Final board services

2
UBBL – Pipe and Service Duct By Law – 84 Suitable measures should be taken to prevent penetration of dampness and moisture inside the building By Law – 123 Adequate spaces to accommodates pipes, stop cocks to allow repair, modification, extension, maintenance and access to ducts or enclosure. Sufficient amount of valves are used in different pipe locations, allow easier repairing and maintenance of system Water tank situated on rooftop level, allowing gravity force to channel water to entire building without needing support to restore Electrical By-Laws Electrical Supply ACT 197 ( ACT 1447) Regulation 15 : Apparatus, Conductor, Accessory, etc. Any conductor or apparatus that is exposed to weather, water, corrosion under heating or used in inflammable surroundings or in an explosive atmosphere shall be constructed or protected in such as manner as to prevent danger Regulation 16 : Switch fuse Switch , Circuit Breaker, Contractor, Fuse, etc. 3) Any fuse or Circuit breaker shall be : (a) Constructed and arranged in such a manner so as to break the current when it exceeds a given value for such as sufficient time to prevent danger (b) Constructed guarded or placed in a manner as to prevent danger or overheating arcing or from the scattering of hot metal or other substances or enclosure Electrical System Cold and Hot Water Supply System Schematic diagram of Cold and Hot water Supply system Ground Floor Plan N.T.S First Floor Plan N.T.S Ground Floor Plan N.T.S First Floor Plan N.T.S CHRISTIODY ( 0304191)

Transcript of Final board services

Page 1: Final board services

UBBL – Pipe and Service Duct

By Law – 84

Suitable measures should be taken to prevent penetration of dampness and moisture inside

the building

By Law – 123

Adequate spaces to accommodates pipes, stop cocks to allow repair, modification, extension,

maintenance and access to ducts or enclosure.

Sufficient amount of valves are used in different pipe locations, allow easier repairing and

maintenance of system

Water tank situated on rooftop level, allowing gravity force to channel water to entire building

without needing support to restore

Electrical By-Laws

Electrical Supply ACT 197 ( ACT 1447)

Regulation 15 : Apparatus, Conductor, Accessory, etc.

Any conductor or apparatus that is exposed to weather, water, corrosion under heating

or used in inflammable surroundings or in an explosive atmosphere shall be

constructed or protected in such as manner as to prevent danger

Regulation 16 : Switch fuse Switch , Circuit Breaker, Contractor, Fuse, etc.

3) Any fuse or Circuit breaker shall be :

(a) Constructed and arranged in such a manner so as to break the current when it

exceeds a given value for such as sufficient time to prevent danger

(b) Constructed guarded or placed in a manner as to prevent danger or overheating

arcing or from the scattering of hot metal or other substances or enclosure

Electrical System Cold and Hot Water Supply System

Schematic diagram of Cold and Hot water Supply system

Ground Floor PlanN.T.S

First Floor PlanN.T.S

Ground Floor PlanN.T.S

First Floor PlanN.T.S

CHRISTIODY ( 0304191)

Page 2: Final board services

Sewerage System By-Laws

Law of Malaysia ACT 133

No water pipe, stack pipe or down spout to be used for conveying surface water from any

premises shall be used or permitted to serve or to act as ventilating shaft to any drain or

sewer

Separation of pipe usage between soil waste and ventilating pipe to ensure efficiency and

sanitary of building. It also ensure the safety from the health threat to occupant

UBBL – Drainage system

All roof of building shall be constructed as to drain effectively to suitable and sufficient

channels, gutter, chutes, or thoughts which shall be provided in accordance with the

requirements of these by laws for receiving and conveying all water which may fall on and

off from the roof.

Sewerage System Drainage and Storm System

Sump Down Pour pipe Gutter Component :

Ground Floor PlanN.T.S

Roof PlanN.T.S

Schematic diagram of Drainage and storm

water system

CHRISTIODY ( 0304191)

First Floor PlanN.T.S