Filters Pressure SF - RF

33
Quality and Service Worldwide Filters

description

FILTROS DE PRESION DE LA MARCA STAUFF

Transcript of Filters Pressure SF - RF

Page 1: Filters Pressure SF - RF

Quality and ServiceWorldwide

Filters

Page 2: Filters Pressure SF - RF

PRESSURE FILTERS SF SERIES

FIL

TR

AT

ION

3/00

86

TECHNICAL SPECIFICATIONS/OPTIONS

Construction – In-line assembly, with threadedmounting holes on top of head

Filter head – Spheroidal graphite cast iron

Filter bowl – Cold drawn steel

Seals – O-Rings NBR (Buna-N),FPM (Viton), EPDM (Ethylene-propylene), Support ring PTFE

Port connection – NPT, SAE “O”-Ring thread,SAE Code 61 & 62 flange

Operating press. max. – 6000 psi (420 bar)

Proof pressure – 9000 psi (630 bar)

Burst pressure – >18000 psi (1260 bar)

Temperature range – -10°C up to +100°C14°F to 212°F

Bypass valve – Allows unfiltered oil to bypassthe contaminated elementonce the opening pressure of87 psi +7 psi (6 bar + 0.5 bar)has been reached

Reverse flow – Allows reverse flow through thevalve filter head without back flushing

the element

Contamination Indicator

Filter Head

Valve

Filter Element

Filter Bowl

Non-return – Prevents draining of the deliveryvalve line during element change

– Note: System Pressure must be relieved before element change out

Multi-function – Forward bypass, reverse flowvalve capability, and non return valve

(opening pressure 87 psi +-7 psi(6+-0.5 bar) ∆p all in one valve

Contamination – Visual, 72 psi+-7 psi (5+-0.5 bar) indicators ∆p actuating pressure

– Electrical, 72 psi+-7 psi (5+-0.5 bar)∆p Visual/electric, 72 psi+-7 psi (5+-0.5bar) ∆p (12 V, 24 V, 110 V, 220 V versions)

Filter elements – Filter material specification,B, D, E, G, N, S. low collapse;rating 430 psi (30 bar) ∆p

– Filter material specification,A, C, F, H, T, W. high collapse;rating 3000 psi (210 bar) ∆p

Media – Mineral oils; other fluids on request

TECHNICAL DATASTAUFF high pressure filters are de-signed for in-line hydraulic applications,with a maximum operating pressure of6000 psi (420 bar). Used together withSTAUFF filter elements, a high efficiencyof contaminant removal is assured. Thehigh dirt holding capacity of theelements ensures long service life and, asa result, reduced maintenance.

Page 3: Filters Pressure SF - RF

PRESSURE FILTERS SF SERIES

FIL

TR

AT

ION

3/00

HV - O Non-bypass standard insert with no valvefunction. High collapse elements 3000 psi (210bar ∆p) are normally used with this valve.

HV - B Bypass valve which allows oil to bypass theelement when the differential pressure across theelement reaches 87 psi +7 psi (6+0.5 bar). (Otherpressure settings available on request). Theopening pressure should be higher than the ∆psetting of an optional contamination indicator.Low collapse 430 psi (30 bar ∆p) elements arenormally used with this valve.

HV - R Reverse flow valve is used in systems where thereis flow in reverse through the filter. It allowsreverse flow without back-flushing the elementbut does not filter in the reverse direction. Highcollapse elements 3000 psi (210 bar ∆p) arenormally used with this valve.

A A A A A

B

A

VALVE OPTIONS

HV-O HV-B HV-R HV-N HV-M

Flow characteristics of the valves see page 91.

The optional valves are fitted as an insert in the filter head and incorporate the spigot on which the element seals. The valve is selected to suit the filter application.

87

CODE VALVE TYPE

ONon-bypass standard insert without any valve

B Bypass ValveR Reverse Flow ValveN Non Return ValveM Multi-Function Valve

FILTER GROUP014/030

045/070

090/160

PRODUCT TYPEHV–Valve

HV - M - 045/070

ORDERING INFORMATION

HV - N Non-return valve This valve prevents the oilin the delivery line from draining out whilethe filter is being serviced. High collapseelements 3000 psi (210 bar ∆p) are normally used with this valve.

HV - M Multi-function valve This valve combines the by-pass, the reverse flow, and the non-return functions in one unit. The by-passopening pressure is 87 psi +7psi (6+0.5 bar)∆p with other opening pressures available onrequest. The opening pressure should behigher than the ∆p setting of an optionalcontamination indicator.

B

A

B

A

B

A

B

A

Page 4: Filters Pressure SF - RF

PRESSURE FILTERS SF SERIES

FIL

TR

AT

ION

3/00

STAUFF pressure filters have a range of contamination indicators available as an option. If no indicator is specified, the port is sealedby a plug (HI-O). The contamination indicators are actuated by the differential pressure (∆p) across the element and the specialpiston design minimizes the effects of peak pressures in the system. An optional thermostatic lockout (thermo-stop) is available toprevent false indication under cold start conditions. Fluid temperature must be at least 68°F (20°C) for the indicator to function.

G 1/2

25.4

10.5

1.00

".4

1"

G 1/2

25.4

271.

00"

1.06

"

G 1/2

25.4

751.

00"

2.95

"

G 1/2

25.4

801.

00"

3.14

"

SL

1

3

MP

2

SL

1 (+)

3

2

CONTAMINATION INDICATORS

HI-O HI-A HI-V HI-E HI-P...

Resistive Inductive Voltage Load Load

V Amps Amps

12 15.00 15.00

24 8.00 7.00

110 0.50 0.20

220 0.25 0.10

Rated Capacity HI-E and HI-P

Alternating Current 250V AC 5 Amps

Direct Current: see table below

Body Stainless steel

Seals NBR, FPM, EPDM18.5 x 23.9 x 2mm15.5 x 1.5mm

Thread 1/2” BSP

Differential pressure setting 72 psi+-7 psi (5+-0.5 bar)

(other settings on request)

Electrical Standard DIN appliance plugScrewed cable gland PG 11Protection rating (DIN 40050) IP65Both NO and NC contacts areavailable in the switchRated capacity: see chart below

Visual contamination indicators are available in the following configurations:

Manual reset The indicator continues to display con-tamination even through the ∆p mayhave fallen. Pressing the plastic coverdown will reset the indicator.

Automatic reset The contamination signal will disappearwhen the ∆p drops below the setting for the indicator.

Note: Electrical and Visual-Electrical contaminationindicators are only available with automatic reset.

TECHNICAL SPECIFICATION

Note: High voltage peaks occurwhen inductive loads are switchedoff. Protective circuitry should beemployed to reduce contact burnout.

SEALING MATERIALB NBR - Buna -NV FPM - VitonE EPDM

HI - P T - 220 B

ORDERING INFORMATION

VOLTAGE (ONLY FOR CODE P)12 12V

24 24V110 110V220 220V

CODE EXECUTIONO PLUGA VISUAL, AUTOMATIC RESETV VISUAL, MANUAL RESETE ELECTRICALP VISUAL ELECTRICAL

THERMOSTOPWITHOUT THERMOSTOP

T WITH THERMOSTOP

88

PRODUCT TYPEHI Contamination Indicator

Page 5: Filters Pressure SF - RF

CONNECTION G

PRESSURE FILTERS SF SERIES

FIL

TR

AT

ION

3/00

DIMENSIONS

Threaded connection

Mounting Hole DimensionsCODE 61 FLANGE CONNECTION

b2 b3 G3

G3

Flange connectionCode 62

d1

b1

h4h1

h3

G

h2

SW

d 2

b2

b3

89

SF014/30 7/8 ” 22.2 17/8 ” 46.6 3/8 ”-16

SF045/70 13/16” 30.2 25/16” 58.7 7/16”-14

SF090/100 113/32” 35.6 23/4” 69.8 1/2 ”-13

b3

b2

G3

Note: Mounting holes match Code 62 connection for that size

DIMENSIONS PRESSURE FILTERS

FILTER

STANDARDb1 b2 b3 d1 d2 h1 h2 h3 h4 g3 SW

WEIGHTTHREADED SAE INCLUDING

SIZECONNECTION FLANGE ELEMENT

NPT SAE O-RING CODE 62 inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inches inch mm lbs kgs

