Final plc features
-
Upload
amitkahire -
Category
Documents
-
view
118 -
download
2
Transcript of Final plc features
SMS Mobile Alert (GSM TECHNOLOGY) PLC Features
Network Connection via Ethernet
? PLC Based Control System Make - Allen Bradley
?PC Communication Via Ethernet
?PLC Based Scanner System
?PLC Based Safety Control System to Protect the Chambers from Overshoot and Undershoot
of Temperature and Humidity
?Auto Changeover of Master Sensor In Case of Failure
?Auto Switch Over of Refrigeration System in Case of Failure
?Auto Change Over of Steam Generator in Case of Failure
?Online Monitoring on Graphic LCD 3.8" Touch Screen Display
?Alarm for Low Water Level with Reset System to Protect Steam Generator System.
?Password Protected Door Opening with Reason Master.
?Password Protected Chamber On / Off.
?Password Protected Set Value Change
? Password Protected Settable Print Frequency F or Master & Scanner
?? Password Protected Restore Factory Setting
?Snooze Hooter System.
?Event Logger Facility.
?Actual Status Monitoring of Major Utilities (Sensor, Ref System, Steam Generation).
?GSM Alarm System (Mobile Aler t).
For information log on: www.mackpharmatech.com For information log on: www.mackpharmatech.com
PLC System
Setting Parameters
Safety Cut Off Details
Crucial Controls
Events
Set Master Temperature / Humidity
Change Master / Scanner Print Frequency
Set Safety Temperature Higher / Lower Cut Off (°CHC1, °CHC2, °CLC1, °CLC2)
Set Safety Humidity Higher / Lower Cut Off (%RH HC1, %RH HC2, %RH Lc1)
Temperature Higher Cut Off ON / OFF
Temperature Lower Cut Off ON / OFF
Humidity Higher Cut Off ON / OFF
Humidity Lower Cut Off ON / OFF
Power ON / OFF
Equipment Switch ON / OFF
Cooling ON / OFF
Humidity ON / OFF
Heating ON / OFF
Door OPEN / CLOSE
Steam Generator A FAILURE / OK
Steam Generator B FAILURE / OK
High Temperature Thermostat ON / OFF
Compressor Auto / Manual Mode Setting Change
Change Compressor Cycle Time Changeover
Steam Generator Changeover Time Delay
Setting Parameters
Safety Cut Off Details
Crucial Controls
Events
Touch Screen Display
Password Based Door Access System
PLC Based Password Protected Door Access System With Reason Master:
The door access system grant permission based on password entered.
When access is granted, the door is unlocked for a predetermined time.
This transaction is recorded through DAAS software with a reason given by user.
This record will reflect in Event Audit Trail with Date Time stamp.
PLC Based Auto changeover Master Sensor In Case Of Failure:
Sensor measures temperature and relative humidity.
When controlling sensor fails, it automatically switches over to stand by sensor.
Auto changeover Master Sensor