Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

33
Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting

Transcript of Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Page 1: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Field Water Chemistry Analysis•Equipment Care •Test Procedures•Results Interpretation •Data Reporting

Page 2: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Field Chemistry Tests

•pH•Dissolved Oxygen•Conductivity•Temperature

Some things are just best done in person.

Page 3: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Field Chemistry EquipmentLamotte Brand Testing KitsAlcohol or mineral spirit thermometers Conductivity/TDS Meters (calibrated) pH meters calibrated with 4-7-10 standard solutions

Other field testing equipment is usable ifcalibrated and documented.

Testing strips such as pH paper and “dip strips”are not accepted.

Page 4: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

How to count to 10The ability to differentiate colorHow to follow step by step instructionsThe ability to fill a bottle

What you need to know

Page 5: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Measuring pH

Page 6: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

pH testing kit

Page 7: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

14131211109876543210

pH-Good Between 6-9 Standard Units

Acid Range

Basic or Alkaline Range

Page 8: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Interpreting pH Results

Page 9: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Measuring Dissolved Oxygen

Page 10: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.
Page 11: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Dissolved Oxygen testing kit

Page 12: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.
Page 13: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.
Page 14: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

1514131211109876543210

Dissolved Oxygen Levels0-4 mg/l poor4-7 mg/l fair7-10 mg/l good10-14 mg/l excellentover 14 ????? Check your test!

Page 15: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Interpreting Dissolved Oxygen Results

Page 16: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Dissolved Oxygen

Temperature

Page 17: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Measuring Conductivity

Page 18: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Conductivity Meter (and you get a thermometer)

Page 19: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

1500140013001200110010009008007006005004003002001000

ConductivityO

il and Gas W

ell Discharge

The higher the number, the poorer the quality.

Waste w

ater impact

Norm

al Stream

Rain

Page 20: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.
Page 21: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Conductivity

Flow

Page 22: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Field Observations

•Flow 0-5 point scale

•24 hour rainfallIn inches

•Turbidity 0-3 point scale

Some things are just best done in person.

Page 23: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Flow Observations

•Flow 0 = Dry1 = Ponded2 = low3 = Normal4 = Bank Full5 = FLOOD!

Get to know your creek

0=Dry

4=Bank Full

5=Flood!

Page 24: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Record Discharge in Cubic Feet Per Second

Page 25: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Estimate rainfall in your watershedin quarter inches for the last 24 hours

Use Weather Channel, local paper orToad Gauge

Page 26: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Value Observation NTUs

0 Crystal Clear 0 NTUs

1 Clear 1-3 NTUs

2 Cloudy 4-12 NTUs

3 Muddy >12 NTUs

Turbidity 0-3 point scale

Page 27: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Other observations to make

•Putrescent or otherwise objectionable bottom deposits

•Oil, scum, and floating debris in amounts that are unsightly

•Nuisance levels of odor, color, other conditions

Page 28: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

DO kitpH kitThermometerSpent chemical waste containerConductivity meter and screwdriver“Blue Book” of instructionsRecording formspencilFirst Aid Kit

Field Chemistry Check List

Page 29: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Equipment UseEquipment is “Loaned” to you for the duration of the project.Please return field kits to your area coordinator or sampling event coordinator if you “retire” from the project.

Page 30: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Kits have enough chemical for 50 tests! (use them all you want!)Store in a cool, dry place.

NOT a hot car or freezing garage!

Chemicals should be replaced every two years.Should you need replacement chemicalsor glassware before then, let us know.

Equipment Use

Page 31: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

There are hazardous chemicals in these kits!DO Test uses a strong alkali (like bleach)pH test chemical is flammable

Read Material Safety Data Sheets for handling and Disposal InstructionsUse plastic spent chemical waste container at streamDispose of properly at home.

Equipment Use

Page 32: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

We request that you Run D.O., Temp & pH test every field visit or sampling event.

Feel free to use them more frequently •For monthly or bi-weekly testing•For testing other resources•For educational demonstrations

Equipment Use

Page 33: Field Water Chemistry Analysis Equipment Care Test Procedures Results Interpretation Data Reporting.

Test at the creek!

ConductField Testsin actual conditions