SF0143/4" 1 1/16"-12 3/4" 4.09 104 0.94 23.8 2.0 50.8 2.68 68 3.27 83

7.4 188 3.07 781.89

SF030 10.0 254 5.67 144

SF0451 1/4" 1 5/8"-12 1 1/4" 5.51 140 1.24 31.6 2.63 66.7 3.74 95 4.57 116

9.4 240 4.06 1031.95

SF070 11.7 298 6.34 161

SF0901 1/2" 1 7/8"-12 1 1/2" 7.01 178 1.44 36.7 3.13 79.4 5.12 130 6.26 159

12.7 323 5.83 1482.83

SF160 19.5 495 12.56 319

483⁄8" - 16

1.06 2711 5

UNC 13 6

49.5 0.49 12.51⁄2" - 13

1.06 2726 12

UNC 28 13

725⁄8" - 11

1.42 3665 29.5

UNC 81 37

Page 6: Filters Pressure SF - RF

PRESSURE FILTERS SF SERIES

FIL

TR

AT

ION

3/00

SF 014 G10 V – T B / B P T 220

SE 014 G 10 V

Filter type SF

GROUP

SIZENOMINAL FLOW*

L/MIN GPM014 60 14030 110 30045 160 45070 240 70090 330 90160 660 160

VOLTAGE (ONLY FOR CODE P)12 12 V24 24 V110 110 V220 220 V

THERMOSTOP0 without ThermostopT with Thermostop

CONTAMINATION INDICATORO without contamination indic.A visual, with autom. resetV visual, with manual resetE electricalP visual/electrical

VALVEO without valveB Bypass valveR Reverse flow valveN Non return valveM Multi-function valve

ORDERING CODE FILTER HOUSINGS

ORDERING CODE FILTER ELEMENTS

SERIES SE

FOR COMPLETE FILTERS:

identification filter material+ micron rating code(see ordering code filter elements below)

GROUP

according to filter housing

SEAL MATERIAL

B NBR - Buna-NV FPM - VitonE EPDM

other seal materials on request

MOUNTING STYLE

T – In Line (straight)

PORT STYLE GROUP

CODE CONNECTION STYLE 014 030 045 070 090 160

N NPT 3⁄4” 11⁄4” 11⁄2”U SAE-“O“-Ring thread 11⁄16 – 12 UNF 15⁄8 – 12 UNF 17⁄8 – 12 UNF

G SAE-flange 3⁄4” 11⁄4” 11⁄2”(6000 psi)

F SAE-flange 3⁄4” 11⁄4” 11⁄2”(3000 psi)

B BSP G 3⁄4” G 11⁄4” G 11⁄2”other port connections on request

FILTER MATERIAL

Code Material ∆p maxA Stainless fiber 3000 psi (210 bar)C Polyester fiber 3000 psi (210 bar)N, D Paper 430 psi (30 bar)G, E Inorganic glass fiber 430 psi (30 bar)H, F Inorganic glass fiber 3000 psi (210 bar)B, S Stainless mesh 430 psi (30 bar)T, W Stainless mesh 3000 psi (210 bar)

MICRON RATING

03 3 µm05 5 µm10 10 µm20 20 µm25 25 µm40 40 µm60 60 µm

100 100 µm

other micron ratings on request

SEAL MATERIAL

B NBR - Buna-NV FPM - VitonE EPDM

other seal materials on request

MICRON RATINGSAVAILABLE

03, 05,10, 20

25, 40,60, 100

Bold type identifies preferred material

90

*Note: Exact flow will depend on filterelement selected. Consult TechnicalData on pages 91, 92 & 93.

Page 7: Filters Pressure SF - RF

PRESSURE DROP/ FLOW CURVESFIL

TR

AT

ION

3/00

FLOW CHARACTERISTICS OF PRESSURE FILTERSThe following flow characteristics are valid for mineral oils with a specific gravity of 0.85 and the kinematicviscosity of 141 SSU (30 cSt). The characteristics have been determined in accordance to ISO 3968.

Housing Characteristics SFFilter Size

∆p

BarPsi1.6

0.0

1.4

1.2

1.0

0.8

0.6

0.4

0.2

23.5

0.0

20.5

17.5

14.5

12.0

9.0

6.0

3.0

0 10.5 21.0 31.5 GPMLPM

5.5 16.0 26.00 40 80 12020 60 100

Filtergehäuse Baugröße SF 045/0700.8

0.0

∆p

BarPsi

0 21.0 42.0 63.0 GPMLPM

Q

0.7

0.6

0.5

0.4

0.3

0.2

0.1

12.0

0.0

10.5

10.0

7.5

6.0

4.5

3.0

1.5

11.0 32.0 52.00 80 160 24040 120 200

Filtergehäuse Baugröße SF 090/160

1.0

0.8

0.6

0.4

0.2

0.0

∆p

BarPsi

0 26.0 52.0 78.0 104.0 130.0 156.0 GPM

LPM0 100 200 300 400 500 600Q

1.2

1.4

1.6

1.8

2.0

14.5

12.0

9.0

6.0

3.0

0.0

17.5

20.5

23.5

26.5

30.0

Bypass Valve Flow Characteristics(incl. housing resistance, without element)

Reverse Flow Valve

F16.0

0.0

14.0

12.0

10.0

8.0

6.0

4.0

2.0

235.0

0.00

203.0

174.0

145.0

116.0

87.0

58.0

29.0

0% 40% 80% 120%20% 60% 100%0% 10.5 21.0 31.5 GPM5.5 16.0 26.0

EBDA, C

BarPsi

4.0

0.0

∆p

Bar Psi

3.0

2.0

1.0

58.0

0.0

43.5

29.0

14.5

A

B

Filter Size SF 014: AFilter Size SF 030: BFilter Size SF 045: CFilter Size SF 070: DFilter Size SF 090: EFilter Size SF 160: F

Characteristics of themulti-function valve are approximately 5%higher than those ofthe bypass valve

A: Filter Size SF 030 / SF 070 / SF 160B: Filter Size SF 014 / SF 045 / SF 090

Characteristics of the multi-function valve areapproximately 15% higher than those of thebypass valve.

Filter Housing Size SF 014/030Bypass Valve

Flow Direction A —> B

Filter Housing Size SF 045/070

Filter Housing Size SF 090/160

91

4.0

0.0

Bar Psi

3.0

2.0

1.0

58.0

0.0

43.5

29.0

14.5

A

B

Flow Direction B —> A

Q

0% 20% 40% 60% 80% 100% 120%Q in gpm as a percentage of the filter size

0% 20% 40% 60% 80% 100% 120%Q in gpm as a percentage of the filter size

Q in gpm as a percentage of the filter size

Page 8: Filters Pressure SF - RF

PRESSURE DROP/ FLOW CURVESFIL

TR

AT

ION

3/00

ELEMENT FLOW CHARACTERISTICS

SE 014 A1.0

0.8

0.6

0.4

0.2

0.0

14.5

12.0

9.0

6.0

3.0

0.0

Bar Psi

03 µm

05 µm

10 µm

20 µm

0 3.0 5.5 8.0 10.5 13.0 16.0 GPM

LPM0 10 20 30 40 50 60

Q

SE 014 C4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 5.5 10.5 16.0 GPMLPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

3.0 8.0 13.00 20 40 6010 30 50

SE 014 G4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 5.5 10.5 16.0 GPMLPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

3.0 8.0 13.00 20 40 6010 30 50

SE 014 H4.0

0.0

Bar 03 µm

05 µm

10 µm

20 µm

0 5.5 10.5 16.0 GPM LPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

3.0 8.0 13.0

0 20 40 6010 30 50

SE 030 A1.0

0.8

0.6

0.4

0.2

0.0

Bar14.5

12.0

9.0

6.0

3.0

0.0

Psi

03 µm

05 µm

10 µm

20 µm

0 5.5 10.5 16.0 21.0 26.0 31.5 GPMLPM0 20 40 60 80 100 120

Q

SE 030 C4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 10.5 21.0 31.5 GPMLPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

5.5 16.0 26.00 40 80 12020 60 100

SE 030 G4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 10.5 21.0 31.5 GPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

