Energy conservation in textile industry
![Page 2: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/2.jpg)
Title of paper :
Energy conservation experience in a
textile Printing factory
Author:
C. Chullabodhi & s. Wangsupakukosol
![Page 3: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/3.jpg)
This paper reports on the energy conservation study
carried out in a textile printing factory
The investigation focused on 5 process equipments
namely boiler, cabinet dryer, color fixing dryer, hot
water tanks, and cylindrical dryer
Introduction
![Page 4: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/4.jpg)
PRODUCTION PROCESSES
The layout of the processes is shown
![Page 5: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/5.jpg)
ENERGY CONSUMPTION
Amount of steam was used as a heating medium in the drying cabinet, the colour
fixing dryer, the hot water tanks and the cylindrical dryers.
Electricity was used in driving pumps, fans, blowers, rollers, screw conveyors and
the cylindrical dryers.
ANALYSIS OF ENERGY UTILIZATION EFFICIENCY
The study concentrated on thermal energy, whereby the processes that employed
large amount of heat would be investigated, i.e. boiler, cabinet dryer, colour fixing
dryer, hot water tanks, and the cylindrical dryers
![Page 6: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/6.jpg)
Boiler
horizontal fired-tube type with 7 ton/h capacity at the steam pressure of 4.92 bar. It
operated 12 hours
Filtered water from a nearby canal was used as feed water with no other treatment or
preheat. Sawdust with the average moisture content of 31.1 % was used as fuel.
By direct measurements of the amounts of feed water, fuel, ashes, unbumt carbon, and the
percentages of O2 and CO in the flue gases, the boiler efficiency was found to be 48.38 %
with the amount of boiler heat transfer loss being 6.32 % of the energy inputs.
![Page 7: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/7.jpg)
Cont… energy balance system for high heat value
Boiler efficiency calculated as
![Page 8: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/8.jpg)
Cabinet Dryer
It was an insulated rectangular box of size, 2.4 m x 5 m x 2.45 m, with the drying
heat being obtained from a set of steam pipes located at the lower half of the box.
The printed fabric was fed into the cabinet, through an opening adjacent to the
printing machine, at a constant rate by means of motor-driven rollers.
The moisture was drawn out through a fan outlet located at the top wall. There were
2 dryers in operation.
The dryer effectiveness was found to be 3.29 MJ/kg of the evaporated moisture
with amount of heat loss being 12.9% of the energy units
![Page 9: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/9.jpg)
The analysis of dryer performance of crreid out by energy balance
equation
Where, Mwp = amount of fabric moisture evaporated
Hwp = Enthapy of fabric moisture at inlet
hs = Enthapy of fabric of inlet steam
mp = Feeeding rate of drying fabric
cp = Specific heat of fabric
Tpi = Temperature of entering fabric
Qs = Heat loss from cabinet
hw = Enthalpy from condensate steam
Tpo = Temperture of cabinet fabric
Hv = Enthalpy of evaporated vapour
![Page 10: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/10.jpg)
Surface energy index used to performance of system
SEC value of one unit dryer 2.056 Mj/kg of dry fabric
![Page 11: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/11.jpg)
Color fixing dryer
Energy balance equation for this system
SEC value of fabric 898.1 KJ/kg
![Page 12: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/12.jpg)
![Page 13: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/13.jpg)
Hot water tanks
![Page 14: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/14.jpg)
Cont….
Energy balance equation
SEC value can also be estimated by
SEC value of fabric 10.66 MJ/kg
![Page 15: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/15.jpg)
![Page 16: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/16.jpg)
Cylindrical dryers
![Page 17: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/17.jpg)
Energy balance equation for the system
SEC value of fabric 3.487 MJ/kg
![Page 18: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/18.jpg)
Saving opportunities
![Page 19: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/19.jpg)
Saving opportunities
![Page 20: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/20.jpg)
Implementations
Boiler
Cabinet Dryer
Cabinet Dryer
![Page 21: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/21.jpg)
Implementations
Cylindrical Dryers
![Page 22: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/22.jpg)
Implementations
Hot Water Tanks
![Page 23: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/23.jpg)
Results and discussions
![Page 24: Final presentation on energy conservation in textile industry](https://reader034.fdocuments.us/reader034/viewer/2022052400/5595ddbb1a28ab11728b47a4/html5/thumbnails/24.jpg)
conclusion
This paper reports on the energy conservation study carried out in a textileprinting factory of 6,671 ton/year capacity.
The investigation focussed on 5 process equipments namely boiler, cabinetdryer, colour fixing dryer, hot water tanks,and cylindrical dryer.
After energy auditing works had been performed, 9 saving opportunitieswere identified, which would require invesment ranging from nothing to 2million Baht, with the corresponding payback period of zero to themaximum value of 3.3 years.
Four of the suggested measures were subsequently implemented,
with the resulting saving of 5.426 million Baht per year.
The process specific energy consumption value was also found to decrease byabout 30%.
These findings seem to indicate that there are considerable potential toimprove energy utilization in this textile subsector.