firmware 1.06.00 and newer.

i. Disconnect power from the Finch II. ii. During startup the Firmware version is displayed. iii. If the Firmware version is older than the feature you wish to enable, update the Firmware.

6. Finch II display does not show “boot” during Firmware Update

WHAT TO DO: DETAILS: REMEDY:

a. Clicking on “Update Firmware” shows an error message “Programming failed. Firmware update unsuccessful”

The Finch II display may have failed to enter programming mode.

i. Disconnect power from the Finch II display. ii. Setup the Firmware Update Utility with the correct COM port and Firmware File. iii. While holding both the HORN and LIGHT test buttons connect power to the Finch II display. (The display will show “boot” iv. Within 10 seconds press the “Update Firmware” button in the Firmware Update Utility

Page 23: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 23

Appendix A Finch II Software Installation

The Finch II Programming Kit contains a Titan provided software installation CD for the

Configuration and Firmware Update Utilities.

Most PCs will use the USB to Serial Adapter that is supplied with the kit. The driver for

this adapter must be installed according to the manufacturer’s instructions. Install the

USB to Serial adapter and resolve all issues with that first, and then install the Finch II

Configuration and Firmware Update Utilities by following the instructions below.

The USB to Serial Adapter package includes a CD that contains drivers and owner’s

manuals for various Windows versions. For the most recent USB to Serial Adapter driver

for your Windows version, see: http://www.tripplite.com/support/model/mid/USA19HS

A.1 Configuration and Firmware Update Utility Installation

1. Close all programs. Do not run any other programs during installation.

2. Insert the Installation CD into any available CD/DVD drive.

3. The setup should begin immediately. Under some versions of Windows, there might

be a pop-up box prompting you to either select “Setup.exe” or browse the CD. In this

case, just select “Setup.exe” to run the installation.

Figure A-1: Finch II Configuration Utility Installation

If the installer does not automatically begin, see Installation CD Troubleshooting section

A.4

4. Click Next when the following screen is displayed and follow the instructions of the

Setup Wizard. See the screenshots below. Follow the instructions in section A.2 for

first time installation or A.3 for reinstallation or updating.

Page 24: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 24 Rev. 1, February 5, 2016

TP

M 0

51

A.2 First Time Installation

Step 1

Step 2

Step 3

Page 25: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 25

Step 4

Step 5

Step 6

**May be prompted to enter admin privileges prior to

step 6.

Page 26: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 26 Rev. 1, February 5, 2016

TP

M 0

51

Step 7

Step 8

Step 9

Step 10

Page 27: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 27

Step 11

Step 12

Step 13

**May be prompted to enter admin privileges prior to

step 11.

Page 28: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 28 Rev. 1, February 5, 2016

TP

M 0

51

A.3 Reinstallation or Update

Step 1

Step 2

Step 3

Step 4

Page 29: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 29

Step 5

Step 6

Step 7

Step 8

Page 30: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 30 Rev. 1, February 5, 2016

TP

M 0

51

Step 9

Step 10

Step 11

Page 31: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 31

A.4 Installation CD Troubleshooting

Installing the Software Manually

1. The setup should begin immediately, but if the computer is not setup for auto-run

when you insert a CD into the CD drive, you can do the following:

a. Go to Start menu.

b. Go to My Computer.

c. Right-click on the CD drive where the installation CD is in.

d. Click Explore.

e. Double-click on Setup.exe.

Page 32: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 32 Rev. 1, February 5, 2016

TP

M 0

51

Appendix B Finch II Terminal Board

Finch II displays have been produced in two different versions, Revision A and Revision B.

Finch II revision A displays are obsolete and no longer in production. The wiring differences

are at the Power Switch terminals. Revision A has an ON/OFF power control switch at

connector #2, see Figure B-1. Revision B does not have the power control switch connector,

see Figure B-2. The revision is identified on the lower right side of the terminal board, near

the PWR IN connector.

Refer to the terminal board drawings below to determine if you have a revision A or B board.

All wiring diagrams show the Revision A Power Switch terminals. Disregard these

connections for revision B boards. Minor variation in the revision is indicated with a number

after the revision letter, for example REV: B.1 in Figure B-2. The minor variation does not

affect wiring or operation.

Figure B-1, Finch II Terminal Board, Revision A

Figure B-2: Finch II Terminal Board, Revision B

Page 33: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 33

Appendix C Example 1: Horn on Fill Alarm

1. Horn sounds at the predetermined Fill and HH alarm volume.

2. The horn is installed on Relay4, HORN relay using the COM and NO contacts.

3. The HORN relay is energized when alarming.

4. Factory settings are shown. Highlighted boxes apply to this example. All other settings don’t affect the system operation for the example.

Figure C-1: Settings for Horn on Fill Alarm

Page 34: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 34 Rev. 1, February 5, 2016

TP

M 0

51

Figure C-2: Horn on Alarm Wiring Schematic

Page 35: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 35

Appendix D Example 2: High Level Shutdown System

1. Horn sounds at a predetermined Fill and HH alarm volume.

2. The horn is installed on Relay4, HORN relay using the COM and NO contacts.

3. The HORN relay is energized when alarming.

4. Red light is on while the HH alarm is active.

5. The Red light is installed on Relay3, LIGHT Relay using the COM and NO

contacts.

6. The LIGHT relay is energized when alarming.

7. Solenoid is energized to permit loading, de-energized when HH, Spill or Fail

alarms are active.

8. The solenoid is installed on Relay2, PUMP Relay using the COM and NO

contacts.

9. The PUMP Relay is de-energized when alarming.

10. Green light indicates loading is permitted when the solenoid is energized.

11. The Green light is installed on Relay2, PUMP Relay using the COM and NO

contacts.

12. Factory settings are shown. Highlighted boxes apply to this example. All other

settings don’t affect the system operation for the example.

Figure D-1: Settings for High Level Shutdown System

Page 36: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 36 Rev. 1, February 5, 2016

TP

M 0

51

Figure D-2: High Level Shutdown System Wiring Schematic

Page 37: Finch II Programming Manual - Titan Logix Corp

TP

M 0

51

FINCH II Programming Manual

Rev. 1, February 5, 2016 Page 37

Appendix E Example 3: Typical Crude Oil Trailer

1. Horn sounds at a predetermined Fill and HH alarm volume.

2. The horn is installed on Relay4, HORN Relay using the COM and NO contacts.

3. The HORN relay is energized when alarming.

4. Solenoid is energized to permit loading, de-energized when HH, Spill or Fail

alarms are active.

5. The solenoid is installed on Relay2, PUMP Relay using the COM and NO

contacts.

6. The PUMP Relay is de-energized when alarming.

7. Factory settings are shown. Highlighted boxes apply to this example. All other

settings don’t affect the system operation for the example.

Figure E-1: Settings for Typical Crude Oil Trailer

Page 38: Finch II Programming Manual - Titan Logix Corp

FINCH II Programming Manual

Page 38 Rev. 1, February 5, 2016

TP

M 0

51

Figure E-2: Typical Crude Oil Trailer Wiring Schematic