5.5 16.0 26.00 40 80 120 LPM20 60 100

SE 030 H4.0

0.0

Bar 03 µm

05 µm

10 µm

20 µm

0 10.5 21.0 31.5 GPMLPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

5.5 16.5 26.00 40 80 12020 60 100

SE 045 A1.0

0.8

0.6

0.4

0.2

0.0

Bar14.5

12.0

9.0

6.0

3.0

0.0

Psi

03 µm

05 µm

10 µm

20 µm

0 5.5

Q

10.5 16.0 21.0 26.0 31.5 36.5 42.0 GPMLPM0 20 40 60 80 100 120 140 160

SE 045 C4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 5.5

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

10.5 16.0 21.0 26.0 31.5 36.5 42.0 GPMLPM0 20 40 60 80 100 120 140 160

SE 045 G4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 5.5

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

10.5 16.0 21.0 26.0 31.5 36.5 42.0 GPMLPM0 20 40 60 80 100 120 140 160

SE 045 H4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 5.5

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

10.5 16.0 21.0 26.0 31.5 36.5 42.0 GPM0 20 40 60 80 100 120 140 160 LPM

92

Page 9: Filters Pressure SF - RF

PRESSURE DROP/ FLOW CURVESFIL

TR

AT

ION

3/00

ELEMENT FLOW CHARACTERISTICS

SE 070 A1.0

0.8

0.6

0.4

0.2

0.0

Bar14.5

12.0

9.0

6.0

3.0

0.0

Psi

03 µm

05 µm

10 µm

20 µm

0 10.5 21.0 31.5 42.0 52.0 62.5 GPM

LPM0 40 80 120 160 200 240Q

SE 070 C4.0

0.0

Bar

03 µm05 µm

10 µm20 µm

0 21.0 42.0 62.5 GPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

10.5 31.5 52.00 80 160 240 LPM40 120 200

SE 070 G4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 21.0 42.0 62.5 GPM

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

10.5 31.5 52.0

0 80 160 240 LPM

Q40 120 200

SE ... B0.10

0.08

0.06

0.04

0.02

0.00

Bar

1.5

1.2

.9

.6

.3

.0

Psi

25 µm

40 µm

60 µm

SE 090 A1.0

0.8

0.6

0.4

0.2

0.0

Bar

14.5

12.0

9.0

6.0

3.0

0.0

Psi

03 µm

05 µm

10 µm

20 µm

0 29.0 57.5 86.0 GPM0 110 220 330 LPM

Q

SE 090 C4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 29.0 57.5 86.0 GPM

0 110 220 330 LPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

SE 090 G4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 29.0 57.5 86.0 GPM0 110 220 330 LPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

SE ... D0.5

0.4

0.3

0.2

0.1

0.0

Bar

7.5

6.0

4.5

3.0

1.5

0.0

Psi

10 µm

20 µm

SE 160 A1.0

0.8

0.6

0.4

0.2

0.0

Bar

14.5

12.0

9.0

6.0

3.0

0.0

Psi

03 µm

05 µm

10 µm

20 µm

0 55.0 109.5 164.0 GPM0 210 420 630 LPM

Q

SE 160 C4.0

0.0

Bar

03 µm

05 µm10 µm

20 µm

0 55.0 109.5 164.0 GPM0 210 420 630 LPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

SE 160 G4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 55.0 109.5 164.0 GPM0 210 420 630 LPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

SE 070 H4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 21.0 42.0 62.5 GPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

10.5 31.5 52.0

0 80 160 240 LPM40 120 200

SE 090 H4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 29.0 57.5 86.0 GPM

0 110 220 330 LPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

SE 160 H4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 55.0 109.5 164.0 GPM0 210 420 630 LPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

Pressure Filter Elementswith Filter Material “B“

Pressure Filter Elementswith Filter Material “D“

93

0% 20% 40% 60% 80% 100% 120%Q in gpm as a percentage of the nominal flow

0% 20% 40% 60% 80% 100% 120%Q in gpm as a percentage of the nominal flow

Page 10: Filters Pressure SF - RF

RETURN LINE FILTERSRF SERIES

FIL

TR

AT

ION

3/00

TECHNICAL DATASTAUFF RF return line filters are designed as tank top filters. They are mounted directly on the tank top andif 100% of the system oil is filtered, they provide the optimum removal of contaminant from the system.This provides the pump with clean oil thus reducing contaminant generated wear. The filter bowl is designedto return oil beneath the tank oil surface thus preventing the entrainment of air by the returning oil.

TECHNICAL SPECIFICATIONS/OPTIONS

Construction – Tank Top flange mounting

Filter head – Aluminum

Filter bowl – Steel

Seals – NBR Buna-N, FPM (Viton) or EPDM (Ethylene-Propylene)

Threaded – NPT- and connection – SAE-“O“-Ring thread

– SAE-flange (3000 psi)

Max. Operating press. – 230 psi (16 bar)

Proof pressure – 350 psi (24 bar)

Temperature Range – -10°C up to +100°C14°F to 212°

Bypass valve – Opening pressure (integrated in the 43 psi ± 4 psi (3 bar ± 0.3 bar) filter element) – Other pressures available on request

Contamination – Gauge indicator 0-58 psi indicator (0-4 bar) with colored segments

– Electrical switch, setting 36 psi (2.5 bar)

Filter elements – Filter material specification A, B, G, S:Collapse rating per ISO 2941 430 psi (30 bar) ∆p

– Filter material specification D, N:Collapse rating per ISO 2941 230 psi (16 bar) ∆p

Media – Mineral oils – Other fluids on request

Contamination Indicator

(optional)

Housing Cover

Filter Head

Flange Seal

Filter Element with

integrated Bypass Valve

Filter Bowl

Outlet

94

Page 11: Filters Pressure SF - RF

RETURN LINE FILTERSRF SERIES

FIL

TR

AT

ION

3/00

OPTIONS1. Visual contamination indicator

The gauge displays the degree of contamination of the element. The coloredsegments allow quick visual checking.green 0 -36 psi (0.0-2.5 bar) Element has service life leftyellow 36-43 psi (2.5-3.0 bar) Element is contaminated and

should be changed red >43 psi (>3.0 bar) Bypass valve open, unfiltered oil

passing to tankThe contamination indicator can be mounted on the top or on the side of the filter head (see drawing on page 96).

2. Electrical contamination switch

The switch is used where an electrical signal is needed to indicatewhen the element needs changing. The switch can turn on a light,or shut the machine down, or any other function controlled by anelectric signal. The switching pressure is 36 psi (2.5 bar) and this allows the element to be changed before the bypass setting of 43 psi (3.0 bar) is reached.

Maximum Voltage Switch Type24 V G 24V

110 V G 110220 V G 220

3. Leakage oil connection

Seal or case drain lines can be connected to the filter througheither of the contamination indicator ports providing that the leakage oil can accept a pressure of 43 psi (3.0 bar.) It ensures that no un-filtered oil returns to the reservoir.

4. Filter bowl with threaded connection

Under some circumstances such as a tall reservoir or one withoil levels which vary greatly during operation, it is necessary toextend the filter bowl so that the returning oil returns beneath thesurface and no air enters during the process. The optional bowlwith a female thread allows an extension to be fitted quite simply.

95

Visual contamination indicator

Electrical contamination switch

Leakage oil connection

Threaded outlet

Page 12: Filters Pressure SF - RF

RETURN LINE FILTERS RF SERIES

FIL

TR

AT

ION

3/00

DIMENSIONS

DIMENSIONS RETURN LINE FILTERS

d1

d2

d3

h4

h3h1

h2

G

h5

Ausb

aum

a ß

für

h

6

f

l1

b1 s

quar

e

b2 s

quar

e

b4

b3 b5

b6

G3

G2

h5

d4

d5

G4

POSITION 1

Standard position forcontamination indicator1.8” NPT

POSITION 2

CODE 61 SAE FLANGE CONNECTION(NOTE: CHECK CLEARANCE FROM TANK)

MOUNTING DETAIL

THREADED OUTLET

ELEM

ENT

REM

OVA

L C

LEA

RA

NC

E

96

DimensionsFilterSize

NPT SAE-“O“ SAE-Ring flange b1 b2 b3 b4 b5 b6 d1 d2 d3 d4 d5 h1 h2

G Port

RF 014 3/4” 11/16”-12 UNF – mm. 89 80 – – – – 73 60 22 100 78 33 66

RF 030 1” 15/16”-12 UNF – in. 3.50 3.15 – – – – 2.87 2.36 0.87 3.94 3.07 1.3 2.6

RF 045 11/4” 15/8”-12 UNF – mm. 120 110 – – – – 100 87 34 135 105 41 86

RF 070 11/2” 17/8”-12 UNF – in. 4.72 4.33 – – – – 3.94 3.43 1.34 5.31 4.13 1.61 3.39

RF 090 2” 17/8”-12 UNF 2” mm. 150 135 88 102 42.9 77.8 126 113 48.3 170 131 47 98

RF 130 2” 17/8”-12 UNF 2” in. 5.91 5.31 3.46 4.02 1.69 3.06 4.96 4.45 1.90 6.69 5.16 1.85 3.86

Wt.h3 h4 h5 h6 l1 G2 G3 G4 lbs. kg.

94 155 1401/4”3.70 6.10 30 5.51 48

161.5 222.5 1.2 210 1.89 UNC6.36 8.76 8.27121 207 180

5/16”4.76 8.15 25 7.09 66179 265 1.0 240 2.67.05 10.43 9.45

UNC

173 271 2351/2” 3/8”6.81 10.67 34 9.25 85UNC UNC255 353 1.3 315 3.35

10.04 13.90 12.40

1”NPT

2”NPT

11/2”NPT

2.0 .9

2.40 1.09

4.55 2.06

5.10 2.30

8.45 3.80

9.50 4.30

Page 13: Filters Pressure SF - RF

RETURN LINE FILTERS RF SERIES

FIL

TR

AT

ION

3/00

RF 090 G10 B / N M2 L1

RE 090 G 10 B

CONTAMINATION INDICATORPos.*

M Pressure gaugeG 24 Electrical switch 24 V

1 2G 110 Electrical switch 110 VG 220 Electrical switch 220 V

* position of contamination indicator see page 96without any code: assembly in the middle of the filter cover

ADDITIONAL FEATURES Pos.*

L Drain line connection 1 2

G Threaded outlet

* position of leakage oil connection see page 96without any code: assembly in the middle of the filter cover

ORDERING CODE FILTER HOUSINGS

ORDERING CODE FILTER ELEMENTS

SERIES RE

GROUP

according to filter housing

CONNECTION STYLE GROUP

Code Connection style 014 030 045 070 090 130

N NPT 3/4” 1” 11/4” 11/2” 2” 2”N 1 NPT 1” 3/4” 11/2” 11/4” 11/2” 11/2”U SAE-“O“-Ring thread 11/16” 15/16” 15/8” 17/8” 17/8” 17/8”U 1 SAE-“O“-Ring thread 15/16” 11/16” 17/8” 15/8” 15/8” 15/8”

F SAE-flange – – – – 2” 2”(3000 psi)

Filter material

Code Material ∆p maxA Stainless fiber 430 psi (30 bar)N, D Paper 230 psi (16 bar)G, E Inorganic glass fiber 430 psi (30 bar)S, B Stainless mesh 430 psi (30 bar)

Filter type RF

Group

SIZENOMINAL FLOW*

L/MIN GPM014 60 14030 110 30045 160 45070 240 70090 330 90130 500 130

FOR COMPLETE FILTERS:

identification filter material+ micron rating code

(see ordering code filter elements below)

SEAL MATERIAL

B NBR - Buna-NV FPM - VitonE EPDM

other seal material on request

Micron rating

03 3 µm05 5 µm10 10 µm20 20 µm25 25 µm40 40 µm60 60 µm

100 100 µm

other micron ratings on request

Seal material

B NBR - Buna-NV FPM - VitonE EPDM

other seal materials on request

Micron ratingsavailable

03, 05,10, 20

25, 40, 60, 100Bold type identifies preferred material.

97

Note: Exact flow will depend on filterelement selected. Consult TechnicalData on page 98 and 99.

Page 14: Filters Pressure SF - RF

PRESSURE DROP/ FLOW CURVESFIL

TR

AT

ION

3/00

FLOW CHARACTERISTICS OF RETURN LINE FILTERSThe following flow characteristics are valid for mineral oils with a specific gravity of 0.85 and the kinematicviscosity of 141 SSU (30 cSt). The characteristics have been determined in accordance to ISO 3968.

RE 014 A0.5

0.4

0.3

0.2

0.1

0.0

Bar

7.5

6.0

4.5

3.0

1.5

0.0

Psi

10 µm

20 µm

0 3.0 5.5 8.0 10.5 13.0 16.0 GPM0 10 20 30 40 50 60

QLPM

RE 014 G4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 5.5 10.5 16.0 GPM

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

3.0 8.0 13.0

0 20 40 60

Q10 30 50 LPM

RE 014 N0.10

0.08

0.06

0.04

0.02

0.00

Bar

1.5

1.2

.9

.6

.3

0.0

Psi

10 µm

20 µm

0 3.0 5.5 8.0 10.5 13.0 16.0 GPM0 10 20 30 40 50 60

QLPM

RE 030 A0.5

0.4

0.3

0.2

0.1

0.0

Bar

7.5

6.0

4.5

3.0

1.5

0.0

Psi

10 µm

20 µm

0 5.5 10.5 16.0 21.0 26.0 32.0 GPM0 20 40 60 80 100 120

QLPM

RE 030 G4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 10.5 21.0 32.0 GPM

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

5.5 16.0 26.00 40 80 120

Q20 60 100 LPM

RE 030 N0.10

0.08

0.06

0.04

0.02

0.00

Bar

1.5

1.2

.9

.6

.3

0.0

Psi

10 µm

20 µm

0 5.5 10.5 16.0 21.0 26.0 32.0 GPM0 20 40 60 80 100 120

QLPM

RE 045 A0.5

0.4

0.3

0.2

0.1

0.0

Bar

7.5

6.0

4.5

3.0

1.5

0.0

Psi

10 µm

20 µm

0 5.5 10.5 16.0 21.0 26.0 32.0 37.0 42.0 GPM0 20

Q40 60 80 100 120 140 160 LPM

RE 045 G4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 5.5

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

10.5 16.0 21.0 26.0 32.0 37.0 42.0 GPM0 20

Q40 60 80 100 120 140 160 LPM

RE 045 N0.10

0.08

0.06

0.04

0.02

0.00

1.5

1.2

.9

.6

.3

0.0

BarPsi

10 µm

20 µm

0 5.5 10.5 16.0 21.0 26.0 32.0 37.0 42.0 GPM0 20

Q40 60 80 100 120 140 160 LPM

RE 014 S0.10

0.08

0.06

0.04

0.02

0.00

Bar

1.5

1.2

.9

.6

.3

0.0

Psi

25 µm

40 µm

0 3.0 5.5 8.0 10.5 13.0 16.0 GPM0 10 20 30 40 50 60

Q

60 µm

100 µm

LPM

RE 030 S0.10

0.08

0.06

0.04

0.02

0.00

Bar

1.5

1.2

.9

.6

.3

0.0

Psi

40 µm

25 µm

0 5.5 10.5 16.0 21.0 26.0 32.0 GPM0 20 40 60 80 100 120

Q

60 µm

100 µm

LPM

RE 045 S0.10

0.08

0.06

0.04

0.02

0.00

Bar

1.5

1.2

.9

.6

.3

0.0

Psi

25 µm

100 µm

0 5.5 10.5 16.0 21.0 26.0 32.0 37.0 42.0 GPM0 20

Q40 60 80 100 120 140 160 LPM

40 µm

60 µm

Filtergehäuse Baugröße RF 014/0300.40

0.00

Bar

0 10.5 21.0 32.0 GPM

0.30

0.20

0.10

6.0

0.0

Psi

4.5

3.0

1.5

5.5 16.0 26.0 0 40 80 120 LPM

Q20 60 100

Filtergehäuse Baugröße RF 045/0700.40

0.00

Bar

0 21.0 42.0 62.5 GPM

0.30

0.20

0.10

6.0

0.0

Psi

4.5

3.0

1.5

10.5 32.0 52.0

0 80 160 240 LPM

Q

40 120 200

Filtergehäuse Baugröße RF 090/1300.40

0.00

Bar

0 130 GPM

0.30

0.20

0.10

6.0

0.0

Psi

4.5

3.0

1.5

104.078.052.026.0

0 500 LPM

Q

400300200100

ELEMENT FLOW CHARACTERISTICS

Housing Filter Size RF 014/030 Housing Filter Size RF 045/070 Housing Filter Size RF 090/130

98

Page 15: Filters Pressure SF - RF

PRESSURE DROP/ FLOW CURVESFIL

TR

AT

ION

3/00

ELEMENT FLOW CHARACTERISTICS

RE 070 A0.5

0.4

0.3

0.2

0.1

0.0

Bar

7.5

6.0

4.5

3.0

1.5

0.0

Psi

10 µm

20 µm

0 10.5 21.0 32.0 42.0 52.0 62.5 GPM0 40 80 120 160 200 240 LPM

Q

RE 070 G4.0

0.0

Bar

03 µm

05 µm

10 µm20 µm

0 21.0 42.0 62.5 GPM

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

10.5 32.0 52.00 80 160 240 LPM

Q40 120 200

RE 070 N0.10

0.08

0.06

0.04

0.02

0.00

Bar

1.5

1.2

.9

.6

.3

.0

Psi

10 µm

20 µm

0 10.5 21.0 32.0 42.0 52.0 62.5 GPM0 40 80 120 160 200 240 LPM

Q

RE 070 S0.10

0.08

0.06

0.04

0.02

0.00

Bar

1.5

1.2

.9

.6

.3

.0

Psi

40 µm

25 µm

0 10.5 21.0 32.0 42.0 52.0 62.5 GPM0 40 80 120 160 200 240 LPM

Q

60 µm

100 µm

RE 090 A0.5

0.4

0.3

0.2

0.1

0.0

Bar

7.5

6.0

4.5

3.0

1.5

0.0

Psi

10 µm

20 µm

0 29.0 58.0 86.0 GPM0 110 220 330 LPM

Q

RE 090 G4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 29.0 58.0 86.0 GPM

0 110 220 330 LPM

Q

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

RE 090 N0.10

0.08

0.06

0.04

0.02

0.00

Bar

1.5

1.2

.9

.6

.3

.0

Psi

10 µm

20 µm

0 29.0 58.0 86.0 GPM0 110 220 330 LPM

Q

RE 090 S0.10

0.08

0.06

0.04

0.02

0.00

Bar

1.5

1.2

.9

.6

.3

.0

Psi

25 µm

40 µm

0 29.0 58.0 86.0 GPM0 110 220 330 LPM

Q

60 µm

100 µm

RE 130 A0.5

0.4

0.3

0.2

0.1

0.0

Bar

7.5

6.0

4.5

3.0

1.5

0.0

Psi

10 µm

20 µm

0 26.0 52.0 78.0 104.0 130.0 GPM0 100 200 300 400 500 LPM

Q

RE 130 G4.0

0.0

Bar

03 µm

05 µm

10 µm

20 µm

0 26.0 104.0 130.0 GPM

3.5

3.0

2.5

2.0

1.5

1.0

0.5

58.0

0.0

Psi

51.0

43.5

36.5

29.0

22.0

14.5

7.5

78.052.00 100 400 500 LPM

Q300200

RE 130 N0.10

0.08

0.06

0.04

0.02

0.00

Bar

1.5

1.2

.9

.6

.3

.0

Psi

10 µm

20 µm

0 26.0 52.0 78.0 104.0 130.0 GPM

0 100 200 300 400 500 LPM

Q

RE 130 S0.10

0.08

0.06

0.04

0.02

0.00

Bar

1.5

1.2

.9

.6

.3

.0

Psi

0 26.0 52.0 78.0 104.0 130.0 GPM0 100 200 300 400 500 LPM

Q

25 µm

100 µm

40 µm

60 µm

99

Page 16: Filters Pressure SF - RF

RETURN LINE FILTERS RTF 10/25 SERIES

FIL

TR

AT

ION

3/00

100

SPECIFICATIONS• Flows to 25 gpm

• Working Pressure

RTF10–50 psi (3.4 bar)

RTF 25–100 psi (6.9 bar)

• For use with mineral and

petroleum based fluids only

• By-Pass in element 25 psi (1.6 bar)

• Operating temperature

-13oF to 212oF

-25oC to 100oC

• Aluminum die casting

• Buna-N seals

OPTIONS• For RTF25 series

• 10 or 25 micron paper elements

10 micron inorganic fiberß10>_75

• For RTF10 series, 20µm paper

element available only

• Visual and Electrical indicators

• Two bowl lengths for RTF25

• Special threads/special bowl

lengths/special elements

available on request

DIMENSIONS

TYPE INLET PORT BOWL A B C D E F G H I JWeight

LENGTH lbs. kgs.

RTF 10 1/2” NPT S1in 3.2 5.08 2.6 0.3 1.02 0.94 0.83 1.97 0.28 3.54 1.0 0.45

mm 82 129 66 8 26 24 21 50 7 90

RTF 25 1” NPT or S1 3.6 92 6.1 155 3.4 86 0.4 10 1.34 34 1.1 1.14 2.63 0.35 4.52 2.0 0.91 5/16” SAE S2 5.4 137 7.9 200 86 10 34 28 29 67 9 115 2.2 1.0

inmmin

mm

Page 17: Filters Pressure SF - RF

RETURN LINE FILTERS RTF 10/25 SERIES

FIL

TR

AT

ION

3/00

RTF 25N xxx B S2 V

ORDERING INFORMATION

FILTER TYPERTF

INDICATORN NoneV CI-20 Visual IndicatorE EPS-1 Electrical Indicator

BOWL LENGTHS1 Bowl length 1S2 Bowl length 2

SEAL MATERIALB Buna-N

PORT SIZE10N 1⁄2" NPT25N 1" NPT25S 15⁄16"-12 SAE

ORDERING CODE - FILTER ELEMENTSRTE10 D 20 B / S1 20 Micron nominal paperRTE25 D 10 B / S1 10 Micron nominal paper / S1 bowl lengthRTE25 D 10 B / S2 10 Micron nominal paper / S2 bowl lengthRTE25 D 25 B / S2 25 Micron nominal paper / S2 bowl lengthRTE25 G 10 B / S2 10 Micron (ß10 ≥,75) Inorganic fiber / S2 bowl length

0

1/2"1"

20

0.5

0.4 6.0

PSI

gpm

4.5

3.0

1.5

0.3

0.2

0.1

40 60 80 1000 75lpm 150 225 300 375

FILTER HEAD – RTF 10/25 SERIES

PRES

SUR

E D

RO

P (B

AR

)

FLOW

0 20

0.5

0.4 6.0

4.5

3.0

1.5

0.3

0.2

0.1

40 60 80 100

0 5 10 15 20 25

FILTER ELEMENTS–RTF 10 SERIES

PRES

SUR

E D

RO

P B

AR

20 MICRON

gpmlpm

FLOW

PSI

0 40 80 120 160 200

0 5 10 15 20 25

0.5

0.4 6.0

4.5

3.0

1.5

0.3

0.2

0.1

PRES

SUR

E D

RO

P B

AR

10µ inorga

nic

10 micron paper

25 micron paper

FILTER ELEMENTS–RTF 25 SERIES

gpmlpm

FLOW

PSI

PRESSURE DROP RTF 10/25

See page 136 for more details on the Indicator options.

All curves on 141 SSU (30 cts) viscosity oil @ 100°F

101

µm

10µm in

organ

ic fi

ber

10µm paper

25µm paper

Page 18: Filters Pressure SF - RF

RETURN LINE FILTERS RTF 47 SERIES

FIL

TR

AT

ION

3/00

102

SPECIFICATIONS• Flows to 55 gpm

• Working Pressure 100 psi (6.9 bar)

• For use with mineral and petroleum

based fluids only

• By-Pass in element 25 psi (1.6 bar)

• Operating temperature

-13oF to 212oF

-25oC to 100oC

• Aluminum die casting

• Buna-N seals

• 1 1⁄4” NPT / 1 1⁄2” SAE 4 bolt flange part

OPTIONS• Elements

-10 micron paper ß10 >_ 2

-10 micron inorganic fiber ß10 >_ 75

• Special threads and bowl length available on request.

DIMENSIONS

A B C D E F G H WEIGHT

IN 9.3 11.9 4.4 0.45 1.9 1.6 1.9 6.7 5.9 Lbs

MM 236 302 112 11.4 48 41 48 170 2.6 kg

Page 19: Filters Pressure SF - RF

RETURN LINE FILTERS RTF 47 SERIES

FIL

TR

AT

ION

3/00

RTF 47N xxx B S1 V

ORDERING INFORMATION

FILTER TYPERTF

INDICATORN NoneV CI-20 Visual IndicatorE EPS-1 Electrical Indicator

BOWL LENGTHS1 Bowl length 1

SEAL MATERIALB Buna-N

PORT SIZE47N 1 1/4" NPT / 1 1/2”SAE FLANGE

ORDERING CODE - FILTER ELEMENTSRTE47 D 10 B / S1 10 Micron nominal paper, (ß10 ≥ 2) S1 bowl lengthRTE47 G 10 B / S1 10 Micron Inorganic fiber, (ß10 ≥ 75) S1 bowl length

0 40

0.5

0.4 6.0

psi

Flow gpm

4.5

3.0

1.5

0.3

0.2

0.1

80 1200 150lpm 300 450

RTF 47 FILTER HEAD

PRES

SUR

E D

RO

P B

AR

1 1/4" NPT / 1 1/2" FLANGE

Flow gpm

0 75 150 225 300lpm0 20 40 60 80

RTF 47 FILTER ELEMENTS 0.5

0.4 6.0

4.5

3.0

1.5

0.3

0.2

0.1

PRES

SUR

E D

RO

P B

AR

10µ in

organ

ic

10 micron paper

PRESSURE DROP/FLOW RTF 47 SERIES

See page 136 for more details on the Indicator options.

103

lpm lpm

psi

10µm

inor

gani

c fib

er

10µm paper

Page 20: Filters Pressure SF - RF

RETURN LINE FILTERSRTF 20 SERIES

FIL

TR

AT

ION

3/00

104

SPECIFICATIONS• Flows up to 30 gpm (110 lpm)

• Die-cast aluminum head with a

polyamid screw-on cap and bowl

• Combination filter, breather and filler

• Maximum working pressure 145 psi (10 bar)

• For use with mineral and petroleum

based fluids only

• By-pass in element 25 psi (1.6 bar)

• Operating Temperature -13°F to 212°F

-25°C to 100°C

• 10µ filler breather

• Buna - N Seals

• Filter Element Collapse rating 75psi (5 bar)

OPTIONS• 1⁄2” NPT, 3⁄4” NPT, -8 SAE, -12 SAE Ports

• Elements 10µ Paper

6µ inorganic glass fiber

10µ inorganic glass fiber

20µ inorganic glass fiber

• Electrical or Visual indicators available

• Dipstick Available

• 40µ paper breather element

• Special elements available on request

DIMENSIONAL INFORMATION

A B C D E F G H J K L M N P R

RF20 in 7.95 1.61 2.95 7.01 0.94 3⁄4” NPT 0.63 1.1 1.97 2.76 0.43 3.46 3.23 3.03

mm 202 41 75 178 24 or SAE 16 28 50 70 11 88 82 77

K LC

J

G

H

BA D

E

2F

M

R

PN

min 2.36”max 2.48”min 60mmmax 63mm

Page 21: Filters Pressure SF - RF

PRESSURE DROP / FLOW CURVES RTF 20 SERIES

FIL

TR

AT

ION

3/00

∆p 10µm 40µm

105

FLOW RATES FOR FILLER BREATHER CARTRIDGE FILTRATION AREA (cm2)

0.7 psi gpm 30.0 42

0.05 bar lpm 114 160

1.4 psi gpm 50 66

0.10 psi lpm 190 250

RTF20 BETARATIO

10µm paper 870 B10 ≥ 2

6µm glass fiber 710 B6 ≥ 75

10µm glass fiber 710 B10 ≥ 75

20µm glass fiber 710 B20 ≥ 75

RTF 20 FILTER HEAD

VISCOSITY - 141 SSU (30 CS). TEMPERATURE - 100°F (38°C)

7.5 0.5

40152

0.4

0.3

0.2

0.1

6.0

4.5

3.0

1.5

0 1038

2076

30114

FLOW

gpmlpm

RTF 20 FILTER ELEMENTS7.5 0.5

20114

0.4

0.3

0.2

0.1

6.0

4.5

3.0

1.5

0 519

1038

1576

FLOW

gpmlpm

PSI

PSI

BA

R

BA

R

DIRT HOLDING CAPACITY

ACFTD DHC (gms) ∆p = 1.3 BAR (19 psi)

6µm glass fiber 5

10µm glass fiber 6

20µm glass fiber 7

1/2” 3/4” 10µm paper

10µm

inor

gani

c fib

er

20µm in

orga

nic fib

er

6µm

inor

gani

c fib

er

Page 22: Filters Pressure SF - RF

ORDERING INFORMATION RTF 20 SERIES

FIL

TR

AT

ION

3/00

106

RTF20 N1 G 10 B V B 40 D

ORDERING INFORMATION-COMPLETE FILTER

FILTER TYPERTF 20

DIPSTICK- No DipstickD Dipstick

BREATHERB10 10 micronB40 40 micron

INDICATORN No IndicatorN1 No Indicator - Hole DrilledV Visual Indicator E EPS-1 Electrical Indicator

THREAD TYPEN1 1⁄2" NPTN2 3⁄4" NPTS1 3⁄4"- 16 SAES2 11⁄16"-12 SAE

RTE20 G 10 B

ORDERING CODE-FILTER ELEMENT

FILTER TYPERTE 20

SEALB Buna-NV Viton

MICRON RATING6 6 micron10 10 micron20 20 micron

FILTER MEDIAD PaperG Inorganic glass fiber

See page 136 for more details on the Indicator options.

Page 23: Filters Pressure SF - RF

RETURN LINE FILTERSRTF 30 SERIES

FIL

TR

AT

ION

3/00

107

SPECIFICATIONS• Flows up to 40 gpm (152 lpm)

• Die-cast aluminum head with a

polyamid screw-on cap and bowl

• Combination filter, breather and filler

• Maximum working pressure 145 psi (10 bar)

• For use with mineral and petroleum

based fluids only

• By-pass in element 25 psi (1.6 bar)

• Operating Temperature -13°F to 212°F

-25°C to 100°C

• 10µ filler breather

• Buna - N Seals

• Filter Element Collapse rating 75psi (5 bar)

OPTIONS• 3/4” NPT, 1” NPT, -12 SAE, -16 SAE Ports

• 3 Bowl lengths 4.33 in (110mm)

6.9 in (175mm)

10.8 in (275mm)

• 4 Elements 10µm paper

6µm inorganic fiber

10µm inorganic fiber

20µm inorganic fiber

• Electrical or Visual Indicators available

• Dipstick available

• 40µ paper filler breather element

• Special elements available on request.

DIMENSIONAL INFORMATION

AB

C

D

H

1.5

E

F

G

K L

M

N P

M

R

G

90°

J

Page 24: Filters Pressure SF - RF

PRESSURE DROP/ FLOW CURVESRTF 30 SERIES

FIL

TR

AT

ION

3/00

A B C D E F G H J K L M N P R

RTF30in 5.51 2.36 4.09 4.33 1.18 3/4” 0.87 1.42 2.76 3.27 0.43 4.53 4.33 4.06

mm 140 60 104 110 30 or 1” 22 36 70 83 11 115 110 103

RTF31in 8.07 2.36 4.09 6.89 1.18 3/4”

min. 3.43”

0.87 1.42 2.76 3.27 0.43 4.53 4.33 4.06

mm 205 60 104 175 30 or 1”

max. 3.58”

22 36 70 83 11 115 110 103

RTF32 in 12.01 2.36 4.09 10.83 1.18 3/4”

min. 87mm

0.87 1.42 2.76 3.27 0.43 4.53 4.33 4.06

mm 305 60 104 275 30 or 1”

max. 91mm

22 36 70 83 11 115 110 103

RTF 30/31/32 FILTER HEAD

VISCOSITY - 141 SSU (30 CS). TEMPERATURE - 100°F (38°C).

7.5 0.5

40152

0.4

0.3

0.2

0.1

6.0

4.5

3.0

1.5

0 1038

2076

30114

FLOW

gpmlpm

PR

ESSU

RE D

RO

P

RTF 30/31/32 FILTER ELEMENTS - 10 MICRON PAPER7.5 0.5

40152

0.4

0.3

0.2

0.1

6.0

4.5

3.0

1.5

0 1038

2076

30114

FLOW

gpmlpm

PR

ESSU

RE D

RO

P

RTF 30/31/32 FILTER ELEMENTS - 6 MICRON GLASS FIBER7.5 0.5

40152

0.4

0.3

0.2

0.1

6.0

4.5

3.0

1.5

0 1038

2076

30114

FLOW

gpmlpm

PR

ESSU

RE D

RO

P

RTF 30/31/32 FILTER ELEMENTS - 10 MICRON GLASS FIBER7.5 0.5

40152

0.4

0.3

0.2

0.1

6.0

4.5

3.0

1.5

0 1038

2076

30114

FLOW

gpmlpm

PR

ESSU

RE D

RO

P

PSI

PSI

PSI

PSI

BA

RB

AR

RTF 30/31/32 FILTER ELEMENTS - 20 MICRON GLASS FIBER7.5 0.5

40152

0.4

0.3

0.2

0.1

6.0

4.5

3.0

1.5

0 1038

2076

30114

FLOW

gpmlpm

PR

ESSU

RE D

RO

P

PSI

BA

R

BA

RB

AR

108

RTF

30

RTF

30

RTF

30

RTF 3

0

RTF 31

RTF 32

RTF 31

RTF

31

RTF

31

RTF 32

RTF 3

2

RTF

32

3/4”

1”

Page 25: Filters Pressure SF - RF

ORDERING INFORMATIONRTF 30 SERIES

FIL

TR

AT

ION

3/00

109

FILTRATION AREA (CM2)

RTF 30 RTF31 RTF32 Beta Ratio

940 1500 1850 B10 ≥ 2

670 1020 1670 B6 ≥ 75

670 1020 1670 B10 ≥ 75

670 1020 1670 B20 ≥ 75

10µmpaper

6µm fiber

10µm fiber

20µm fiber

RTF31 N2 G 10 B V B 40 D

FILTER TYPERTF 30 Bowl length

4.33”RTF 31 Bowl length

6.89”RTF 32 Bowl length

10.83”

DIPSTICK- No DipstickD Dipstick

BREATHERB10 10 micronB40 40 micron

INDICATORN No IndicatorN1 No Indicator - Hole DrilledV Visual Indicator E EPS -1Electrical Indicator

THREAD TYPEN1 3⁄4” NPTN2 1" NPTS1 11⁄16-12 SAES2 15⁄16-12 SAE

RTE 31 G 10 B

SERIESRTE

SEALB Buna-NV Viton

MICRON RATING6 6 micron10 10 micron20 20 micron

FILTER GROUP30 Bowl Lengths 4.33”31 Bowl Lengths 6.9”32 Bowl Lengths 10.8”

FILTER MATERIALD Paper

G InorganicGlass fiber

ORDERING INFORMATION-COMPLETE FILTER

ORDERING CODE-FILTER ELEMENT

30.0 42.1

114 160

50.0 66

190 250

FLOW RATES FOR FILLER BREATHER CARTRIDGE

∆p 10µ 40µ

0.7psi

0.05bar

1.4psi

0.10bar

gpm

lpm

gpm

lpm

DIRT HOLDING CAPACITY

ACFTD DHC (gms) at ∆p = 1.3 BAR (19 psi)

RTF30 RTF31 RTF32

6µm glass fiber 5 7 11

10µm glass fiber 6 9 15

20µm glass fiber 7 11 17

See page 136 for more details on the Indicator options.

Page 26: Filters Pressure SF - RF

RETURN LINE FILTERSTEF 625 SERIES

FIL

TR

AT

ION

3/00

110

DIMENSIONS

TEF 625 10VG16 S P V

ORDERING INFORMATION

FILTER TYPETEF - IN TANK RETURN

CLOGGING INDICATORV VISUALE1 ELECTRICAL

SEAL MATERIALP Buna-NV Viton

NOMINAL FLOW625 625 LPM-165 GPM

ORDERING CODE - FILTER ELEMENTS01.E 631.3VG.16 S P 3 Micron inorganic fiber01.E 631.10VG.16 S P 10 Micron inorganic fiber01.E 631.25VG.16 S P 25 Micron inorganic fiber

SPECIFICATIONS• Flows to 165 gpm (625 lpm)

• 2” SAE Flange (3000 psi)

Port Connection

• Working Pressure 145 psi (10 bar)

• All elements are β200 rated

• By-Pass in filter element 29 psi (2 bar)

• Glass fiber reinforced polyamid bowl

• Normal operating temperature

-14oF to 176oF (-25oC to 80oC)

OPTIONS• 3, 10, 25 Micron glass fiber elements

• Stainless steel mesh available on

special request

• Buna-N or Viton Seals

• Visual and Electrical Indicators available

Page 27: Filters Pressure SF - RF

RETURN LINE FILTERSTEF 950 SERIES

FIL

TR

AT

ION

3/00

111

DIMENSIONS

SPECIFICATIONS• Flows to 250 gpm (950 lpm)

• 3” SAE Flange (3000 psi)

Port Connection

• Working Pressure 145 psi (10 bar)

• All elements are β200 rated

• Steel bowl

• By-Pass in filter element 29 psi (2 bar)

• Normal operating temperature

-14oF to 176oF (-25oC to 80oC)

OPTIONS• 3, 10, 25 Micron glass fiber elements

• Stainless steel mesh available on

special request

• Buna-N or Viton Seals

• Visual and Electrical Indicators available

TEF 951 10VG10 S P V

ORDERING INFORMATION

FILTER TYPETEF - IN TANK RETURN

SEAL MATERIALP Buna-NV Viton

NOMINAL FLOW950 950 LPM-250 GPM

ORDERING CODE - FILTER ELEMENTS01.E 950.3VG.10 S P 3 Micron inorganic fiber01.E 950.10VG.10 S P 10 Micron inorganic fiber01.E 950.25VG.10 S P 25 Micron inorganic fiber

CLOGGING INDICATORV VISUALE1 ELECTRICAL

Page 28: Filters Pressure SF - RF

FILTER ELEMENTSFIL

TR

AT

ION

3/00

REPLACEMENT FILTER ELEMENTS FOR SF AND RF SERIESSTAUFF replacement filter elements for SF and RF series filters are manufactured in the common filtermaterials such as stainless fiber, stainless mesh, polyester fiber, paper, and inorganic glass fiber.All replacement elements made by STAUFF comply with quality specifications in accordance withinternational standards.

SE 014 G 10 V

ORDERING CODE FILTER ELEMENTS

Series

SE for pressure filters SF

RE for return line filters RF

Group

according to filter housing

Filter material SE RE

Code Material ∆p max ∆p max

A Stainless fiber 3000 psi (210 bar) 430 psi (30 bar)C Polyester fiber 3000 psi (210 bar) –N, D Paper 430 psi (30 bar) 230 psi (16 bar)G, E Inorganic glass fiber 430 psi (30 bar) 430 psi (30 bar)H, F Inorganic glass fiber 3000 psi (210 bar) –B, S Stainless mesh 430 psi (30 bar) 430 psi (30 bar)T, W Stainless mesh 3000 psi (210 bar) –

Micron rating

03 3 µm05 5 µm10 10 µm20 20 µm25 25 µm40 40 µm60 60 µm

100 100 µm

other micron rating on request

Seal material

B NBR - Buna-NV FPM - VitonE EPDM

other seal materials on request

Bold type identifies preferred material

Micron ratingsavailable

03, 05,10, 20

25, 40, 60, 100

112

Page 29: Filters Pressure SF - RF

FILTER ELEMENTSFIL

TR

AT

ION

3/00

INTERCHANGE FILTER ELEMENTS STAUFF manufactures interchange filter elements for a wide range of filter manufacturers. They meet thetechnical requirements with regard to quality and dimensions and consequently can be used withconfidence in the installations.

Interchange filter elements are available to suithousings of the following manufacturers:

• Argo • Eppensteiner• Internormen • Hydac/Hycon• Mahle • Pall• Fairey • MP FiltriSpecial elements are available on request. Please consult factory.

Continuing research and development of filtermaterials used by STAUFF, and observance of strictQuality Assurance procedures together with therelevant international standards, ensures consistentlyhigh performance of our filter elements.

STAUFF manufacturing and stocking policies aredesigned to give our customers ready access to awide range of filter elements from one source.

Consult www.stauffusa.com for a complete interchange guide.

113

Page 30: Filters Pressure SF - RF

FILTER ELEMENTSFIL

TR

AT

ION

3/00

Metal fiber

Inorganic glass fiber

Stainless wire mesh

Polyester fiber

Paper

FILTER MATERIAL SPECIFICATIONS

Polyester fiber

Material specification C collapse/burst resistance as per ISO 2941:3000 psi (210 bar)

• 100% polyester fiber with fibers thermally bonded creatinga tearproof material with no electrostatic charging.

• Exceptional shear strength. • Depth filtration gives large dirt holding capacity with low flow

resistance.• Good chemical resistance. • High filtration efficiency even on small particle sizes.

Inorganic glass fiber

Material specification G, E collapse/burst resistance as per ISO 2941:430 psi (30 bar)

Material specification H, F collapse/burst resistance as per ISO 2941:3000 psi (210 bar)

• Non-woven glass fiber material with acrylic resin bond.• High dirt holding capacity. • High filtration efficiency, even on small particle sizes,

achieved by the depth filtration produced by the threedimensional labyrinth structure of the material.

• Excellent cost effectiveness.

Material specifications G and H are the updated high performance elementsand should be selected for new applications.

Stainless wire mesh

Material specification B, S collapse/burst resistance as per ISO 2941:430 psi (30 bar)

Material specification W, T collapse/burst resistance as per ISO 2941:3000 psi (210 bar)

• Woven stainless steel wire in 1.4301/1.4404 grade with a squaremesh or double milled twill lace weave.

• Low flow resistance. • Surface filtration. Excellent chemical and thermal resistance.

Paper

Material specification D, Ncollapse/burst resistance as per ISO 2941: 430 psi (30 bar) (Pressure filters)collapse/burst resistance as per ISO 2941: 230 psi (16 bar) (Return line filters)• Filter material made from impregnated cellulose paper. • Low cost design with good dirt holding capacity. • Not suitable for use with any water based fluids.

Stainless Metal fiber

Material specification Acollapse/burst resistance as per ISO 2941: 3000 psi (210 bar) (Pressure filters)collapse/burst resistance as per ISO 2941: 430 psi (30 bar) (Return line filters)• Sintered stainless metal fiber with a three dimensional labyrinth structure

for depth filtration. • Low flow resistance with a high dirt holding capacity.• Excellent chemical and thermal resistance.

114

Page 31: Filters Pressure SF - RF

FILTER ELEMENTSFIL

TR

AT

ION

3/00

Multi Pass Testing (Beta Ratio)The Beta Ratio (βx) is considered one of the most important criteria in assessing the capability of a filter to removecontaminant particles. This value is determined by means of the multi-pass test, according to ISO/DIN 4572.

Definition: The Beta Ratio is the ratio of the number of particles, greater than a given size, upstream of the filter to the number of particles, greater than the same size, downstream of the filter in the same sizefluid sample.

βx = Number of particles >xµm upstream (x = particle size)

Number of particles >xµm downstream

The Beta Ratio can be used to calculate the Filter Efficiency Rating by the following formula.

Ex = βx - 1 x 100 Ex = % efficiencyβx

Example for a given particle size of 10 µm

β10 = 9360 = 208 E10 = 208 - 1 x 100 = 99.52 %

45 208

NOTE: All STAUFF inorganic glass fiber filter elements have a Beta Ratio >200at their rated micron rating.

STAUFF FILTER ELEMENTS are tested according to• ISO 2943

Compatibility with hydraulic fluids

• ISO 3968Flow characteristics

• ISO/DIN 3724Flow fatigue characteristics

• ISO/DIN 4572Filter performance test (Multi-pass test)

• ISO 2942Proof of integrity and quality (Bubble point test)

• ISO 3723Verification of the end cap stress

• ISO 2941Collapse / burst pressure verification

β Ratio vs Efficiency

β Ratio Efficiency

1 02 50%20 95%50 98.00%75 98.67100 99.00%200 99.501.000 99.90%10.000 99.99%

Multi-pass-test stand

115

Page 32: Filters Pressure SF - RF

Choice of the optimum filter

In selecting the filter, the following informationmust be considered:

• maximum flow volume (Qmax) through the filterincluding surge flows

• kinematic viscosity (υ) of the fluid in SSUat cold start temperature and operatingtemperature

• micron rating (µm): see table

• filter material

The aim is to choose a filter whose totaldifferential pressure (∆p) is no greater than∆pmax = 14.5 psi (1.0 bar) for pressure filters or∆pmax = 7.5 psi (0.5 bar) for return line filters, in aclean state at the normal operating temperature.These values have been proven in practice to givethe optimum service life for the element.

The nominal flow volume of the filter is theobvious reference value for pre-selection and thisshould be larger than the flow to be filtered.

Qnom > Qmax

Calculations based on the filter data will verifywhether the pre-selected filter meets therequirements, at operating temperatures:

∆pmax < 14.5 psi (1.0 bar) (for pressure filter)∆pmax < 7 psi (0.5 bar) (for return line filter)

The total differential pressure is the sum of thedifferential pressure values of the empty housingand the filter element. They are calculated fromthe flow characteristics tables.

∆ptotal = ∆phous + ∆pelem

The flow characteristic tables are based on akinematic viscosity of 30 centistokes (141 SSU).For different viscosities, a correction factor (K)based on the following formula must be appliedto the figure calculated at 30 centistokes (141 SSU).

υ + υ141 141K =

2

The operating differential pressure is thencalculated by the following formula:

∆poperating = ∆pnom + K x ∆pelem

The filter size is suitable if the ∆poperating < ∆pmax.If the calculated ∆poperating is greater than ∆pmax,select the next larger filter size and re-calculateuntil a satisfactory solution is found.

The following two examples explain the procedure.

TECHNICAL APPENDIXFIL

TR

AT

ION

3/00

CHOICE OF FILTERS

Choice of a suitable micron rating

Generally, the type of components incorporated inthe hydraulic system will determine the micronrating required. It has been clearly demonstratedthat system components will operate reliably foryears if a specific minimum oil cleanlinessgrade is maintained. Frequently the choice will bedetermined by the most sensitive componentin the system.

a) Operating filter

The following chart is a general guide but the finalresult should be checked by oil analysis. Apart fromthe specific flow rate (gpm/in2 of filter area), otherfactors such as operating environment andcondition of seals and breathers can have an effecton the cleanliness grade which can actually beachieved.

Oil cleanliness Microngrade as per rating Area of ApplicationISO 4406

13/10 3 µm servo valve hydraulics16/13 5 µm proportional hydraulics18/15 10 µm standard hydraulics >100 bar19/16 20 µm standard hydraulics <100 bar

b) Protective filter

Occasionally, protective filters are fitteddownstream of major components, eg., the pump,to collect the debris in case of a catastrophicfailure. This avoids total stripping and flushing ofthe system. For economic reasons, protective filtersare normally one grade coarser than the operatingfilters since they do not significantly contribute tothe cleaning of the system and this extends filterservice intervals.

116

Page 33: Filters Pressure SF - RF

TECHNICAL APPENDIXFIL

TR

AT

ION

3/00

Example 1: Selection of a pressure filterSystem Information. A pressure filter with an inorganic glass fiber element is required immediately afterthe pump. The system has standard components and is operating at pressures up to 3000 PSI (200 bar).The filter shall be fitted with a bypass valve and a visual contamination indicator.Data given: Qmax = 45 gpm (170 lpm)

υoperating = 213 SSU (46 cSt)Micron rating 10 µm (see table on page 8&9)

First StepPre-selection: Size SF 070, Qnominal = 70 gpm > Qmax

Pressure drop values at viscosity of 141 SSU (30 cSt) from the flow characteristics:∆phous – = 3.6 psi (0.25 bar) (SF 070 –, see page 7)∆pelem – = 12 psi (0.8 bar) (SE 070 G 10 B, see page 9)

Determination of the correction factor (see page 9)centistokes 46 + 46 213 + 213

K =30 30 = 1.39 K =

141 141 = 1.39

2 2Determination of the actual pressure drop:

∆pactual= ∆phous + K · ∆pelem = 0.25 bar + 1.39 x 0.80 bar = 1.36 bar > ∆pmax = 1.0 bar3.62 psi + 1.39 x 11.6 psi = 19.7 psi > ∆pmax = 14.5 psi

Since the actual pressure drop is larger than the allowed pressure drop, a larger filter has to be chosen.Second StepSelection of the next larger filter size; SF 090, Qnominal = 90 gpm > Qmax

∆phous = 2.1 psi (0.15 bar) (SF 090 –, see page 7)∆pelem = 8.7 psi (0.6 bar) (SE 090 G 10 B, see page 9)

Actual pressure drop ∆pact = ∆phous + K · ∆pelem = 0.15 bar + 1.39 x 0.6 bar = 0.99 bar ≤ ∆pmax = 1.0 baror = 2.1 psi + 1.39 x 8.1 psi = 13.4 psi ≤ ∆pmax = 14.5 psi

In a clean state, this filter fulfills the requirements and is suitable for the application.The correct filter designation is: SF090G10BTB/BV

System Information. A return line filter with a paper element is required to clean the oil. No contamination indicator is required.N. B. If the system incorporates either accumulators or cylinders, the return flow can

dramatically exceed pump flow and the maximum surge flow should be the flow used to calculate the pressure drop through the filter.

Data given: Qmax = 24 gpm (90 lpm)υoperating = 150 SSU (32 cSt)Micron rating 20 µm (see table page 14)

First StepPre-selection: Size RF 030, Qnominal = 30 gpm > Qmax (29 gpm)Pressure drop values at viscosity of 141 SSU (30 cSt) from the flow characteristics:

∆phous = 4 psi (0.27 bar) (RF 030 –, page 14)∆pelem = 0.6 psi (0.04 bar) (RE 030 N 20 B, page 14)

Determination of the correction factor (see page 14)centistokes 32 + 32 150 + 150

K = 30 30 = 1.05 K = 141 141 = 1.052 2

Determination of the actual pressure drop:∆pactual = ∆phous + K · ∆pelem = 0.27 bar + 1.05 x 0.04 bar = 0.31 bar < ∆pmax = 0.5 bar

or = 4 psi + 1.05 x 0.6 psi = 4.6 psi ≤ ∆pmax = 7.5 psiIn a clean state, this filter fulfills the requirements and is suitable for the application. No furthercalculation is necessary.The correct filter designation is: RF030N20B/B

EXAMPLES OF CALCULATION

117

Consult factory for the Stauff Filter Specification and Sizing Diskette for both SF and RF filters.

SSU

SSU

Example 2: Selection of a return line filter